• Title/Summary/Keyword: Electrical Equipments

Search Result 862, Processing Time 0.028 seconds

Prediction of Lightning Damages and Maintenance of Distribution Line Equipments Using LPATS (LPATS를 이용한 배전설비 뇌해예측 및 보수운용)

  • Kim, Tae-Ik;Choi, Dong-Ho;Kim, Se-Ho;An, Jin-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1444-1446
    • /
    • 1999
  • In the calculation of lightning-induced voltage, it is used the various parameters obtained by LPATS being operated in KEPCO from 1995. Based on the lightning-induced voltage and the exact lightning position acquired by the developed program, we can predict the extent of damages in distribution systems. The result in this paper is very useful in finding fault location by lightning and performing rapid outage recovery and maintenance of distribution line equipments.

  • PDF

COMPUTER AIDED SCHECULING MODEL OF MATERIALS HANDSLING IN CHEMICAL ANALYSIS FLOOR

  • Fujino, Yoshikazu;Motomatu, Hiroyoshi;Kurono, Shigeru
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.31-34
    • /
    • 1995
  • The automated chemical analysis shop floor are developed for the environmental pollution problems in our chemical analysis center. This shop floor have the several equipments include weight, pour, dry, heater, boiler, mixture, spectroscopy etc. And the material handling components are made up by the stored stack, conveyore, turntables, robot etc. Computer simulation has been an important tool for these complete design problem. We have designed the arangement of chemical equipments and material flow systems by using the simulator "AutoModII". "AutoMoII" is one of the advanced simulator, CAD-like drawing tools with a powerful, engineering oriented language to model control logic and material flow. The result is the modeling of the chemical analysis system in accurate, three dimensional detail. We could designed the set able layout and scheduling system by using the AutoMoII simulator. AutoMoII simulator.

  • PDF

Electrical Strength of the Insulating Materials for High-Tc Superconducting Devices

  • Bae, Duck-Kweon;Kim, Chung-Hyeok;Oh, Yong-Cheul;Kim, Jin-Sa;Shin, Cheol-Gee;Song, Min-Jong;Lee, Joon-Ung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.149-150
    • /
    • 2005
  • According to the trend for electric power equipment of high capacity and reduction of its size, the needs for the new high performance electric equipments become more and more important. On of the possible solution is high temperature superconducting (HTS) power application. Following the successful development of practical HTS wires, there have been renewed activities in developing superconducting power equipment. HTS equipments have to be operated in a coolant such as liquid nitrogen ($LN_2$) or cooled by conduction-cooling method such as using Gifford-McMahon (G-M) cryocooler to maintain the temperature below critical level. In this paper, the dielectric strength of unfilled epoxy and filled epoxy in $LN_2$ was analyzed. The filled epoxy composite not only compensates for this fragile property but enhances its dielectric strength.

  • PDF

Power Quality Measurement System of using PLC (전력선통신을 이용한 전력품질 측정시스템)

  • Hong, Duc-Pyo;Lee, Jin-Mok;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.90-92
    • /
    • 2005
  • As the developing of industry, the nonlinear equipments as inverter, converter, SMPS(Switching Mode Power Supply) and motor have been increased. But the sensitive electronic loads to the power quality, such as computer's and other electronic equipments, have been spreaded out very fast. Thus, the power quality (PQ) problems and the real time power quality monitoring (PQM) are one of the important issues industry and building area for the intelligent control of the systems. One of them, PQM using PLC(Power Line Communication) have good merits that can send and receive the PQ information without any new network line. This paper presents the PQM hardware and software to monitor the PQ information by using PLC that meets the categories of IEEE Std. 1159.

  • PDF

Developement of Web-Based Circuit-Constructible remote Laboratory (회로구성이 가능한 인터넷 기반의 원격 실험실 구축에 관한 연구)

  • Joung, Soung-Hun;Kim, Ho-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2603-2605
    • /
    • 2001
  • In this paper, we introduce the concept and construction of a web-based bidirectional remote laboratory system. In this configuration, students build and test circuits using internet at home, and the circuit components and experimental equipments at the school are interconnected following student's design. This means that it is possible to choose components, build circuits, connect experiment equipments, control the equipment. and receive measurement results at home in real-time. Labview and Java are used to control this system efficiently and to provide user-friendly environments. Computer-based function generator, DMM, and oscilloscope are used and switch module is used to change interconnections. It was found that a system adopting computer-based instruments, which include PXI/CompactPCI modules and PC plug-in board, provide better performance than that adopting stand-alone instruments connected with GPIB. It is believed that, if this system is installed, the real experiments, not the virtual experiments based on simulation, can be done at home effectively, resulting in revolutional change in engineering education.

  • PDF

DB Configuration Method for Optimal Design of Building System (건축전기설비의 최적설계를 위한 DB 구성방안)

  • Hwang, Sung-Wook;Jung, Jae-Yoon;Kim, Jung-Hoon;Cho, Sung-Won
    • Proceedings of the KIEE Conference
    • /
    • 2005.11c
    • /
    • pp.2-4
    • /
    • 2005
  • This paper includes level classification of electrical equipments and basic research of database system for optimal design of electrical equipments. Data for building usage, area, input voltage and type, transformer were surveyed and analyzed. Additionally, the environment of high-efficient end-use was investigated for application to design building system. For the constmction of database system, the type and size of data was analyzed.

  • PDF

Design of a bluetooth-based interactive control network

  • Kwak, Jae-Hyuk;Lim, Joon-Hong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.922-925
    • /
    • 2004
  • Bluetooth technology is essentially a method for wireless connection of a diverse set of devices ranging from PDAs, mobile phone, notebook computers, to another equipments. The bluetooth system supports both point-to-point connection and point-to-multipoint connections. In point-to-multipoint connection, the channel is shared among several bluetooth devices. Two or more devices sharing the same channel form a piconet. There is one master device and up to seven active slave devices in a piconet. The radio operates in the unlicensed 2.45GHz ISM band. This allows users who travel world-wide to use bluetooth equipments anywhere. Since the link is based on frequency-hop spread spectrum, multiple channels can exist at the same time. The Bluetooth standard has been suggested that Bluetooth equipments can be used in the short-range, maximum 100 meters . It has been defined that the time takes to setup and establish a bluetooth connection among devices is 10 seconds. It is a long time and may be a cause to lose a chance of finding other non-fixed devices. We propose a routing protocols for scatternets which can be used to control a mobile units(MUs) in this network. The proposed routing protocol is composed of two kinds of bluetooth information, access point(AP) and MU.

  • PDF

A Voltage Control Technique of Line-Interactive DVR Using 7-Level H-Bridge Inverter (7-레벨 H-Bridge 인버터를 이용한 Line-Interactive DVR의 전압제어)

  • Kang, Dae-Wook;Hyun, Dong-Seok;Lee, Woo-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.4
    • /
    • pp.705-715
    • /
    • 2007
  • Recently, the interest on power quality has been hot issue because the equipments cause voltage disturbance and have become more sensitive to the voltage disturbance. Additionally, the reseach on power electronic equipments applying to the high power has been increased. This paper deals with Line-Interactive Dynamic Voltage Restorer(LIDVR) system using 7-Level H-Bridge inverter, which is one of the solutions to compensate the voltage disturbance and to increase the power of equipments. The LIDVR has the following advantages comparing to the DVR with the series injection transformer. It has the power factor near to unity under the condition of normal source voltage, can compensate the harmonic current of the load and the instant interruption, and has the fast response. First, the construction, the operation mode and algebraic modeling of LIDVR are reviewed. And then the voltage control algorithm is proposed to get the sinusoidal load voltage with constant amplitude. Finally, simulation and experiment results verify the proposed LIDVR system.