• Title/Summary/Keyword: Electrical Load

Search Result 6,131, Processing Time 0.03 seconds

Parallel Distributed Implementation of GHT on Ethernet Multicluster (이더넷 다중 클러스터에서 GHT의 병렬 분산 구현)

  • Kim, Yeong-Soo;Kim, Myung-Ho;Choi, Heung-Moon
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.46 no.3
    • /
    • pp.96-106
    • /
    • 2009
  • Extending the scale of the distributed processing in a single Ethernet cluster is physically restricted by maximum ports per switch. This paper presents an implementation of MPI-based multicluster consisting of multiple Ethernet switches for extending the scale of distributed processing, and a asymptotical analysis for communication overhead through execution-time analysis model. To determine an optimum task partitioning, we analyzed the processing time for various partitioning schemes, and AAP(accumulator array partitioning) scheme was finally chosen to minimize the overall communication overhead. The scope of data partitioned in AAP was modified to fit for incremented nodes, and suitable load balancing algorithm was implemented. We tried to alleviate the communication overhead through exploiting the pipelined broadcast and flat-tree based result gathering, and overlapping of the communication and the computation time. We used the linear pipeline broadcast to reduce the communication overhead in intercluster which is interconnected by a single link. Experimental results shows nearly linear speedup by the proposed parallel distributed GHT implemented on MPI-based Ethernet multicluster with four 100Mbps Ethernet switches and up to 128 nodes of Pentium PC.

An Empirical Study on the Thermal Performance and Dynamic Behavior of Wall Integrated Thermosiphon Solar Water Heater (벽체일체형 자연순환 태양열온수기의 동적거동과 열성능에 관한 실증연구)

  • Baek, Nam-Choon;Kim, Sung-Bum;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.6
    • /
    • pp.25-35
    • /
    • 2016
  • In this study, the evaluation of the dynamic behavior and thermal performance of the "Façade integrated Natural circulation Solar Water Heating System" installed in the residential house was carried out. Experimental tests were performed during the all year around in the rural houses of $166m^2$ in size. Facade integrated solar collector of $5m^2$ were installed on the south-facing. Electrical heater of 1 kW capacity as an auxiliary heater was installed at the upper part of the heat storage tank. The analyzing results are as follows. (1) Monthly average solar fraction was 51 to 87% and yearly average value is 64%. (2) Hot water supply temperature in December which has the lowest solar altitude is 37 to $76^{\circ}C$. The highest working fluid temperature of solar collector in this period was below $84^{\circ}C$. The temperature difference of working fluid between the collector inlet and outlet has been shown to be around 9 to $26^{\circ}C$. (3) Overheating which is one of the biggest problems during summer did not appear at all, but rather had hot water supply temperature is rather low as $30{\sim}47^{\circ}C$ in summer than winter, which is supplied by a small solar load. The solar collecting temperature has been shown to maintain below $55^{\circ}C$. (5) The thermal performance of Facade integrated solar collector can be increase due to the reduction of heat loss to the back of the collector wall integration of the collector is reduced. As a conclusion, Facade integrated natural circulation type Solar Water Heating System is a well-functioning without any pumps or controllers, and it was found that the disadvantages of conventional solar water heaters, hot water or hot water system can be greatly improved.

Reliability Estimation of High Voltage Ceramic Capacitor by Failure Analysis (고압 커패시터의 고장 분석을 통한 신뢰도 예측)

  • Yang, Seok-Jun;Kim, Jin-Woo;Shin, Seung-Woo;Lee, Hee-Jin;Shin, Seung-Hun;Ryu, Dong-Su;Chang, Seog-Weon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.6
    • /
    • pp.618-629
    • /
    • 2001
  • This paper presents a result of failure analysis and reliability evaluation for high voltage ceramic capacitors. The failure modes and failure mechanisms were studied in two ways in order to estimate component life and failure rate. The causes of failure mechanisms for zero resistance phenomena under withstanding voltage test in high voltage ceramic capacitors molded by epoxy resin were studied by establishing an effective root cause failure analysis. Particular emphasis was placed on breakdown phenomena at the ceramic-epoxy interface. The validity of the results in this study was confirmed by the results of accelerated testing. Thermal cycling test for high voltage ceramic capacitor mounted on a magnetron were implemented. Delamination between ceramic and epoxy, which might cause electrical short in underlying circuitry, can occur during curing or thermal cycle. The results can be conveniently used to quickly identify defective lots, determine $B_{10}$ life estimation each lot at the level of inspection, and detect major changes in the vendors processes. Also, the condition for dielectric breakdown was investigated for the estimation of failure rate with load-strength interference model.

  • PDF

PREDICTION OF PHYSICO-CHEMICAL AND TEXTURE CHARACTERISTICS OF BEEF BY NEAR INFRARED TRANSMITTANCE SPECTROSCOPY

  • Olivan, Mamen;Delaroza, Begona;Mocha, Mercedes;Martinez, Maria Jesus
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1256-1256
    • /
    • 2001
  • The physico-chemical and texture characteristics of meat determine the nutritional, technological and sensory quality. However, the analysis of meat quality requires expensive, laborious and time consuming analytical methods. The objective of this study was to evaluate NIR spectroscopy using transmittance for determining the moisture, fat, protein and total pigment content, the water holding capacity (WHC) and the toughness of beef meat. A total of 318 spectra were recorded from ground beef samples by a Feed Analyzer 1265 of Infratec. The samples were obtained from the Longissimus muscle of the 10$^{th}$ rib of yearling bulls, ground with an electrical chopper, vacuum packaged, aged during 7 days and frozen at -24$^{\circ}C$ until the analyses were done. Moisture content was measured by oven drying at 10$0^{\circ}C$, fat content was determined by Soxhlet extraction and protein content was estimated from nitrogen content using the Kjeldahl analysis. The total pigment content was determined by the method of Hornsey and the WHC using the method of filter paper press. The instrumental evaluation of texture (maximum load WB, maximum stress MS and toughness) was conducted in an Instron equipment with a Warner-Bratzler shearing device. This analysis was performed on a chop of 3.5 cm obtained from the longissimus of the 8$^{th}$ rib, aged during 7 days, kept frozen at -24$^{\circ}C$ and cooked before the analysis. Near infrared spectra were recorded as log 1/T (T=transmittance) at 2 nm intervals from 850 to 1050 nm using a Feed Analyzer 1265 of Infratec. Calibrations were performed with the WinISI software (vs. 1.02) using the MPLS method. To examine the effect of scatter correction o. derivation of spectra on the calibration performance, calibrations were calculated with the crude spectra or pretreated with different mathematical treatments (inverse MSC, SNVD) and/or second derivative operation. For chemical composition, the use of the scatter corrections improved the calibration statistics, in terms of lower SECV and higher $r^2$. In most of the variables, the use of the 2$^{nd}$ derivative improved the predictions, mainly when combined with the SNVD treatment. However, for predicting the texture traits, the best estimation was obtained from the crude spectrum. These results showed that the equations obtained for predicting moisture, fat and total pigments were very accurate, with $r^2$ being higher that 0.9. However, the prediction of the texture traits (WB, MS, toughness) from ground meat was poor.

  • PDF

Design and Manufacture of Improved Obstacle-Overcoming type Indoor Moving and Lifting Electric Wheelchair (향상된 장애물 극복형 실내 이·승강 전동휠체어의 설계 및 제작)

  • Kim, Young-Pil;Ham, Hun-Ju;Hong, Sung-Hee;Ko, Seok-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.851-860
    • /
    • 2020
  • With an increase in the aging population and a rising social interest in health and welfare, studies to improve healthcare in the elderly are being actively conducted. This study attempted to improve the current design and manufacture of elevating electric wheelchairs to enhance user safety and convenience. Seat design based on the user's body shape, convenience while boarding or alighting, caster turning radius and, safety and stability features that prevent shaking when the user gets up or sits down were improved. A driving experiment was conducted to evaluate the operation of the indoor electric wheelchair designed and manufactured with these additional functionalities. During the test, the performance parameters evaluated were continuous driving time, turning radius, maximum lifting and lowering load, maximum lifting height, noise level, minimum distance sensing by the driving auxiliary sensor, ability to interact with server and app programs, and the duty cycle maximum error rate. The test confirmed that this improved electric wheelchair successfully met target parameters. In a future study, we will evaluate this improved electric wheelchair from a user's perspective for its usability parameters, such as satisfaction, convenience and stability.

DEVELOPMENT OF AC SERVO MOTOR CONTROLLER FOR INDUSTRIAL ROBOT AND CNC MACHINE SYSTEM (산업용 ROBOT와 공작기계를 위한 AC SERVO MOTOR 제어기 개발)

  • Lim, Sang-Gwon;Lee, Jin-Won;Moon, Yong-Ky;Jeon, Dong-Lyeol;Jin, Sang-Hyun;Oh, In-Hwan;Kim, Dong-Il;Kim, Sung-Kwun
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1211-1214
    • /
    • 1992
  • AC servo motor drives, Fara DS series, proposed in this paper can be effectively used in robots, CNC machine tools, and FA system with AC servo motors as actuators. The inverter of the AC servo drive consists of IGBT (Insulated Gate Bipolar Transistor) which have high switching frequency. Noises and vibrations generated in variable speed control of AC servo motors can be greatly reduced due to their high switching frequencies. In the developed servo drive, maximum torque is always generated in the whole speed range by compensating phase shift, which results from the nonlinearies of the AC servo motor during abrupt acceleration and deceleration. Abundant protection functions are provided to prevent abnormal state of the servo motor, and furthermore diverse user options are considered provided for the effective application. The proposed AC servo motor drive is designed to minimize velocity variation with respect to external load, supply voltage, environmental temperature, and humidity, so can be widely used in the fields of factory automation including robots and CNC msachine tools.

  • PDF

Algorithm Calculating Optimal DG Capacity Considering Operating Deficit in Hybrid Internal Combustion Generation (하이브리드 내연발전에서 도서 운영 결손액을 고려한 분산전원 최적 용량 산정 알고리즘)

  • Son, Joon-Ho;Kim, Mi-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.655-660
    • /
    • 2018
  • Internal combustion generation (ICG) is used to supply power to islands due to geographical characteristics, but there are some problems, such as considerable operating cost, salt pollution, and environmental pollution. For these islands, KEPCO pays a significant amount of operating deficit each year, especially for the fuel and servicing costs, which account for a large portion of this deficit. Integrated ICG (IICG) through an offshore cable between near islands is being considered to decrease servicing costs. Distributed generation (DG) is also being introduced on the islands because of the demand for a low-carbon society. In hybrid internal combustion generation (HICG), DG is introduced into IICG, which can be applied because the DG output is insufficient due to environmental characteristics, and the IICG is used as an auxiliary power source. Therefore, this paper proposes an algorithm to estimate the optimal DG capacity that can be introduced in accordance with the KEPCO operating deficit in the HICG. According to simulations, the optimal DG capacity depends on the fuel cost and load capacity. The validity of the proposed algorithm was confirmed for multiple islands with different peak loads.

Reliability Analysis of EMU Static Inverters considering Influence of Temperature Stress Factor (온도스트레스 영향을 고려한 전동차 보조전원장치의 신뢰성분석)

  • Park, Nam-Chul;Song, Joong-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.493-500
    • /
    • 2017
  • Based on the data accumulated through EMU fault management, this paper examines the reliability of old railway car parts and proposes measurements to improve safety. Subway Line 7 of the Seoul Metropolitan Rapid Transit Corporation, auxiliary power unit (Static Inverter) of the EMU second version is a core equipment to supply power to various room-service units in cars and make an effect directly on passenger satisfaction. To analyze the pattern of failure throughout the field data over a long period of time, this analysis of statistics and reliability considers the operating environment and stress factors. This statistical analysis presents the correlation between failure and the temperature stress factors related to frequent failure occurring intensively in summer. In addition, throughout the analysis of the life of the IGBT inverter, the effect of the temperature stress factor was observed before and after the repair. As a result of an analysis of the optimal operating conditions considering two variations of EMU, such as variable load and outside temperature, a difference in the cooling capacity between the optimal operating conditions and frequent failure conditions was observed. Based on this analysis, this paper suggests a way to minimize cooling capacity difference for the optimal operational conditions.

불국사 석탑의 지반 특성에 대한 지구물리탐사

  • Seo, Man-Cheol;O, Jin-Yong;Choe, Hui-Su
    • Journal of the Korean Geophysical Society
    • /
    • v.5 no.2
    • /
    • pp.143-151
    • /
    • 2002
  • Bulku temple in the city of Kyungju, Korea, built in 791 and reconstructed in the 20th century, is the home of seven national treasures including two three-story stone pagodas, Dabotap (height 10.4m, width 7.4m, weight 123.2ton) and Seokgatap (height 10.8m, width 4.4m, weight 82.3 ton). An earlier archaeological investigation shows that stone pagodas have experienced severe weathering process which will threaten their stability. At the base part of Dabotap, an offset of the stone alignment is also observed. For the purpose of the structural safety diagnosis of two pagodas, we introduce the nondestructive geophysical methods. Site characteristics around the pagodas are determined by the measurement of multiple properties such as seismic velocity, resistivity, image of GPR(ground-penetrating radar). Near the pagodas, the occurrence of high resistivity (up to 2200 Ωm) is obvious whereas their outskirts have as low as 200 Ωm. For the velocity of the P wave, the site of Dabotap has the range of 500~800 m/s which is higher than counterpart of Seokgatap with the velocity of 300~500m/s, indicating the solider stability of Dabotap site. Consequently, in addition to GPR images, the foundation boundaries beneath each stone pagodas are revealed. The Dabotap site is in the form of an octagon having 6-m-long side with the depth of ~4m, whereas the Seokgatap site the 9m × 10m rectangle with the depth of 3m. These subsurface structures appear to reflect the original foundations constructed against the stone load of ~8 ton/㎡. At the subsurface beneath the northeast of each pagoda, low seismic velocity as well as low resistivity is prominent. It is interpreted to represent the weak underground condition.

  • PDF

Evaluation of Weighted Correlator for Multipath Mitigation in GPS Receiver (GPS수신기의 다중경로 오차 제거를 위한 가중 상관기의 성능평가)

  • Shin, Mi-Young;Jang, Han-Jin;Suh, Sang-Hyun;Park, Chan-Sik;Hwang, Dong-Hwan;Lee, Sang-Jeong
    • Journal of Navigation and Port Research
    • /
    • v.31 no.5 s.121
    • /
    • pp.409-414
    • /
    • 2007
  • The effect of multipath is especially serious in urban area and sea surface where buildings and water reflect GPS signal. Multipath brings about the performance degradation on many GPS application because the presence of multipath causes the diminution of pseudorange measurement accuracy in turn position accuracy. In this paper, a multipath mitigation named weighted correlation method is implemented on software GPS receiver, in which the asymmetric correlation function is compensated by modifying the late correlation value. Asymmetry compensation is obtained as weighted sum of two correlators which have different early-late chip spaces. This structure is adopted to lessen the computation load lower keeping up performance similar to that. The performance of implemented multipath mitigation technique is evaluated using GPS signal and multipath signal generated by GPS signal generator and software GPS receiver. The test results show that the weighted correlation method gives hefter performance than the standard correlator and the narrow correlator.