• Title/Summary/Keyword: Electric power equipments

Search Result 218, Processing Time 0.028 seconds

A Case Study of Harmonics in Electrical Installations of Buildings (건축물 전기설비의 고조파에 관한 사례연구)

  • 고희석;김성삼;이현무;김주찬;류희석
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.283-288
    • /
    • 2003
  • This paper presents the result of survey of case study for Harmonics in electrical Installations of buildings. Recently, many power electronic equipments(power converter, computers, air conditioners electronic ballasts for fluorescent lamps and so on) are used in office buildings, and harmonic current from them influence the other equipments in a distribution line. Notably, voltage distortion or voltage harmonics may approach or exceed is allowable level in power distribution system. Individual electric power consumers and end-users and responsible for reducing current harmonics while companies or utilities are responsible for reducing voltage harmonics at the point of common coupling in distribution system. As for harmonics, which one of the electric power qualities, it becomes important to obtain harmonic voltage/current distribution of the power system precisely because the use of power electronic apparatus in increasing. However, there are some difficulties on evaluating the measured data in comparison with the simulated result. The primary cause was indentitied with the resonance of harmonics form many sources. To suppress harmonics in electrical installations of buildings, one of many methods suggest that resonance frequencies are controlled by modulating the capacities of high-voltage customer's capacitors.

  • PDF

Survey and Analysis of Electric Power Use pattern in Industry (산업용 전력사용실태 조사분석)

  • Park, Jong-Jin;Rhee, Chang-Ho;Kim, Chang-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.383-385
    • /
    • 2001
  • This paper presents electric power use pattern by end-use for each industry in Korea. Until now, the survey for industrial electric power use pattern by end-use has been sporadic and unsystematic. This paper presents the systematic survey and analysis for electric power use pattern by end-use. The major survey items include rate power and the number of equipments, and operation rate, etc. This paper will make good use of data base construction and policy for DSM.

  • PDF

Design and Application of Electric Field Sensor for Measuring PD Signals in High Voltage Equipments (고전압설비에서 발생하는 부분방전 검출용 전계센서의 설계 및 특성 검토)

  • 이강원;강성화;임기조
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.10
    • /
    • pp.431-435
    • /
    • 2003
  • It is very difficult and dangerous to measure PD(Partial Discharges) from high voltage equipments in outdoor situation. But that is very important thing for preventing them from more serious accident by defects made by insulating degradation. This paper provides useful method to detect PD signals easily without any dangerous situation. Electric field sensor by the principle of capacitor can detect PD signals without direct connection between sensor and high voltage equipment and has very wide frequency range suitable for noise rejection. Electric field sensor and related circuit for processing PD signal show good performance as a PD sensor when it is applied to simulated high power equipment generating PD pulses.

Component Replacement Ordering Evaluation for Proper Reliability Maintenance in Power Distribution System (배전계통 적정 신뢰도 유지를 위한 설비교체 순위 평가)

  • Lee, Hee-Tae;Kim, Jae-Chul;Moon, Jong-Fil;Chu, Cheol-Min
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.48-50
    • /
    • 2005
  • New environment change of electric power system focused in consumer's energy supply and demand. But electric power reliability preservation and reliability improvement countermeasure also need for long-term. It is need that change equipments that is composing electric power system in well-timed time and by maintaining, prevent breakdown beforehand and prevent consumer's power interruption by equipment fail. However, as only quantitative estimation is available by reliability estimation method that is presented in existing, it is no to use in dictionary fault prevention. Therefore, applied optimum reliability preservation through existent equipment fault data analysis of electric power system in equipment replace side, and this when maintain equipment replace of electric power system for reliability preservation using responsiveness analysis to base ordering evaluate. In existing about main equipment plain that this paper is power system the valued failure rate use this by score and precedence of electric power system equipment for replace of system considered expense.

  • PDF

Experimental Research on the Altitude Performance of an Auxiliary Power Unit for Helicopters (헬리콥터용 보조동력장치 고공성능에 관한 실험적 연구)

  • Kim, Chun-Taek;Cha, Bong-Jun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.5
    • /
    • pp.20-26
    • /
    • 2012
  • An APU(Auxiliary Power Unit) for helicopters has been developed in Korea and tested at the AETF(altitude engine test facility) in KARI(Korea Aerospace Research Institute) for the purpose of the military qualification. A cell correlation test was performed before the official test, and the results are within the tolerance. The APU has the capability of supplying electric power as well as compressed air to the helicopters. It was tested at bleed extraction conditions, electric power extraction conditions, and maximum continuous concurrent power conditions within the entire helicopter flight envelop. Some special test equipments were implemented for the measurement of air flowrate, electric power and so on. The tests were successfully performed and their results satisfy the requirements of the helicopters.

An Estimation of Age-, Power-, and Type-Specific Emission Inventories for Construction Equipments Using Improved Methodologies and Emission Factors (배출계수 개발 및 배출량 산정 체계 고도화를 통한 건설기계의 연식, 출력 및 기종별 대기오염물질 배출량 산정)

  • Jin, Hyungah;Lee, Taewoo;Park, Hana;Son, Jihwan;Kim, Sangkyun;Hong, Jihyung;Jeon, Sangzin;Kim, Jeongsoo;Choi, Kwangho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.6
    • /
    • pp.555-568
    • /
    • 2014
  • The construction equipment is one of the major sources for hazardous air pollutants in Korea, and the its management has been of great concern recently. The objective of this study was to estimate each contribution of emission of construction equipments according to their production year, electric power consumption and type. To achieve this goal, we developed pollutant emission factors for the machineries manufactured after 2009, which are excluded from the present framework of Korean air pollutants inventory, CAPSS. More than 800 data obtained from emission investigations were utilized for the estimation. Compared with the previous estimation, the scheme used this study was modified to incorporate new emission factors as well as to include the corresponding activity data. Such improvement allow us to gain more detailed emission informations which are better characterized by specifications of construction equipments. The total amount of pollutants emitted from construction equipments in 2011 were estimated as 126.8, 7.0, 58.3, and 17.0 kton for $NO_x$, PM, CO, and VOC, respectively. The estimation results indicate that the increase in the emission of equipments is significantly related to their age and power consumption. The emissions of the older ones manufactured from 1992~1996 were estimated to be the contribution ranged from 23.7% to 26.8%, whereas the newer ones (2009~2011) showed the attributions of 11.3~21.5%. In addition, the results show that the emission of each equipment was increased with the increase in the electric power consumption of engine, probably due to their average output power. Among the nine types of machinery compared, excavators and forklifts were investigated to contribute relatively higher emissions in the level of 39.8~44.0% and 32.0~34.2%, respectively.

Patent map development of High-efficiency electric machineries (고효율 전기기기 특허동향 분석)

  • 박종진;이창호;김남정
    • Proceedings of the Korea Technology Innovation Society Conference
    • /
    • 2000.11a
    • /
    • pp.177-193
    • /
    • 2000
  • In foreign countries, high-efficiency electric machineries have been developed in view of cost reduction, environmental issues, energy conservation etc. Especially they focus on developing energy conservation measures and demand-side management. Thus, patent application and secure of patent claims are on the rise as important issues in this field. In this paper, we analyzed patent application trends about inverters, ac/dc converters, reactive power control equipments, high-efficiency transformers and electric ballasts among high-efficiency electric machineries. First, we analyzed general technology trends, and constructed patent technology data. Second, we graphed patent application trends in terms of application years, assignees and nations.

  • PDF

A study on the Wireless Communication System for Korean Next Generation Reactor (차세대원전의 무선통신 적용에 대한 연구)

  • Chi, Mun-Goo;Han, Sung-Heum
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3175-3177
    • /
    • 1999
  • In this study, the wireless communication system configuration and major equipments for KNGR will be introduced. Also the reliability and safety impact on the KNGR will be checked by reviewing /testing the EMI/RFI conditions of wireless communication system, The elements of the wireless communication system are radio exchange, base stations, portable telephone handsets.

  • PDF

A Study on the Safety Diagnosis for Electric Power Systems Using Thermal Imaging Analysis (열화상 분석을 이용한 전력시스템의 안전진단에 관한 연구)

  • Yu, Byeong-Yeol;Kim, Chan-O
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.2
    • /
    • pp.26-31
    • /
    • 2011
  • In this paper, the safety diagnosis using thermal image analysis is described for power equipments. The conventional three-phase comparison method has only provided the results of thermal comparison for the equipments. The proposed method defines the conditions of poor connection by visual checks, and supports the criteria with each thermal rise step. As a result, the thermal difference from $5^{\circ}C$ to $10^{\circ}C$ meant the warning state. In addition, the thermal difference more than $10^{\circ}C$ meant that the connection status was unbalanced. In this case, the countermeasure might be the internal load distribution. If the thermal difference more than $20^{\circ}C$ is observed, it means a hot spot at the poor connection. If the hot spot is observed all over the surface, its cause was the unbalanced load, which made the conductive parts discolored and raised the possibility of oxidization or $Cu_2O$ generation. This diagnostic technology employing thermal image analysis method can be directly applied in the field and ensures the safety of equipments.