LED 가로등 및 보안등기구의 절연특성 연구 (A Study on the Insulation Characteristics of LED Lamps for Load and Street Lighting)

  • 김향곤;길형준;김동욱;김동우
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.546-551
    • /
    • 2009
  • In this paper, we studied insulation characteristics of LED lamps for load and street lighting. LED lamps can be divided into internal type and external type according to converter type. In this study, we analyzed technology standard, K(Electrical Appliances Safety Standards) and KS(Korean Industrial Standards) about insulation resistance for LED lamps for load and street lighting, and measured insulation resistances for each measured point. Mostly, insulation resistances were measured high more than regulation value but some measured points were measured badly. We expect that the results of these experiments would be helpful for electrical safety of LED lighting installation, manufacture, construction and maintenance.

블라인드 PV 제어에 따른 실내 빛환경 및 발전량 측정 (A Measurement of Luminous Environment and Power Generation according to Control Methods of Blind PV)

  • 김소현;손아롬;김인태;최안섭
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.14-21
    • /
    • 2013
  • Today, energy problem has become an important issue, and a development of renewable energy is urgent. In architectural fields, a research of the energy efficient lighting system using renewable energy is in progress. The energy efficient lighting system could be realized by integrating a daylight responsive LED lighting control system and a blind PV system. This system is able to save and generate electric energy. Efficiency of this system depends on control methods of blind PV. As a preliminary research, this research analyzed power generation and inflow of available daylight according to control method of blind PV.

PFC 및 CCR에 의한 항공조명용 전원공급장치의 개발 (A Power Supply System for Lighting of Aerodromes by Using Power Factor Correction and Constant Current Regulator)

  • 손진근
    • 전기학회논문지
    • /
    • 제56권12호
    • /
    • pp.2150-2156
    • /
    • 2007
  • According as level of industry develops day after day, electricity load system of industry requires high level control, effectiveness and high efficiency. Among supply and control unit of suitable power supply in these load characteristic, inverter systems of constant current regulate is used widely control of lighting and electric heating system. But, problems that power factor deterioration and fast response of control, efficiency, harmonics and etc are still remain. Therefore, in this paper proposed an inverter systems with constant current regulation and power factor correction (PFC) circuit for lighting and beaconing of aerodromes. The effectiveness of the proposed system confirmed through experimental results of 10[kW] power supply system.

고 효율, 이종 전원 지원 교류 구동 발광 다이오드 조명 연구 장치 개발 (A Study on AC-Driven LED Lighting System with High Efficacy, and Heterogeneous power)

  • 임준형;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2017년도 춘계학술대회
    • /
    • pp.555-558
    • /
    • 2017
  • 본 논문은 서로 다른 크기의 교류 전원을 인가하더라도 균일한 소비 전력과 광 효율을 나타낼 수 있는 이종 전원 지원 AC LED 구동 장치를 설계 하였다. 서로 다른 크기의 입력 전압과 편차를 설정하여, 두 입력전압에서 전기적 광 특성이 동일함을 확인 하였다. 또한 교류 전원의 피크전압에 따라 특정 LED 구간에서 발생하는 미 점등을 개선하여, 모든 상용 교류 입력 전압에서 전 구간 LED 점등을 구현하였다.

  • PDF

제논(Xe) 가스를 사용한 평판형 광원에서의 전기 및 광학적 특성 연구 (Electrical and Optical properties of Xe gas in flat lighting source)

  • 백광현;양종경;이종찬;최용성;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2190-2192
    • /
    • 2005
  • Discharge of the flat lamp lighting source research are requested very much. For improving brightness, life time, efficiency of flat lamp, plasma diagnosis of the flat lamp lighting source to understand property of lighting source is very important. distance of discharge electrode is 5.5mm and width is 16.5mm, we measured electron temperature and electron density measured with single langmuir probe in flat lamp. we tested the discharge from 100 Torr to 300 Torr pressure. the Pulse is rectangular pulse with frequency 20kHz and Duty ratio 20%. Resultly, electron temperature decreases and electron density increase as increase the gas pressure and electron temperature decreases and electron density increase as increase the voltage.

  • PDF

Fatigue of tubular steel lighting columns under wind load

  • Peil, U.;Behrens, M.
    • Wind and Structures
    • /
    • 제5권5호
    • /
    • pp.463-478
    • /
    • 2002
  • Lighting and traffic signal columns are mainly stressed by excitation due to natural, gusty wind. Such columns typically have a door opening about 60 cm above ground level for the connection of the buried cable with the column's electric system. When the columns around this notch are inadequately designed, vibrations due to gusty winds will produce considerable stress amplitudes in this area, which lead to fatigue cracks. To give a realistic basis for a reliable and economic design of lighting and traffic signal columns, a number of experimental and theoretical investigations have been made. The proposed design concept allows the life of such columns to be assessed with a satisfactory degree of accuracy.

감전사고 방지를 위한 물놀이.입욕시설의 조명설비 시설기준 개선방안 연구 (Improvement of Lighting Installation Technical Standard in Waterpark, Public Bath and Similar Places for the Prevention of Electric Shock)

  • 김종민;김한상;김기현;이건호
    • 조명전기설비학회논문지
    • /
    • 제20권4호
    • /
    • pp.78-85
    • /
    • 2006
  • 물놀이 입욕시설 내에서 입욕자는 물의 영향으로 인하여 인체의 피부저항이 다른 어느 장소보다도 현저히 낮은 상태에 있게 된다. 따라서 조명기구 등에 누전이 발생할 경우 미약한 전압에서도 치명적인 감전재해의 우려가 있다. 본 연구는 물놀이 입욕시설 내에서의 조명기구에 의한 감전사고를 방지하기 위하여 국내 외 관련규정을 비교 분석하였으며 또한, 국내 시설실태를 파악하였다. 그 결과 국내의 규정은 외국기준에 비해 적용범위가 불명확하고 환경조건의 구별이 불투명하고 사용전압이 높은 것으로 나타났다. 따라서 국내의 규정도 조명시설의 설치높이를 상향조정하고 조명기기의 외함에는 방수등급의 표기, 선간전압으로의 사용전압을 제한하는 등의 개정이 필요한 것으로 나타났다.

효율적 시공을 위한 라이트웨이 조명등기구의 작업지시서 개발 (Development of Light-Way Lighting Appliance of Specifications for Efficient Construction)

  • 최충석;고재완
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.18-22
    • /
    • 2009
  • In this paper, we are develop specifications light-way lighting appliance for efficient construction. Analyzed wide application and connection regulation. Also, flickering circuit Presented separation, arrangement, mounting instruction. Incandescent lamp occurs much heat. Therefore, establishment of enough electric light interval is required. Voltage of discharge lamp does by below 300v, and provide so that a person is not can may touched.

  • PDF

모델 사무실의 조명제어 범위에 관한 연구 (A study on Illumination control range of Model Interior)

  • 송언빈;홍규장
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1989년도 추계학술발표회논문집
    • /
    • pp.59-64
    • /
    • 1989
  • Daylight is regarded by most people as preferred light source for interior lig-hting. With poper design, daylight can save electric lighting during daytime. This paper attemptes to show that bett-er use of daylight might be the balanced use of supplementary artificial lighting at times and places where the natural 1-ighting is inadequate with consequent c-ost and energy saving.

  • PDF

교통도로 TUNNEL 조명의 이해 (II) (The Understanding of Road TUNNEL Lighting(II))

  • 이은풍
    • 기술사
    • /
    • 제33권1호
    • /
    • pp.68-74
    • /
    • 2000
  • Until the first stage of the 1990's years, Korean are not concern so much the facilities of traffic tunnel, because of them are the short length and also the quantity of them are not over the several tens in Korea. But, in latest many tunnels has been constructed and are designed in expressway and local national roads. The government office concerned forecast the numbers of tunnel are increased about 300 until the 2003 years, and then we need more interesting about the facilities of tunnel . In the tunnel, the first above of all important facilities is lighting installations which are required much electric energy and continuing maintenance.

  • PDF