• Title/Summary/Keyword: Electrical Accident

Search Result 519, Processing Time 0.03 seconds

Automatic Measuring Apparatus for Salt and Dust Contamination (염진해 오손도 자동측정장치)

  • 최남호;구경완;이명섭;한상옥;정재기;조성배
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.187-190
    • /
    • 1999
  • To reduce the maintenance expence, and the possibility of electric outage and accident, accurate measurement should be carried. But the classical method has some problems in the aspect of man power, reliability, and expence. In this paper, we propose a new type apparatus, which could detect the degree of contamination on insulators on outdoor insulation system, such as transmission and distribution line insulator and bushing. The new type apparatus consists of Pelltier module, electrode system, and measuring part. At first leakage current detecting method was considered, then with the fault(oxidation of electrode) of that method we should propose a another method. We carried various test to prove the possiblity and reliability of the propoused apparatus. And we get some useful result with laboratory test.

  • PDF

A Study on the Marine Lattern Development using Light Emitting Diodes (해상용 LED(Light Emitting Diode) 등명기 연구개발)

  • Jeong, Hak-Geun;Jung, Bong-Man;Han, Su-Bin;Yu, Seong-Won;Kim, Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.167-170
    • /
    • 2004
  • A high light lantern system using LEDs is composed of power supply, flash controller, and daylight controller and proper case considering work condition. The performance of developed LED lantern is better than that of the existing marine lantern using an incandescent electric lamp and that of foreign products(Vega LED lantern made in New Zealand, Tideland system made in America). The electric consumption of our products is 30% compared with that of existing marine lantern using an incandescent electric lamp, and the luminous Intensity of them is 200% to 400% compared with that of existing marine lantern and foreign LED lantern. In addition, our LED lantern system is easy to repairing something wrong and changing the LED module and other controllers on the sea when they are in accident.

  • PDF

Electric power system effect investigation of large size digital signal accident thought in digital age (디지털시대의 대형사고의 전기적 영향 고찰)

  • Kang, Tae-Keun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.575-580
    • /
    • 2004
  • The latest equipment automatic Intelligence of digital base done large size equipment appear in succession. That run by voltage electric current(mA, mV, ${\mu}A,\;{\mu}V$) that outline is microscopic of action of accuracy large size equipment of this digital base is bulk. Have received influence that is great in river electric field by installment that use computer. Most of domestic working voltage from service entrance extra-high voltage and working voltage of commercial frequency 60Hz working voltage 220V that use our country outside 1 country in interior of 22.900V for semiconductor use computer use digital installment of appliance as well as various smalls of digital base, middle, large size that safety is these fine voltage electric current that is not enough direct admonition hundred vast damage give can. Also, already act in surge circle and impulse transient phenomena such as several thousands, myriads, strong bit error more than billions time to digital fine electronic circuit by mistake use of using electric facility system of system electric power.

  • PDF

A Study on the Diagnostic Technique for Distribution Transformers using Multi-Channel Wireless Communication Network (다채널 무선 통신망을 이용한 배전용 변압기 진단 기법에 관한 연구)

  • Kim, Jae-Chul;Choi, Joon-Ho;Kim, Dong-Hyun;Moon, Jong-Pil;Kim, Oun-Seok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.3
    • /
    • pp.131-139
    • /
    • 2001
  • As increasing the accident of Distribution Transformer (DT), we need to manage them efficiently. In this paper, we discusses with the possibility of the diagnostic technique for distribution transformer using relative ageing rate calculation in this paper. The relative ageing rate of the DT could be calculated from the measured top oil temperature, ambient temperature and load current. In order on apply the proposed diagnostic technique we developed an on line Monitoring and Diagnostic System (MDS) which has hardware and software part. Diagnostic device is developed to measure the state information of DT and to send them with R/F(radio frequency) communication. Host computer monitors and saves the receive data. The database is constructed from the data of distributed DT and it is used for estimating loss-of-life in the MDS.

  • PDF

Investigation on propagation characteristics of AE signal with FEM (FEM을 이용한 음향신호의 전달특성에 관한 연구)

  • 서판석;구경완;김종석;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.274-277
    • /
    • 2001
  • This paper describes the simulation study, conducted on the propagation characteristics of AE signal. In the case of gas insulation, such as SF6, the equipment is less affected by the environment condition than air insulation, because the component parts of equipment were placed in the enclosure, which is filled with compressed gas. But, when the breakdown in the electric insulation occurs, it takes much time and economical efforts to repair. Therefore it is very important to diagnose the equipment before the accident. And, in general, UHF and AE signal is the most common transducer to diagnose the state of the power equipment, so, in this investigation, we make a experimental apparatus with aluminum plate and transient analysis with ANSYS to observe the propagation characteristics of AE signal. Through the result of the analysis, we can make a further understanding on the propagation characteristics of AE signal, and get the fundamental skills for the GIS diagnosis.

  • PDF

Design and Development of Harmonic Power Source Control Module (고조파 전원발생장치의 제어기 설계 및 개발)

  • Lee, S.I.;Yoo, J.G.;Jeon, J.C.;Jeon, H.J.;Heo, H.S.;Choe, G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.40-42
    • /
    • 2007
  • Recently the harmonic generation has deteriorated the quality of electricity and affected the performance on the electrical installation including personal computer, fax, community devices and so on. Some studies of harmonic affects in diagnosis and the cause of accident has not done by the experimental data of harmonic source but merely by presumption according to qualitative analysis. So, in order to research the harmonic affect on the electrical installation according to quantitative analysis and gather reliable data over and over again, it is necessary to develop an Harmonic power source which is capable of generating some harmonics. In this paper, we described about realization of Harmonic power source control module which can produce and added harmonics for the analysis due to harmonic effects.

  • PDF

A Study on unperfected circuiting current of undergrounded cable (지중송전케이블의 불완전 순환전류에 관한 연구)

  • Lee, Kwan-Woo;Lee, Yong-Sung;Kim, Bo-Kyeng;Park, Bok-Ki;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.3-6
    • /
    • 2004
  • In this paper, we studied on permissible current of unperfected earthing for cross-bond system. The factors of unperfected earth were jacket damage, cross-bonding mistake, arrestor damage, effect of other circuit but we only studied permissible current of arrestor or jacket damage. In the result, we earned that permissible current of normal 154[[kV]] CV $1C{\times}400SQMM$ cable is 760[A] but current of unperfected earthing cable is 76[A], unperfected earthing confirmed that accident of underground cable could occur. So, we could confirmed that Earthing resistance of unperfected earthing need to limit.

  • PDF

Analysis of the Inner Degradation Pattern by Clustering Algorism at Distribution Line (군집화 알고리즘을 이용한 배전선로 내부 열화 패턴 분석)

  • Choi, Woon-Shik;Kim, Jin-Sa
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.1
    • /
    • pp.58-61
    • /
    • 2016
  • Degradation in power cables used in distribution lines to the material of the wire, manufacturing method, but also the line of the environment, generates a variety of degradation depending upon the type of load. The local wire deterioration weighted wire breakage accident can occur frequently, causing significant proprietary damage can lead to accidents and precious. In this study, the signal detected by the eddy current aim to develop algorithms capable of determining the signals for the top part and at least part of the signal by using a signal processing technique called K-means algorithm.

A Study on the Technical Regulation of Brake System for Electrical Multiple Unit Safety (전동차 안전을 위한 제동장치의 기술기준에 관한 연구)

  • Lee, Woo-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1332-1334
    • /
    • 2003
  • Safety of breaking facility is very important in subway safety, especially in case of subway that many people used, breaking capability is connected directly with safety and capability of vehicle. Recently, direction of subway technical development is established as passenger's convenience and agreeableness. However, we are known importance of safety in subway through Dae-gu subway incendiary case. Subway accident not happen only fire, vehicle collisions or passenger's fall to the track can happen. In this case, safety standard of breaking facilities is very important. so this paper define safety of breaking facilities and take proper that standard.

  • PDF

The study Alarm & Auto Locking System of Electric Wire Compressor (경보음 발생 및 자동Locking 장치형 전선압축기에 대한 연구)

  • Choi Myeongho;Lee Sangho;Kim Dongmyung
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.800-802
    • /
    • 2004
  • When an accident is happen due to using a bad Wire Compressor, some public resentments are caused and It cause lawsuit for we. In case, we will undergo a colossal financial loss. in addition to, Guide to improve quality of operation by using the number of times of pressing and pressing pressure with cooperative private enterprise. And because of needs for Thermal, Electrical and Chemical factor analysis of connection point of sleeve, expect to try improving problems of wire presser whole our company. We expect that reduce fault and save cost by this process. Consequently, we will prevent power losing and black out due to line faults by expulsion of inferiority equipment and prevent heating and line fault. This is possible using Alarming and Auto Locking Wire Compressor that is improve on this study.

  • PDF