• Title/Summary/Keyword: Electric power loss

Search Result 595, Processing Time 0.034 seconds

Fast Running System Code Development to Simulate Transient Behavior of Pool-Type LMFBRs (풀형 고속증식로의 과도 현상을 모사하는 Fast Running System Code개발)

  • Youg Bum Lee;Soon Heung Chang;Mann Cho
    • Nuclear Engineering and Technology
    • /
    • v.17 no.1
    • /
    • pp.16-24
    • /
    • 1985
  • A computer model is developed capable of simulating the transient behavior of a pool-type liquid metal-cooled fast breeder reactor (LMFBR). The model, SIMFARP, is a fast running computer code which may be used to simulate the loss of power to any pump(s), a complete loss-of-forced cooling, and the natural circulation behavior. Eight governing equations are derived and a Runge-Kutta algorithm is applied to integrate the eight differential equations. The developed computer program is applied to two cases; loss of electric power to any pump(s), and loss of all external electric supply power without scram in Super-Phenix-I.

  • PDF

Characteristic comparison of double-side PMSM/G according to magnetization pattern for flywheel energy storage system (플라이휠 에너지 저장 시스템용 양측식 영구자석 동기 전동/발전기의 착자 형태에 따른 특성 비교)

  • Jang, Seok-Myeong;Choi, Ji-Hwan;You, Dae-Joon;Seong, So-Yeong;Han, Sang-Chul;Lee, Jeong-Phil
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1021-1022
    • /
    • 2011
  • This paper presents the double side PM synchronous motor/generator for core loss reduction in flywheel energy storage system. The use of double PM rotor causes the elimination of core loss in no-load state of machine. Because flywheel rotational speed is reduced by core loss, double PM rotor is very effective in flywheel system. This paper suggests two types of double side PM rotor, Halbach magnetized array and parallel magnetized array. And characteristic comparison according to thickness of rotor back core is performed.

  • PDF

Electrical Properties of Plasma Polymerized Hexamethyldisiloxane Thin Film (플라즈마 중합법에 의한 헥사메틸디실록산 박막의 전기적 특성)

  • 이상희;이덕출
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.1
    • /
    • pp.43-47
    • /
    • 2001
  • Plasma polymerized hexamethyldisiloxane thin film was fabricated by employing an inter-electrode capacitively coupled type apparatus under the following conditions : carrier gas flow rate of 11 sccm, reaction pressure of 0.1 torr, discharge frequency of 13.56 MHz and discharge power of 30∼90 W. Polymerization rate of thin film fabricated at the discharge power of 90W is 32.5nm/min. Relative dielectric constant and dielectric loss tangent of thin film shows 3.2∼3.8 and 2.6x10$\^$-3/∼4.51x10$\^$-3/ respectively in the frequency range of 1 kHz∼1 MHz. As the annealing temperature is increased, the relative dielectric constant gradually decreases while the dielectric loss tangent increases. The current density increase gradually with increasing annealing temperature and electric field. The electric conduction of the heaxamethyldisiloxane thin film shows Schottky effect.

  • PDF

The Operating Characteristics of 3kW Utility Interconnected Photovoltaic System (3kW 계통연계형 태양광발전시스템의 운전특성)

  • Kim, Hyung-Seok;Park, Jeong-Min;Na, Jong-Deok;Baek, Hyung-Rae;Cho, Geum-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.201-204
    • /
    • 2004
  • Consider the optimal design for PV system, it is apply to 3kW interconnected electric power PV system, that is a point of reference for 3kW PV the spread residential section system. Through the driving various practical system, we look into that for efficiency of generation and stability of interconnected system. Using obtained data acquisition, It can be suggest that installation and management for system parameter to optimal design maximum generation electric power. PV system have some losses that are variation radiation, shadow, change temperature, unbalanced grid connection, serial circuit loss, MPP deference loss, PCS loss and so forth. Using obtained various performance characteristic result, we can make database in the future, through the this study, we can get the reliance and have regard to spread PV system.

  • PDF

The Study of the Harmonic Currents Effects on the Transformer Vibration (고조파 전류가 변압기 진동에 미치는 영향에 관한 연구)

  • Kim, Su-Yeol;Kim, Yeon-Whan;Kim, Jang-Mok;Lim, Ik-Hun;Lee, Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.1
    • /
    • pp.106-111
    • /
    • 2000
  • EP(Electrostatic Precipitator) has been used to keep the natural environment from fly-ash in the industrial fields and operated in intermittent PEC(Pulse Energized Control) mode to improve dust-collecting efficiency. Intermittent PEC mode induces low-frequency harmonic currents into power system, therefore EP transformer vibrates. This continuous transformer vibration developes transformer abnormal audio-noise and if it is too much or operates in the region of natural frequency, transformer will be damaged in the end. EP interruption caused by transformer damage results in power generation stopped, power quality down and economic loss. Therefore, this paper explains harmonic currents and transformer vibration-core vibration, winding vibration, and proposes the measures of suppressing the vibration with EP operated in intermittent PEC mode. And this results is proposed to be used for future EP transformer design or EP control method to operate EP-concerned equipment safely keeping from system faults caused by transformer vibration.

  • PDF

Characterization of Potassium Based Dry CO2 Sorbents Developed for the Reduction of Side Reactions (부반응 저감 조성 K계 건식 CO2 흡수제 특성평가)

  • Jang, Young-shin;Kim, Ui-sik;Yoon, Yang-no;Baek, Jeom-In
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.4
    • /
    • pp.337-341
    • /
    • 2019
  • In this study, the effects of two materials, active alumina and CaO based inorganic binder, which cause the side reaction on the K2CO3-based solid CO2 sorbents was investigated. K2CO3-based solid sorbents called KAM series was prepared by spray drying method and then measured its physical properties and CO2 sorption capacity. Among the KAM series sorbents, KAM(0.5) maintained high CO2 sorption capacity of 7.6 wt% after 3 cycle of sorption/regeneration reaction and showed very low attrition loss as low as 3.1 % which was measured by ASTM D5757-95.

A study of transient characteristics during the transfer of the source of electric power in UPS (UPS에서 전원 절체시 과도특성에 관한 연구)

  • Lee, Young-Soo;Lee, Kan-Woon;Cha, Jae-Man
    • Proceedings of the KIEE Conference
    • /
    • 2005.07e
    • /
    • pp.88-90
    • /
    • 2005
  • There are a lot of troubles during the transfer of the source of electric power in UPS (uninterruptible power supply system) which is indispensable to the industrial equipments. They cause blackout accidents, resulting in a great economic loss. After measuring and analyzing the transient phenomena happening during the transfer, this paper presents the solution of the troubles. The solution can be used as a basic material for maintenance and it can minimize the troubles occurring in UPS and enhance the reliability of it.

  • PDF

A Method to Allocate Real Power Losses of Transmission Lines using Loss Distribution factors (손실배분계수를 이용한 송전선로 유효전력 손실의 배분법)

  • Ro, Kyoung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1259-1261
    • /
    • 1999
  • The paper proposes a simple method to calculate the portion of real power losses allocated to individual loads. The method is implemented by loss distribution factors, and analyses the share of loads in transmission line losses. Effectiveness of the algorithm is verified by a computer simulation. The results can be used to compute the cost of ancillary services under deregulated environment in electric power industries.

  • PDF

A Study on Thimble Plug Removal for PWR Plants

  • Song, Dong-Soo;Lee, Chang-Sup;Lee, Jae-Yong;Jun, Hwang-Yong
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.611-616
    • /
    • 1997
  • The thermal-hydraulic effects of removing the RCC guide thimble plugs are evaluated for 8 Westinghouse type PWR plants in Korea as a part of feasibility study: core outlet loss coefficient, thimble bypass flow, and best estimate flow. It is resulted that the best estimate thimble bypass flow increases about by 2% and the best estimate flow increases approximately by 1.2%. The resulting DNBR penalties can be covered with the current DNBR margin. Accident analyses are also investigated that the dropped rod transient is shown to be limiting and relatively sensitive to bypass flow variation.

  • PDF

The development of optimal operating system in distribution networks based on distribution automation (배전자동화 기반의 배전계통 최적운전 기법 개발)

  • Ha, Bok-Nam;Seol, Ieel-Ho;Jung, Mi-Ae;Shin, Ick-Su;Lee, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.427-429
    • /
    • 2003
  • The reliability performance of distribution networks will be enhanced with the installation of application programs including feeder reconfiguration program for loss minimization and optimization of system capacity. Although the basic functions of remote monitoring and remote control provide no measurable cost benefit the suite of application programs developed and now being commissioned by KEPCO, the future will continue to offer this utility with substantial savings in system operational costs, improve system reliability and customer service.

  • PDF