• 제목/요약/키워드: Electrical Equipments

검색결과 862건 처리시간 0.028초

지하철 역내 가스 검출 원격 모니터링 시스템 구현 (Development of a remote monitoring system for gas detection at the subway station)

  • 박용만;김희식;김규식;이문규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.439-441
    • /
    • 2007
  • The seoul metropolitan subway has installed 8 lines and about 500 stations to transport 5 million passengers everyday. The underground air pollution level in the subway stations is very severe status, which is very harmful to the commutators and its personals. Although subway roles as such a massive and huge transportation system, the subway doesn't adapt yet any real-time air monitoring system. They have only some hand-held type detector equipments for monitoring air pollution. Therefore subway passengers are exposed to the harmful air pollution environment. The most harmful environmental parameters among the air pollution are known as the dust and sound noise dB level in the subway station. Because the dust is consisted of very small particles, we can't see them easily in dark condition on the platform, but it is very harmful. The monitoring system for air pollution is developed using embedded system attached with 6 different environmental sensors. This system monitors air pollution of dust sound noise, gas, temperature, humidity, inflammable gas, toxic gas in the subway ?station. The sensor unit of the ARM-CPU board and sensor transmits real time environmental data to the main server using Zigbee wireless communication module and TCP/IP network. The main control server receives and displays the real-time environmental data, and it send alarms to the personals when high level value.

  • PDF

KSLV-I 킥 모터 지상연소시험에서의 진동 및 충격 계측 (Vibration and Shock Measurement of KSLV-I Kick Motor on the Ground Test)

  • 오준석;김정용;노웅래;은희광;임종민;문상무
    • 항공우주기술
    • /
    • 제8권2호
    • /
    • pp.98-104
    • /
    • 2009
  • 소형 위성 발사체 KSLV-I은 2단의 추진기관으로 고체 킥 모터(Kick Motor)를 사용한다. 킥 모터의 연소 중에는 진동 및 충격이 발생하게 된다. 킥 모터는 2단 전자 탑재물 베이의 하단에 연결되어 있고 연소 중 발생하는 진동 및 충격이 킥 모터의 동체를 통해 전자탑재 베이로 전달 될 수 있다. 전자 탑재물로 전달되는 진동 및 충격의 크기가 큰 경우 전자탑재물의 오작동을 유발할 수 있다. 따라서 킥 모터의 연소 중 발생하는 진동, 충격의 사전검증이 필요하다. 본 연구는 킥모터의 지상 연소 시험을 통해 연소 중 발생하는 진동을 계측하고 이를 바탕으로 랜덤 진동 및 충격 응답 스펙트럼을 분석하였다.

  • PDF

EMI Filter의 고성능화에 관한 연구 (Design of EMI Filter with High Performance)

  • 구동우;배대환;송재만;김동일
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2001년도 춘계종합학술대회
    • /
    • pp.240-243
    • /
    • 2001
  • 전자산업 및 전파총신기숙의 급속한 발달에 따라 인간의 생활은 풍요로워졌다. 또한 전기, 전자장치의 경량화 소형화, 고속화와 광대역화가 가능하게 되고, 또한 이득을 적은 구동 에너지로도 동작시킬 수 있게 되었다. 반면에 이들은 인위적인 제어가 어려운 자연 현상을 원인으로 하는 미소한 전자파장해에도 민감하게 감응하여 오동작을 일으키기 쉽고, 또 많은 전기, 전자장치가 사회 각 분야에 보급됨에 따라 전자파 밀집도가 증가하여 전자파환경을 나쁘게 만드는 경우가 늘어나게 되었다. 열악한 환경에 설치된 기기가 원래의 목표대로 동작치 않아 사회에 혼란을 일으키거나, 인체장해의 가능성이 제시되고 있는 등 많은 문제점들이 나타나고 있다 이에 대한 규제를 위하여 CISPR, FCC, ANSI등에 의한 표준규격이 제정되어 발효되고 있다. 본 논문에서는 기존의 EMI 필터보다 150 kHz∼30 MHz 대역에서 10 dB∼20 dB 감쇠 효과를 가지는 개선된 EMI 필터를 설계 제작하여 전자파 노이즈가 내부 또는 외부로 유출ㆍ입 되는 것을 방지하고 부하 변동에 따라 특성의 변화가 없는 EMI 멀티탭으로 설계ㆍ제작하였다.

  • PDF

복합형 초전도 한류기의 한류특성에 따른 계통 적용성 검토 (Investigation of Network Application of the Hybrid SFCLs)

  • 최원준;심정욱;박권배;김영근;오일성;현옥배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.223-225
    • /
    • 2008
  • In order to apply SFCLs into electric power systems, the urgent issues to be settled are as follows, such as initial installation price, operation and maintenance cost due to ac loss of superconductor and the life of cryostat, and high voltage and high current problems. We designed novel hybrid SFCLs which combine superconductor and conventional electric equipments including a vacuum interrupter, an electro-magnetic contactor and a current limiting reactor. The main purpose of the hybrid SFCL is to drastically reduce total usage of superconductor by adopting current commutation method by use of the superconductor and the fast switch. According to protective coordination and performance, we investigated two concepts of Hybrid SFCLs. First is a half cycle fault current limitation type and second is a non-half cycle fault current limitation type. We concluded that the non-half cycle fault current limitation type is batter than the other.

  • PDF

Ni이 첨가된 $MnO_2$ 산화물전극의 전자상태 계산 (Calculation of Electronic State of MnO2 Oxide Electode Having Ni Additive)

  • 이동윤;김봉서;송재성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1515-1517
    • /
    • 2002
  • $MnO_2$ is used for the oxide electrode of electrochemical equipments because of its good electric conductivity and low oxygen overpotential. The effect of additives on the properties of $MnO_2$ has been investigated to enhance the electric conductivity and the stability in an acid solution. In this research, the effect of Ni addition on ${\beta}-MnO_2$ was studied by the theoretical quantum chemical method. The calculation was carried out by the discrete variation $X{\alpha}$ method, which is a sort of the first principle method and use Hatre-Fock-Slater approximation. The electron energy level, the density of state, the bond overlap population, the charge density distribution and the net ionic transfer between cations and anions were calculated and discussed. The used cluster model was $(Mn_{10}NiO_{44})^{-44}$.

  • PDF

정보통신설비에 대한 뇌서지 보호소자의 효과적인 설치기법 (An Effective Installation Method of Lightning Protective Devices for Information and Communication Facilities)

  • 이복희;강성만;엄주홍;이동문;이수봉;정동철;안창환;전덕규;이경옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1754-1756
    • /
    • 2002
  • This paper deals with an effective installation method of lightning protective devices for information and communication facilities. Due to the potential difference between grounding of the AC power lines and communication lines, the equipments connected to the communication lines are easily damaged by lightning surges. So we have examined the behaviors of surge protective devices against lightning surges from the AC power lines and signal lines, and the coordination effects of SPD installation method were investigated. As a result, it was confirmed that the bypass arrester method and common grounding method were very effected.

  • PDF

Micro SMES를 이용한 전원공급 안정화장치 시뮬레이션을 위한 PSCAD/EMTDC 컴포넌트 모델링 (Component Modeling of Micro SMES Based Design of Stabilizer Simulation for Power Supply using PSCAD/EMTDC)

  • 김봉태;박민원;성기철;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.228-230
    • /
    • 2002
  • Recently, electric power reliability of our country has been improved. However, there are still remaining problems which are short-duration variations like instantaneous and momentary interruption and voltage sag by nature calamity ; typhoon, lightning, snow, etc. Besides, power quality ; harmonics, caused by using power electronics equipments, become a hot issue Malfunction of controller and stop machinery, and losing the important data are caused by poor power quality at a couple of second. Due to those, UPS, which is made up battery, has being used, but there are several disadvantages ; long charge and discharge time, environmental problem by acid and heavy metal, and short life time. As generally know, micro-SMES is a method to settle those mentioned. However, there need huge system apparatuses in order to verify the effect of system efficiency and stability considering the size of micro-SMES, the sort of converter type, and various conditions ; inner temperature, magnetic field, quench characteristic of micro-SMES, and etc. In this paper, in order to bring the mentioned above to a settlement, a micro-SMES is modeled with characteristics of micro-SMES is interfaced to EMTOC program using Fortran program interface method. We obtained hopeful answers and made the simulation model of micro SMES.

  • PDF

보조 전류원 커패시터 뱅크를 가지는 LC공진회로를 이용한 아크발생 실험장치에 관한 연구 (Arc Generation Facility with Auxiliary Current Source Using LC Resonance Circuit)

  • 강종성;박홍태;이방욱;서정민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1054-1056
    • /
    • 1999
  • It is necessary to install the arc generation facility to obtain the important technology for the design of breakers and switches, and the improvement of their performance and reliability. With this facility it is possible to study the characteristics of Arc in air/gas/vacuum insulation environment. The arc generation facility briefly consists of capacitor bank which can charge enormous energy, an air-core reactor, and several measurement equipments. This facility can simulates the arc phenomena in breakers and switches by means of generating high currents. In order to the protect electrode damage during the arcing time in arc extinguishing chamber, we installed auxiliary current source in addition to main capacitor bank, This auxiliary current source produces relatively small arc between electrodes before high current generation by main capacitor bank. Therefore it is possible to observe and measure the arcing phenomenon without damage of electrodes.

  • PDF

Experimental Study on the Enhancement of Particle Removal Efficiency in Spray Tower Scrubber Using Electrospray

  • Kim, Hyeok-Gyu;Kim, Hong-Jik;Lee, Myong-Hwa;Kim, Jong-Ho
    • Asian Journal of Atmospheric Environment
    • /
    • 제8권2호
    • /
    • pp.89-95
    • /
    • 2014
  • There have been a lot of efforts to keep permissible emission standards and to reduce the amount of emitted air pollutants. There are several air pollution control equipments, however, wet scrubber is used to remove particulate matters and gaseous pollutants simultaneously, even if it has low collection efficiency in the particle size less than $5.0{\mu}m$. To overcome this problem, we introduced a spray tower scrubber with an electrospray system which a high voltage was indirectly applied. We found that collection efficiency of fine particles in the electrospray system was improved by increasing electrical field strength and the ratio of liquid-gas flow rate (from 41% to 84% for $0.3{\mu}m$ particles). In addition, a number of small droplets generated from an electrospray system led high collection efficiency, resulting from electrostatic attraction between droplets and particles and higher collision frequency. Therefore, we can conclude that the introduction of an electrospray system is quite effective to increase the particle removal efficiency of a spray tower scrubber.

보안성을 겸비한 전이중방식의 다중레벨 통신드라이브에 관한 연구 (A Study on Multilevel Communication Drive of Full-Duplex Method with Security)

  • 조수억;박성미
    • 한국산업융합학회 논문집
    • /
    • 제23권1호
    • /
    • pp.41-48
    • /
    • 2020
  • Currently, the industry uses MODBUS communication method using RS485 as a communication method used when constructing distributed equipment and networks. However, this method has a rather good transmission and reception distance, but has a disadvantage of being a half-duplex communication method. Therefore, there is a great need for a full-duplex communication method that can simultaneously transmit and receive two-wire communications. Therefore, in this paper, we propose a new communication hardware equipment that can implement full-duplex communication method by communication signal level to overcome the disadvantage of communication speed. The proposed communication hardware is a structure that can transmit and receive at the same time on the same communication line in two equipments communicating in a two-wire system. The characteristic of this communication hardware is that the transmitter generates two-level signal for data transmission, but the receiver generates three-level electric signal according to the status of the transmission data generated by the receiver. The data transmission signal information of the receiver is present at the same time. Therefore, the receiving side can analyze the received signal based on the information on the current transmission signal and can analyze the signal only in the two communicating devices, so it can be seen that the communication security is very excellent.