• 제목/요약/키워드: Electrical Impactor

검색결과 24건 처리시간 0.022초

나노 환경입자 측정용 전기적 임팩터의 설계 및 성능평가 (Design and Performance Evaluation of Electrical Impactor for Nano Environmental Aerosols)

  • 지준호;조명훈;배귀남;황정호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1417-1422
    • /
    • 2003
  • An electrical cascade impactor is a multistage impaction device to separate airborne particles into aerodynamic size classes using electrical method. We designed a real-time three-stage electrical low-pressure impactor, which is proper to nanometer sized environmental aerosols. Performance evaluation was carried out for stage 1 and 2. The monodisperse liquid dioctyl sebacate (DOS) particles were generated using condensation-evaporation followed by electrostatic classification using DMA (differential mobility analizer) for particles with diameters in the range of $0.04{\sim}0.8{\mu}m$. The evaluation of the electrical impactor is based on the use of two electrometers, one connected to the impaction plate of the impactor, and the other to the faraday cage as backup filter. The results showed that the experimental 50% cutoff diameters in the operation pressure were 0.53 and $0.12{\mu}m$ for stage 1 and stage 2. The effect of operation pressure on the cutoff diameter and the steepness of collection effcieicy curves is investigated.

  • PDF

미세입자 측정용 간이형 3단 전기적 저압 임펙터의 설계 및 성능평가 (Design and Performance Evaluation of a Portable 3-Stage Electrical Low Pressure Impactor(P-ELI) for Measurements of Submicron Aerosol)

  • 조명훈;지준호;박동호;배귀남;황정호
    • 대한기계학회논문집B
    • /
    • 제28권7호
    • /
    • pp.826-833
    • /
    • 2004
  • Cascade impactors are widely used to collect size classified aerosol. A major disadvantage of this instrument is the required long sampling time. Electrical low pressure impactor has been developed to overcome this disadvantage and to achieve real-time measurements on the particle size distribution. The instrument consists primarily of a corona charger, low pressure cascade impactor and multi channel electrometer. We designed and evaluated the performance of a potable 3-stage low pressure impactor using an electrical method. For the calibration of the impactor, monodispersed particles were generated using evaporation-condensation method followed by electrostatic classification using a DMA(Differential Mobility Analyzer). The collection efficiency curves of the stages can be determined by analysing the fraction of particles collected by each stage.

패러데이 케이지와 에어로졸 하전기의 설계 및 성능평가 (Design and Performance Evaluation of a Faraday Cage and an Aerosol Charger)

  • 지준호;배귀남;황정호
    • 대한기계학회논문집B
    • /
    • 제28권3호
    • /
    • pp.315-323
    • /
    • 2004
  • An electrical cascade impactor is a multi-stage impaction device to separate airborne particles into aerodynamic size classes using particle charging and electrical detection techniques. A Faraday cage and an aerosol charger, which are basic components of the electrical cascade impactor, were designed and evaluated in this study. The low-level current response of the Faraday cage was investigated with changing particle size and air flow rate by using sodium chloride (NaCl) particles. The response of the prototype Faraday cage was very similar to that of a commercial aerosol electrometer (TSI model 3068) within ${\pm}$5% for singly-charged particles. The response linearity of the prototype Faraday cage could be extended up to flow rate of 30 L/min. For the performance evaluation of the aerosol charger the monodisperse liquid dioctyl sebacate (DOS) particles, with diameters of 0.1∼0.8$\mu\textrm{m}$, were generated using spraying from an atomizer followed by evaporation-condensation process. Typical performance parameters of the aerosol charger such as P$.$n, wall loss, and elementary charges per particle were evaluated. The performance of the prototype aerosol charger was found to be close to that of the aerosol charger used in an electrical low pressure impactor (ELPI, Dekati).

서브마이크론 입자 측정용 저압 임팩터의 설계 및 성능평가 (Design and Performance Evaluation of a Low Pressure Impactor for Sampling Submicron Aerosols)

  • 지준호;조명훈;배귀남;황정호
    • 대한기계학회논문집B
    • /
    • 제28권3호
    • /
    • pp.349-358
    • /
    • 2004
  • A low pressure impactor is an impaction device to separate airborne particles into aerodynamic size classes at low pressure condition. We designed a two-stage low-pressure impactor to classify submicron sized environmental aerosols. Performance evaluation was carried out for stages 1 and 2 by using an electrical method. Monodisperse liquid dioctyl sebacate (DOS) particles were generated using evaporation-condensation process followed by electrostatic classification using a DMA (differential mobility analyzer). The test particles were in the range of 0.08∼0.8$\mu\textrm{m}$. For the evaluation of the impactor we used two electrometers; one was connected to the impaction plate of the impactor and the other was to the Faraday cage used as a backup filter. The effect of polydispersity of test aerosols on the performance was investigated. The results showed that the experimental 50-% cutoff diameters at each impactor's operation pressure were 0.53 and 0.187$\mu\textrm{m}$ for stages 1 and stage 2, respectively. The effects of operation pressure on the cutoff diameter and the steepness of collection efficiency curves were also investigated.

다공성 금속판을 이용한 전기적 임팩터의 평가 (Evaluation of an electrical impactor with porous metal substrate)

  • Jeong Jeong-Seon;Gwon Sun-Park;Lee Gyu-Won
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2002년도 추계학술대회 논문집
    • /
    • pp.276-277
    • /
    • 2002
  • One of drawbacks of the inertial impactor measurement is the required long sampling time (Keskinen et al., 1992). In a gravimetric method, an impaction substrate must be weighed and placed on the corresponding collection plate before being assembled. After sampling, the inertial impactor is disassembled and the collection plate is weighted again. The sampling time depends on the sampled particle mass because the collected particle mass must be sufficiently high to be measured by a sensitive microbalance. (omitted)

  • PDF

전기적 임팩터용 페러데이 케이지의 성능평가 (Performance Evaluation of the Faraday Cage for a Electrical Impactor)

  • 지준호;배귀남;황정호;이규원
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2000년도 추계학술대회 논문집
    • /
    • pp.117-118
    • /
    • 2000
  • 대전 입자의 거동은 입자의 제어 측면뿐만 아니라 입자의 측정에서 중요한 요소 중 하나이다. 특히, 입자를 실시간으로 측정하는 경우 입자의 대전량을 정밀하고 정확하게 측정하는 것은 측정 대상이 심하게 변할 때 매우 중요하다. 입자의 전기적 특성(대전량)을 이용하여 입경분포를 측정하는 장비로는 EAA(electrical aerosol analyzer), SMPS(scanning mobility particle sizer), ELPI(electrical low pressure impactor) 등이 있다. (중략)

  • PDF

전기적으로 분류 입경의 제어가 가능한 가상 임팩터을 이용한 대기 중 나노 입자의 분류 (Size Classification of Airborne Nanoparticles Using Electrically Tunable Virtual Impactor)

  • 권순명;김용호;박동호;황정호;김용준
    • 한국정밀공학회지
    • /
    • 제26권2호
    • /
    • pp.118-125
    • /
    • 2009
  • This paper reports the size classification of nanoparticles as well as electrical tuning techniques for the cut-off diameter and collection efficiency. Classifying particles < 100 nm in diameter is quite a technical challenge using a virtual impactor with the cut-off diameter being determined geometrically. However, the proposed virtual impactor can classify particles <100 nm and tune the cut-off diameter by electrically accelerating the particles. The cut-off diameter of the proposed device was tuned from 15 to 50nm.

실시간 미세입자 측정을 위한 다이오드형 코로나 하전기의 설계 및 성능평가 (Design and Performance Evaluation of a Diode Type Corona Charger for Real-Time Measurement of the Submicron Aerosol)

  • 조명훈;지준호;박동호;배귀남;황정호
    • 대한기계학회논문집B
    • /
    • 제28권9호
    • /
    • pp.1066-1074
    • /
    • 2004
  • With a diode corona charger, which is a component of ELPI(Electrical Low Pressure Impactor), aerosol particles are charged to make electrical detection possible before they are collected by the impactor. We designed and evaluated two cylindrical corona chargers, each of which had a central corona needle electrode. For the performance evaluation of each corona charger the polydisperse dioctyl sebacate(DOS) particles, with diameters of 0.1∼0.8 $\mu$m and NaCl particles, smaller than 0.1$\mu$m, were used. The particles were then led through an electrostatic classifier (TSI model 3081) to classify monodisperse aerosol with minimal size deviation. After evaluating the wall loss of the particles in the corona charger, we measured the product of penetration and number of charges, Pㆍn, to evaluate the corona charger efficiency at high positive voltages of 4, 5, 6 kV.

노즐 막힘이 미세 오리피스형 다단 임팩터의 입자 채취 성능에 미치는 영향 (Effect of Particle Clogging in Orifices on the Particle Collection Efficiency of a Micro-Orifice Impactor)

  • 지준호;배귀남;황정호
    • 대한기계학회논문집B
    • /
    • 제27권2호
    • /
    • pp.197-205
    • /
    • 2003
  • A cascade impactor is a multistage impaction device used to separate airborne particles into aerodynamic size classes. A micro-orifice impactor uses micro-orifice nozzles to extend the cut sizes of the lower stages to as small as 0.05 ${\mu}{\textrm}{m}$ in diameter without resorting to low pressures or creating excessive pressure drops across the impactor stages. In this work, the phenomenon of particle clogging in micro-orifice nozzles was experimentally investigated for a commercial micro-orifice uniform deposit impactor (MOUDI). It was observed, using an optical microscope, that the micro-orifice nozzles of the final stages were partially clogged due to particle deposition during the aerosol sampling. Therefore the pressure drops across the nozzles were higher than the nominal values given by the manufacturer. To examine the effect of particle clogging in micro-orifice nozzles, the particle collection efficiency of the MOUDI was evaluated using an electrical method for fine particles with diameters in the range of 0.1-0.6 ${\mu}{\textrm}{m}$. The monodisperse liquid dioctyl sebacate (DOS) particles were used as test aerosols. A faraday cage was employed to measure the low-level current of the charged particles upstream and downstream of each stage. It was found that the collection efficiency curves shifted to correspond to smaller orifice sizes, and the 50-% cutoff sizes were much smaller than those given by the manufacturer for the three stages with nozzles less than 400 ${\mu}{\textrm}{m}$ in diameter.