• Title/Summary/Keyword: Electrical Pole

Search Result 1,094, Processing Time 0.031 seconds

Effect of Stationary Pole Pieces with Bridges on Electromagnetic and Mechanical Performance of a Coaxial Magnetic Gear

  • Jang, Dae-Kyu;Chang, Jung-Hwan
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.207-211
    • /
    • 2013
  • In a coaxial magnetic gear, bridges connecting separate pole pieces are useful for fabrication and also improve mechanical reliability. However, they have a negative influence on electromagnetic performance parameters such as transmission torque and iron loss. This paper investigates the effect of stationary pole pieces connected by bridges on the electromechanical characteristics. The bridge type and thickness are the main parameters influencing the performance of a coaxial magnetic gear. The inner, center, and outer bridge types each show the best performance in terms of different characteristics. However, for any bridge type, an increase in the bridge thickness reduces the overall electromagnetic performance, except for the torque ripple, and improves the overall mechanical performance, including the deformation, von Mises stress, and natural frequency of the stationary part.

Interior Central Pole Search Coils for Initial Rotor Position Detection of a Toroidal SRM (토로이달 SRM의 초기 회전자 위치검출을 위한 돌극 관통 서치코일)

  • 양형열;임영철
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.7
    • /
    • pp.473-482
    • /
    • 2004
  • In this paper, a detection technique of initial rotor position at a standstill in Toroidal Switched Reluctance Motor(TSRM) with built-in interior central pole search coil is proposed. In case search coils are used as a position sensor, it has many advantages like low cost, decrease in the volume, high robust characteristics and wide applications. However, the initial rotor position detection is very difficult because the search coil's EMF is not exist at a standstill. In this paper, a new detection method of initial rotor position is suggested using interior central pole search coil. The simulation and experiment for the proposed method and their results support the validity of the proposed scheme by verifying the operation of a 6/4 TSRM using search coils.

A Study on the Age Degradation Kinetics of Pole Transformer Oil (주상변압기 절연유의 경년열화반응 속도론에 관한 연구)

  • 남영우
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.1
    • /
    • pp.99-105
    • /
    • 1997
  • In the paper, aging of insulating oil in pole transformer has been studied by performing accelerated thermal aging test. Dissolved gases were extracted by air bubbling method. Concentration of dissolved gases were modified by extraction ratio of each gases in insulating oil. Aging of insulating materials were proceeded by thermal degradation and oxidation reaction. Both of the reactions followed zeroch order kinetics. Formation rate equations for hydrocarbons, carbon oxides, and hydrogen were derived. It was conformed by gas analysis and UV-Visible spectrophotometric method that iron core and copper coil in pole transformer act as catalyst during the aging process.

  • PDF

Pole-Placement Self-Tuning Control for Robot Manipulators in Task Coordinates (작업좌표에서 로보트 매니퓰레어터에 대한 극점배치 자기동조 제어)

  • 양태규;이상효
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.3
    • /
    • pp.247-255
    • /
    • 1989
  • This paper proposes an error model with integral action and a pole-place-ment self-tuning controller for robot manipulators in task coordinates. The controller can reject the offset due to any load disturbance without a detailed description of the robot dynamics. The error model parameters are estimated by the recursive least square identification algorithms, and controller parameters are determined by the pole-placement method. A computer simulation study has been conducted to demonstrate the performance of the proposed control system in task coordinates for a 3-joint and 2-link spatial robot manipulator with payload.

Zero-voltage-switching three level auxiliary resonant commutated pole inverter (영전압 스위칭 3-레벨 보조 공진 폴 인버터)

  • 유동욱;원충연;조정구;백주원
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.4
    • /
    • pp.535-542
    • /
    • 1996
  • A zero voltage switching (ZVS) three level auxiliary resonant commutated pole inverter (ARCPI) is presented for high power GTO inverters. The concept of ARCP for two level inverter is extended to the three inverter. The proposed auxiliary commutation circuit consists of one resonant inductor and two bi-directional switches, which provides ZVS condition to the main devices without increasing device voltage or current stresses. The auxiliary device operates with zero current switching (ZCS) which enables use of the low cost thyristors. The proposed ARCPI can handle higher voltage and higher power (1-10MVA) comparing to the two level one. Operation and analysis of the ARCPI are illustrated and the features are compared o those of the snubber circuit incorporated three level inverter. Experimental results with 10kW, 4kHz prototype are presented to verify the principle of operation. (author). refs., figs., tab.

  • PDF

Design and Fabrication of Multilayer Chip Filter for Next Generation Mobile Communication Phone (차세대 이동통신 단말기에 이용되는 적층 칩 필터 설계 및 제작)

  • 이석원;윤중락
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.7
    • /
    • pp.583-591
    • /
    • 2000
  • It this paper the multilayer chip band pass filter for next generation mobile communication phone is fabricated and designed. For the design the multilayer chip filter of non-contented equivalent circuit and contented equivalent circuit with attenuation pole is presented. Finally it is fabricated and designed using the multilayer chip filter of contented equivalent circuit with attenuation pole. The size insertion loss center frequency and band width of multilayer chip filter are 4.5$\times$3.2$\times$2.0[mm], 3.0[d.B] and 1945$\pm$25 MHz respectively. The multilayer chip filter was fabricated by screen printing with Ag electrode after tape casting. Simulation results of multilayer chip filter are compared with experimental results and found to be in excellent agreements.

  • PDF

The Method for Replacement of Strain Pole Crossarm using the Hot-line Support Arm (핫라인 써포트암을 이용한 완철교체공법)

  • Mun, S.W.;Park, Y.B.;Kim, J.S.;Song, H.S.;Cho, S.H.;Choi, M.H.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.59-64
    • /
    • 2006
  • In this paper, developed a uninterruptible hotline tools and method for replacement of strain pole crossarm on overhead distribution line. For practical use of developed tools, following direct hot-line methods were proposed: 'Direct hot-line method for replacement of pin pole crossarm', 'Direct hot-line method for alteration of crossarm' and 'Crossarm replacement method in uninterruptible cable displacement area'. These methods were proposed more simple and safe working on hotline job.

  • PDF

On-site Survey of the Street Lighting Facilities (가로등의 전기설비 현장실태조사)

  • Kim, Han-Sang;Bae, Suk-Myong;Kim, Chong-Min
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.426-431
    • /
    • 2006
  • The case where a drain cannot flow backwards, a sewer institution can be unmanageable in this, and a mad is under water momentarily by local heavy nin by the climate phenomenon in spite of not being a lowlands belt has occurred well more than recently. By the flooded mea since it is in the state which has some human bodies at hand, when a short circuit occurs in street lighting pole which is the electric institution thing of a road, the danger of an electric shock accident becomes higher. In this paper, it was going to show improvement plan for grasping the brittle factor of street lighting pole electricity facilities through the on-site survey of street lighting pole electricity facilities, and improving this.

  • PDF

Experimental Study of The Floating-Phenomenon on Neutral Ungrounded UPS System (중성점 비접지 UPS시스템의 부동현상에대한 실험적 연구)

  • Shim, Hae-Sup
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.5
    • /
    • pp.67-72
    • /
    • 2011
  • In this study we investigate the background of UPS output transformer(${\Delta}-Y$) operation on neutral ungrounded system, and perform field experiment of neutral floating-phenomenon for the inter-locked securing of electric facilities and improvement of neutral floating-phenomenon. Experiment results show that a floating-phenomenon occurs when four-pole input-breaker trip and the neutral to earth voltage occurring concurrently is identified as phantom voltage. And the measures for the transient overvoltage that can occur in floating-state also are investigated. As a result, the risk elements of neutral ungrounded method as well as neutral floating-phenomenon are removed by installation of separate solidly-grounded transformer and switching four-pole input-breaker to three-pole input breaker.

Development Pole Transformer with Automatic Tap Changer (자동 탭 절환 내장형 주상변압기 개발에 관한 연구)

  • Nam-Koong, Won;Lee, Sung-Woo;Jang, Moon-Jong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.9
    • /
    • pp.108-113
    • /
    • 2013
  • Change of supply voltage, customer load, output of distributed generation, etc cause voltage change in distribution system. OLTC and SVR are usually used to supply normal voltage at customer. But usage of these devices is inefficient and uneconomical in certain circumstances. To solve this problem, new pole transformer which has automatic tap changer is developed. The transformer changes tap when voltage changes. And it has latch switch and reactor for supplying power without outage. To verify normal operation of tap changer, test is conducted. SVR and 50kVA load is used for test.