• 제목/요약/키워드: Electrical Power Consumption

검색결과 1,398건 처리시간 0.03초

한국의 가정용 대기전력 소모현황 조사연구 (Survey on the Residential Standby Power Consumption in Korea)

  • 김남균;서길수;김상철;김은동
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권8호
    • /
    • pp.472-476
    • /
    • 2004
  • Standby power is the electricity consumed in an electrical equipment when it is switched-off or not performing its main function. Due to the acceleration of digital electronics and home networking, standby power use tends to increase rapidly year by year. In this paper, standby power consumption in residential sector in Korea has been surveyed and reported for the first time. Totally 825 pieces of electrical equipments that consume standby power in 53 households were investigated. The average standby power per equipment and total standby power per household were 3.66W and 57.0W, respectively. Annual standby power consumption per household was estimated 306kWh; which means the standby power consumption in residential sector in Korea can be estimated 4.6TWh a year representing 1.67 percent of total electrical consumption (274TWh).

OFDM 기반 광대역 멀티미디어 단말의 전력절감 효율 분석에 관한 연구 (Investigation of Power Saving Efficiency for the OFDM Based Multimedia Communication Terminal)

  • 문재필;이은서;김동환;이재식;장태규
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.155-158
    • /
    • 2005
  • An invesitigation on power consumption of a mobile multimedia system using OFDM and MDVS technique is reported here. Analysis and simulation are performed to find the significances of proposed Microscopic Dynamic Voltage Scaling(MDVS) tehnique[4] on digital processor in terms of power saving. A study is also made to show power reduction in mobile multimedia system by incorporating OFDM modulation scheme in RF front-end. Finally, overall power consumption by functionally distinguished blocks ie. RF front-end, digital processor and human interface unit is shown here. Total power consumption is 8.2W for 2Mbps SD-quality WCDMA multimedia video service - the power consumption of digital processor is 3.9W(48%), the power consumption of RF front-end is 3.2W (36%), and the power consumption of interface is 1.8W(16%). Power saving of applying purposed MDVS technique is 35% in digital processor, and power saving of OFDM technique is 10-12dB in RF front-end.

  • PDF

Flexible Prime-Field Genus 2 Hyperelliptic Curve Cryptography Processor with Low Power Consumption and Uniform Power Draw

  • Ahmadi, Hamid-Reza;Afzali-Kusha, Ali;Pedram, Massoud;Mosaffa, Mahdi
    • ETRI Journal
    • /
    • 제37권1호
    • /
    • pp.107-117
    • /
    • 2015
  • This paper presents an energy-efficient (low power) prime-field hyperelliptic curve cryptography (HECC) processor with uniform power draw. The HECC processor performs divisor scalar multiplication on the Jacobian of genus 2 hyperelliptic curves defined over prime fields for arbitrary field and curve parameters. It supports the most frequent case of divisor doubling and addition. The optimized implementation, which is synthesized in a $0.13{\mu}m$ standard CMOS technology, performs an 81-bit divisor multiplication in 503 ms consuming only $6.55{\mu}J$ of energy (average power consumption is $12.76{\mu}W$). In addition, we present a technique to make the power consumption of the HECC processor more uniform and lower the peaks of its power consumption.

전기철도차량의 주행 중 에너지 소비 특성 예측 및 분석 연구 (Prediction and Analysis of the Energy Consumption Considering the Electric Railway Vehicle's Driving)

  • 박찬배;이병송;이형우
    • 전기학회논문지
    • /
    • 제61권5호
    • /
    • pp.777-781
    • /
    • 2012
  • In this paper, an electrical power simulation program was developed to predict the energy consumption of the electrical railway propulsion system, which considered the actual operating conditions of the electric railway vehicles. The developed program was designed to predictable the energy consumption during a virtual driving in the actual route of the virtual railway vehicles equipped with a propulsion system consisting of power conversion equipments and traction motors. In addition, the accuracy verification of the electrical power simulation program for a propulsion system was performed by using a real power consumption data, which was measured during the driving of the railway vehicles in the Gyeongui Line. In conclusion, the electrical power simulation program for a propulsion system was validated throughout a comparative investigation between the simulated values and the experimental values and the energy consumption characteristics of electric railway vehicles on the existing route or the new route will be possible to predict throughout the virtual simulation considering the driving conditions of the electric railway vehicles.

교류 고속철도계통에서 BESS의 도입을 위한 전력소비 및 충·방전효과 분석에 관한 연구 (Study on Analysis for Power Consumption and Charge/Discharge Effect with BESS in AC High-Speed Electric Railway System)

  • 전용주;강병욱;채희석;김재철
    • 조명전기설비학회논문지
    • /
    • 제28권9호
    • /
    • pp.20-27
    • /
    • 2014
  • The power consumption pattern of high-speed railway has rarely during night time. But, during service time, the power is consumed irregularly related to train operation. Especially certain unusual about 1-2 days of service time interval to indicate the power consumption is rapidly growing phenomenon, which causes the capacity of the power contract is the annual electricity bill to rise rapidly as the cause. Normally, amount of peak power consumption bill rate at railway substation is over 20% of total electrical bill. Therefore, high-speed railway substation is expected to be considerably larger savings by reducing the peak power of the default charge(demand power).

부하 형태에 따른 전력패턴 분석 (Analysis of Power Pattern According to Load Types)

  • 황미용;조승준;이순형;최용성
    • 한국전기전자재료학회논문지
    • /
    • 제36권4호
    • /
    • pp.369-375
    • /
    • 2023
  • In this paper, we compared and analyzed the power load patterns of dormitory buildings and office buildings to use them as basic data (demand analysis and capacity design) for the design and operation of microgrids for multi-use facilities, and the following conclusions were got. During the daytime on regular weekdays, the power consumption load pattern of office buildings was relatively large at 264.0~332.3 kWh, and during the evening hours, the power consumption load pattern of dormitory buildings was relatively large at 233.0~258.3 kWh. In the case of vacation, during the daytime on weekdays, the power consumption load pattern of office buildings was relatively large at 279.1~407.4 kWh, and in the evening, the power consumption load pattern of dormitory buildings was relatively high at 280.1~394.1 kWh. During the daytime on regular weekends, the power consumption of dormitory-type buildings was relatively high at 133.5~201.6 kWh, and it was found that the power consumption of dormitory-type buildings appeared relatively high at 187.5~252.1 kWh. During a vacation in the daytime on weekends, the power consumption of dormitory-type buildings was found to be 186.5 kWh~ and 218.6 kWh. The increase in power consumption during a vacation (December-February) compared to normal (April-June) was thought to be due to an increase in electricity demand, and the reason for the higher power consumption in dormitory buildings during the vacation was due to reduced working hours in office buildings.

Effect of Pulp Properties on the Power Consumption in Low Consistency Refining

  • LIU, Huan;DONG, Jixian;QI, Kai;GUO, Xiya;YAN, Ying;QIAO, Lijie;DUAN, Chuanwu;ZHAO, Zhiming
    • Journal of the Korean Wood Science and Technology
    • /
    • 제48권6호
    • /
    • pp.869-877
    • /
    • 2020
  • The power consumption in the low consistency (LC) refining is an important indicator for the optimal control of the process and it is composed of the net power and the no-load power. The refining efficiency and process characterization of LC refining are directly affected by power consumption. In this paper, the effect of pulp consistency and average fiber length on the power consumption and refining efficiency were studied through the LC refining trials conducted by an experimental disc refiner. It is found that the curve of power-gap clearance can be divided into constant power section, power reduction section, and power increase section. And the no-load power and the adjustable domain of loading applied by the refining plates will increase as the increase of pulp consistency, while the increase of net power is larger than that of no-load power which makes the increasing of refining efficiency. Meanwhile, the adjustable domain of loading applied by the refining plates can be slightly improved by increasing the average fiber length, but its effect on the no-load power in the LC refining process can be neglected. The study of power consumption in LC refining is of positive significance for the proper selection of pulp properties in LC refining, in-depth exploration of refining mechanism, and energy consumption reduction in refining.

AV 기기를 위한 AC 입력 전류 모니터링 대기 전력 저감 시스템 (Reducing Standby Power Consumption System by Monitoring the AC Input Current for the AV Devices)

  • 이대식;이강현
    • 전기학회논문지
    • /
    • 제65권9호
    • /
    • pp.1493-1496
    • /
    • 2016
  • This paper proposes a system for reducing the standby power consumption in using the consumer electronic devices such as a television, a home theater, a set-top box, or a DVD player. The system is consisted of a flyback converter, monitoring circuits, a relay and a micro-processor. The proposed system can reduce the standby power consumption by disconnecting the AC input and the consumer devices can be turned on with a remote control. The proposed standby power system consumes the low power to receive the infrared signal from the remote controller. Furthermore, a electronic double layer capacitor is used to store the energy with high efficiency. The proposed power system can operate the 플라이백 converter to charge the electronic double layer capacitor and connect the AC input to the consumer electronic devices. The proposed power circuit can reduce the standby power consumption in AV devices without increasing the cost. The prototype is implemented to verify the system with the commercialized products.

Circuit Techniques for Low-Power Data Drivers of TFT-LCDs

  • Choi, Byong-Deok;Kwon, Oh-Kyong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제1권3호
    • /
    • pp.167-181
    • /
    • 2001
  • A stepwise driving method was used for reducing the AC power consumption in a TFT-LCD. The AC power takes the largest portion of the total power consumption of a TFT-LCD. Experimental results confirmed that the AC power saving efficiency reached up to 75% when a 5-stepwise driving with each step time of $2\mu$ sec was applied to a 14.1 inch-diagonal XGA TFT-LCD. The second largest component of power consumption called the DC power comes from the quiescent currents in Op-amps. A simple and efficient architecture was proposed in this work to reduce this DC power consumption: Half of the Op-amps have the 5V-supplies, and the rest half have the 10V-supplies, and two Op-amps are shared by adjacent two channels. Measurements of test circuits showed that this simple method could reduce over 40% of the DC power consumption..

  • PDF

Group Building Based Power Consumption Scheduling for the Electricity Cost Minimization with Peak Load Reduction

  • Oh, Eunsung;Park, Jong-Bae;Son, Sung-Yong
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.1843-1850
    • /
    • 2014
  • In this paper, we investigate a group building based power consumption scheduling to minimize the electricity cost. We consider the demand shift to reduce the peak load and suggest the compensation function reflecting the relationship between the change of the building demand and the occupants' comfort. Using that, the electricity cost minimization problem satisfied the convexity is formulated, and the optimal power consumption scheduling algorithm is proposed based on the iterative method. Extensive simulations show that the proposed algorithm achieves the group management gain compared to the individual building operation by increasing the degree of freedom for the operation.