• Title/Summary/Keyword: Electrical Accident

Search Result 516, Processing Time 0.027 seconds

태양광발전설비 안전관리 현황 분석 (Analysis of the Status of Safety Management of Photovoltaic Power Generation Facilities)

  • 김완수;박상준;안성렬
    • Current Photovoltaic Research
    • /
    • 제7권2호
    • /
    • pp.38-45
    • /
    • 2019
  • In this paper, we analyzed the present status of the safety manager and safety assurance aspects through a complex analysis on the operational aspects, marketability and electrical safety aspects of photovoltaic power generation facilities. In the analysis of the equipment status, we analyzed the status and operated status of the installed PV system in Korea and the correlation between the safety manager and the accident. In addition, we analyzed the direction of the ESS through the analysis of the installation status of the ESS, and applied it to the interpretation part of the ESS associated with the solar power generation. The status of the electric safety manager can be used to analyze the data for selecting the electric safety manager by capacity by analyzing the accident status, the electric safety manager operation status, the safety management time by capacity, and the electric safety manager market.

차단기의 차단합성성대기적에 관한 연구 (A Study on the Adapting for Interrupting Capacity Augmentation of Circuit Breaker)

  • 황석영;조무제
    • 대한전기학회논문지
    • /
    • 제33권8호
    • /
    • pp.299-309
    • /
    • 1984
  • This paper proposes the adapter for interrupting capacity augmentation of circuit breaker which can be applied in case of shortage in a existing circuit breaker's interrupting capacity due to utility system extension. The adapter utilizes two winding type of reactor instead of single winding type of reactor and the control of 2ry circuit is excuted by a triac interlocked with the system protective relays actuation so as to cut out the reactor by short circuit of the 2ry winding in normal situation and to cut in the reactor by open circuit of the 2ry winding in abnomal situation such as short circuit accident. As a result of the theoritical analysis and experiment, it is proved that the adaptor can reduce the voltage crop and iron loss due to the reactor signigicantly in normal system condition and do a role of reactor upon the power system accident.

전압제어 회로에 의한 호이스트용 통합 드라이브 장치 (The Integration Drive Equipment for Hoistby using Voltage Control Circuit)

  • 라병훈;송대현;서기영;고희석;이현우
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.281-286
    • /
    • 2002
  • An existent hoist drive system is using each different drive equipment in control of Hoisting, traveling(T/L), traversing(T/S) driving, so there are much energy losses because of excessive weight. Also, power circuits are using relay contact, so working environment are frequent secession accident etc.. by shock on unfavorable condition, and there is danger of safety accident, maintenance has frequent problem and so on. To solve these problem, it is integrated each driving power supply in drive system for hoist control and drive, utility power supply etc.. by single device in this research. The power circuit is consisted of non-contact circuit applying to bidirectional voltage controller circuit using thyristor that is power semiconductor switching device

  • PDF

UHV변압기에서 유동대전에 의한 사고 방지에 관한 연구 (A Study on the Preventive Method of Accident by Streaming Electrification in UHV Transformer)

  • 박재윤;고희석
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제6권5호
    • /
    • pp.38-44
    • /
    • 1992
  • In this paper, electrification pipe modeled on the oil path that insulating oil flow in the high power transformer is manufactured in order to prevent the accident cause from streaming electrification generated when insulating off flow at a solid-liquid interface, and the streaming current is measured and analyzed according to the shape of oil path in electrification pipe. From the result of this study, the streaming current increases linearly with increasing of a oil velocity and it increases at lower temperature and decreases at higher temperature than [$46^{\circ}C$]. The smoother the flow of insulating oil is the more the streaming current decreases.

  • PDF

열화 진단 평가를 위한 직류 누설법의 활용 (APPLICATION OF DIRECT LEAKAGE CURRENT METHOD FOR AGING DIAGNOSIS EVALUATION)

  • 이관우;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.149-152
    • /
    • 2001
  • In this paper, aging diagnosis method of CV cable was investigated. CV cable was designed for the sake of using during 30 years. Therefore it was important to evaluate the cable's remaining life because CV cable used for power transmission line since 1970's. CV cable was mainly installed at the underground owing to the environmental condition. If the cable accident occurred, it needs the much time for the accident recovery and the much damage at the industrial activity. therefore, this paper should study the direct leakage current method, a sort of the cables' aging test method

  • PDF

전자연동장치의 안전성 활동에 관한 연구(I) (A Study On Hazards Identification Of Programmable Electronic Interlocking System For Safety Activity)

  • 박재영;이종우
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권12호
    • /
    • pp.661-666
    • /
    • 2006
  • Interlocking signalling system plays key role as core system to manage railway operation. The core role of railway operation is to control routing, displaying signal and regulation for train. Interlocking system relate tightly to railway accident because collision and derailment is sometime taken place wrong route setting and signal displaying. Safety activity for interlocking system is inevitable to avoid the accident over its life cycle. The safety activity includes hazard identification and analysis, safety requirement allocation, safety plan, safety activity and ao on. The safety activity need a broad wide range work. In this paper, we concentrate on hazard identification for generic interlocking system and programmable electronic interlocking system and compare between two results. The hazards will be used for safety activity.

Demagnetization Diagnosis of Permanent Magnet Synchronous Motor Using Frequency Analysis at Standstill Condition

  • Yoo, Jin-Hyung;Jung, Tae-Uk
    • Journal of Magnetics
    • /
    • 제21권2호
    • /
    • pp.249-254
    • /
    • 2016
  • Recently, electric vehicles have got significant attention because it is more eco-friendly and efficient than internal combustion engine vehicles. Instead of an internal combustion engine, the electric vehicle has a motor for propulsion. The permanent magnet synchronous motor which has permanent magnet instead of field winding in the rotor has especially higher efficiency and power density than other types of motor. When the irreversible demagnetization is occurred, drivers are exposed to high risk of accident by the fault operation of motor. Therefore, the irreversible demagnetization of permanent magnet should be detected to reduce the risk of accident. In this study, the demagnetization diagnosis method based on the result of locked rotor test is proposed. Based on short measurement time, the proposed diagnosis method aims to detect the demagnetization fault when an electric vehicle is at a complete standstill. The proposed method is verified through the finite element analysis.

열화 진단 평가를 위한 직류 누설법의 활용 (APPLICATION OF DIRECT LEAKAGE CURRENT METHOD FOR AGING DIAGNOSIS EVALUAT10N)

  • 이관우;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.149-152
    • /
    • 2001
  • In this paper, aging diagnosis method of CV cable was investigated. CV cable was designed for the sake of using during 30 years. Therefore it was important to evaluate the cable's remaining life because CV cable used for power transmission line since 1970's. CV cable was mainly installed at the underground owing to the environmental condition. If the cable accident occurred, it needs the much time for the accident recovery and the much damage at the industrial activity. therefore, this paper should study the direct leakage current method, a sort of the cables'aging test method.

  • PDF

고압유도전동기용 기동리액터의 절연진단 (Insulation Analysis of Starting Reactor for High Voltage Induction Motors)

  • 이은춘;김태호;변일환;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 전기설비
    • /
    • pp.61-62
    • /
    • 2006
  • Since the starting reactor used for reducing inrush current of high voltage induction motor applies an electric current only when it is at the stage of transition, it gets lots of electrical or mechanical stress. In this aspect, the reliability on the starting reactor is very important because the reactor-relating-accident takes 80% of all the accident concerned with high voltage motor starting panel. In this study, we conducted an insulation test of starting reactor of high voltage induction motor of intake pumping station to the Seoul area And the result from this study was used as data for determining whether it's still usable or not.

  • PDF

고조파에 의한 저압용 차단기의 동작특성 해석 (Analysis of Active Characteristic the Low-voltage Circuit Breaker for Harmonics)

  • 최문규;정병환;박종찬;김한구;목형수;최규하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1474-1476
    • /
    • 2005
  • Because MCCB, ELB, etc. discharge both technical and economical duty, it is important that the study of circuit breaker guarantee high-performance and realize the power distribution system with reliability. Because of complexity electrical equipment, the accident with imbalance and flicker occur often according to technical improvement. However, study of accident with harmonics remains. In this paper, the essential characteristic of circuit breaker is introduced. To analysis operation of circuit breaker, theoretical model and several simulations have been performed.

  • PDF