• 제목/요약/키워드: Electrical Isolation

검색결과 617건 처리시간 0.028초

수소연료전지자동차용 절연저항 측정시스템 개발에 관한 연구 (Study on Development of the Isolation Resistance Measurement System for Hydrogen Fuel Cell Vehicle)

  • 이기연;김동욱;문현욱;김향곤
    • 전기학회논문지
    • /
    • 제60권5호
    • /
    • pp.1068-1072
    • /
    • 2011
  • Hydrogen Fuel Cell Vehicle(HFCV) is system that uses electrical energy of fuel cell stack to main power source, which is different system with other vehicles that use high-voltage, large-current. Isolation performance of this system which is connected with electrical fire and electrical shock is important point. Isolation resistance of electric installation is divided according to working voltage, it follows criterion more than $100{\Omega}$/VDC (or $500{\Omega}$/VAC) about system operation voltage in a hydrogen fuel cell vehicle. Although measurement of isolation resistance in a hydrogen fuel cell vehicle is two methods, it uses mainly measurement by megger. However, the present isolation resistance measurement system that is optimized to use in electrical facilities is unsuitable for isolation performance estimation of a hydrogen fuel cell vehicle because of limit of maximum short current and difference of measurement resolution. Therefore, this research developed the isolation resistance measurement system so that may be suitable in isolation performance estimation of a hydrogen fuel cell vehicle, verified isolation performance about known resistance by performance verification of laboratory level about developed system, and executed performance verification through comparing results of developed system by performance verification of vehicle level with ones of existing megger. Developed system is judged to aid estimation and upgrade of isolation performance in a hydrogen fuel cell vehicle hereafter.

수소연료전지자동차의 절연성능 평가방법에 관한 고찰 (Study on the Evaluation Method of Electrical Isolation Property for Hydrogen Fuel Cell Vehicle)

  • 이기연;김동욱;김향곤
    • 한국수소및신에너지학회논문집
    • /
    • 제22권6호
    • /
    • pp.810-818
    • /
    • 2011
  • This paper analyzed the suitability about the isolation performance criteria which was based on human impedance and effect of current in IEC 60479-1 on the safety of human being was examined. The method of evaluation by megger and DC voltmeter was analyzed. The differences of isolation performance according to design of high-voltage system were analyzed. The factors which affect the insulation performance were analyzed for HFCV, EV, HEV, etc. through analysis of the isolation performance evaluation method. Finally, design for improved isolation performance was proposed.

전기통신설비를 위한 옥내외 겸용 면진테이블 설계 (Design of a Seismic Isolation Table for both indoor and outdoor Electrical Communication Equipment)

  • 이춘세;안형준;이택원;손인철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.472-472
    • /
    • 2009
  • The safety of cultural properties, medical treatment and electrical communication equipments in a building was hardly considered against the earthquake induced vibration, while the integrity of the building structure has been taken into account through the resistant earthquake design. This paper presents design of a seismic isolation table for both indoor and outdoor electrical communication equipment. First of all, artificial earthquake waves compatible with floor and ground response spectra for electrical communication equipments are generated using previously recorded seismic waves. Two kinds of one-degree-of-freedom seismic isolation table systems: spring-linear damper and spring-friction damper systems are considered and their responses to artificial earthquake waves are simulated. Design parameter study for two seismic isolation tables are performed through simulations and a seismic isolation table for both indoor and outdoor electrical communication equipment is designed considering the simulation results.

  • PDF

방진재를 이용한 대형구조물의 철도 진동에 관한 실험적 연구 (Experimental Study on Railway Vibration Isolation of a Large Structure using Isolation Materials)

  • 류봉조;이홍기;구경완
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1286-1292
    • /
    • 2011
  • The paper deals with the vibration isolation of a large structure using an experimental technology. In the case of vibration isolation for the vicinity of a subway or a railroad station, most of vibration isolation techniques using isolation materials with high isolation efficiency only, have been applied. Therefore, the quantitative evaluation and design technologies are required for a vibration isolation of large structures. In this study, firstly, vibration characteristics due to train or subway are analyzed. Secondly, the performance of existing vibration isolation materials such as precision isolation material, elastomer is estimated through the experiments. Thirdly, the performance of a tire isolation material and its frame is tested and evaluated. Finally, it is shown that tire isolation materials can be applied to the vibration isolation or vibration reduction of large structures.

Fault Detection and Isolation using navigation performance-based Threshold for Redundant Inertial Sensors

  • Yang, Cheol-Kwan;Shim, Duk-Sun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2576-2581
    • /
    • 2003
  • We consider fault detection and isolation (FDI) problem for inertial navigation systems (INS) which use redundant inertial sensors and propose an FDI method using average of multiple parity vectors which reduce false alarm and wrong isolation, and improve correct isolation. We suggest optimal isolation threshold based on navigation performance, and suggest optimal sample number to obtain short detection time and to enhance detectability of faults little larger than threshold.

  • PDF

나노 입자 분리/분류를 위한 유전영동 칩 및 전극 패시베이션 기술 개발 (Development of dielectrophoresis chips and an electrode passivation technique for isolation/separation of nanoparticles)

  • 박민수;노효웅;강재운;이준영;박홍식
    • 센서학회지
    • /
    • 제30권2호
    • /
    • pp.119-124
    • /
    • 2021
  • Isolation and separation of biological nanoparticles, such as cells and extracellular vesicles, are important techniques for their characterization. Dielectrophoresis (DEP) based on microfluidic chips is an effective method to isolate and separate the nanoparticles. However, the electrodes of the DEP chips are electrolyzed by the electrical signals applied to the nanoparticles. Thus, the isolation/separation efficiency of the nanoparticles is reduced considerably. Through this study, we developed a microfluidic DEP chip for reliable isolation/ separation of nanoparticles and developed a passivation technique for the protection of the DEP chip electrodes. The electrode passivation process was designed using a hydrogel and the stability of the hydrogel passivation layer was verified. The fabricated DEP chip and the proposed passivation technique were used for the collection and dispersion of the fluorescent polystyrene nanoparticles. The proposed chip and the technique for isolation and separation of nanoparticles can be leveraged in various bioelectronic applications.

Simultaneous Fault Isolation of Redundant Inertial Sensors based on the Reduced-Order Parity Vectors

  • Yang, Cheol-Kwan;Shim, Duk-Sun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.2188-2191
    • /
    • 2005
  • We consider a fault detection and isolation problem for inertial navigation systems which use redundant inertial sensors. We propose a FDI method using average of multiple parity vectors which reduce false alarm and wrong isolation, and improve correct isolation. We suggest the number of redundant sensors required to isolate simultaneous faults. The performance of the proposed FDI algorithm is analyzed by Monte-Carlo simulation.

  • PDF

Two-Faults Detection and Isolation Using Extended Parity Space Approach

  • Lee, Won-Hee;Kim, Kwang-Hoon;Park, Chan-Gook;Lee, Jang-Gyu
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권3호
    • /
    • pp.411-419
    • /
    • 2012
  • This paper proposes a new FDI(Fault Detection and Isolation) method, which is called EPSA(Extended Parity Space Approach). This method is particularly suitable for fault detection and isolation of the system with one faulty sensor or two faulty sensors. In the system with two faulty sensors, the fault detection and isolation probability may be decreased when two faults are occurred between the sensors related to the large fault direction angle. Nonetheless, the previously suggested FDI methods to treat the two-faults problem do not consider the effect of the large fault direction angle. In order to solve this problem, this paper analyzes the effect of the large fault direction angle and proposes how to increase the fault detection and isolation probability. For the increase the detection probability, this paper additionally considers the fault type that is not detected because of the cancellation of the fault biases by the large fault direction angle. Also for the increase the isolation probability, this paper suggests the additional isolation procedure in case of two-faults. EPSA helps that the user can know the exact fault situation. The proposed FDI method is verified through Monte Carlo simulation.

Double Faults Isolation Based on the Reduced-Order Parity Vectors in Redundant Sensor Configuration

  • Yang, Cheol-Kwan;Shim, Duk-Sun
    • International Journal of Control, Automation, and Systems
    • /
    • 제5권2호
    • /
    • pp.155-160
    • /
    • 2007
  • A fault detection and isolation (FDI) problem is considered for inertial sensors, such as gyroscopes and accelerometers and a new FDI method for double faults is proposed using reduced-order parity vector. The reduced-order parity vector (RPV) algorithm enables us to isolate double faults with 7 sensors. Averaged parity vector is used to reduce false alarm and wrong isolation, and to improve correct isolation. The RPV algorithm is analyzed by Monte-Carlo simulation and the performance is given through fault detection probability, correct isolation probability, and wrong isolation probability.

An Eight-Element Compact Low-Profile Planar MIMO Antenna Using LC Resonance with High Isolation

  • Kwon, DukSoo;Lee, Soo-Ji;Kim, Jin-Woo;Ahn, ByungKuon;Yu, Jong-Won;Lee, Wang-Sang
    • Journal of electromagnetic engineering and science
    • /
    • 제16권3호
    • /
    • pp.194-197
    • /
    • 2016
  • An eight-element compact low-profile multi-input multi-output (MIMO) antenna is proposed for wireless local area network (WLAN) mobile applications. The proposed antenna consists of eight inverted-F antennas with an isolation-enhanced structure. By inserting the isolation-enhanced structure between the antenna elements, the slot and capacitor pair generates additional resonant frequency and decreases mutual coupling between the antenna elements. The overall size of the proposed antenna is only $33mm{\times}33mm$, which is integrated into an area of just $0.5{\lambda}{\times}0.5{\lambda}$. The proposed antenna meets 5-GHz WLAN standards with an operation bandwidth of 4.86 - 5.27 GHz and achieves an isolation of approximately 30 dB at 5 GHz. The simulated and measured results for the proposed antenna are presented and compared.