• Title/Summary/Keyword: Electric arc

Search Result 560, Processing Time 0.027 seconds

A Study on Kinetic of Volatilization Behavior of Metal Elements Contained in Electric Arc Furnace Dust (전기로 제강분진에 함유된 금속원소의 휘발거동에 대한 속도론적 연구)

  • Yoon, Jaehong;Yoon, Chihyun;Lee, Myungwon
    • Resources Recycling
    • /
    • v.26 no.3
    • /
    • pp.17-25
    • /
    • 2017
  • Electric arc furnace steelmaking dust has various physicochemical properties as volatile components generated in the melting process of steel scraps in an electric arc furnace, which is captured in oxide form as fine powder by reacting with oxygen in the air. In order to efficiently recycle these electric arc furnace dust, a kinetic basic experiment and a pilot production test were carried out in parallel. As a result, it was found that the electric arc furnace dust contain a large amount of Cl and alkali components, thus it was expected that the compounds have a great adverse effect on the actual operation for the recycling. It was confirmed that the volatilization behavior was progressing actively at $1100^{\circ}C$ and the electric arc furnace dust was melted at $1250^{\circ}C$. These results are the same as a result of pilot test for the formation behavior of zinc oxide and reduced iron. These results should be useful as basic data for designing the recycling plant of the electric arc furnace dust and establishing the operating conditions.

Electric Safety Protection Device of High Speed for Incapable Operation of ELB and MCCB Using the Low Voltage Distribution Line (저압 배전선로의 누전 및 배선용 차단기의 오동작 방지를 위한 고속형 전기안전 보호장치)

  • Kwak, Dong-Kurl;Jung, Do-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.11
    • /
    • pp.1925-1929
    • /
    • 2007
  • This paper is studied on a novel Electric Safety Protection Device (ESPD) of high speed for incapable operation of Earth Leakage Circuit Breaker (ELB) and Molded_case Circuit Breaker (MCCB) using the low voltage distribution line. The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Device (RCD), that is ELB and MCCB, of high sensitivity type used at low voltage wiring cuts off earth leakage and overload, but the RCD can't cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied low voltage distribution panel are prescribed to rated breaking time about 30[ms] (KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To be improved on such problem, this research development is proposed to a novel ESPD of high speed to trip of distribution line on electric arc or spark due to electrical fire. Some experimental results of the proposed ESPD are confirmed to the validity of the analytical results.

Arc Detection and Interruption Algorithm Design for Fire Protection (화재 방지를 위한 아크전류 검출 제어기 설계)

  • Ban, Gi-Jong;Won, Young-Jin;Lim, Seung-Ha
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.42 no.3
    • /
    • pp.19-24
    • /
    • 2005
  • Arc Fault Current is an electric discharge which is occurred in two opposite electrode. In this paper, arc current control algorithm is designed for the interruption of arc fault current which is occurred in the local electric network. This arc is one of the main causes of electric fire. Arc fault in electrical network has the characteristics of low current, high impedance and high frequency. Conventional arc current controller does not have the arc current interrupt function. Hence, Controller of arc current is designed for the interruption of arc fault current which has the modified arc characteristics.

Development of Parallel Arc Fault Detector Using Ripple Voltage (리플전압을 이용한 병렬아크 사고 감지기 개발)

  • Choi, Jung-Kyu;Kwak, Dong-Kurl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.5
    • /
    • pp.453-456
    • /
    • 2016
  • The major causes of electrical fire in low-voltage distribution lines are classified into short-circuit fault, overload fault, electric leakage, and electric contact failure. The special principal factor of the fire is electric arc or spark accompanied with such electric faults. This paper studies the development of an electric fire prevention system with detection and alarm of that in case of parallel arc fault occurrence in low-voltage distribution lines. The proposed system is designed on algorithm sensing the instantaneous voltage drop of line voltage at arc fault occurrence. The proposed detector has characteristics of high-speed operation responsibility and superior system reliability from composition using a large number of semiconductor devices. A new sensing control method that shows the detection of parallel arc fault is sensed to ripple voltage drop through a diode bridge full-wave rectifier at electrical accident occurrence. Some experimental tests of the proposed system also confirm the practicality and validity of the analytical results.

A study on working out arc detector related regulations (아크 검출기 관련 규정 마련에 관한 연구)

  • Park, Yong-Seo
    • Journal of Digital Convergence
    • /
    • v.16 no.11
    • /
    • pp.115-122
    • /
    • 2018
  • More than 70% of the electric fire cases happen in this country are caused by arc. This paper aims to prepare measures of preventing electric fires resulted from arc by analyzing the technical standards and related regulations on the existing circuit breaker. Based on the study, we concluded that the technical and legal standards of the arc detector should be separately regulated from those of existing circuit breaker, considering the characteristics of arc detectors. Accordingly, we suggested in this paper that the arc detector related regulations should either be added to the existing circuit breaker related regulations, or to be handled separately. For effective prevention of electric fires caused by arc, it is urgently required to install arc detector and it is, therefore, appropriate to make it mandatory to install an arc detector. Under the given circumstance, it is suggested that the arc detector related regulations should be added to the existing regulations for the circuit breaker. The technical standards of arc detectors should reflect the arc judgement specification, breaking threshold of arc and the range of unnecessary signal that breaker should not react to respond.

The Arc Fault Determination Method for the Electric Fire Prevention (전기화재 방지를 위한 아크고장 판단기법에 대한 연구)

  • Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.3 no.4
    • /
    • pp.260-265
    • /
    • 2008
  • The arc-fault occurring in the customer system becomes the direct cause of electric fire. However, it is very difficult to identify the arc-fault using the existing fault detection mechanism because the magnitude of the fault current is very small. Accordingly, this paper analyzes the causes of arc fault and designs the basic detection mechanism of arc fault. And then, it proposes an signal processing-based arc-fault determination methodology which can enhance the of accuracy of the arc-fault determination by applying DFT/DWT to the voltage and current waveform. Finally, this paper showed the application methodology of the proposed signal processing based fault determination method by applying and analyzing DFT/DWT to an high voltage in-rush current waveform.

  • PDF

Development of Monitoring Program for Detecting Current and Voltage Signals for Series Arc (직렬아크에 대한 전류 및 전압 신호분석이 가능한 Monitoring Program 개발)

  • Kim, Doo-Hyun;Park, Jong-Young;Kim, Sung-Chul;Lee, Jong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.2
    • /
    • pp.29-34
    • /
    • 2010
  • This paper is aimed to develop monitoring software for detecting the characteristics of current and voltage signals for series arc on electric wire. In order to attain this purpose, the characteristics of series arc were analyzed by the current and voltage signals on electric wire which were installed, and also analyzed by the changes of RMS, instantaneous of waveform value in time domain and THD in frequency domain. Monitoring program which analyze the signal was developed by Labview which can analyze in time domain and frequency domain, and save data. Experimental setup for detecting verification of monitoring program was composed loads of a lamp, an electric heater and an electric fan loads which were usually using. Measurement points for detecting verification of monitoring program were selected at both the panel board and the arc generator at the same time. As results of the experiments by monitoring program, the arc current waveform showed the same characteristic in all measurement points of all load. But the arc voltage waveform was different in each measurement point. When arc occurred, the THD of current value increased above 20%. The results of this study will be effectively used in developing the preventive system of electric fire by series arc.

An Influence Arc Shield having on to Electric-field in the VI insides (VI 내부에서 Arc shield가 전계에 미치는 영향)

  • Yoon, Jae-Hun;Kim, Beung-Chuel;Lee, Sung-Su;Lim, Kee-Jo;Kang, Seong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2008.04c
    • /
    • pp.247-248
    • /
    • 2008
  • This paper describes the influence of shield(Arc shield) on the electric fields in a vacuum interrupter(VI). The equipotential line and electric field in a VI are analysed by a finite element method at various shield length. in result, The electric potentials of Arc shield edge was increased because the length too short or long approach the source. it confirmed that equipotential line was influenced that shape and length by end shield. finally this pater proposed to optimal length and shape by arc shield.

  • PDF

An Electric Arc Furnaces Load Model for Transient Analysis (과도현상 해석을 위한 EAFs 부하 무델의 개발)

  • Jang, Gilsoo;Venkata, S.S.;Kwon, Sea-Hyuk
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.3
    • /
    • pp.197-202
    • /
    • 1999
  • Electric arc furnaces (EAFs) use bulk electrical energy to create heat in metal refining industries. The electric arc process is a main cause of the degradation of the electric power quality such as voltage flicker due to the interaction of the high demand currents of the load with the supply system impedance. The stochastic models have described the aperiodic physical phenomena of EAFs. An alternative approach is to include deterministic chaos in the characterization of the arc currents. In this parer, a chaotic approach to such modeling is described and justified. At the same time, a DLL(Dynamic Link Library) module, which is a FORTRAN interface with TACS (Transient Analysis of Control Systems), is developed to implement the chaotic load model in the Electromagnetic Transients Program (EMTP). The details of the module and the results of tests performed on the module to verify the model and to illustrate its capabilities are presented in this paper.

  • PDF

Harmonics Analysis for Electric Arc Furnace According to the Operation Condition (전기 아크로 운전 상태에 따른 고조파 해석)

  • Kim, Jae-Chul;Park, Kyung-Ho;Park, Hyun-Teak;Moon, Jong-Fil;Im, Sang-Kug;Son, Hag-Sig
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.118-125
    • /
    • 2004
  • The use of electric arc furnace has been increasing as the steel consumption is increasing and the operation technique of electric arc furnace are developing. But as the use of electric arc furnace is increased, the furnace have produced the adverse effects of power quality: voltage and current harmonics, voltage and current imbalances, low power factor, and voltage flicker. One of the power quality problems, the harmonic have the characteristics of the time-varying and non-linear. This paper analyzed the harmonics for the various operation conditions of electric arc furnace. The power system model with electric arc furnace have been made, and the harmonic's effects on the power system has been analyzed according to the various operating conditions, first melting, second melting, so on. Also, the filter reducing the harmonic components have been designed and its effects on the power system have been examined.