• Title/Summary/Keyword: Electric apparatus

Search Result 321, Processing Time 0.028 seconds

The Driving Method of Power Switching Device Using Pizoelectric Transformer (전력 Switching 소자를 압전트랜스로 구동하는 방법)

  • Hwang, Min-Kyu;Lee, Sang-Kyun;Lee, Jae-Choon;Choi, Joon-Young
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1324-1326
    • /
    • 1998
  • To drive motor or heating machine, it needs the electric power system like the apparatus of inverter. This electric power system obviously comprises power switching devices and drivers to run them. And this system has the topology comprised one/many arm(s), - each arm has high side switching device and low side switching device. Transformer, photocoupler, and HVIC having functions of isolation and level shift which are important thing to drive high side switching device are used as component of drivers in conventional apparatus. Piezoelectric transformers are proposed in this paper, and applied to drive high side swiching device. Through experiments, the possiblities of driving high side switching device are presented and the problems are mooted concurrently. But, we also consider a counterplan for solving the mooted trouble issues.

  • PDF

The study on the wave-resonance for the bio-KI (생체(生體) 기(氣)의 파동(波動) 공명적(共鳴的)인 연구(硏究) 현황(現況))

  • Kim Gyeong-Cheul;Hong Mi-Suk
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.4 no.1
    • /
    • pp.152-162
    • /
    • 2000
  • The present condition of study on the wave-resonance for the bio-KI is observed. The results are as follows: 1. Tn the wave-resonant stand point, the tendency of studying on KI is showed in the several field all over the world. 2. Because it is originated radionics, the wave-resonant tools of MRA insistenting minute-magnetism-resonance-apparatus need the more severe data in the side of electric circuit. 3. The wave resonance apparatus according to the frequency occurance transmits low-frequency's vibration ratio to the electric stimulating aspect. 4. The wave-water is considered on the application of wave-resonance transcription on the water, and needs the comprehension of torsion-field level.

  • PDF

Multi-physics Analysis for Temperature Rise Prediction of Power Transformer

  • Ahn, Hyun-Mo;Kim, Joong-Kyoung;Oh, Yeon-Ho;Song, Ki-Dong;Hahn, Sung-Chin
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.114-120
    • /
    • 2014
  • In this paper, a method for multi-physics analysis of the temperature-dependent properties of an oil-immersed transformer is discussed. To couple thermal fields with electromagnetic and fluid fields, an algorithm employing a user defined function (UDF) is proposed. Using electromagnetic analysis, electric power loss dependent on temperature rise is calculated; these are used as input data for multi-physics analysis in order to predict the temperature rise. A heat transfer coefficient is applied only at the outermost boundary between transformer and the atmosphere in order to reduce the analysis region. To verify the validity of the proposed method, the predicted temperature rises in high-voltage (HV) and low-voltage (LV) windings and radiators were compared with the experimental values.

Improvement of triggering system of impulse voltage generator for Extra high-voltage (충격전압발생기 트리거 시동장치 성능개선)

  • Heo, J.C.;Park, S.J.;Moon, I.W.;Park, J.W.;Oh, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1704-1706
    • /
    • 2002
  • With increasement of use in electricity energy, quality of electric apparatus has been recognized as important factor in distribution and transmission line. Especially In laboratories, lightning and switching impulse performances of electric apparatus have been carrying out by impulse voltage generator (IVG), simulated into lightning and switching surge circuit. In this paper, we describe triggering system of impulse voltage generator(IVG) for extra high voltage, which has been newly designed.

  • PDF

Sensitivity Analysis for Optimum Shape Design of Electric Apparatus (전기기기 최적형상 설계를 위한 민감도 해석에 관한 연구)

  • Hahn, Song-Yop;Jung, Hyun-Kyo
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.9
    • /
    • pp.859-865
    • /
    • 1991
  • This paper presents a new shaoe optimal design method using Desing Sensitivity Analysis. Design Sensitivity, defined as the variation of the object function with respect to the design variables, is based on the total differentiation of the matrix equation obtained from discretization of governing equations with respect to design variables. Analysis of the various characteristics adn calculation of Design Sensitivity of optimization model are achieved by using finite or boundary element methods. The proposee algorithm is applied to the optimal shape design of high voltage electrode under specified conditions. It is shown, from the numerical results, that the algorithm is very useful for the optimal shape design of electric apparatus.

Charge Carrier Behaviour of Metal-Polymer Interface (금속-고분자 계면에서의 전하의 거동)

  • Yun, Ju-Ho;Choi, Yong-Sung;Ahn, Seong-Soo;Moon, Jong-Dae;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.373-374
    • /
    • 2008
  • Insulating polymers and their composites have been widely used in various electric apparatus or cables. Recently, the effects of interfaces (metal/insulator or insulator/insulator interfaces) on electrical insulation have attracted much attention. However, interfacial phenomena in actual insulation systems and their physical backgrounds are not well understood yet. In this paper, the behaviour of charge carriers near the metal/polymer interface and its effects on conduction and breakdown phenomena are discussed. The metal/polymer interface strongly affects carrier injection, space charge formation and breakdown phenomena. Based on their experimental results, the physical backgrounds of the interfacial phenomena are explained.

  • PDF

The Driving Method of Power Switching Device Using Pizoelectric Transformer (전력 Switching 소자를 압전트랜스로 구동하는 방법)

  • Hwang, Min-Kyu;Lee, Sang-Kyun;Lee, Jae-Choon
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2458-2460
    • /
    • 1998
  • To drive motor or heating machine, it needs the electric power system like the apparatus of inverter. This electric power system obviously comprises power switching devices and drivers to run them. And this system has the topology comprised one/many arm(s), - each arm has high side switching device and low side switching device. Transformer, photocoupler, and HVIC having functions of isolation and level shift which are important thing to drive high side switching device are used as component of drivers in conventional apparatus. Piezoelectric transformers are proposed in this paper, and applied to drive high side swiching device. Through experiments, the possiblities of driving high side switching device are presented and the problems are mooted concurrently. But, we also consider a counterplan for solving the mooted trouble issues.

  • PDF

A study on the performance improving of the dielectric test facilities for UHV heavy electric apparatus (초고압 중전기기 절연시험설비 성능개선 연구)

  • Lee, J.G.;Kim, M.K.;Jeong, J.Y.;Kim, I.S.;Kim, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2100-2102
    • /
    • 2005
  • In this Paper, there have been brief review about the important consideration in laboratory planning and designing the dielectric testing facilities for heavy electric apparatus up to 800kV-class in the high voltage testing fields. To improve and reinforce the existing dielectric test facilities in the way of econo-mical and optimal condition, wide investigation and an analysis for a solution, especially overshoot compensation method. have been suggested. With the brief description about those matters in constructing and improving the test facilities, the specification of each facility has been shown in the paper.

  • PDF

A preliminary study on the construction of 4.2MV IVG for the UHV dielectric test (초고압 절연시험을 위한 4.2MV 충격전압발생장치의 구축방안 검토)

  • Lee, J.G.;Shin, Y.J.;Heo, J.C.;Moon, I.W.;Kim, M.H.;Kang, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1750-1752
    • /
    • 2003
  • This paper, as a preliminary study, presents the important consideration in laboratory planning and designing 4.2MV impulse voltage generator(IVG), which enable to test and evaluate the UHV dielectric performance of power electric apparatus up to 765kv-class. To fix and confirm the kinds of loads and their capacities to be tested by KERI hereafter, wide investigation and an analysis of test objects, especially heavy electric apparatus of Korea, according to their ratings and test voltages have been conducted. With the special consideration concerning other matters in designing of 4.2MV IVG have been described with the practical examples and references.

  • PDF

Development of electric safety control system for incapable operation of ELB and MCB using the low voltage distribution line (저압 배전선로의 누전 및 배선용 차단기의 오동작 방지를 위한 전기안전 제어장치 개발)

  • Kwak, Dong-Kurl;Shin, Mi-Young;Jung, Do-Young;Kim, Hyo-Jin;Baek, Seong-Hyun;Choi, Byung-Seub
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.371-372
    • /
    • 2007
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Device (RCD), that is Earth Leakage Circuit Breaker(ELB) and Molded_case Circuit Breaker (MCB), of high sensitivity type used at low voltage wiring cuts off earth leakage and overload, but the RCD can't cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied low voltage distribution panel are prescribed to rated breaking time about 30[ms] (KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To be improved on such problem, this research development is proposed to a auxiliary control apparatus for RCD trip on electric arc or spark due to electrical fire. Some experimental results of the proposed apparatus is confirmed to the validity of the analytical results.

  • PDF