• 제목/요약/키워드: Electric load scheduling

검색결과 25건 처리시간 0.025초

산업체 열병합발전시스템에서 최적운전계획 수립을 위한 진화 알고리즘을 이용한 GUI System 개발 (A Development of GUI System for Optimal Operational Scheduling on Industrial Cogeneration Systems Using Evolutionary Algorithms)

  • 정지훈;이종범
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권11호
    • /
    • pp.544-550
    • /
    • 2002
  • This paper describes a strategy of a daily optimal operational scheduling on the industrial cogeneration system. The cogeneration system selected to establish the scheduling consists of three units and several auxiliary devices which include three auxiliary boilers, t재 waste boilers and three sludge incinerators. One unit generated electrical and thermal energy using the back pressure turbine. The other two units generate the energy using the extraction condensing turbine. Three auxiliary devices operate to supply energy to the loads with three units. The cogeneration system is able to supply enough the thermal energy to the thermal load, however it can not sufficiently supply the electric energy to the electrical load. Therefore the insufficient electric energy is compensated by buying electrical energy from utility. In this paper, the evolutionary algorithms was applied to establish the optimal scheduling for the cogeneration systems. Also the GUI System was developed using established mathematics medeling and evolutionary algorithms in order that non-experts are able to establish operational scheduling. This results revel that the proposed modeling and strategy can be effectively applied to cogeneration system for paper mill.

An Emission-Aware Day-Ahead Power Scheduling System for Internet of Energy

  • Huang, Chenn-Jung;Hu, Kai-Wen;Liu, An-Feng;Chen, Liang-Chun;Chen, Chih-Ting
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제13권10호
    • /
    • pp.4988-5012
    • /
    • 2019
  • As a subset of the Internet of Things, the Internet of Energy (IoE) is expected to tackle the problems faced by the current smart grid framework. Notably, the conventional day-ahead power scheduling of the smart grid should be redesigned in the IoE architecture to take into consideration the intermittence of scattered renewable generations, large amounts of power consumption data, and the uncertainty of the arrival time of electric vehicles (EVs). Accordingly, a day-ahead power scheduling system for the future IoE is proposed in this research to maximize the usage of distributed renewables and reduce carbon emission caused by the traditional power generation. Meanwhile, flexible charging mechanism of EVs is employed to provide preferred charging options for moving EVs and flatten the load profile simultaneously. The simulation results revealed that the proposed power scheduling mechanism not only achieves emission reduction and balances power load and supply effectively, but also fits each individual EV user's preference.

공동주택에서의 전기자동차 충전기 수용률 설정과 그 제어방법 (Set up a Demand Factor of EV Chargers and Its Control Method in Apartments)

  • 김명수;홍순찬
    • 조명전기설비학회논문지
    • /
    • 제28권8호
    • /
    • pp.98-105
    • /
    • 2014
  • In this paper, we have analyzed the power consumption property of EVs(Electric Vehicles) chargers established in a public place, proposed reasonable demand factors by the number of established EV chargers and its control method in apartments. The optimization of power system and the suppression of the peak load can be controlled through the proposed demand factors and charging scheduling control algorithm. In this paper, electrical design and an case analysis were carried out on a sample apartment complex to prove the effectiveness of the power system. As a result, emergency power transformer capacity has been reduced by approximately 25%, and we have confirmed that the electric rates saving and the control of peak load value is possible.

서로다른 발전방식으로 운전되는 산업용 열병합발전시스템의 최적운전계획 수립 (Operation Scheduling of Industrial Cogeneration System with Each other Generation Mode)

  • 정지훈;이종범;오성근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.354-356
    • /
    • 2000
  • This paper describes the strategy of a daily optimal operational scheduling on cogeneration systems with each other generation mode. The cogeneration systems consists of three generators. auxiiiary devices which are three auxiliary boilers, two waste boilers and three sludge incinerators. One unit that using the back pressure turbin generates the electrical and the thermal energy. The other two units that using the extraction condensing turbine generate the energy. Auxiliary devices operate to supplement the thermal energy to the thermal load with three units. The cogeneration system has a large capacity which is able to supply enough the thermal energy to the thermal load, however the electric power generated is insufficient to satisfy the electrical load. Therefore the insufficient electric energy is supplemented by buying electrical energy from the utility. Simulation was carried out using optimization toolbox. The result reveals that the proposed modeling and strategy can be effectively applied to cogeneration systems with each other generation mode.

  • PDF

전력 피크 감소를 위한 스케줄링 알고리즘의 성능 평가 및 분석 (Evaluation and Analysis of Scheduling Algorithms for Peak Power Reduction)

  • 성민영
    • 한국산학기술학회논문지
    • /
    • 제16권4호
    • /
    • pp.2777-2783
    • /
    • 2015
  • 전력 피크 감소는 전력 공급자 뿐 아니라 사용자에게도 점점 중요한 기술이 되고 있다. 전기 부하 스케줄링은 기기의 주기적 작동 시간을 여러 개의 시간 조각들로 분리하고 여러 기기들에 대해 작동 시간 조각들을 통합적으로 교차 배치하여 전력 피크를 줄이는 기법이다. 본 논문에서는 부하 스케줄링 알고리즘인 EDF, LSF, TCBM, lazy 스케줄러의 성능을 분석하고 개선 방안을 제시한다. 분석을 위해 스케줄링 정책들을 분산제어 시뮬레이션 환경에서 구현하고, 실제 전력 사용 데이터를 이용한 광범위한 실험을 통해 전력 편차, 스위칭 횟수, 온도 범위 위반 비율 등의 관점에서 스케줄링 정책별 성능 특성을 논한다. 또한, 과도한 스위칭 방지를 위해 제한적 선점 기능을 제안하고 그 효과를 입증한다. 실험결과, 스케줄러 용량을 실제 전력 요구에 맞춰 설정하면 성능이 극대화됨을 확인하였으며, 스케줄링을 통해 150W 보다 큰 전력편차를 가지는 비율이 원래 21.5%에서 3.2%까지 감소함을 알 수 있었다.

전기자동차 완속충전기용 스마트 분전반 및 그 제어방법 (Smart Panel Board for EV Standard Chargers and Its Control Method)

  • 김명수;홍순찬
    • 전력전자학회논문지
    • /
    • 제19권6호
    • /
    • pp.511-521
    • /
    • 2014
  • This study proposes an electric vehicle (EV) smart panel board and its control method on the basis of charging scheduling. The proposed system consists of batteries, a three-phase battery charger, three single-phase inverters, transfer switches for electric power distribution, and a controller. The three-phase battery charger usually charges the batteries at midnight when electric rates are cheap and in light load. When the electric power consumption of the EV standard chargers connected to one phase of the power line is relatively large or when a blackout occurs, the electric power stored in the battery is supplied by discharging through the inverters to the EV standard chargers. As a result, the value of peak load and the charging electric power quantity supplied from a utility grid are reduced, and the current unbalance is improved. The usefulness of the proposed system is confirmed through simulations, experiments, and case studies.

Optimal Voltage and Reactive Power Scheduling for Saving Electric Charges using Dynamic Programming with a Heuristic Search Approach

  • Jeong, Ki-Seok;Chung, Jong-Duk
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.329-337
    • /
    • 2016
  • With the increasing deployment of distributed generators in the distribution system, a very large search space is required when dynamic programming (DP) is applied for the optimized dispatch schedules of voltage and reactive power controllers such as on-load tap changers, distributed generators, and shunt capacitors. This study proposes a new optimal voltage and reactive power scheduling method based on dynamic programming with a heuristic searching space reduction approach to reduce the computational burden. This algorithm is designed to determine optimum dispatch schedules based on power system day-ahead scheduling, with new control objectives that consider the reduction of active power losses and maintain the receiving power factor. In this work, to reduce the computational burden, an advanced voltage sensitivity index (AVSI) is adopted to reduce the number of load-flow calculations by estimating bus voltages. Moreover, the accumulated switching operation number up to the current stage is applied prior to the load-flow calculation module. The computational burden can be greatly reduced by using dynamic programming. Case studies were conducted using the IEEE 30-bus test systems and the simulation results indicate that the proposed method is more effective in terms of saving electric charges and improving the voltage profile than loss minimization.

입자 군집 최적화를 이용한 전지전력저장시스템의 충·방전 운전계획에 관한 연구 (Study on BESS Charging and Discharging Scheduling Using Particle Swarm Optimization)

  • 박향아;김슬기;김응상;유정원;김성신
    • 전기학회논문지
    • /
    • 제65권4호
    • /
    • pp.547-554
    • /
    • 2016
  • Analyze the customer daily load patterns, be used to determine the optimal charging and discharging schedule which can minimize the electrical charges through the battery energy storage system(BESS) installed in consumers is an object of this paper. BESS, which analyzes the load characteristics of customer and reduce the peak load, is essential for optimal charging and discharging scheduling to save electricity charges. This thesis proposes optimal charging and discharging scheduling method, using particle swarm optimization (PSO) and penalty function method, of BESS for reducing energy charge. Since PSO is a global optimization algorithm, best charging and discharging scheduling can be found effectively. In addition, penalty function method was combined with PSO in order to handle many constraint conditions. After analysing the load patterns of target BESS, PSO based on penalty function method was applied to get optimal charging and discharging schedule.

산업용 열병합발전시스템에서 진화 알고리즘을 이용한 합리적 운전계획 수립에 관한 연구 (A Rational Operation Scheduling Using Evolutionary Algorithm on Industrial Cogeneration System)

  • 최광범;정지훈;이종범
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권10호
    • /
    • pp.494-501
    • /
    • 2000
  • This paper describes a strategy of a daily optimal operational scheduling in cogeneration system for paper mill. The cogeneration system selected to establish the scheduling consists of three units and several auxiliary devices. One unit generates electrical and thermal energy using the back pressure turbine. The rest two units generate the energy using the extraction condensing turbine. Three auxiliary boilers, two waste boilers and three sludge incinerators operate to supply energy to the loads with three units. The cogeneration system is able to supply enough the thermal energy to the thermal load, however it can not sufficiently supply the electrical power to the electrical load. Therefore the insufficient electric energy is compensated by buying electrical energy from utility. When the operational scheduling is performed considering the environmental problem. This paper shows the simulation results for daily operational scheduling obtained using the evolutionary algorithm. This results reveal that the proposed modeling and strategy can be effectively applied to cogeneration system for paper mill.

  • PDF

부하차단량을 고려한 상정사고 절약 최적조류계산 알고리즘 개발 (Security Constrained Optimal Power Flow Incorporating Load Curtailment Schedule)

  • 정구형;강동주;김발호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.801-803
    • /
    • 2005
  • Fundamentally, success of the competitive electricity market is dependent on efficient market design. However, since electricity incorporates various physical constraints as other commodities, the resource assignment (i.e., dispatch scheduling) is also one of requisites for the successful operation of electricity market. Therefore, efficient dispatch scheduling is an important issue to succeed in the deregulated electricity market and the efficiency of this electricity market may be considerably increased by systematic studies on dispatch scheduling algorithm and corresponding constraints, especially system security. Moreover, contrary to traditional vertically-integrated electric power industry condition, since various decision-makings in deregulated electricity market are directly connected with market participants' benefits, only rational dispatch scheduling algorithm can convince these participants. Therefore, it can provide a basis of grievance prevention. In this paper, we propose an algorithm for security constrained dispatch scheduling with respect to load curtailment. Proposed algorithm decomposes the dispatch problem into a master problem corresponding to basecase optimal power flow (OPF) and several subproblems corresponding a series of contingencies using two-stage optimization technique.

  • PDF