• Title/Summary/Keyword: Electrical Pole

Search Result 1,094, Processing Time 0.029 seconds

3-D Inversion of 3-D Synthetic DC Resistivity Data for Vein-type Ore Deposits (국내 맥상광체조사를 위한 3차원 전기비저항 모델링자료의 3차원 역산 해석)

  • Lee, Ho-Yong;Jung, Hyun-Key;Jeong, Woo-Don;Kwak, Na-Eun;Lee, Hyo-Sun;Min, Dong-Joo
    • Journal of the Korean earth science society
    • /
    • v.30 no.6
    • /
    • pp.699-708
    • /
    • 2009
  • Recently as the interest in the development of domestic ore deposits has increased, we can easily find some studies on exploration geophysics-based ore-deposit survey in literature. Based on the fact that mineralized zone are generally more conductive than surrounding media, electrical resistivity survey among several geophysical surveys has been applied to investigate metallic ore deposits. Most of them are grounded on 2-D survey. However, 2-D inversion may lead to some misinterpretation for 3-D geological structures. In this study, we investigate the feasibility of the 3-D electrical resistivity survey to 3-D vein-type ore deposits. We first simulate 2-D dipole-dipole survey data for survey lines normal to the strike and 3-D pole-pole survey data, and then perform 3-D inversion. For 3-D ore-body structures, we assume a width-varying dyke, a wedge-shaped, and a fault model. The 3-D inversion results are compared to 2-D inversion results. By comparing 3-D inversion results for 2-D dipole-dipole survey data to 3-D inversion results for 3-D pole-pole survey data, we could note that the 2-D dipole-dipole survey data yield better inversion results than the 3-D pole-pole data, which is due to the main characteristic of the pole-pole array. From these results, we are convinced that if we have certain information on the direction of the strike, it would be desirable to apply 2-D dipole-diple survey for the survey lines normal to the strike. However, in most cases, we do not have any information on the direction of the strike, because we already developed the ore deposit with the outcrops and the remaining ore deposits are buried under the surface. In that case, performing 3-D pole-pole electrical resistivity survey would be a reasonable choice to obtain more accurate interpretation on ore body structure in spite of low resolution of pole-pole array.

Research of $Tan{\delta}$ Measurement on pole Transformer Using DSP (DSP를 이용한 주상변압기 $Tan{\delta}$ 측정기법 연구)

  • Lee, Bo-Hoo;Kim, Jae-Chul;Lee, Su-Kil;Yoon, Yong-Han;Kim, Oun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.270-272
    • /
    • 1996
  • This paper describes the dissipation factor measuring techniques of insulating oil on operating pole transformer by using digital signal processor. After applying voltage to the electrodes which is installed in a transformer, acquiring source voltage and current of electrodes and using cross-correlation techniques, we can check the dissipation factor of insulating oil. To improve measuring accuracy and the speed of process, we use hardware such as TMS320C31 DSP board and software such as cross-correlation techniques and rectangular window techniques. We simulated the measuring accuracy and the degree of the noise effect of this new measuring techniques by using computer simulation, and compared the simplified measuring devices with schering bridge on degraded insulating oil. The result showed that this measuring technique can be used as diagnostic method on the pole transformers.

  • PDF

The Design Conditions of Single Phase SRM Pole-Arcs for Blower Drives (송풍기 구동용 단상 SRM의 극호 설계 조건)

  • Lee, Jong-Han;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2003.10b
    • /
    • pp.125-127
    • /
    • 2003
  • The single phase switched reluctance motor(SRM) is more simpler and robust in the structure than poly phase SRM. It has the merits that it reduces the switching elements and the energy density per volume is very high. Recently, it has been researched and developed in various types and starting method due to the technique of power electronics and the computer added design. The single phase SRM is tried to apply to many industrial appliance field to substitutethe the induction motor by the single phase SRM. On the previous studies, we decided the design parameters of the single phase SRM for the blower driver to adapt the design method of the conventional machine and the poly phase SRM. In this studies, it is proposed the conditions to decide the optimal pole arcs because the stator and rotor pole arcs is very important in the characteristics of the single phase SRM. For this reason, it is analysed the characteristics of current on/off angle vs. pole arc, pole arcs vs. average torque.

  • PDF

Investigation on Characteristics of Interior Permanent Magnet Synchronous Motor according to Pole-Slot Combination (매입형 영구자석 동기전동기의 극 수 슬롯 수 조합에 따른 특성에 관한 연구)

  • Bahn, Ji-Hyung;Kwon, Soon-O;Ha, Seung-Hyonng;Hong, Jung-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.771-772
    • /
    • 2006
  • Recently, Interior Permanent Magnet Synchronous Motor(IPMSM) is widely used in the industry applications such as power train for hybrid vehicles and compressor motors of air-conditioner due to its high power density and wide speed range. In designing motors, pole slot combination should be chosen properly according to the use of the motor and driving method in the initial design stage, accordingly there have been many researches about pole slot combination. As a part of the studies, this paper presents a comparison of characteristics of concentrated winding IPMSM, such as back-emf, Total Harmonic Distortion(THD) and core losses for each pole slot combination. By comparing the characteristics of each model, this paper can be a guide or reference in determining pole slot combination in the initial design stage.

  • PDF

Short-Term Load Forecasting of Pole-Transformer Using Artificial Neural Networks (신경회로망을 이용한 배전용 변압기의 단기부하예측)

  • Kim, Byoung-Su;Shin, Ho-Sung;Song, Kyung-Bin;Park, Jung-Do
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.810-812
    • /
    • 2005
  • In this paper, the short-term load forecasting of pole-transformer is performed by artificial neural networks. Input parameters of the Nosed algorithm are peak loads of pole-transformer of previous days and their temperatures. The proposed algorithm is tested for ore of the pole-transformers in seoul, korea. Test results show that the proposed algorithm improves the accuracy of the load forecasting of pole-transformer compared with the conventional algorithm.

  • PDF

Neutral Current Calculation of Electric Pole in Distribution Line (배전선로 장주의 중성선 전류 계산)

  • Seo, H.C.;Kim, C.H.;Jung, C.S.;Yoo, Y.P.;Lee, C.W.
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.87-89
    • /
    • 2005
  • If the three phases are not balanced, the current in neutral line is not zero. Then, the induced voltage can be generated In communication line. The KEPCO's rule about unbalanced current in single electric pole is a twenty percent of phase current. But the unbalanced current in double electric pole can't decide the rule because there are many different views. This paper develops the calculation and analysis technique of neutral current in single electric pole and double electric pole using equivalent circuit analysis, vector analysis and EMTP simulation.

  • PDF

Mismatching Problem between Generic Pole-assignabilities by Static Output Feedback and Dynamic Output Feedback in Linear Systems

  • Kim Su-Wood
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.1
    • /
    • pp.56-69
    • /
    • 2005
  • In this paper, it is clearly shown that the two well-known necessary and sufficient conditions mp n as generic static output feedback pole-assignment and mp + d(m+p) n+d as generic minimum d-th order dynamic output feedback pole-assignment on complex field, unbelievably, do not match up each other in strictly proper linear systems. For the analysis, a diagram analysis is newly created (which is defined by the analysis of 'convoluted rectangular/dot diagrams' constructed via node-branch conversion of the signal flow graphs of output feedback gain loops). Under this diagram analysis, it is proved that the minimum d-th order dynamic output feedback compensator for pole-assignment in m-input, p-output, n-th order systems is quantitatively decomposed into static output feedback compensator and its associated d number of arbitrary 1st order dynamic elements in augmented (m+d)-input, (p+d)-output, (n+d)-th order systems. Total configuration of the mismatched data is presented in a Table.

Breakdown Properties for Insulation Design of the Environment-Friendly Pole Transformer using the Vegetable Insulating Oil (식물성절연유를 사용한 친환경 주상변압기 설계를 위한 절연파괴 특성)

  • Kwag, Dong-Soon
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.6
    • /
    • pp.7-12
    • /
    • 2011
  • In recent years, environmental concerns have been raised on the use of poorly biodegradable fluids in electrical apparatus in regions where spills from leaks and equipment failure could contaminate the surroundings. The newly invented vegetable insulating oil is highly biodegradable and have negligible impact on the environment, human health and the ecosystem. For development of the environmental-friendly pole transformer using vegetable insulating oil, the dielectric constructions of the pole transformer were discussed in this paper. Depending on the dielectric constructions, the AC breakdown characteristics of the Nomex insulating papers and the vegetable insulating oil were studied by simulated electrode systems. Based on the experimental results, the maximum design stress($E_{max}$) for insulation design of the environmental-friendly pole transformer were suggested.

Characteristic Analysis of Single Phase SRM on Pole Ratio (극호비에 따른 단상 SRM의 토오크 특성 해석)

  • Lee, Jong-Han;Lee, Eun-Woong;Lee, Chung-Won
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.690-692
    • /
    • 2003
  • The single phase switched reluctance motor has been studied and developed actively in the various applications with several kinds and forms because of the developments of the design technique by using the computer and of the driving technique power electronic technology, which has the merits of a simple and robust structure, and first of all reducing the number of the switching devices in comparison with poly phase switched reluctance motor. And also, the studies are making progess to substitute the switched reluctance motor for single phase induction motor. In the previous studies, the single phase switched reluctance motor for the drive of blower is designed with the design theory of the conventional rotating electric machine and poly phase switched reluctance motor. In this paper, we intend to select the optimal pole arc and pole pitch ratio by the FEM analysis, because the pole arc and pole pitch are very important factor to determine the characteristics of switched reluctance motor.

  • PDF

Characteristic Analysis and Comparison of IPMSM for HEV According to Pole and Slot Combinations (극 수와 슬롯 수 조합에 따른 HEV용 IPMSM의 특성 비교 및 분석)

  • Jung, Jae-Woo;Kwon, Soon-O;Hong, Jung-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1017-1018
    • /
    • 2007
  • Interior permanent magnet synchronous motor (IPMSM) for traction motor in the hybrid electric vehicle (HEV) has different parameters and characteristics according to pole and slot combinations. The fitting combination of pole and slot in the IPMSM improves characteristics of traction system ultimately. This paper deals with analyzing the characteristics of IPMSM for mild type HEV according to pole and slot combinations. Based on the result of characteristics, suitable pole and slot combination is presented to maximize efficiency of traction motor in the HEV system.

  • PDF