• Title/Summary/Keyword: Electrical Accident

Search Result 519, Processing Time 0.031 seconds

Soil Breakdown Test using Fixture (Fixture를 이용한 토양 절연파괴 실험)

  • Lee, H.G.;Ha, T.H.;Jung, D.H.;Ha, Y.C.;Kim, D.K.;Bae, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.384-385
    • /
    • 2007
  • The fault current through the earth originated from a power line ground fault might cause arcing through the soil to an adjacent pipeline, which might bring about not only a catastrophic accident such as gas explosion and oil leakage but also a hazard to the safety of workers responsible for the maintenance and repair of the pipeline. In this paper we experimented on the soil breakdown test using the fixture and outlined the standards for the separation distance of a buried pipeline adjacent to the power line tower.

  • PDF

Optimal Condition Gain Estimation of PID Controller using Neural Networks (신경망을 이용한 PID 제어기의 제어 사양 최적의 이득값 추정)

  • Son, Jun-Hyeok;Seo, Bo-Hyeok
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.717-719
    • /
    • 2003
  • Recently Neural Network techniques have widely used in adaptive and learning control schemes for production systems. However, generally it costs a lot of time for learning in the case applied in control system. Furthermore, the physical meaning of neural networks constructed as a result is not obvious. And in practice since it is difficult to the PID gains suitably lots of researches have been reported with respect to turning schemes of PID gains. A Neural Network-based PID control scheme is proposed, which extracts skills of human experts as PID gains. This controller is designed by using three-layered neural networks. The effectiveness of the proposed Neural Network-based PID control scheme is investigated through an application for a production control system. This control method can enable a plant to operate smoothy and obviously as the plant condition varies with any unexpected accident.

  • PDF

The Operational Characteristic of Modified DC Reactor Type HTSC Fault Current Limiter for Accident of Both Power Source Side and Load Side (전원단과 부하단사고에 따른 Modified DC 리액터 타입 고온초전도전류제한기 동작특성)

  • Lim, Sung-Hun;Lee, Jae;Kang, Hyeong-Gon;Choi, Hyo-Sang;Lee, Seong-Ryong;Han, Byoung-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.97-99
    • /
    • 2001
  • 본 논문은 전원단과 부하단사이에 GTO 사이리스터 브리지가 설치된 단상 DC 리액터타입을 적용한 고온초전도 사고전류제한기 동작특성에 대해 분석하였다. GTO 사이리스터 브리지가 설치된 DC 리액터 타입 FCL(FAULT CURRENT LIMITER)은 평상시에 초전도코일에 전기에너지를 저장한다. 전원단의 사고로 인해 전력공급이 중단되었을 경우 FCL은 부하에 저장된 에너지를 공급할 수 있을 뿐 아니라 부하단 사고로 인한 사고전류 제한기능을 수행하게 되는데 이와 같은 동작은 GTO 사이리스터를 제어함으로서 가능해진다.

  • PDF

Development of Single-piece Composite Bushing for High Voltage Switch (고압개폐기용 일체형 복합붓싱 개발)

  • Choi, K.S.;Joo, J.M.;Lee, Y.S.;Yu, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1059-1061
    • /
    • 2005
  • The bushing currently applied to pole-mounted type loadbreak switch has porcelain bushing which is connected with the mold cone. This type has potential problems of uncertainty of sealing of the interface part and gas leakage on the connected part between bushing and switch tank due to the weight of the porcelain. The Composite Bushing can solve these problems and also the secondary problem of the potential accident owing to the fragment of the porcelain bushing in breakage due to the outer impact.

  • PDF

Convergence Progress about Applied Gain of PID Controller using Neural Networks (신경망을 이용한 PID 제어기 이득값 적용에 대한 수렴 속도 향상)

  • Son, Jun-Hyug;Seo, Bo-Hyeok
    • Proceedings of the KIEE Conference
    • /
    • 2004.05a
    • /
    • pp.89-91
    • /
    • 2004
  • Recently Neural Network techniques have widely used in adaptive and learning control schemes for production systems. However, generally it costs a lot of time for learning in the case applied in control system. Furthermore, the physical meaning of neural networks constructed as a result is not obvious. And in practice since it is difficult to the PID gains suitably lots of researches have been reported with respect to turning schemes of PID gains. A Neural Network-based PID control scheme is proposed, which extracts skills of human experts as PID gains. This controller is designed by using three-layered neural networks. The effectiveness of the proposed Neural Network-based PID control scheme is investigated through an application for a production control system. This control method can enable a plant to operate smoothy and obviously as the plant condition varies with any unexpected accident. This paper goal is convergence speed progress about applied gain of PID controller using the neural networks.

  • PDF

Safety Countermeasure of the distribution box of service wire (인입선 분기함의 안전대책에 관한 연구)

  • Ha, Tae-Hyun;Bae, Jeong-Hyo;Lee, Hyun-Goo;Kim, Dae-Kyeong;Ha, Yoon-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.246-248
    • /
    • 2004
  • The lower voltage distribution box of service wire has been usually employed to supply an electric power to the consumers through low voltage overhead line. Now-a-days, electric shock accident at the distribution box of service wire installed in the seashore areas has been often occurred. The reason is mainly due to the electric leakage in the distribution box of service wire. This paper described insulation breakdown mechanism of distribution box of service wire, analysis of electric shock path and safety countermeasure of distribution box of service wire.

  • PDF

Deterioration Test of IGBT Devices in Motor Driver (전동기 구동용 IGBT 소자의 열화 진단)

  • Ahn, Jong-Kon;Park, Soon-Myung;Kim, Tae-Gi;Kang, Ju-Hee
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.400-405
    • /
    • 2008
  • Motor is energy converting system to generate mechanical force from electrical power and there are various typed motors in home, office, factory, vehicles, aircraft, shipping, etc. Recently in compliance with performance and reliability and the applications of variable speed motors with invert driver are expanded. Almost high power inverter have IGBT and IGBT's fault cause motor system fault. If we can calculate and foresee troubles of IGBT, we can protect accident caused by motor system fault. In this paper, the deterioration test method of IGBT devices is proposed and the test results of proposed method are shown by evaluated equipment. The basic concept of proposed method is current-voltage characteristic curve test between drain and source of IGBT in open state. The applied voltage type is ramp and it is confirmed that the current-voltage curvet pattern of IGBT in open state represents IGBT's deterioration state.

  • PDF

Comparison of the Effects of Massage, Stretching Exercise and Scapular Stabilization Exercise in Patients with Upper Trapezius Myofascial Pain Syndrome (상승모근 근막동통증후군 환자에 대한 마사지, 신장운동, 견갑골 안정화운동의 효과 비교)

  • Park, Young-Soek;Kim, Suhn-Yeop;Oh, Duck-Won;Choi, Duk-Jong;Bae, Ho-Won;Seo, Young-Joo
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.17 no.1
    • /
    • pp.1-8
    • /
    • 2011
  • Background: The purpose of this study was to determine the effects of massage, stretching exercise, and scapular stabilization exercise in patients with upper trapezius myofascial pain syndrome (MPS). Methods: Twenty-three female patients with upper trapezius MPS were randomly allocated to three groups: massage, stretching exercise, and scapular stability exercise groups. Therapeutic intervention for all groups included general therapy such as hot pack, transcutaneous electrical nerve stimulation and ultrasound. Patients in the massage group (n=8), stretching group (n=7), and stabilization exercise group (n=8) received their respective therapy program after general therapy for 15 minutes. Therapeutic intervention for each group was performed three times per week for six weeks. All groups were tested four times: prior to the test, at three weeks, at six weeks, and at nine weeks. Results: Pain levels decreased significantly in the stretching and stabilization exercise groups over time (p<.05). The rate of change in pain level was significantly different among all groups (p<.01), and the stability exercise group experienced the lowest pain level. Pressure-pain level increased significantly in the stabilization exercise group over time (p<.05). The rate of change in pressure-pain level was significantly different among all groups (p<.01), and the stability exercise group had the highest pressure-pain level. The level of upper-extremity stability increased significantly in the stability exercise group over time (p<.05). The rate of change in the upper-extremity stabilization level was significantly different among all groups (p<.01), and the stability exercise group had the highest upper-extremity stability level. Conclusions: Scapular stabilization exercises proved to be the most effective therapy for MPS patients.

  • PDF

A Study on the Safe Gap for Explosion-proof (내압방폭을 위한 Safe Gap의 측정에 관한 연구)

  • Oh Kyu-hyung
    • Journal of the Korean Institute of Gas
    • /
    • v.1 no.1
    • /
    • pp.1-6
    • /
    • 1997
  • In case of using the electrical apparatus in the hazardous atmosphere which exist flammable gas mixtures, There is a dangerosity of gas explosion accident by the electrical spark. The most general method to prevent the explosion by the spark is to use the flame-proof type electrical apparatus to isolate the ignition source. from the flammable atmosphere. But actualy it is impossible to isolate the ignition sources from the atmosphere. So it was needed to find the safe gap which prevent ignition of flammable atmosphere by transmission of flame or heat when a flammable gas mixture exploded inside the apparatus. In this study we tried to find the maximum experimental safe gap(MESG) of $H_2$-air, and $CH_4$-air mixtures by using the 8 litre spherical vessel with 25mm flange. The experiment parameter were ignition position, concentration and initial pressure before explosion. From the experiment the ignition position was affected to the MESG. MESG value was minimum near the stoichiometric concentration of gas mixtures, and according to the increase of initial pressure MESG was decreased.

  • PDF

Finding and Analysis of Defective Elements of an LED Streetlight Lamp Based on the Product Liability (PL에 근거한 LED 가로등의 결함 요소 발굴 및 분석)

  • Kim, Hyang-Kon;Choi, Chung-Seog
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.632-632
    • /
    • 2009
  • The purpose of this study is to present the range of defects mentioned in the Product Liability (PL) and to establish an objective basis and grounds for the analysis of accidents expected to happen by analyzing and presenting the external flame pattern and electrical characteristics of an LED streetlight lamp, a new lighting lamp. From the analysis of the cross-section of a cable carbonized by an external flame, it was observed that the wire's strand and insulation material had solidly adhered, and that greater voids were formed at the surface than at the center. Irregular carbide lumps were formed in the globe directly exposed to the flame, and the globe carbonized by the indirect flame showed characteristics that they had melted and flowed downward. It was found that the forward and backward resistances of the normal LED were approximately 1.74 [$M{\Omega}$] and 140 [$M{\Omega}$], respectively. The lamp burnt by the strong flame exhibited infinite forward and backward resistances and the LED did not emit light. The carbonized LED lamp was gray and exhibited fine delaminations. According to the Product Liability, a product defect signifies a simple product defect. Most of the defects were caused by the lack of stability, and the defect of the product itself occurred during the design and manufacture. The defects in warnings and markings include an insufficiency of handling manuals and warnings, expressive warranty violations, defective markings, etc. In order to prevent an accident resulting from a product, it is necessary to prepare safety warnings and documentation, establish clear-cut lines of liabilities, and subscribe insurances. However, it could be seen that important factors against the Product Liability were product improvement, response to compensation requests and law suits, credit restoration, etc.