• 제목/요약/키워드: Electric load

검색결과 2,074건 처리시간 0.028초

Application of Multi-step Undervoltage Load Shedding Schemes to the KEPCO System

  • Shin, Jeong-Hoon;Nam, Su-Chul;Lee, Jae-Gul;Choy, Young-Do;Kim, Tae-Kyun;Song, Hwa-Chang
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권4호
    • /
    • pp.476-484
    • /
    • 2009
  • This paper deals with improvements to the special protection schemes (SPS) which have been applied to the low probability and high impact contingencies in the Korea Electric Power Corporation (KEPCO) system since 2004. Among them, the SPS for voltage instability in the Seoul metropolitan area is considered in this paper, and is a form of event-based undervoltage load shedding with a single-step scheme. Simulation results based upon a recent event that occurred on 765kV lines show that the current setting values of the SPS have to be revised and enhanced. In addition, by applying response-based multi-step undervoltage load shedding (UVLS) schemes to severe contingencies in the system, more effective results than those of the existing single-step SPS can be obtained. Centralized and distributed UVLS schemes are considered in the simulation. ULTC-based load recovery models and over excitation limiters (OXL) for the KEPCO system are also included in the long-term voltage instability studies.

지역적 특성과 부하특성을 고려한 직접부하제어 알고리즘 (Direct Load Control Algorithm Based Locational and Electric Load Characteristics)

  • 신호성;송경빈;문종필;김재철;남봉우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.264-265
    • /
    • 2006
  • This paper presents direct load control algorithm based locational and electric load characteristics. Direct load control is defined that demand-side management program activities that can interrupt consumer load at the time of annual peak load by direct control of the utility system operator by interruption power supply to individual appliances or equipment on consumer premises. Korean power system is divided into 14-areas considering branches operating in KEPCO, and electric loads are classified into 19 load groups considering interruption costs in this paper. The purpose of proposed method is to decrease social losses by controlling electric loads mainly whose interruption costs are low. It is expected that the proposed algorithm can be used as the countermeasure for the emergency state of the electric power dispatch in a operation point of view.

  • PDF

특수일 이동을 고려한 전기자동차 충전부하의 전력계통 영향에 관한 연구 (A Study on Power System Analysis Considering Special-days Load Mobility of Electric Vehicle)

  • 황성욱;김정훈
    • 전기학회논문지
    • /
    • 제65권2호
    • /
    • pp.253-256
    • /
    • 2016
  • In this paper, the power system with electric vehicles is analyzed considering the mobility and diffusion rate of electric vehicles in the smart grid environment. In the previous studies, load modeling and load composition rates have been researched and the results are applied to develop a new load model to explain the mobility of electric vehicles which could affect on the power system status such as power flow and stability. The results would be utilized to research and develop power system analysis methods considering movable charging characteristics of electric vehicles including movable discharging characteristics which could be affected by the diffusion progress of electric vehicles.

퍼지 논리를 이용한 일일 냉방부하 예측에 관한 연구 (A Study on Daily Cooling Load Forecast Using Fuzzy Logic)

  • 신관우;이윤섭
    • 제어로봇시스템학회논문지
    • /
    • 제8권11호
    • /
    • pp.948-953
    • /
    • 2002
  • The electric power load during the peak time in summer is strongly affected by cooling load, which decreases the preparation ratio of electricity and brings about the failure in the supply of electricity in the electric power system. The ice-storage system and heat pump system are possible solutions to settle this problem. In this study. the method of estimating temperature and humidity to forecast the cooling load of ice-storage system is suggested, then the method of forecasting the cooling load using fuzzy logic is suggested by simulating that the cooling load is calculated using actual temperature and humidity. The forecast of the temperature, humidity and cooling load are simulated, and it is shown that the forecasted data approach to the actual data. Operating the ice-storage system by the forecast of cooling load with night electric power will improve the ice-storage system efficiency and reduce the peak electric power load during the summer season as a result.

The Study of the Stray Load Loss and Mechanical Loss of Three Phase Induction Motor considering Experimental Results

  • Kim, Dong-Jun;Choi, Jae-Hak;Chun, Yon-Do;Koo, Dae-Hyun;Han, Pil-Wan
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.121-126
    • /
    • 2014
  • The accurate determination of induction motor efficiency depends on the estimation of the five losses of stator and rotor copper loss, iron loss, mechanical loss and stray load loss. As the mechanical and stray load losses are not calculated by electro-magnetic analysis, the values of these two losses are very important in induction motor design. In this paper, the values of mechanical loss and stray load loss are proposed through investigating testing data from commercial products of three phase induction motors under 37kW. If the values of this paper are applied to motor design, the accuracy of design and analysis can be improved. The losses of motors are obtained by using load and no-load test results following IEC 60034-2-1 standard.

스마트 플레이스 부하모델 개발을 위한 이동성 부하 및 보급패턴에 관한 연구 (A Study on Mobility Loads and the Deployment Patterns for the Development of Smart Place Load Model)

  • 황성욱;송일근;김정훈
    • 전기학회논문지
    • /
    • 제63권2호
    • /
    • pp.217-223
    • /
    • 2014
  • Recently, various researches and projects about electric vehicles are in progress vigorously and continuously and it is expected to penetrate rapidly with the next a few years. This deployment will cause the change of load composition rate affecting on power system planning and operations. Therefore, a new load model should be developed integrating with electric vehicle loads. In this paper, the load composition rate of residential sectors is analyzed considering the deployment of this mobility load such as electric vehicles and a new diffusion model is proposed based on the classification of the replacement patterns. Additionally, electric vehicle charging loads are basically modeled by some individual load experiments to develop new load models for smart place and some new conceptual power systems such as micro grids.

한전계통의 부하구성비 분석 (Analysis of Load Composition for KEPCO's Power System)

  • 박시우;김기동;윤용범;추진부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1478-1480
    • /
    • 1999
  • The accurate analysis of power system requires detailed load model. There are two basic approaches in modeling the load characteristics. One is to directly measure the voltage and frequency sensitivity of the load P and Q at substations and feeders. The other is to build up a composite load model from each load component. Each of these methods has advantages and disadvantages. This paper presents load composition for KEPCO's power system to develop load models by the component-based load modeling.

  • PDF

Plant Minimum Stable Load (Pmin) Test for Ilijan CCPP

  • Kim, Si Moon;Yun, Wan No;Jang, Cheol Ho;Park, Se Ik
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권1호
    • /
    • pp.83-88
    • /
    • 2016
  • This paper describes the test results of plant minimum stable load (Pmin) for Ilijan Power Plant. The test was conducted on May 13 through 14, 2015 to investigate the plant operating and equipment condition in accordance with "Ilijan Plant Performance Test Procedure on Plant Minimum Stable Load" [1]. This paper also contains the assessment of the impact of Pmin to plant operating parameters and possible technical operating issues when operating at lower loads and to recommend the safe minimum load operation of Ilijan per block. In addition, this paper describes the performance calculation results of efficiency and heat rate depending on the load level.

비주택용 전기난방기구가 우리나라 첨두부하에 미치는 영향 검토 (Investgating Effects of Peak Load of Korean Power System from Electric Heating appliances except House)

  • 김용하;이광성;허동렬;이성준;이용석;우성민;손승기
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.442-447
    • /
    • 2006
  • This paper investigates the shadow amount of edifice and according to time zone used by its Electric heating appliances, it is analyzed that Electric Heating Power Load affects Heal power load variation curve. Also, in case that the far infrared ray heating system, which are used as new electric heating system, occupies some of the existing Electric heating appliances, it is analyzed that the Electric heating power load affects the Peak load power in Korea.

  • PDF

Short-term Electric Load Forecasting Based on Wavelet Transform and GMDH

  • Koo, Bon-Gil;Lee, Heung-Seok;Park, Juneho
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.832-837
    • /
    • 2015
  • The group method of data handling (GMDH) algorithm has proven to be a powerful and effective way to extract rules or polynomials from an electric load pattern. However, because it is nonstationary, the load pattern needs to be decomposed using a discrete wavelet transform. In addition, if a load pattern has a complicated curve pattern, GMDH should use a higher polynomial, which requires complex computing and consumes a lot of time. This paper suggests a method for short-term electric load forecasting that uses a wavelet transform and a GMDH algorithm. Case studies with the proposed algorithm were carried out for one-day-ahead forecasting of hourly electric loads using data during the years 2008-2011. To prove the effectiveness of our proposed approach, the results were evaluated and compared with those obtained by Holt-Winters method and artificial neural network. Our suggested method resulted in better performance than either comparison group.