• Title/Summary/Keyword: Electrical Characteristic Measurement

Search Result 367, Processing Time 0.026 seconds

Measurement of anchoring strength of a photo-polymer for LC alignment

  • Hahn, Soon-Koo;Kang, Dae-Seung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.619-621
    • /
    • 2003
  • We have presented in the paper preliminary results on physical characteristic parameters of a photopolymer LPPF 301 CP. The weak azimuthal anchoring energy (${\sim}5.0{\times}10^{-6}J/m^2$) of a photopolymer was measured by using a simple optical method. High pretilt up to $30^{\circ}$ has been achieved in the photoaligned cell by irradiating an obliquely incident UV light.

  • PDF

A Study of PMD Characteristic in Single Mode Optical Fiber (단일모드 광섬유에서의 편광모드분산 특성에 관한 연구)

  • 이청학;김성탁;김기대;박대희
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.201-204
    • /
    • 1999
  • Polarization mode dispersion (PMD) restrict the bend-width of single mode optical filer, and it is important parameter in the optical fiber having long-length. Although fiber has perfect circular symmetry, fiber bending, twisting and laws governing manufacture cause additional Polarization mode dispersion. The effect of polarization mode dispersion in general single mode fiber of long length is discussed in this paper. Measurement of PMD with random mode coupling were conducted in two kind of fibers using different laws governing manufacture and interferometric method.

  • PDF

Characteristics of Optical Current Sensors by Sensor Design

  • Kim, Young-Min;Park, Jung-Hwan;Lee, Kwang-Sik;Kim, Jung-Bae;Park, Won-Zoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.4
    • /
    • pp.80-87
    • /
    • 2007
  • This paper will suggest that the 1 cross orthogonal loop type sensor improves on the orthogonal loop form sensor-head, which is available a calibration of the linear birefringence, when a fiber optic current sensor was composed. An output characteristics of the 1 cross orthogonal loop form, a general closed loop form, the orthogonal loop form are compared by the IEC(International Electrotechnical Commission) 60044-8 standard, and the state of polarization is compared with three forms. As a result, when the closed loop form was changed to the orthogonal loop form, retardation decreased 15.3[%]. When the closed loop form was changed to the 1 cross orthogonal loop type, the retardation decreased 33.8[%]. As a result of the Faraday Effect measurement, the 1 cross orthogonal loop form has the highest output characteristic and the lowest error ratio. It met the 0.5 class of the IEC 60044-8 standard. Thus, in application of the 1cross orthogonal loop form, the possibility to develop high reliability fiber optic current sensors that have a high output and stable error ratio rises is increased.

Real-Time Maximum Power Point Tracking Method Based on Three Points Approximation by Digital Controller for PV System

  • Kim, Seung-Tak;Bang, Tae-Ho;Lee, Seong-Chan;Park, Jung-Wook
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1447-1453
    • /
    • 2014
  • This paper proposes the new method based on the availability of three points measurement and convexity of photovoltaic (PV) curve characteristic at the maximum power point (MPP). In general, the MPP tracking (MPPT) function is the important part of all PV systems due to their power-voltage (P-V) characteristics related with weather conditions. Then, the analog-to-digital converter (ADC) and low pass filter (LPF) are required to measure the voltage and current for MPPT by the digital controller, which is used to implement the PV power conditioning system (PCS). The measurement and quantization error due to rounding or truncation in ADC and the delay of LPF might degrade the reliability of MPPT. To overcome this limitation, the proposed method is proposed while improving the performances in both steady-state and dynamic responses based on the detailed investigation of its properties for availability and convexity. The performances of proposed method are evaluated with the several case studies by the PSCAD/EMTDC$^{(R)}$ simulation. Then, the experimental results are given to verify its feasibility in real-time.

Optimization Analysis for Homogeneous Field Structure of GTEM-CELL (GTEM-CELL의 균일한 필드구조를 갖기위한 최적화 분석)

  • Kim, Jong-Seong;Seo, Kang;Jeong, Seong-IL;Lee, Han-Young;Lee, Jong-Arc
    • Journal of IKEEE
    • /
    • v.7 no.2 s.13
    • /
    • pp.218-222
    • /
    • 2003
  • Even if using the standard field test which radiation of electric wave and measurement test equipment there are difficult thing that building test equipment. so, we can use the substitution test field. In this paper, for optimization analysis for homogeneous field structure of GTEM-CELL (Giga hertz Transverse Electro Magnetic Cell) that calculate electromagnetic field characteristic for variable of each structure and characteristic impedance inner conductor.

  • PDF

Model Parameter Determination of Industrial Co-generator Model Parameters through Filed Measurement (현장 계측을 통한 산업용 열병합 발전설비 모델 파라미터 결정)

  • Kim, Hak-Man
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.159-165
    • /
    • 2007
  • This paper presents a method for the derivation of model parameters of a co-generation system using data measured through on-site generator characteristic testing and validates its model parameters. Dynamic models such as generator, excitation system, and turbine/governor are mainly dealt in this paper. For the purpose of validation of derived model parameters, the measured results are compared with simulation results. The comparisons between measured results and simulation results show good match.

Resistivity Characteristic of Block in Structure Grounding (구조체 접지에서 블록의 저항률 특성)

  • Koh, Hee-Seog;Kim, Ju-Chan;Jung, Man-Gil;Kim, Sung-Sam
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.280-281
    • /
    • 2006
  • This paper was analyzed fundamental about electrical characteristic of concrete to practical use base of building as Substitution Ground Electrode and Artificial Ground Electrode. 1) Gravel or Sand has a function that makes increase Resistivity of Concrete and Cement has a function that makes decrease Resistivity of Concrete. 2) Moisture Increase Work is so hard because of dry of Block but the Resistivity was decreased when the moisture of Concrete Block was gradually increased. 3) According to the measurement result of moltar and concrete block, ratio relation of Resistance and Resistivity of each block was thirty-fold difference.

  • PDF

The Improvement of Magnetic Properties of CoCr Thin Film for Perpendicular Magnetic Recording Media (수직자기기록매체용 CoCr박막의 자기적 특성 개선에 관한 연구)

  • 공석현;손인환;최형욱;최동진;김경환
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.419-422
    • /
    • 1999
  • We prepared CoCr thin film for perpendicular magnetic recording media by facing targets sputtering system(FTS system) which can deposit a high quality thin films in plasma-free state and wide range of working pressure. In this study, we investigated that the effect of sputtering condition , that Argon gas pressure and substrate temperature, on magnetic and crystallographic characteristic of CoCr thin film as well as the variation perpendicular coercivity in changing of film's thickness. Crystallographic and magnetic characteristic of prepared thin films were evaluated by x-ray fractometry(XRD), vibrating sample magnetometer(VSM) and kerr hysteresis loop measurement.

  • PDF

Analysis of Unequal Electric Field by Moving Metal Particle in GIS Using SNM (공간회로망법을 이용한 GIS 내부의 움직이는 도체이물질에 의한 불평등전계 해석)

  • Park, Gyeong-Su;Choe, Seong-Yeol;Go, Yeong-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.2
    • /
    • pp.68-73
    • /
    • 2002
  • In compared with air insulated switchgear, GIS has a high efficiency and confidence. Insulation method using $SF_6$ gas has a very excellent insulation characteristic for high voltage equipment but has a characteristic that insulation heredity is changed for internal unequal electric field. So analysis of time varying electromagnetic field in GIS is very important for structure design and trouble diagnosis process. In compared with established method, the SNM(Spatial Network Method) in this Paper can observe variation of electromagnetic field with real time and get result very similar to measurement. In order to Know variation of electromagnetic field distribution in fast moving particle, we make used of SNM.

SOC Estimation Based on OCV for NiMH Batteries Using an Improved Takacs Model

  • Windarko, Novie Ayub;Choi, Jae-Ho
    • Journal of Power Electronics
    • /
    • v.10 no.2
    • /
    • pp.181-186
    • /
    • 2010
  • This paper presents a new method for the estimation of State of Charge (SOC) for NiMH batteries. Among the conventional methods to estimate SOC, Coulomb Counting is widely used, but this method is not precise due to error integration. Another method that has been proposed to estimate SOC is by using a measurement of the Open Circuit Voltage (OCV). This method is found to be a precise one for SOC estimation. In NiMH batteries, the hysteresis characteristic of OCV is very strong compared to other type of batteries. Another characteristic of NiMH battery to be considered is that the OCV of a NiMH battery under discharging mode is lower than it is under charging mode. In this paper, the OCV is modeled by a simple method based on a hyperbolic function which well known as Takacs’s model. The OCV model is then used for SOC estimation. Although the model is simple, the error is within 10%.