• Title/Summary/Keyword: Electrical Heating System

Search Result 408, Processing Time 0.054 seconds

A Study on the Baseline Load Estimation Method using Heating Degree Days and Cooling Degree Days Adjustment (냉난방도일을 이용한 기준부하추정 방법에 관한 연구)

  • Wi, Young-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.5
    • /
    • pp.745-749
    • /
    • 2017
  • Climate change and energy security are major factors for future national energy policy. To resolve these issues, many countries are focusing on creating new growth industries and energy services such as smartgrid, renewable energy, microgrid, energy management system, and peer to peer energy trading. The financial and economic evaluation of new energy services basically requires energy savings estimation technologies. This paper presents the baseline load estimation method, which is used to calculate energy savings resulted from participating in the new energy program, using moving average model with heating degree days (HDD) and cooling degree days (CDD) adjustment. To demonstrate the improvement of baseline load estimation accuracy, the proposed method is tested. The results of case studies are presented to show the effectiveness of the proposed baseline load estimation method.

A Study about Heating System of Methanol Heat-energy (메탄올 열에너지를 이용한 Heating 시스템에 관한 연구)

  • Cheang, Eui-hean;Lim, Joung-Min;Moon, Chae-Joo;Jung, Kyung-O;Kim, Gi-Woon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.206-209
    • /
    • 2007
  • 본 논문에서는 열전발전소자를 이용하여 전력을 발생시키는 장치를 개발하기 위한 초기단계의 연구이다. 기존의 열전발전소자가 사용되는 곳은 폐열 및 지열 등 에너지 효율을 높이기 위한 간접 장치로 이용되었으나 본 연구에서는 메탄올의 열에너지를 직접적으로 이용하여 전력발생이 가능한 장치를 개발하기 위하여 메탄올 열에너지를 이용할 수 있는 구조 및 반응조건에 대해 연구하였다.

  • PDF

Numerical Analysis in Unsteady State on variation of Diameter and Environmental Velocity of Carbon Heating Source (탄소발열체의 외부유속 및 직경변화에 대한 비정상상태에서의 수치해석적 연구)

  • Bae, K.Y.;Lee, Y.H.;Lee, S.Y.;Lee, C.S.;Kim, B.G.;Lee, S.H.
    • Journal of Power System Engineering
    • /
    • v.10 no.4
    • /
    • pp.25-30
    • /
    • 2006
  • This paper represents the numerical analysis in unsteady state on the variation of diameter and environmental velocity of carbon heating source. In general heating system, the oil and sheath heater is widely used, but these systems have many problems. So, the heating source with carbon ingredient has been researched in many country about manufacture, thermal and electrical properties. In this research, the carbon heating source was studied through numerical analysis on several conditions of unsteady state, heat generation, diameter and environmental velocity. The temperature distributions at steady state are appeared as a non-proportional linear pattern with variations of environmental velocity due to the Nesselt number with convective heat flux is proportioned to 0.805 of Reynolds number. As the radius is increasing, the temperature distributions is appeared the minus tilt because of the environmental condition is cooling by constant temperature. So, the correlation equation between temperature at steady state and environmental velocity was obtained.

  • PDF

Effect analysis of geothermal cooling and heating system (지열냉난방 시스템의 효과 분석)

  • Kim, Byeong-Kak;Kim, Yong-Hwan;Kim, Jong-Deug
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1146_1147
    • /
    • 2009
  • This experiment is significant because we can provide information by measuring effect of energy saving for whom plan to install a geothermal heat & cooling system. The result shows geothemal system can save about 50% of energy(heating : 35%, cooling : 60%) and we verified that when using curtain can help saving 4~12% of energy additionally.

  • PDF

Design of High Frequency Casting Machine for Dental using Induction Heating System (유도가열 시스템을 적용한 치과용 고주파 주조기 설계)

  • Song, Seung-Gun;Lim, Sang-Kil;Lee, Sang-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.79-87
    • /
    • 2012
  • Currently, The method to produce a brewing body for dentistry supplementation water produces a brewing body by fabrication, burying and it is heat wish in city gas and oxygen. It uses an original judgment found airplane the brewing body uses a spring of the back wait that melting temperature dissolved various alloys in by a blow pipe, and to generate centrifugal force and produces it. In addition, because it uses preheating to dissolve an alloy in general, it is hard to regulate the appropriate melting temperature of the alloy and brewing time and generates a brewing defect hereby same as gas industry and pinhole and shows the defect of the supplementation thing due to the super-heating. In this paper, We developed the high induction heating system which it could set brewing time,temperature and had durability and security,by the kind of the alloy to produce a high quality prosthetic thing brewing body.

Analysis of Annual Operation Status of Central Heating and Cooling System in a Public Office Building (공공건물 중앙식 냉난방시스템의 연간 운영 사례 분석)

  • Ra, Seon-Jung;Aum, Tae-Yun;Son, Jin-Woong
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.2
    • /
    • pp.175-180
    • /
    • 2020
  • The purpose of this study was to clarify precautions during the design and operation phases for energy reduction in a public office building. To check the operation status of the building, we measured the indoor temperature and humidity in the office space of the building installed central heating and cooling systems. And we analyzed these data and annual BEMS data. As a result, we found six problems related to decreasing system efficiency. Based on these, we presented the information to improve the efficiency of the system from the design and operation phase. Also, we present the need for a system to support the decision-making of operational managers in real-time for the energy efficiency of the building.

Analysis of Energy Performance & Energy Saving with Geothermal Heat Pump System Using TRNSYS Program in a Large Scale Shopping Store (TRNSYS 프로그램을 이용한 대형쇼핑매장 에너지성능해석 및 지열시스템을 도입하는 경우 에너지절약 특성분석)

  • Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.1
    • /
    • pp.47-56
    • /
    • 2015
  • Energy consumption in buildings is currently a real problem. That is why both assessment of energy performance and effective energy management including renewable energy system are essential. Thus, this paper focuses on a case study to analyze the energy performance and cooling & heating energy saving of a large scale shopping store in Daejeon city. The reference building is simulated by using TRNSYS dynamic simulation tool to examine its annual energy consumption. For annual energy analysis of building, one year energy consumption is surveyed in the field. The related study is carried out in large scale shopping store to investigate the energy consumption and energy use trend of heating, cooling, hot water, lighting, ventilation, equipments and other. The evaluation of energy performance of the geothermal heat pump system installed in a large scale shopping store is also analyzed by TRNSYS tool. From simulation results, it evaluated that the geothermal heat pump system is effective energy savings method in large scale shopping store.

Development of Heating and Cooling System with New Heat Exchange Cycle for High Efficiency and Peak Power Reduction Using Real time Constant Refrigerant Pressure Control (실시간 일정압력 제어기술을 적용한 냉난방장치의 피크부하 저감과 에너지 효율 향상을 위한 시스템 개발)

  • Choi, Sun-Young;Lee, Young-Kug;Choi, Myeong-Gwang;Choi, Tae-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.11
    • /
    • pp.53-58
    • /
    • 2015
  • Systemic heating and cooling air conditioning systems are popular in various industrial fields and even home. Recently, the rate of supply of this kind of multi-heat pump has been increased under ESCO financing supporting system. Generally the heat pumping system has a structural simplicity and easy installation benefits. and has good running efficiency under normal designed condition. But under extreme climate condition (over $+30^{\circ}C$, under $-10^{\circ}C$), this system exposes abnormal power consumption. It causes high progressive electric power rates and resultant peak power capacity of power plant. In this paper, a novel system concept of buffering refrigerant accumulator and constant pressure control system to relieve peak power load is proposed and this system's utility is verified with an prototype experimental system.

A Study on the Temperature Control System Design of Heat Pipe for Alternative Heating (대체 난방용 히트파이프 온도 제어 시스템 설계에 관한 연구)

  • Yoon S.A.;Shu J.S.;Cho K.J.;Cha I.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.908-912
    • /
    • 2003
  • The waste heat recovery system using heat pipe was tested for the consideration of developing the high-efficiency waste heat recovery technology. Heat pipe, a effective device that can quickly transfer large amounts of heat energy using the phase change of the working fluid and the characteristics of Electric Heater Bars used for alternative heating system are introduced In this paper. In order to increase energy efficiency, the system which controls the status of electric heater bars and the temperature of heat pipe installed has developed.

  • PDF