MIGSHIELD: A new model-based interactive point kernel gamma ray shielding package for virtual environment

  • Li, Mengkun;Xu, Zhihui;Li, Wei;Yang, Jun;Yang, Ming;Lu, Hongxin;Dai, Xinyu
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1557-1564
    • /
    • 2020
  • In this paper, 3D model-based interactive gamma ray shielding package (MIGSHIELD) is developed in virtual reality platform for windows operating system. In MIGSHIELD, the computational methodology is based on point kernel algorithm (PK), several key parameters of PK are obtained using new technique and new methods. MIGSHIELD has interactive capability with virtual world. The main features made in the MIGSHIELD are (i) handling of physical information from virtual world, (ii) handling of arbitrary shapes radioactive source, (iii) calculating the mean free path of gamma ray, (iv) providing interactive function between PK and virtual world, (v) making better use of PK for virtual simulation, (vi) plug and play. The developed package will be of immense use for calculations involving radiation dose assessment in nuclear safety and contributing to fast radiation simulation for virtual nuclear facilities.

An Experimental Study on Development of EMP Shielding Concrete Using Carbon-Based Materials and Industrial By-Products (카본계 재료 및 산업부산물을 활용한 EMP 차폐 콘크리트 개발에 관한 실험적 연구)

  • Min-Sung Kim;Cheol-Hyun Yoon;Seung-Ho Byun;Tae-Beom Min
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.1
    • /
    • pp.48-54
    • /
    • 2023
  • In this research, The basic physical properties and EMP shielding performance by thickness were evaluated for optimum composition of EMP shield concrete that can be applied on-site by mixing carbon-based materials with high conductivity into concrete that uses electric furnace oxidized slag (EOS). As a result of the evaluation, it was confirmed that the slump decreased as the amount of mixed carbon fib er (CF) increased, and increased when milled carb on (MCF) was mixed. As for the compressive strength, it was confirmed that EOS enhanced the strength compared to NA, and it was confirmed that the strength decreased when CF and MCF were mixed. As the thickness of the EMP shielding measurement increases, the shielding rate increases, and it was confirmed that the type of conductive material and the thickness of the test specimen have a greater influence on the shielding rate than the Amount of conductive material added. As a result of a comparative evaluation, EOS CF 0.2 is considered suitable for EMP shield concrete formulation.

Electromagnetic Wave and EMF Attenuation by Shielding Materials in home appliances (가전제품 전자파 현황 및 차폐재에 의한 감쇄 효과)

  • Cho, Jae-Cheol;Park, Jae-Hwan
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.9 no.6
    • /
    • pp.711-718
    • /
    • 2019
  • Spectrum analyzer and electromagnetic field meter were used to investigate the EM generation behaviour in different types of home electrical appliances. During microwave oven operation, the EM power measured at a point 30cm apart was measured in the range of 8~11mW/㎡, the strength of the low frequency magnetic field was 60~80mG and the electric field strength was measured at 150~160V/m. For smart phone wireless charging pad, it was measured at an electromagnetic power of 0.4mW/㎡, an electric field of 160 V/m and a magnetic field of 1mG at a point 10cm away. For microwave oven and wireless charging pad, if used within 10cm, the size of the electric field has been measured at a large value that exceeds the human body protection standard and may be hazardous to humans. On the other hand, home appliances such as TVs, hairdryers and refrigerators all showed very low levels of electromagnetic waves, electric fields and magnetic fields, with no harmful effects seen. For electromagnetic shielding, the metal Cu fabric and metal foil had a high level of EM shielding, while polymer films had a low EM shielding characteristic.

Study on the Electromagnetic Shielding of Accessory Device without Electromagnetic Shielding Technology in the Magnetic Resonance Room (자기공명검사실 내 전자기파 차단이 이루어지지 않은 부속장치의 차폐에 관한 연구)

  • Son, Soon-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.2
    • /
    • pp.431-436
    • /
    • 2021
  • In this study, a new shielding method was applied to an accessory device that produces electromagnetic waves in the magnetic resonance room to prevent the generation of artifact caused by electromagnetic waves. The research method applied a new shielding made of metal plating fiber to patient surveillance CCTVs without shielding technology, and obtained and evaluated noise map when the power was not cut off and when the new shielding technology was applied without shutting down the CCTV. As a result of the study, it was found that there was at least one group with significant differences. Type I and type III belonged to group 1 while type II belonged to group 2 in the Post-hoc analysis, which meant blocking power of the CCTV and the applying new shielding technology were in the same group. In conclusion, if electromagnetic waves are generated due to additional accessories in the scanning room, the shielding material proposed in this study should be applied which enables the electric state become similar to type I, not generating noise, thereby preventing the artifacts caused by electromagnetic waves.

Analysis of Dose Rates from Steam Generators to be Replaced from Kori Unit 1 (고리 1호기 교체 증기발생기의 선량률 분석)

  • Shin, Sang-Woon;Son, Jung-Kwon;Cho, Chan-Hee;Song, Myung-Jae
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.3
    • /
    • pp.175-184
    • /
    • 1998
  • In order to calculate dose rates from steam generators to be replaced from Kori unit 1 in 1998, radionuclide inventories inside steam generator were evaluated from smear test results and measured dose rates from S/G tubes withdrawn for the metallographical examination of damaged tubes. Based on the inventories, contact dose rates and dose rates at 1 m from the surface of a steam generator were calculated using the QAD-CG computer code. Contact dose rates ranged from 11.5 mR/hr at the bottom of channel head to 37.7 mR/hr at the middle of shell barrel, and showed no significant difference with dose rates at 1 m from the surface of steam generator. Shielding effects of lead and carbon steel were compared to provide basic shielding data. Lead shield showed excellent shielding effects. Dose rate at 1 m from the middle of S/G shell barrel decreased from 38.6 mR/hr to 15.5 mR/hr with the lead shield of 2 mm thickness. However, carbon steel showed a poor shielding effect even with the thickness of 2.0 cm. This can be explained with the great differences in the attenuation effect and buildup factor between lead and carbon steel for low energy photons.

  • PDF

Characteristics of Wireless Power Transmission Using Superconductor Coil to Improve the Efficiency According to the Shielding Materials (초전도 공진 코일의 효율성을 높이기 위한 차폐 재질에 따른 무선전력전송 효율비교 분석)

  • Lee, Yu-Kyeong;Jeong, In-Sung;Hwang, Jun-Won;Choi, Hyo-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.4
    • /
    • pp.684-688
    • /
    • 2016
  • The magnetic resonance method requires high quality factor(Q-factor) of resonators. Superconductor coils were used in this study to increase the Q-factor of wireless power transfer(WPT) systems in the magnetic resonance method. The results showed better transfer efficiency compared to copper coils. However, as superconducting coils should be cooled below critical temperatures, they require cooling containers. In this viewpoint, shielding materials for the cooling containers were applied for the analysis of the WPT characteristics. The shielding materials were applied at both ends of the transmitter and receiver coils. Iron, aluminum, and plastic were used for shielding. The electric field distribution and S-parameters (S11, S21) of superconducting coils were compared and analyzed according to the shield materials. As a result, plastic shielding showed better transfer efficiency, while iron and aluminum had less efficiency. Also, the maximum magnetic field distribution of the coils according to the shielding materials was analyzed. It was found that plastic shielding had 5 times bigger power transfer rate than iron or aluminum. It is suggested that the reliability of superconducting WPT systems can be secured if plastic is used for the cooling containers of superconducting resonance coils.

A Study on Electromagnetic Interference Shielding Effectiveness of the Metal Powders and Nano Carbon black /Fiber Reinforced Epoxy composites (메탈 파우더와 나노 카본 블랙/섬유강화 복합재료의 전자파 차폐효과에 관한 연구)

  • Han Gil-Young;Kim Jin-Seok;Ahn Dong-Gyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.8 s.185
    • /
    • pp.100-107
    • /
    • 2006
  • The objective of this research is to investigate the electromagnetic interference(EMI) shielding characteristics of fiber reinforced composites. We fabricated glass and carbon fiber reinforced composites filled with metal powder and nano carbon black. The measurements of shielding effectiveness(SE) were carried out frequency range 300MHz - 1GHz for commercial purposes such as electric or telecommunication devices. The return loss and loss due to absorption were also measured as a function of frequency in the micro wave(300MHz-1GHz) region. It is observed that the SE of the composites is the frequency dependent, increase with the increases in filler loading. The Mg metal powder filled composite showed higher SE compared to that of carbon black. The Mg metal powder/epoxy composite was shown to exhibit up to 40dB of SE. The results indicates that the composite having higher filler loading can be used for the purpose of EMI shielding as well as for some microwave applications.

Characteristics of copper/C films on PET substrate prepared by ECR-MOCVD at room temperature (상온 ECR-MOCVD에 의해 제조되는 Cu/C박막특성)

  • Lee, Joong-Kee;Jeon, Bup-Ju;Hyun, Jin;Byun, Dong-Jin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.44-53
    • /
    • 2003
  • Cu/C films were prepared at room temperature under $Cu(hfac)_2-Ar-H_2$ atmosphere in order to obtain metallized polymer by using ECR-MOCVD(Electron Cyclotron Resonance Metal Organic Chemical Vapor Deposition) coupled with a DC bias system. The room temperature MOCVD on polymer substrate could be possible by collaboration of ECR and a DC bias. Structural analysis of the films by ECR was found that fine copper grains embedded in an amorphous polymer matrix with indistinctive interfacial layer. The increase in $H_2$ contents brought on copper-rich film formation with low electric resistance. On the other hand carbon-rich films with low sheet electric resistance were prepared in argon atmosphere. The electric sheet resistance of Cu/C films with good interfacial property were controlled at $10^8$~$10^0$ Ohm/sq. ranges by the $H_2$/Ar mole ratio and the shielding effectiveness of the film showed maximum up to 45dB in the our experimental range.

Quasi-3D Capacitance Extraction Methodology for the Multi-layer Interconnects (다층 배선에서의 Quasi-3D 커패시턴스 추출)

  • 진우진;어영선
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.979-982
    • /
    • 1999
  • A new accurate as well as efficient multi-layer interconnect capacitance extraction method is presented. Since Multi-layer interconnects is too complicated to directly extract capacitances, it is simplified with virtual ground concept. To make the structure tractable, the shielding effects should be separately determined. Since the electric field shielding effects, and the solid-ground-based capacitance matrices can be readily determined from the layout geometry, the accurate as well as efficient quasi-3D capacitances concerned with an objective line can be readily determined. In order to demonstrate its efficiency and accuracy, the parameters and circuit responses were benchmarked with 3D-field-solver-based results.

  • PDF

Preparation of Conductive Silicone Rubber Sheets by Electroless Nickel Plating (무전해 니켈도금에 의한 도전성 실리콘고무 시트의 제조)

  • Lee, Byeong Woo;Lee, Jin Hee
    • Journal of the Korean institute of surface engineering
    • /
    • v.47 no.5
    • /
    • pp.269-274
    • /
    • 2014
  • Electroless plating process as a solution deposition method is a viable means of preparing conductive metal films on non-conducting substrates through chemical reactions. In the present study, the preparation and properties of electroless Ni-plating on flexible silicone rubber are described. The process has been performed using a conventional Ni(P) chemical bath. Additives and complexing agents such as ammonium chloride and glycine were added and the reaction pH was controlled by NaOH aqueous solution. Ni deposition rate and crystallinity have been found to vary with pH and temperature of the plating bath. It was shown that Ni-films having the high crystallinity, enhanced adhesion and optimum electric conductivity were formed uniformly on silicone rubber substrates under pH 7 at $70^{\circ}C$. The conductive Ni-plated silicone rubber showed a high electromagnetic interference shielding effect in the 400 MHz-1 GHz range.