• 제목/요약/키워드: Electric insulation material

검색결과 251건 처리시간 0.03초

복합열화에 의한 형권 고정자권선의 절연신뢰성에 관한 연구 (A Study on the Insulation Reliablity of Form-Wound Stator Windings by Complex Degradation)

  • 이헌돈;김상걸;오현석;왕종배;김기준;이준웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.152-155
    • /
    • 2000
  • PWM inverter-fed traction motor is able to occur problems by additive transient surge stress and harmonic loss in contrast with motor driven by 60Hz sine wave alternating source. Therefore in this paper, test method and standard of existed already were investigate, "thermal + electric" complex degradation test that considered additive degradation occurred by inverter drive carried out in order to obtain insulation reliability of traction motor driven by inverter. It seems that this test method confers large value of application at reliability estimation which the subject of complete motor not windings sample from now on.

  • PDF

철도차량 추진시스템의 진단 알고리즘 구현 (Implemention of diagnosis algorithm to traction equipment for railway)

  • 고병훈;박영;권삼영;박현준;김희동
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.500-501
    • /
    • 2007
  • The method of maintenance in railway is going to be changed to improve reliability on traction equipment. Partial discharge (PD) tests are useful to evaluate the insulation condition of stator winding. This paper describes the use of PD tests with 5 model coils which have the defects such as internal, slot discharge. The PD tests are performed with epoxy-mica coupler 500 pF at various AC voltages. The result of test shows PD pattern can correlate with the species of defects on 5 model coils.

  • PDF

여러종류의 에폭시 나노콤포지트 교류절연파괴 강도 및 기계적특성에 대한 연구 (AC Insulation Breakdown Strength and Mechanical properties of Various Types Epoxy-Nanocomposites)

  • 김정호;이병주;윤제환;최태일;최태진;방병윤;박재준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.224-224
    • /
    • 2009
  • 본 연구는 여러종류의 에폭시 나노콤포지트의 절연파괴 강도에 대한 와이블 특성을 연구하였다. 여러 종류 나노콤포지트는 나노입자 형상의 변화 즉, 층상실리케이트(Layered Silicate)와 구상 입자(SiO2)의 충진함량변화를 통한 절연파괴특성을 연구하였다. 나노+마이크로입자에대한 두 개의 체적비를 통한 멀티-나노복합물을 구현하였고, 그 절연파괴 특성의 결과와 기계적특성으로 굴곡강도특성을 Weibull Plot을 통하여 분석하였다. 순수한 나노콤포지트보다 멀티나노콤포지트가 기계적특성에서 월등하게 나타내었고, 절연파괴강도역시 형상파리미터가 대단히 큰 결과를 얻었다.

  • PDF

진공 인터럽터의 차폐판이 절연에 미치는 영향의 유한요소해석 (A Finite Element Analysis on the Influence of Floating Shield of a Vacuum Interrupter to the Insulation)

  • 최승길;심재학;강형부
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 추계학술대회 논문집
    • /
    • pp.113-116
    • /
    • 1998
  • This study should investigate to what extent the electric field of a vacuum interrupter might be influenced by the electric potential of floating arc shield. The electric potentials of floating shield and electric fields of a vacuum interrupter are analysed by a finite element method against variation of gap distances from 1mm to 12mm. The electric potentials of floating shield was increased with the gap distance, which is because the relative position of shield is closer to fixed contact so that the capacitance distribution inside interrupter is varied. The calculated results show that the maximum value of electric field of a vacuum interrupter with floating shield is nearly same to that without shield at shorter gap distance(below 5mm), however at larger gaps a significant increment of electric field is achieved in interrupter with shield companying with model without shield, which is due to the influence of charged floating shield.

  • PDF

고전압용 실리콘고무의 전기적 특성 (The Electrical Properties of High Voltage Silicone Rubber)

  • 김성필;송정우;이종필;이수원;김왕곤;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.779-782
    • /
    • 2000
  • Silicone rubbers are first silicone polymers and has named silicone from existence of Si-O bond similar to Keton. Silicon in organic compound has been called silicone, and linear or network polymers. Silicone rubbers have been used as an power insulator because they are well weather proof, ozone proof and have excellent electric characteristics, thermal stability, cold resistance and low surface energy. Especially, it is known that they have very excellent characteristics at 200[$^{\circ}C$]. For this study, we made silicone rubbers as specimens and we measured dielectric loss tangent due to applied voltage at temperature range 25[$^{\circ}C$] to 180[$^{\circ}C$] and frequency range 20[Hz] to 1${\times}$10$\^$6/[Hz] to examine dielectric properties. We measured dielectric loss tangent to study the insulation performance of silicone rubbers.

  • PDF

식물성 절연유의 전력용 변압기 적용에 따른 문제점 고찰 및 전망 (Problem considerations and expectations in applying vegetable oil to power transformer)

  • 박현수;김지호;이향범
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2009년도 정보통신설비 학술대회
    • /
    • pp.184-186
    • /
    • 2009
  • In past, transformer connection study was concentrated on efficiency improvement and life time broadening. But environmental side began to become important recently. In existing, quick transaction of mineral oil used to insulation oil of transformer is possibility to be difficult and causes environmental pollution in case of was outpoured and there is worry of fire occurrence. Accordingly, nonflammable performance becomes many interest in excellent vegetable oil because ignition point is high than mineral oil and environment friendly material. But, vegetable oil is cooling of transformer and insulation problem of insulating paper for cause of insulation oil special quality. Therefore, in this paper, special quality of vegetable oil that there are being a lot of mineral oil and the latest interest examined about problem and consideration item to be solved to analyzed comparison and applies vegetable oil to transformer for electric power.

  • PDF

송배전용 COMPOSITE INSULATOR의 SHED 재질로서 실리콘 고무 (Silicone Rubber as the Shed Material of Composite Insulator for Electric Power Distribution and Transmission)

  • 강동필
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1367-1369
    • /
    • 1994
  • Recently composite insulators have been In the spotlight because they have many good characteristics as a outdoor insulator for high voltage. The long term properties in composite insulator depend on shed materials. Silicone rubber out of some candidates of shed material has been obtaining good credit from the long term test in field.

  • PDF

초고압 선로 진단장치용 외함 절연설계 (The Insulation Design of Enclosure for Diagnostic Device in Extra High Voltage Line)

  • 김기준
    • 한국전기전자재료학회논문지
    • /
    • 제28권3호
    • /
    • pp.201-207
    • /
    • 2015
  • In this paper, in order to avoid equipment malfunction due to electromagnetic waves, which can occur when high-voltage live line diagnostic device fabrication, the enclosure structure of the diagnostic device with power lines that can minimize the EMI (electromagnetic interference) was modeled using the FEM (finite element method). Simulation examined the strength of the electric field in the required thickness, material and regions where there is a control board while changing the curvature radius of the corner making the enclosure, and By applying a mechanical design and simulation results that occur during the actual production has been designed for the final design. Most of the simulation results for the electric field is concentrated in the final model, the inner edge of the enclosure could be confirmed that the stable structure.

액체질소에서의 극저온 절연매질의 Warm-up/Cool-down 특성 (Warm-up and Cool-down Characteristics of Cryogenic Insulation Materials in Liquid Nitrogen)

  • 이상화;신우주;;오석호;성재규;이방욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.119-119
    • /
    • 2010
  • Among the various factors influencing the service life of the electric equipment, the performance of dielectric insulation materials has an important role to determine their whole service life. In order to determine the degradation of insulating materials immersed in extremely low temperature media such as liquid nitrogen, the abrupt temperature change from cryogenic to normal room temperature should be considered. But the assessments of low-temperature aging test method for the dielectric materials immersed in liquid nitrogen considering these conditions were not fully reported. Therefore, for the fundamental step to establish the suitable degradation test methods for cryogenic dielectric materials, we focused on the evaluation of ageing test methods for dielectric materials exposed to low temperature environments considering thermal shock by cool-down and warm up test.

  • PDF

불평등 전계 시 에폭시와 N2, dry-air 혼합절연체의 절연파괴특성 (Electrical Breakdown Characteristics of Composite Insulation Composed of Epoxy Resins with N2, Dry-air in Non-uniform Field)

  • 정해은;박성희;강성화;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.462-463
    • /
    • 2007
  • SF6 widely used as insulating gas is rising as the environment problem. For decreasing this greenhouse gas, electrical breakdown characteristics of composite insulation composed of epoxy resins with N2, air are studied in non-uniform field. The gap of needle to plane was 3mm, 5mm. The pressure of air, nitrogen was varied within the range of 0.1~0.6MPa. The thickness of a needle is 1mm and the curvature radius of the end of needle is 100um. The diameter of a plane made of the stainless steel is 50mm. As a result of the experiment, the breakdown voltage is increased about 3 times when epoxy resins is composited. The thickness of epoxy resins filled opposite to electrode concentrated electric field weakly influences on breakdown voltage.

  • PDF