• 제목/요약/키워드: Electrical Characteristic Measurement

검색결과 367건 처리시간 0.028초

동맥맥파의 특징점 검출 알고리즘 개선에 관한 연구 (Improvement of a characteristic point detection algorithm of arterial pulse)

  • 전영주;이전;김종열;이낙범;임재중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1916-1917
    • /
    • 2007
  • Aortic AIx(augmentation index) has been used to measure aortic stiffness and evaluate ventricular load quantitatively. Algorithm for the detection of augmentation point gradually increases the differential order to detect inflection point rather than detects the distinctive point that appears after a specific time. Developed algorithm for AIx is proved to provide more accurate results than the ones developed by previous studies with the deviation from $-11.5{\pm}14.34$ points to $-3.75{\pm}1.26$ points. Results could provide the basis for the measurement of aortic stiffness using easily-measurable radial artery pulse waves, and could be extended to develop a system for early diagnosis of various vascular diseases.

  • PDF

3상 다이오드 정류기의 고조파 해석 및 LISN을 이용한 노이즈 측정에 관한 연구 (Harmonic Analysis of Three-Phase Diode Rectifier and Measurement of Conducted EMI Emission Using LISN)

  • 채영민;최규하;목형수;이은웅;홍순찬;백수현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.212-215
    • /
    • 1995
  • In this paper, The characteristic of Harmonic spectrum is studied for generally used three-phase diode rectifier. and filter design criteria is showen in the sense of THD, DPF, and PF. As the becoming of Automative and informative era, the demand of critical and stable control becomes more and more important. But much EMI emissions are generated for more critical and stable control in power electronic system these EMI emissions can be measured using LISN(Line Impedance Stabilization Network). So we are to investigate the behavior of Conducted EMI emission in Diode Rectifiers using LISN in frequency domain.

  • PDF

실외 자기유도 무인운반차를 위한 자기 위치측정 장치 개발 (Development of Magnet Position Device for Outdoor Magnet Guidance Vehicle)

  • 조현학;김성신
    • 한국지능시스템학회논문지
    • /
    • 제24권3호
    • /
    • pp.259-264
    • /
    • 2014
  • 본 연구는 자기 홀 센서의 특성으로 인해 실내 환경에서만 이용이 되었던 자기/자기-자이로유도 타입의 무인운반차를 실외 환경에서도 적용이 가능하도록 실외 주행용 자기 위치측정 장치를 설계 및 제작하는 것이다. 현재 이용되고 있는 자기 위치측정 장치는 측정 높이가 30mm로 바닥 환경이 고르고 평평한 실내 환경에 적합한 구조이다. 하지만 바닥 환경이 울퉁불퉁하거나 불균형적인 실외환경에 이용되는 무인운반차에는 부적합하다. 그 이유는 무인운반차 서스펜션이 부착되게 되고, 이 때 자기 위치측정 장치의 부착높이가 30mm 이하로 무인운반차에 가해진 충격으로 인해 장치와 바닥과의 충돌이 발생하게 되면 장치가 파손되기 때문이다. 따라서 실외 자기유도 무인운반차에 적용하기 위해서는 100mm 이상의 측정 높이를 가지는 자기 위치측정 장치가 필요하다. 현재 자기위치측정 장치의 성능 향상 및 개발에 관련된 다양한 연구들이 진행되었지만, 다양한 자기 홀 센서를 분석하여 본 논문에서는 자기위치측정 장치를 설계 및 제작하였고, 자기 홀 센서의 특성 정보를 이용한 특성 함수를 이용해 자성체의 위치를 검출하였다. 실험을 위하여 알루미늄을 이용한 실험 장비를 제작하였으며, 제안된 자기 위치측정 장치를 이용하여 실험한 결과 위치측정 정밀도 오차는 10mm 이하이고, 측정 높이는 평균 150mm 로 실외 자기유도 무인운반차에 적합한 것을 확인하였다.

광대역 초음파 변환기를 위한 전기 임피던스 정합 연구 (Study on Electrical Impedance Matching for Broadband Ultrasonic Transducer)

  • 김건우;김기복;백광세
    • 비파괴검사학회지
    • /
    • 제37권1호
    • /
    • pp.37-43
    • /
    • 2017
  • 초음파탐상법을 이용하여 마이크로미터의 크기 작은 결함을 검출하기 위해서는 높은 공진주파수와 큰 분해능의 초음파 변환기가 필요하다. 초음파 변환기의 공진주파수와 분해능은 변환기에 사용된 압전소자의 두께, 후면재 및 탐상 시스템 간의 전기 임피던스 정합과 밀접한 관련이 있으며, 이 중 전기 임피던스 매칭은 초음파 변환기와 초음파탐상 시스템 사이의 서로 다른 입 출력단을 연결하는 과정에서, 두 연결단의 전기적 임피던스 차이에 의한 에너지 반사와 손실을 줄이는 중요한 역할을 한다. 임피던스 정합에서 흔히 많이 사용하는 방법은 LC-정합회로이다. 이러한 LC-정합을 통해 탐상 시스템과 초음파 변환기의 전기 임피던스를 $50{\Omega}$으로 맞추어 두 연결단 사이의 임피던스 차이를 보정해 줌으로서 초음파 변환기에서 발생되는 전기신호의 손실을 줄 수 있다. 본 연구에서는 15 MHz의 공진주파수를 가지는 광대역 수침형 초음파 탐촉자를 제작하고 광대역 특성을 갖는 초음파 변환기를 위한 LC 임피던스 정합법을 적용하였다.

통신용 부품제작을 위한 유기초박막의 전자특성에 관한 연구 (Photo Displacement Properties of Nano structure Organic Ultra Thin Films)

  • 송진원;조수영;김영근;김형곤;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집
    • /
    • pp.27-32
    • /
    • 2004
  • Maxwell displacement current (MDC) measurement has been employed to study the dielectric property of Langmuir-films. MDC flowing across monolayers is analyzed using a rod-like molecular model. A method for determining the dielectric relaxation time ${\tau}$ of floating 'monolayers on the water surface is presented. MDC floing across monolayers is analyzed using a rod-like molecular model. It is revealed that the dielectric relaxation time ${\tau}$ of monolayers in the isotropic polar orientational phase is determined using a liner relationship between the monolayer compression speed a and the molecular area Am. Compression speed a was about 30,40,50mm/min. LB layers of Arachidic acid deposited by LB method were deposited onto slide glass as Y-type film.The physicochemical properties of the LB films were examined by UV absorption spectrum, SEM and AFM. The structure of manufactured device is Au/Arachidic acid/Al, the number of accumulated layers are 3~9. Also, we then examined of the MIM device by means of I-V characteristic of the device is measured from -3 to +3[V]. The insulation property of a thin film is better as the distance between electrodes is larger.

  • PDF

전차선의 집전상태 판단 알고리즘 구현 (On the Implementation of an Advanced Judgement Algorithm for Contact Loss of Catenary System)

  • 박영;정호성;윤일권;김원하
    • 전기학회논문지
    • /
    • 제63권6호
    • /
    • pp.850-854
    • /
    • 2014
  • Analyzing dynamic performance between pantograph and contact wire depends on mechanical and electrical conditions such as contact force, currents, aerodynamics of pantograph and tension of overhead contact wire. For the characteristic of dynamic performance between pantograph and overhead contact wire, various evaluation systems are used to measuring of the interaction of the contact line and the pantograph. Among the various methods, the contact force and percentage of arcing are intended to prove the safety and the quality of the current collection system on the train. However, these methods are only capable of measuring on the train which are installed measurement systems. Therefore in this paper, a track-side monitoring system was implemented to measure electrical characteristics from active overhead contact wire systems in order to constantly estimate current collection performance of railway operation. In addition, a method to analyze loss of contact phenomena was proposed. According to simulation results, the proposed system was capable of measuring abnormal electrical behavior of pantograph and contact wires on the track-side. The advantage of the proposed system is possible to detect loss of contact or any other electrical abnormalities of all types of trains within sections from sub to sub without the need to install any on-board equipment on trains.

Analytical Modeling of Conventional and Miniaturization Three-Section Branch-Line Couplers

  • You, Kok Yeow;AL-AREQI, Nadera;Chong, Jaw Chung;Lee, Kim Yee;Cheng, Ee Meng;Lee, Yeng Seng
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.858-867
    • /
    • 2018
  • Analytical modeling equations are proposed for the conventional and modified three-section branch-line couplers. The analytical equations are explicit and capable of determining the characteristic impedance of each branch line for the coupler at desired coupling level as well as the suitability of broadband S-parameters analysis. In addition, a bandwidth extension and miniaturization of three-section branch-line coupler using slow-wave and meandering line structures were designed. The modified coupler, which is able to operate within frequencies from 1.5 to 3.32 GHz has been fabricated, tested and compared. A bandwidth extension of 600 MHz and 53% reduced size of the modified coupler have been achieved compared to a conventional coupler. The modified coupler has roughly insertion loss and coupling of -4 dB and -3.2 dB, while the isolation and return loss, respectively less than -14 dB with fractional bandwidth of 77 %, as well as phase imbalances less than $2^{\circ}$ over the operating bandwidth. Overall, the derived analytical model, simulation and measurement results demonstrated a good agreement.

모노펄스 정확도를 위한 능동배열위상레이다의 근접전계 수신시험 표본 주파수 채널 선택에 대한 연구 (A Study on Sample Frequency Channel Selection of Near-Field Receiving Measurement for the Active Phased Array Antenna for Mono-Pulse Accuracy)

  • 권용욱;윤재복;유우성;장헌순;김도열
    • 한국전자파학회논문지
    • /
    • 제28권4호
    • /
    • pp.318-327
    • /
    • 2017
  • 능동위상배열안테나는 정밀한 빔의 형성과 성능 확인을 위해 근접전계 수신시험이 요구된다. 그에 따른 근접전계 수신시험을 통해 모노펄스 기능을 활용하기 위한 보상값을 획득하게 된다. 하지만, 많은 주파수 채널을 사용하는 레이다의 경우 많은 시간과 노력이 요구된다. 효율적인 레이다 개발과 생산을 위해서는 선택적으로 주파수 채널을 선정하고, 그 측정값을 기준으로 측정하지 않은 주파수 채널의 보상값을 보간법을 통해 예측하여 획득할 수 있다. 이와 같은 방법으로 보상값의 위상각 정보를 획득할 경우, 합, 차 채널간의 위상변화량을 확인할 필요성이 있다. 위상의 측정은 랩핑으로 인하여 비선형 현상이 나타날 수 있기 때문이다. 일반적인 레이다의 경우, 합, 차 채널의 전기적 길이가 유사하게 설계되지만, 특정 목적으로 전기적 길이 차이가 발생할 경우, 랩핑 현상으로 인해 보간법의 오류를 발생할 수 있다. 본 논문에서는 전기적 길이 차이에 의해 발생되는 보간법의 오류를 확인하고, 하나의 주파수 선택 방안을 제시한다.

무선 센서용 표면탄성파의 3 차원 모델링 (3D modeling of a surface acoustic wave for wireless sensors)

  • 트렌 녹 쿵;정귀상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.111-111
    • /
    • 2009
  • In this work, we discuss simulation of surface acoustic wave device using Comsol Multiphysics. The structure SAW device based on piezoelectric thin film aluminum-nitride (AlN) on silicon was simulated. Some parameters of SAW device such as surface velocity, displacement of piezoelectric thin film were evaluated by software. Many modes and shapes of wave are also discussed in this paper. For evaluation physical parameters of AlN piezoelectric layer, the SAW resonator was modeled and simulation results were also compared with experiment results. we simulated arid evaluated the surface Rayleigh wave of AlN thin film on silicon substrate. Results simulation and experiment showed the surface velocity of AlN thin film was about 5200 m/s and shape of surface wave was also displayed. This paper has also proposed as method to study SAW characteristic of piezoelectric thin film and found out measurement values accurately of film such as stiffness matrix, piezoelectric matrix. These values are very important in calculation and design SAW device or MEMS device based on AlN piezoelectric layer.

  • PDF

Poly-${\gamma}$ Benzyl $_D$-Glutamate 유기박막의 전자이동특성에 관한 연구 (A Study on the Electronic Properties of Poly-$\gamma$ Benzyl $_D$-Glutamate Organic Thin Films)

  • 송진원;이경섭;이봉주;구할본
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 센서 박막재료 반도체재료 기술교육
    • /
    • pp.86-89
    • /
    • 2002
  • We give pressure stimulation into organic thin films and then manufacture a device under the accumulation condition that the state surface pressure is 10[mN/m]. In processing of a device manufacture, we can see the process is good from the change of a surface pressure for organic thin films and transfer ratio of area per molecule. The structure of manufactured device is Au/Poly-${\gamma}$ Benzyl $_D$-Glutamate/Al and Au/Poly-${\gamma}$ Benzyl $_D$-Glutamate/Au; the number of accumulated layers is 1, 3, 5 and 7. Also, we then examined of the MIM device by means of I-V. The I-V characteristic of the device is measured from 0 to +2[V]. We determined electrochemical measurement by using cyclic voltammetry with a three-electrode system. LB film accumulated by monolayer on an ITO. In the cyclicvoltammetry, An Ag/AgCl reference electrode, a platinum wire counter electrode and LB film-coated ITO working electrode measured in $LiBF_4$ solution, stable up to 0.9V vs. Ag/AgCl.

  • PDF