• 제목/요약/키워드: Electric lighting

검색결과 266건 처리시간 0.024초

Manufacturing of a Planar Lighting Device Using Cs3Sb Photocathode Emitters

  • Jeong, Hyo-Soo
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권1호
    • /
    • pp.41-45
    • /
    • 2016
  • The Cs3Sb photocathode was formed by non-vacuum process technology and successive in-situ photocathode vacuum device fabrication carried out in a process chamber. Performance testing of the device was followed. Light emission from the devices was induced by photoemitted electrons, which were accelerated by an anode electric field that was shielded from the photoemitter surface. The luminescent characteristics of the devices were investigated by measuring the optical parameters as functions of the applied anode voltages. The results showed that this approach could produce a more easily directed and controlled stream of light. These features make these devices suitable for a variety of planar lighting applications.

Low-Pressure Mercury-Free Fluorescent Lamp for General Lighting

  • Jinno, Masafumi;Lee, Jong-Chan;Motomural, Hideki;Aono, Masaharu;Park, Dae-Hee
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.11-14
    • /
    • 2004
  • In this paper we report on development of our original mercury-less fluorescent lamps for general lighting. These new-type lamps have multi-pairs of electrodes to maintain multi-discharge paths and to keep positive column diffused state. The omission characteristics oft the lamps were investigated. These discharge lamps were operated by pulsed discharge. By using multi-pairs of electrodes for xenon pulsed discharge fluorescent lamps, higher intensity of luminance was obtained than the conventional type of lamps using single pair of electrodes. Recently this type of lamp achieved over $9000\;cd/m^2$ and 50 lm/W.

  • PDF

Mechanism Development and Position Control of Smart Buoy Robot

  • Park, Hwi-Geun;Kim, Hyun-Sik
    • 한국해양공학회지
    • /
    • 제35권4호
    • /
    • pp.305-312
    • /
    • 2021
  • There is a gradual increase in the need for energy charging in marine environments because of energy limitations experienced by electric ships and marine robots. Buoys are considered potential energy charging systems, but there are several challenges, which include the need to maintain a fixed position and avoid hazards, dock with ships and robots in order to charge them, be robust to actions by birds, ships, and robots. To solve these problems, this study proposes a smart buoy robot that has multiple thrusters, multiple docking and charging parts, a bird spike, a radar reflector, a light, a camera, and an anchor, and its mechanism is developed. To verify the performance of the smart buoy robot, the position control under disturbance due to wave currents and functional tests such as docking, charging, lighting, and anchoring are performed. Experimental results show that the smart buoy robot can operate under disturbances and is functionally effective. Therefore, the smart buoy robot is suitable as an energy charging system and has potential in realistic applications.

전기 철도차량용 보조전원장치 시뮬레이터 개발 (Development of auxiliary power supply simulator for electric rolling stock)

  • 김재문;김덕헌;김연충;이상석;신승권
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.889-894
    • /
    • 2005
  • This paper describes the development of the auxiliary power supply simulator for electric rolling stock. Auxiliary power supplies are required for operating air conditioning units, ventilation fans, lighting and battery charging. From the baseline model of the SIV(Static InVerter) for electric rolling stock, we designed the scale down model of the auxiliary power supply simulator consisting of IGBT voltage source inverter. Auxiliary power supply simulator can be used educatory purpose to teach efficiently about operating principles of SIV

마이크로파 방전 무전극 황전등 연구개발 (Development of microwave discharged electrodeless sulfur lamp)

  • 박기준;구선근;추장희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2025-2027
    • /
    • 1999
  • 최근 10여 년간 고광도 방전등 기술은 많은 발전이 있었다. 특히 마이크로파로 방전하는 무전극 황 방전등 (Microwave discharged electrodeless sulfur lamp)은 1990년대 초반 Fusion lighting에 의해 소개된 이후 많은 발전을 거듭하여 왔다. 마이크로 파 방전 무전극 황전등은 마그네트론에서 발생된 2.45 GHz의 마이크로파로 여기된 이원자 황으로부터 방출되는 빛을 조명에 사용한다. 전극이 없어 방전시 전극에 의한 전구의 손상이 없으므로 전구 자체의 수명은 반영구적이다. 이원자 황에서 방출된 빛은 가시광선 영역에서 연속적인 분광분포를 가지며 발광 효율은 100 lumen/W 이상으로 매우 높다. 본 논문에서는 전력연 구원에서 국내 최초로 제작한 마이크로파 방전형 무전극 황전등의 전반적인 특성을 소개한다.

  • PDF

지하철 역사의 안정적 전원공급을 위한 보호시스템 검토 (A study on present status and improvement of protection relay system in subway station for stable power supply)

  • 나종우;조원강;박동선;유연성;문화수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.433-444
    • /
    • 2008
  • Nowadays, subway station has provided not only transportation but living spaces for everyday activities. Therefore, a variety of facilities have been installed for a safety of citizens such as fire-fighting equipment, platform screen doors and giving high level of benefits such as air-conditioning and heating equipment, escalators, lighting apparatus. In order to operate these facilities appropriately, it is needless to say that electric power supply must be reliable. Many protection relays have been installed to protect electric apparatus and power system, nevertheless it..s study has been insufficient in the concrete. From this paper, through analyzing of protection relay system of electric room operated in line 2 of Seoul metro, we can help to improve stable power supply system of subway station.

  • PDF

신개념 뇌경보 시스템 개발 (Development of a New-Concept Lightning Warning System)

  • 최수연;박찬용;길경석;안창환;이영근
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.297-300
    • /
    • 2008
  • This paper described a New-Concept lightning warning system (LWS) which can measure electric field intensity on the ground level by an electric field mill (EFM) and calculate the lighting location by radiated electro-magnetic waveform. The EFM measures electric field up to 20[kV/m] with the sensitivity of 0.15[V/kV/m] and frequency bandwidth of the loop antenna was ranges from 5.2[kHz] to 1.71[MHz]. The LWS provides data on the movements of thunderclouds and the possibility of lightning return stroke.

  • PDF

지하구내 침수시 감전 방지대책 수립을 위한 전기설비 설치 및 관리실태 조사 (An Investigation Into the Actual Condition of Electrical Equipments Installation and Management for Establishing the Countermeasures Against the Electric Shock in Submerged Underground)

  • 정진수;정종욱
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.84-90
    • /
    • 2008
  • This paper describes the investigation into the actual condition of electrical equipments installation and management for establishing the countermeasures against the electric shock in submerged underground. The investigation was carried out for 27 underground premises in conurbation including Seoul, and potential of the exposed electrical equipments negatively affecting on human safety when disaster occurs was measured. The objects to which measurement was carried out were as follows; electrical source; advertising lighting; power equipment. As a result, it was confirmed that potentials more than 230[V] were induced in some equipments. In addition, the electrical equipments installed in most conventional underground premises were left unmanaged.

무전극 형광램프의 페라이트 위치변화에 따른 전기적, 광학적 특성 (Electric & Optical Characteristics of Electrodeless Fluorescent Lamp by Changing Ferrite Position)

  • 이주호;양종경;이종찬;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.244-245
    • /
    • 2007
  • The RF inductive discharge of inductively couples plasma (ICP) continues to attract growing attention as an effective plasma source in many industrial applications, the best known of which are plasma processing and lighting technology. Although most practical ICPs operate at 13.56 [MHz] and 2.65 [MHz], the trend to reduce the operating frequency is clearly recognizable from recent ICP developments. in and electrodeless fluorescent lamp, the use of a lower operating frequency simplifies and reduces cost of RF matching systems and RF generators and can eliminate capacitive coupling between the inductor coil and plasma, which could be a strong factor in wall erosion and plasma contamination. In this study, electric and optical characteristics of electrodeless fluorescent lamp by changing ferrite position is discussed.

  • PDF

뇌운경보장치 개발에 관한 연구 (A Study on Development of the Lightning Warning System)

  • 길경석;송재용;김일권;문승보;차명수
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2006년도 춘계종합학술대회
    • /
    • pp.274-277
    • /
    • 2006
  • This paper describes a lighting warning system (LWS) which consists of a corona needle electrode, a low noise differential amplifier, an A/D converter, an one-chip microprocessor, a LCD and alarm devices. The corona needle electrode is used to measure electric field intensity caused by thunderclouds on the ground level. To evaluate the sensitivity of the LWS, calibration experiment was carried out using a round-shape parallel plate electrode system. The theoretical and experimental results show that the LWS can measure electric field intensity over 2 [kV/m].

  • PDF