• Title/Summary/Keyword: Electric transformer

Search Result 697, Processing Time 0.042 seconds

Field Demonstration of the Distribution STATCON-Engineering (배전용 STATCON 설치사례-엔지니어링)

  • Han, Y.S.;Yoo, I.D.;Choi, J.Y.;Hong, S.W.;Lee, H.S.;Jeon, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2575-2577
    • /
    • 1999
  • This paper describes the engineering process for analyzing the simulation result and deciding the site in which Distribution STATCON operates more effectively. For this purpose the modeling method of industrial loads, equipments and STATCON was represented. Models of motor, furnace and so on are presented for the modeling of industrial loads. The distribution system models include the parameters of the distribution line and transformer. The models of PESS(Power Electronics Subsystem), controllers and maginetics are consist of STATCON model.

  • PDF

Fabrication of long length Bi-2223/Ag HTS tape (Bi-2223/Ag 고온초전도 장선재의 제조)

  • Kim, Sang-Cheol;Lee, Dong-Hoon;Ha, Dong-Woo;Oh, Sang-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.69-72
    • /
    • 2004
  • In order to use HTS tape on electric power applications, such as cable, motor, transformer, fault current limiter, a long length of HTS tape with a good uniformity of critical current is inevitable. The longer length of HTS tape, the wider in the range of application and the lower cost of HTS tape. In this study three long length Bi-2223/Ag tapes(268m, 253m and 187m) were fabricated. Critical current uniformity along the length was greatly improved through the optimization of cold deformation and thermo-mechanical process. Average critical current of the tapes was 63.2 A, 54.6 A and 64.2 A, respectively Critical tensile strength and critical bending radius (77 K, 5 % Ic degradation) was 135 MPa and 56 m, respectively.

  • PDF

A Study on Synthetic Failure-finding Method for Electrical and Thermal Degradation of Polymer Insulator by Surface Discharge

  • Lee, Kang-Won;Jang, Dong-Uk;Park, Cheol-Hyun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.3
    • /
    • pp.143-146
    • /
    • 2007
  • Polymer insulators are used widely in variable fields for high voltage insulation and separating people from high voltage charging parts for safety and also supporting overhead power line in electric railway. But it may be broken down by tracking path resulting from continuous surface discharge. This paper has investigated synthetically both the characteristics of electrical aging using precision CT(current transformer) and the thermal aging using thermography method. Electrical aging was analyzed for time-frequency region and thermal aging was illustrated by image processing method. This synthetic method may be an appropriate one to evaluate the surface degradation of polymer insulator.

Development of the Hybrid Fault Current Limiter (복합형 한류기 개발)

  • Park, K.B.;Lee, G.H.;Bang, S.H.;Choi, W.J.;Sim, J.W.;Sin, Y.S.;Kim, Y.G.;Hyun, O.B.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.125-125
    • /
    • 2010
  • The Hybrid Fault current limit combined the semiconductor switching components, for example IGBT, with mechanical fast switch reduced mechanical and thermal stress on electrical machines, for example circuit breaker, transformer, and so on, in the electric network. We had focused on reducing the voltage stress of the semiconductor switching components by the mechanical fast switch. As a result, we could dramatically reduce amount of semiconductor switching components only using parallel arrangement of them, not series.

  • PDF

Implementation and Performance Evaluation of Opto-Electronic OverCurrent Relay (광전자식 과전류 보호계전기의 구현 및 성능 평가)

  • Park, Byung-Seok;Ahn, Sung-Joon;Jang, Moon-Jong;Woo, Hee-Gon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.3
    • /
    • pp.284-290
    • /
    • 2000
  • The measurement of electric current using optical techniques provides a number of important practical advantages including effective isolation from high line potentials and freedom from the saturation effects observed in conventional current transformers. In this work the optical current sensor which uses thin YIG(Yittrium Ion Garnet) film as a Faraday element has been developed. We have characterized this optical current sensor and implemented it to the OOCR(Opto-electronic OverCurrent Realy) Performance of the OOCR shows the possibility of replacing the present overcurrent relays with OOCR.

  • PDF

Properties of Epoxy Based Nanocomposites and their Application to High Efficiency Electric Materials (나노복합체를 이용한 고효율 전기소재 설계 기술)

  • Lee, Sang-Heon;Koo, Kyung-Wan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.1
    • /
    • pp.45-47
    • /
    • 2011
  • Recently, research works for electrical properties on the elastic epoxy have been also progressing to diagnose insulation materials by development of measure technology. The epoxy which specially applied for high voltage instruments have required for the electrical, mechanical and thermal properties. Nanocomposites were made from insulating material epoxy resin using for power transformer as varying g amount of addition of SiO2, we found the change of physical characteristics of nanocomposites by using SEM and XRD. To investigate the electrical properties according to the amount of addition and temperature, tested insulting breakdown in silicon oil. As the result of insulting breakdown testing, the insulting breakdown strength increased according to change of the amount of addition.

Analysis of Output Pulse of High Voltage and Nanosecond Blumlein Pulse Generator

  • Roh, Young-Su;Jin, Yun-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.150-155
    • /
    • 2013
  • A high voltage and nanosecond Blumlein pulse generator has been developed to produce an output pulse whose voltage level is greater than 250 kV and pulse duration 5 ns. The generator consists of various components such as a charging circuit, a pulse transformer, and a spark gap switch. As a heart of the generator, a Blumlein pulse forming line has been constructed in the cylindrical form using three cylindrical aluminum electrodes that are placed concentrically. Unlike the ideal Blumlein line, the output pulse of an actual Blumlein line may be affected by stray inductances and capacitances of switching and charging components, thereby degrading the performance of the generator. In this paper, PSPICE simulations have been performed to examine effects of stray inductances and capacitances on waveforms of output pulses. Simulation results show that the pulse waveform is significantly distorted mainly by the stray inductance of the spark gap switch.

A Study on the Mathematical Modeling of Failure Rates Estimation for Asset Management of the Power Transformer (전력용변압기의 자산관리를 위한 고장률 추정기법의 수학적 모델링에 관한 연구)

  • MOU, SHUAILONG;Jang, Kyung-Wook;Baek, Seung-Myung;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.1
    • /
    • pp.33-37
    • /
    • 2017
  • This paper describes the modeling of the failure rate estimation technique for applying the asset management technique to electric power facilities. There are many modeling techniques to estimate the failure rate. In this paper, the characteristics of the normal distribution, exponential distribution, weibull distribution, and piecewise linear functions are discussed. When evaluating reliability, the evaluation may be less meaningful if the sample data is insufficient. Therefore, Weibull distribution and piecewise linear function are adopted as the most suitable functions for estimating the failure rate of power facilities and the resulting failure rate function is derived.

Theory Introduction of Shin-Dong Power for Analysis of Circulating Current on Transformer-Neutral Line in Asymmetric Three Phase Lines (비대칭 3상 선로에서 변압기 중성선의 순환전류 해석을 위한 신동파워이론 소개)

  • Shin, Dong-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1492-1494
    • /
    • 2015
  • 분산전원 연계기준에 따라 변압기 1차 중성점을 접지운전시 Y-Y-3Limb, $Y-{\Delta}$결선방식은 비대칭 계통전압에 의해 순환전류가 발생된다. 이러한 순환전류는 상별 전류에 영향을 주어 보호계전기 오동작 및 전력량계 오차를 발생시킨다. 따라서 순환전류로 인한 전력계산의 문제를 해결하기 위해 신동파워이론을 만들었다. 본 이론의 핵심은 비대칭 3상 전압과 변압기 결선 및 구조에 의해 발생되는 영상 임피던스(R+jX) 해석을 통해 중성선의 순환전류를 계산하였다. 따라서 정확한 전력계산을 위해 순환전류에 의해 발생되는 상별전류를 보정하는 새로운 이론을 소개 하고자 한다.

  • PDF

A study of SCPT excitation system (SCPT(Saturable Current Potential Transformer) 여자시스템에 관한 연구)

  • Ryu Ho-Seon;Shin Mahn-Su;Lee Joo-Hyun;Lim Ick-Hun;Song Seong-il
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.466-469
    • /
    • 2002
  • Many power plants in the thermal and hydraulic utilities, the pulp and the paper industry are faced with high maintenance and down time due to the aged excitation system. For the life extension of the aged power plants, the static excitation system with SCPT type had been developed by KEPRI(Korea Electric Power Research Institute) This paper will discuss the design conception and the application results of system which includes the phase controlled rectifiers of the shunt type, SCPT and redundant analog controller.

  • PDF