• Title/Summary/Keyword: Electric contact

Search Result 700, Processing Time 0.033 seconds

Analysis of a Crack in a Linear Electrostrictive Ceramic Subjected to Electric Fields (전기장을 받는 선형 전왜세라믹 내의 균열해석)

  • Beom, Hyeon-Gyu;Jeong, Gyeong-Mun;Gang, Sang-Hyeon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.2
    • /
    • pp.235-241
    • /
    • 2001
  • A crack with electrically conducting surfaces in a linear electrostrictive ceramic subjected to uniform electric fields is analyzed. Complete forms of electric fields and elastic fields for the crack are derived by using the complex function theory. The linear electromechanical theory predicts overlapping of the traction free crack surfaces. It is shown that the surfaces of the crack are contact near the crack tip. The contact zone size obtained on the basis of the linear dielectric theory for the conducting crack does not depend on the electric fields and depends on only the original crack and the material property for the linear electrostrictive ceramic.

The Prevention of Melting Contact in Accordance Relay of Controller for Turn on/off High Pressure Sodium Vapor Lamp (고압 나트륨램프의 점등과 소등을 위한 제어기의 릴레이 접점의 융착 방지)

  • Han, Tae-Hwan;Woo, Chun-Hee
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.3
    • /
    • pp.148-151
    • /
    • 2004
  • For turn on high pressure sodium vapor lamp, Starting Voltage is very important factor. This starting voltage supply to high pressure sodium vapor lamp as electric discharge lamp, Electric field is producted in electric discharge tube, So accelerative electron collide against vapor atom and second electron is generated, And rapidly the current flow to electric discharge tube. This starting voltage is high voltage and source for melting contact that relay is according as turn on/off high pressure sodium vapor lamp. Consequently, This paper propose that the prevention of melting contact in accordance relay of controller for turn on/off high pressure sodium vapor lamp.

Characteristic Analysis of Non-Contact Reducer for Electric Vehicles using Arago Disc Effect (아라고 원판 효과를 이용한 전기자동차용 비접촉 감속기의 특성 분석)

  • Goon-Ho Choi
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.6_3
    • /
    • pp.1223-1231
    • /
    • 2023
  • In the case of internal combustion engine vehicles, transmissions are essential for various reasons, such as vehicle starting and speed control. However, in the case of electric vehicles, unlike internal combustion engine vehicles, a transmission is not necessarily required. Of course, considering the efficiency of electric vehicles, a transmission is necessary, but installing the existing transmission as is has the opposite effect due to increased vehicle weight, so it has not been considered so far. In this paper, a non-contact reducer type using the Arago disc effect is proposed rather than a transmission using a conventional gear train, and the aim is to examine whether this can increase the driving efficiency of electric vehicles while minimizing weight. In addition, the effectiveness of the proposed reducer will be verified by manufacturing and testing it.

Development of Thermal Precursor DB for Partial Disconnection and Poor Contact on Electrical Wire (배선에서의 반단선 및 접촉불량에 대한 열적 전조 DB구축)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Lee, Jong-Ho;Kang, Dong-Kyu
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.2
    • /
    • pp.30-36
    • /
    • 2009
  • This paper aims at the precursor analysis and DB development of electrical fires based on thermal and current signals for partial disconnection and poor contact on electric wires through experiments and simulations. Also, DB system required for developing the precursor DB with these data was studied and designed. Firstly, in case of partial disconnection, characteristics were derived and analyzed by experiment and electrical-thermal finite element method(Flux 3D) on the model wires which consist of VCTF and IV electric wires. Based on the characteristics, About 351 partial disconnection precursor patterns were generated by the thermal analysis for electric wire according to deterioration time under normal state and 200% overload state of rated current. Secondly, in order to develop poor contact precursor patterns, temperature value and the current signal were considered. In simulating the poor contact situation on connector area of MCCB, connection torque was changed. Through the experimental analysis, about 251 poor contact precursor patterns were generated. Finally, Using thermal precursor patterns obtained by partial disconnection and poor contact, electrical fire thermal precursor DB was developed.

A Study on the Wearing Phenomenon of Pantograph Slider for the SEOUL METRO Line 4 Rail Vehicles (4호선 전동차 판토그라프 주습판 마모현상에 관한 연구)

  • Kim, Young-Gyu;Yang, Yong-Joon
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.51-56
    • /
    • 2007
  • Pantograph of the electric train is the important part receiving current by adhereing contact wire. Wearing rate of pantograph or contact wire is changed by the type of pantograph and material of adhering part. In special, the weather influences the relative wearing rate and wearing type of pantograph Slider and Contact wire with steep wearing in arc and life cycle of pantograph slider. Presently, the weather causes side-wearing and over-wearing of pantograph slide installed in electric train. So it is difficult to manage and operate the electric train. Although the quality of slide using in line4 vehicle was finished the test in line 2 vehicle experimentally, it has to apply after pantograph is installed in some electric trains and check the influence in it and contact wire. It is because line4 section is very different from line2 section. Experimental application is the sequence to certify the safety and abrasion resistance importantly by enlarging experimental application with increase of the experimental electric train. The lenth of line4 in Seoul Metro is 71.5[km]. It is long section. The line is mixed DC 1,500[V] section and AC 25,000[V] section. It has underground section of 41.5[km] and ground section of 30[km]. Ground section is about 42% and receives much influence in the rain during the rainy season. After experimental application we found that this pantograph slide has twice as much abrasion resistance despite a little deviation and found the occurrence probability of arc and side-wearing is decreased considerably.

  • PDF

Countermeasures to prevent contact between phases on overhead lines (가공송전선로 상(相)간 혼촉으로 인한 고장 예방 대책)

  • Park, Yoon-Seok;Kim, Yong-Rak;Kim, Ho-Ki;Kim, Won-Jin;Choi, Jin-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.109-110
    • /
    • 2007
  • Most transmission lines pass through mountainous terrain and deep valleys, to avoid populated areas. Accordingly, the impact of climate changes, environmental conditions and system expansion have caused an increase in transmission line system fault rates. KEPCO has developed and applied phase-spacers to reduce contact faults between phases. Contact between phases represented 9% of total line faults before the devices were installed. Phase-spacers have reduced faults by up to 3.4% since the phase-spacers were installed in 2005. Also, recently developed devices provide additional economic benefits as they cost about a third of the price as similar devices introduced in foreign countries. Phase-spacers are an effective way to prevent phase contact accidents by maintaining physical space between phases. These spacers will be implemented in areas where contacts are likely to occur. They are expected to reduce accident rates and improve power quality.

  • PDF

The Effect of Contact Resistance and Electric Conductivity on PEMFC Performance (접촉저항 및 전기전도도가 연료전지 성능에 미치는 영향)

  • Kim, Ki-Jung;Yun, Yong-Sik;Jeon, Yu-Taek
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.133-136
    • /
    • 2007
  • In this work, 3-dimensional, non-isothermal numerical simulation was performed to analyse the effects of contact resistance and electric conductivity of GDL on the fuel cell performance. For numerical simulation contact resistance of Carbon and Stainless steel was measured. The simulation results reveal that 10 times change of electric conductivity leads only 6.5% decrease of PEMFC performance. But stainless steel which has high contact resistance decrease fuel cell performance over 25% at a high current density region than carbon. This results show that suitable Surface treatment technology is needed for metal bipolar plate, especially stainless steel.

  • PDF

Characteristic Measurement by a Real-time Data Acquisition System in Overhead Contact Wire (실시간 계측시스템을 이용한 전차선로 특성 측정)

  • Na, Hae-Kyung;Park, Young;Cho, Yong-Hyeon;Lee, Ki-Won;Park, Hyun-Jun;Oh, Su-Young;Song, Joon-Tae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.3
    • /
    • pp.281-285
    • /
    • 2007
  • Facilities of electric railway should be maintained only at night and it is necessary to maintain by human power because facilities are installed at a high place. This paper presents the development and application of a real-time data acquisition system for the characteristics measurement of overhead contact wires in electric railway. The system is designed to perform in the telemetry environments that developed to store data by wireless in a live wire state of 25 kV power source. The field test results show that the proposed technique and the developed system can be practically applied to measure characteristics of temperature, displacement, and strain on overhead contact lines.

The Effect of Contact Resistance and Electric Conductivity on PEMFC Performance (접촉저항 및 전기전도도가 연료전지 성능에 미치는 영향)

  • Kim, Gi-Jeong;Yun, Yong-Sik;Jeon, Yu-Taek
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2012.05a
    • /
    • pp.184-186
    • /
    • 2012
  • In this work, 3-dimensional, non-isothermal numerical simulation was performed to analyse the effects of contact resistance and electric conductivity of GDL on the fuel cell performance. For numerical simulation contact resistance of Carbon and Stainless steel was measured. The simulation results reveal that 10 times change of electric conductivity leads only 6.5% decrease of PEMFC performance. But stainless steel which has high contact resistance decrease fuel cell performance over 25% at a high current density region than carbon. This results show that suitable Surface treatment technology is needed for metal bipolar plate, especially stainless steel.

  • PDF

Dielectric Recovery Characteristics between Poles of 800kV Model Interrupter -I. Effects or separation between Moving Main Contact and Moving Arcing Contact- (800kV 모델차단부의 극간 절연회복특성 -I. 가동주접점과 가동아크접점간 이격거리의 변화에 대한 영향분석-)

  • Shin, Y.J.;Park, K.Y.;Chang, K.C.;Song, K.D.;Jeong, J.K.;Song, W.P.;Kang, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.270-273
    • /
    • 1994
  • The capacitive current breaking capability as well as the short circuit current breaking capability is a very important factor in the performance of a circuit breaker. The dielectric recovery capability between poles should be considered in the desist of a circuit breaker because approximately two times of the maximum power system voltage might be applied between poles after the capacitive current be interrupted. The electric field and flow field analyses were utilized in the calculation of dielectric recovery characteristics between poles of 800kV model interrupter. The results show that the separation between moving main contact and moving arcing contact will affect to decrease significantly the electric field strength of a moving arcing contact and an insulation cover, to increase slightly the electric field strength of a fixed arcing contact and to decrease consequently the dielectric recovery capability between poles of the interrupter.

  • PDF