• Title/Summary/Keyword: Electric characteristic

Search Result 1,278, Processing Time 0.025 seconds

The Reliability Evaluation and Outage Cost Assessment of Composite Power System (복합전력계통의 유효부하지속곡선을 이용한 신뢰도 평가 및 공급지장비 추정)

  • Moon, Seung-Pil;Kim, Hong-Sik;Jang, Soon-Ryong;Choi, Jae-Seok;Kang, Jin-Jung;Cho, Jong-Man
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1033-1035
    • /
    • 1998
  • This paper presents a new analytical method for assessing outage cost of composite power system with considering transmission system uncertainty. Composite power system ELDC(CMELDC) was developed and proposed from reliability evaluation of composite power system in order to analysis the outage cost on HLII. In this study, considering the characteristic of each load point, the CMELDC was used for outage cost assessment and reliability evaluation at each load point. The characteristics and effectiveness of this methodology are illustrated by the case study (IEEE-RTS 24Buses).

  • PDF

A Real-T6me Simulator for Power System Studies (실시간 전력계통 해석용 시뮬레이터 기술)

  • Cha, S.T.;Cho, K.W.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1050-1052
    • /
    • 1998
  • As the power systems evolve, they are incorporating increasingly complex control and protection functions. Due to this, utilities are relying more and more on real-time simulators to study complex system interaction problems. This paper addresses some key questions regarding the needs of such simulators and their characteristic features/requirements. In countries like France and Canada, large scale simulators are developed and placed in practical use, and in others are now under development. Following this background, three typical simulators(ARENE, RTDS/HYPERSIM) will be examined focusing on the purpose, technology and experiences in a real-time simulator. Discussion will be extended to the future issues and potentials of the power system simulation.

  • PDF

Study on the Simulation of Grid Connection Type Wind Power System using RTDS (RTDS를 이용한 계통연계형 풍력발전시스템 시뮬레이션에 관한 연구)

  • Kim, Jong-Hyun;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.268-270
    • /
    • 2005
  • A tendency to erect more wind turbines can be observed in order to reduce the environmental consequences of electric power generation. As a result of this, in the near future, wind turbines may start to influence the behavior of electric power systems by interacting with conventional generation and loads. Therefore, wind turbine models that can be integrated into power system simulation software are needed. In this paper, a model that can be used to represent all types of variable speed wind turbines in power system simulations is presented. Wind turbine characteristic equation of a wind turbine is implemented in the RTDS, and the real data of weather conditions are interfaced to the RTDS for the purpose of real time simulation of grid-connection wind power system. The outcomes of the simulation demonstrate the effectiveness of the proposed simulation scheme in this paper. The results show that the cost effective verifying for the efficiency and stability of WPGS.

  • PDF

Study on Reducing Cogging Torque of Interior PM Motor for Agricultural Electric Vehicle

  • Cho, Ju-Hee;Park, Yong-Un;Kim, Dae-Kyong
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.2
    • /
    • pp.134-140
    • /
    • 2013
  • This paper proposes a new design of rotor shape of Interior Permanent Magnet Synchronous Motor (IPMSM) used for agricultural electric vehicle (AEV). The distribution of the residual magnetic flux density at the air gap is modified by rotor surface shape and V-type magnet angle. As a result, cogging torque and physical characteristic have been improved, and back electromotive force (back-EMF) of the suggested model has been improved to be closest to sine wave form compared to initial model. The validity of the proposed rotor shape optimization is confirmed by the manufactured IPM rotor core and measured the performance of the cogging torque.

A Study on the Impedance Calculation by using Equivalent Model in Catenary System

  • Kim, Min-Kyu;Kim, Min-Seok;Kim, Dae-Hwan;Lee, Jong-Woo
    • International Journal of Railway
    • /
    • v.3 no.2
    • /
    • pp.46-53
    • /
    • 2010
  • Electric railroad systems consist of rolling stock, track, signal and catenary system. In the catenary system, one of the most important factors is the impedance according to the design and characteristic. Before the catenary system is designed, the impedance should be precedently researched. The railroad catenary system is complex system which is composed by five conductors. The five conductors classify up and down feeders, up and down contact wire group, rail group. Therefore, we should compose the catenary system of the equivalent five-conductors model. In this paper, we suggest a geometrical model and a equivalent conductor model by using geometric mean radius of five conductors in the catenary system. Also, we calculate demanded parameter values in the model. By using those, line constants of five conductors are analyzed by applying the equivalent method called as the condensed joint matrix.

  • PDF

Physical and Chemical Properties of Cross Linked Polyethylene (Cross Linked Polyethylene의 물리적 및 화학적 성질)

  • 김한주;김규식;박종은;박수길;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.516-519
    • /
    • 1999
  • XLPE (Cross-Linked Polyethylene) which has good electric and physical characteristic is ideal material for Insulating material with force high volumetric resistance arid high dielectric constant. We study abort electric characteristics of XLPE by DCP and TMPTA content ration. DCP (Dicumylperoxide), which was used cross-linked agent contest, was changed from 1.0 to 0.5phr. TMPTA (Trimethyl-olpropane), which was used co cross-linked agent content, was changed from 0.5 to 1.5phr. Thermal analysis by DSC in order to observe tendency of Tg according to DCP and TMPTA content. Specimen 3 that content DCP 2.0phr and TMPTA 0.5phr has the highest value Breakdown strength cf specimen 3 (DCP 2.Ophr, TMPTA 1.0phr) is the highest, value and it increased in specific inductive capacity. This due to difference from cross-linked state by DCP and TMPTA content ratio.

  • PDF

Parallel Operation Control Technique of On-line UPS System (온라인 무정전전원장치의 병렬운전 제어기술)

  • Cho J.S.;Kang B.H.;Gho J.S.;Choe G.H.;Kim J.H.;Chung S.E.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.501-505
    • /
    • 2001
  • The parallel operation system of UPS is used to increase reliability of power source at critical load. But parallel UPS system has a few defects, impedance is different from each other and circulating current occurs between UPSs, due to line impedance and parameter variation, though controlled by the same synchronization signal. According to such characteristic of parallel UPS, balanced load-sharing control is the most important technique in parallel UPS operation. In this paper, a novel power deviation compensation algorithm is proposed. it is composed of voltage controller to compensate power deviation that be calculated by using active and reactive current deviation between inverters on synchronous d-q reference frame.

  • PDF

Generation of Low Temperature Plasma and Its Application (저온 플라즈마 발생과 응용)

  • Lee, Bong-Ju
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.9
    • /
    • pp.413-416
    • /
    • 2002
  • It was reported that low temperature plasma developed by our group was apparently homogeneous and stable at atmospheric pressure, and was generated if the alumina was used as a dielectric insulating material and Ar gas as a plasma gas. This is a structure in which the dielectric materials are covered and arranged in parallel in the one side of electrode. In this experiment, we discovered that dielectric material was important to generate normal electric discharge. To examine the effect of dielectric material on the electric discharge characteristic, the voltage and current of the plasma was measured and the electrical effect of dielectric material was examined. Also, it was applied to an etching of tin oxide films.

Characteristic of Mercury free Flat fluorescent Lamp as Driving frequency (주파수 변화에 따른 무수은 평판 형광 램프의 특성)

  • Lee, Myoung-Ho;Lim, Kee-Joe;Lim, Min-Su;Lee, Mun-Ju
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2075-2078
    • /
    • 2005
  • 본 논문은 무수은 평판 형광램프의 구동원리를 해석하기 위하여 주파수 변화에 따른 벽전하와 벽전압 특성이 방전특성에 미치는 영향을 연구하였다. 펄스폭 $9[{\mu}s]$, 300[ns]의 전압 상승 시간을 갖는 펄스파로 방전시켰다. 벽전하, 정전용량, 벽전압의 전기적 특성은 인가된 전압, 전류 파형으로부터 계산하였다. 이때 구동 주파수는 20[kHz]에서 40[kHz]까지 변화시키면서 방전 전후의 정전용량 및 Q-V특성 곡선을 해석하였다. 주파수가 증가하면서 전극간의 정전용량 $C_p$ 방전공간상의 정전용량 $C_o$는 변화를 보이지 않았으나 방전공간과 전극사이의 정전용량 $2C_g$는 증가하는 경향을 보였다. 또한 주파수가 증가하면서 방전개시 전압은 감소하였으며 효율은 감소하는 경향을 보였다.

  • PDF

Ar Gas properties of Inductively Coupled Plasma for Input Power (유도결합형 플라즈마에서 압력에 따른 Ar Gas의 특성분석)

  • Jo, Ju-Ung;Lee, Y.H.;Her, In-Sung;Kim, Kwang-Soo;Choi, Yong-Sung;Lee, Jong-Chan;Park, Dea-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1704-1706
    • /
    • 2003
  • Low-Pressure inductively coupled RF discharge sources have important industrial applications mainly because they can provide a high-density electrodeless plasma source with low ion energy and low power loss. In an inductive discharge, the RF power is coupled to the plasma by an electromagnetic interaction with the current flowing in a coil. In this paper, the experiments have been focussed on the electric characteristic and carried out using a single Langmuir probe. The internal electric characteristics of inductively coupled Ar RF discharge at 13.56 [MHz] have been measured over a wide range of power at gas pressure ranging from $1{\sim}70$ [mTorr].

  • PDF