• 제목/요약/키워드: Electric and magnetic field(EMF)

검색결과 40건 처리시간 0.028초

슬롯등가회로를 이용한 영구자석모터의 순시치 해석법연구 (A Study on the Instantaneous Characteristics Analysis Method of PMSM using Slot Equivalent Circuit)

  • 원성홍;한기수
    • 전기학회논문지P
    • /
    • 제66권1호
    • /
    • pp.1-6
    • /
    • 2017
  • Recently, many motor analysis methods have been developed and studied. Among these methods, the finite element method(FEM) and the analytic method are most popular in field engineers because of the accuracy of FEM and the convenience and rapid analysis time of the analytic method. Contrary, the finite element method has a weakness in calculation time and it is not easy to obtain the instantaneous characteristics value of motor with the analytic method. In this paper, the authors proposes a novel method for calculating the instantaneous characteristics of motors with the magnetic slot equivalent circuit.

신재생 에너지 적용을 위한 고효율 영구자석 동기 전동/발전기의 해석 및 설계 (Analysis and Design of high-efficiency Permanent Magnet Synchronous Motor/Generator for Renewable Energy Application)

  • 유대준;김일중
    • 전기학회논문지
    • /
    • 제60권5호
    • /
    • pp.955-964
    • /
    • 2011
  • In renewable energy system such as flywheel energy storage system, wind power and solar power, the motor/generator is the important key for offering the electric energy to the electric loads. For example, the heavy and large flywheel is rotated by electromagnetic torque of pemanent magnet synchronous motor (PMSM) and, in case of a breakdown of electric current, the PMSM used as generator supplies electric energy for the various electric utilities using mechanical rotation energy of the flywheel. Thus, design of a motor/generator should be performed in effort to reduce cogging torque and electromagnetic loss for high efficiency. In our paper, a slotless permanent magnet synchronous motor/generator (SPMSM/G) with output power 15kW at the rotor speed 18000rpm is designed from electromagnetic analysis and dynamic performance analysis. In analytical approach, design parameters such as back electro-motive force (back EMF), inductance and electromagnetic torque are derived from analytical method which is one of the electromagnetic analysis method. And using the design parameters, this paper deal with system design considering the driving characteristics and electric load in required power. Finally, the analytical results are verified by the experiment and finite element method (FEM).

발전기의 전자기장 분포 특성에 따른 작업자 노출공간 분석 (Analysis of Worker Exposure Space according to Distribution of Electromagnetic Field of Generator)

  • 성민영;김두현;김승태
    • 한국안전학회지
    • /
    • 제36권4호
    • /
    • pp.20-28
    • /
    • 2021
  • With an increase in the commercialization of electricity, and the development of advanced and large electric devices and various wireless radio wave services, concerns over the effects of electromagnetic fields on human health have increased. Accordingly, the World Health Organization encouraged the development of international standards by establishing the 'International Electromagnetic Fields Project' in 1996 based on studies on the harmful effects of electromagnetic fields on the human body. Moreover, the National Institute of Environmental Health Sciences (NIEHS) classified electromagnetic fields as possible carcinogens under Group 2B category, even though they have been found to have a weak correlation with those effects on human health. Mid-to-large-sized electric facilities used at industrial sites mostly adopt a commercial frequency of 60 Hz, and workers handling these facilities are exposed to such extremely low frequency (ELF) fields for a long time. A previous study suggested that exposure to ELF electromagnetic fields with frequency ranges from 0 to 300 Hz, even for a short time, at densities higher than 100 μT may have harmful effects on human body as it affects the activation of nerve cells in the central nervous system by inducing an electric field and current and stimulating muscles and the nervous system in the body. Such studies, however, focused on home appliances used by ordinary people, and research on facilities utilizing high-capacity current and operated by workers at industrial sites is lacking. Therefore, in this study, a 3000 kilowatt generator, which is a high-capacity electric facility employed at industrial sites, was investigated, and the size of the magnetic fields generated during its no-load and high-load operations per distance to produce a map was measured to reveal spots deemed hazardous according to domestic and international exposure standards. The findings of this study is expected to alleviate workers' anxiety about the harmful effects of magnetic fields on their body and to minimize the level of exposure during operations.

반도체 제조 근로자의 극저주파 자기장 노출 평가 (Occupational Exposure of Semiconductor Workers to ELF Magnetic Fields)

  • 정은교;김갑배;정광재;이인섭;유기호;박정선
    • 한국산업보건학회지
    • /
    • 제22권1호
    • /
    • pp.42-51
    • /
    • 2012
  • Objectives: To compare the exposure level of extremely low frequency (ELF) magnetic fields among semiconductor workers, shipyard welders and office workers. Methods: To measure the ELF magnetic field concentration, EMDEX LITE (Enertech, USA) were used and monitored for eight hours continuously. Five companies handling the electric and magnetic field (EMF) source were investigated, which the exposure groups were classified into three groups: semiconductor workers, welders, and office workers. Welder group was chosen as a high exposed group and office group as a low exposed group. Results: The arithmetic mean (${\pm}SD$) and geometric mean (GSD) of personal exposure level of semiconductor workers were 0.73 (${\pm}1.33$) ${\mu}T$, 0.43 (2.88) ${\mu}T$, respectively. The ceiling value ranged between 0.18 and 123.2 ${\mu}T$. Welders were exposed high with the arithmetic mean value of 3.46 (${\pm}\;13.46$) ${\mu}T$ and geometric mean value of 0.45 (4.70) ${\mu}T$, respectively, and ceiling value range of 75.5~129.6 ${\mu}T$. The exposure levels of office workers were low compared to other exposed groups; the arithmetic mean 0.05 (${\pm}0.13$) ${\mu}T$, geometric mean 0.03 (2.38) ${\mu}T$ and ceiling value range 0.37~3.35 ${\mu}T$. This study revealed statistically significant differences of the mean ELF magnetic field exposure doses among three groups (p < 0.01). Conclusions: The average ELF magnetic field exposure doses of semiconductor workers were much higher than those of office workers in control group, but were lower than those of welders in high exposure group.

국내 전철 및 가전제품을 대상으로 한 전자장 수준 실태조사 (A survey on the EMF Levels of Study and Electric Appliances in Korea)

  • 장성기;조용성;이석조;유승화;정경미;임준호
    • 한국산업보건학회지
    • /
    • 제15권1호
    • /
    • pp.71-81
    • /
    • 2005
  • The purposes of this study was to collect, analyze, and describe the MF exposure levels from subways in Korea and to measure and evaluate the MF levels generated from electric appliances used at general homes. The target subway lines were Seoul Metropolitan Line 1 to Line 8, Bundang Line, Incheon Line, Daegu Line, Gwangju Line, and Busan Line 1 and Line 2. We measured at each station in those subway lines and, all the train types (pantograph-equipped, motor-equipped, and common), and platform types(facing and isolating) were investigated by the distance(80, 200, 400 cm) from the train on 19 targeted subway lines using 3 magnetic field measuring devices (EMDEXII, Enertech Co.) during the survey from January till October, 2004. On the other hand, the levels of the 60Hz magnetic fields generated from 14 items of home electric appliances such as electric blankets, hair dryers, electric razors, etc. were measured at 10 general homes using 5 EMDEXII meters with a sampling interval of 1.5 second by the distance(surface, 30, 50, 100, 300cm ) from the target electric appliances. The survey results in the whole subway lines examined in this study were as follows; Seoul Metropolitan Line 4 using AC(alternating current) power source showed the highest mean value of $2.85{\mu}T$, followed by Seoul Metropolitan Line 1 running between Seoul and Incheon using AC($2.78{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Uijongbu using AC($2.73{\mu}T$), Bundang Line using AC($1.79{\mu}T$), Seoul Metropolitan Line 1 connected from Yongsan using AC($1.67{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Suwon using AC($0.79{\mu}T$), and so on. In general, the intensity of the magnetic field in the subway systems in Korea was significantly higher when using AC($2.14{\pm}0.91{\mu}T$) than when using DC($0.29{\pm}0.44{\mu}T$) power source. Among the home electric appliances examined, microwave ovens showed the highest mean value of $7.69{\mu}T$, followed by hair dryers($6.47{\mu}T$), vacuum cleaners($5.27{\mu}T$), televisions ($2.26{\mu}T$), electric blankets($1.38{\mu}T$), personal computers ($0.81{\mu}T$), and so on. Two items of electric appliances showed the excess value of $0.2{\mu}T$ at the distance of 30cm in the MF exposure level; electric razors $1.58{\pm}2.13{\mu}T$ and vacuum cleaners $0.48{\pm}0.44{\mu}T$. As a whole, this study showed a tendency that the shift of the MF levels according to the increase of distance from the electric appliances was lower than those of the results surveyed in UK and USA. As a result, this study is expected to suggest meaningful data for the future study in exposure assessment of magnetic fields and for the establishment of guidelines for subways and electric appliances in Korea. More detailed and large scaled exposure assessment studies should be performed continuously to get the various and useful information on health risk assessment of MFs in Korea.

A Critical Note on the Electric Field in Direct and Alternating Current and Its Consciousness

  • Oh, Hung-Kuk
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2000년도 추계학술대회 논문집
    • /
    • pp.98-104
    • /
    • 2000
  • The conventional model did not take momentum conservation into consideration when the electron absorbs and emits the photons. II-ray provides momentum conservations on any directions of the entering photons, and also the electrons have radial momentum conservations and fully elastic bouncing between two atoms, in the new atom model. Conventional atom model must be criticized on the following four points. (1) Natural motions between positive and negative entities are not circular motions but linear going and returning ones, for examples sexual motion, tidal motion, day and night etc. Because the radius of hydrogen atom's electron orbit is the order of 10$^{-11}$ m and the radia of the nucleons in the nucleus are the order of 10$^{-14}$ m and then the converging $\pi$-gamma rays to the nucleus have so great circular momentum, the electron can not have a circular motion. We can say without doubt that any elementary mass particle can have only linear motion, because of the $\pi$-rays'hindrances, nearthenucleus. (2) Potential energy generation was neglected when electron changes its orbit from outer one to inner one. The h v is the kinetic energy of the photo-electron. The total energy difference between orbits comprises kinetic and potential energies. (3) The structure of the space must be taken into consideration because the properties of the electron do not change during the transition from outer orbit to inner one even though it produces photon. (4) Total energy conservation law applies to the energy flow between mind and matter because we daily experiences a interconnection between mind and body. Conventional Concept of Electric Field must be extended in the case of the direct and alternating current. Conventional concept is based on coulomb's force while the electric potential in the direct and alternating current is from Gibb's free energy. And also conventional concept has not any consciousness with human being but the latters has a conscious sensibility. The cell emf is from the kinetic energy of the open $\pi$-rays flow through the conducting wire. The electric potential in alternating current is from that the trans-orbital moving of the induced change of magnetic field in the wire produces flows of open $\pi$-rays, which push the rotating electrons on the orbital and then make the current flow. Human consciousness can induce a resonance with the sensibility of the open $\pi$-rays in the electric measuring equipment. Specially treated acupunctures with Nasucon is for sending an acupunctural effect from one place to another via space by someone's will power.

  • PDF

소수력 발전용 고효율 100kW 발전기의 설계해석 및 경제성 분석 (Design Analysis and Economic Analysis of high Efficiency 100kW Generator for Hydro Power System)

  • 지인호;강승진
    • 전기학회논문지
    • /
    • 제65권3호
    • /
    • pp.428-438
    • /
    • 2016
  • This paper shows the design of the 100 kW IPMSG for small hydraulic power generator. The high-efficient generator, method of the dual layer interior permanent magnet was studied to improve the method of the single layer interior permanent magnet, which is mostly used. Analysis of magnet arrangement and cogging torque was done by FEM. According to structure analysis of dual layer interior permanent magnet, the amount of usage of the permanent magnet was reduced and cogging torque was decreased as well. With these successful results, the high-efficient generator design was accomplished. Based on the results of the structure analysis, the test product was designed and manufactured. And the design values and performance outputs were compared and verified with success. Also, the economic feasibility was conducted based on the electric power generated from the test product installed at the site. By the B/C analysis, in case that only SMP was analyzed, B/C ratio was 1.24 at the discount ratio of 5.5%, which considered to be economically feasible. The study is expected to be used for the application of developing large scale high-efficient interior permanent magnet synchronous generator.

수동루프에 의한 송전선로 상불평형 발생에 관한 연구 (A Study on Three-phase Imbalance of a Power Transmission Line due to Installation of a Passive Loop Conductor)

  • 김종형;신명철;최상열
    • 조명전기설비학회논문지
    • /
    • 제17권6호
    • /
    • pp.31-38
    • /
    • 2003
  • 가공송전선로주변 자계저감 기법 중에서 수동루프 방식은 기존 송전철탑에 적은 비용으로 용이하게 적용되어 만족할 만한 저감효과를 제공할 수 있지만 수동루프에 유도되는 전류에 의해 송전손실이 증가될 뿐 아니라 송전선로의 기하학적 비대칭성이 증가됨으로써 상불평형이 증가하게된다. 따라서 본 논문에서는 수동루프 설치에 따른 송전손실과 송전선로 수전단에서의 상불평형을 모의하고자한다. 345[kV]급 수평 상배치 1회선 가공송전선로를 선정하여 수동루프를 송전선로의 선로정수에 포함시킨 비대칭 3상 분포정수 모델로 표현하였으며 이것에 대한 미분방정식을 정의하고 해를 구함으로써 수전단 3상의 전압과 전류를 계산했다. 그 결과로부터 각 상에 따라 전력손실이 다르게 발생하며 수전단에서 정상분이 감소하는 대신에 역상분이 증가함을 확인하였다. 일반적으로 수동루프에 의한 상불평형이 차지하는 비중이 크지는 않지만 수동루프 설치구간과 유도전류의 크기 등에 비례하여 증가하므로 수동루프 도입에 따른 소요비용을 산출하는 과정에서 그에 따른 영향을 포함시켜야 할 것으로 판단된다.

Evaluation of Chromosomal Alteration in Electrical Workers Occupationally Exposed to Low Frequency of Electro Magnetic Field (EMFs) in Coimbatore Population, India

  • Balamuralikrishnan, Balasubramanian;Balachandar, Vellingiri;Kumar, Shanmugam Suresh;Stalin, Nattan;Varsha, Prakash;Devi, Subramaniam Mohana;Arun, Meyyazhagan;Manikantan, Pappuswamy;Venkatesan, Chinnakulandhai;Sasikala, Keshavarao;Dharwadkar, Shahnaz N.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권6호
    • /
    • pp.2961-2966
    • /
    • 2012
  • Extremely low frequency electro magnetic fields (EMFs) have been classified as possibly carcinogenic to humans by the International Agency for Research on Cancer. An increased number of chromosomal alterations in peripheral lymphocytes are correlated with elevated incidence of cancer. The aim of the present study was to assess occupationally induced chromosomal damage in EMF workers exposed to low levels of radiation. We used conventional metaphase chromosome aberration (CA) analysis and the micronucleus (MN) assay as biological indicators of non ionizing radiation exposure. In the present study totally 70 subjects were selected including 50 exposed and 20 controls. Informed written consent was obtained from all participants and the study was performed in accordance with the Declaration of Helsinki and the approval of the local ethical committee. A higher degree of CA and MN was observed in exposed subjects compared to controls, the frequency of CA being significantly enhanced with long years of exposure (P<0.05). Moreover increase in CA and MN with age was noted in both exposed subjects and controls, but was significantly greater in the former. The results of this study demonstrated that a significant induction of cytogenetic damage in peripheral lymphocytes of workers occupationally exposed to EMFs in electric transformer and distribution stations. In conclusion, our findings suggest that EMFs possess genotoxic capability, as measured by CA and MN assays; CA analysis appeared more sensitive than other cytogenetic end-points. It can be concluded that chronic occupational exposure to EMFs may lead to an increased risk of genetic damage among electrical workers.

세포 실험용 다중 주파수 동시 노출 장치 제작 (Fabrication of Multiple-Frequency Exposure System for In Vitro Experiment)

  • 김태홍;서민경;문지연;백정기
    • 한국전자파학회논문지
    • /
    • 제23권2호
    • /
    • pp.213-219
    • /
    • 2012
  • 최근 이동 통신 서비스의 증가로 인해 인류는 다양한 전자파에 동시 노출되어 있다. 그러나 전자파의 인체 영향 연구는 주로 단일 주파수에 대해서 행해졌다. 본 논문에서는 다중 주파수의 전자파를 동시에 노출시킬 수 있는 세포 실험 장치를 제작하였다. 세포 실험 장치는 836.5 MHz 주파수의 CDMA(Code Division Multiple Access) 및 1,950 MHz의 WCDMA(Wideband Code Division Multiple Access) 주파수의 신호를 동시에 발생시킬 수 있도록 광대역 특성을 갖는 radial transmission line 형으로 구성하였다. 변조된 신호는 증폭기, 디지털 감쇄기, RF 결합기를 통하여 원추형 안테나로 전달된다. SAR(Specific Absorption Rate)값은 광학 온도 프로브를 이용하여 petri dish 내 9개 지점에 대하여 3회 측정한 평균값을 이용하여 측정하였다. 측정된 안테나의 반사 손실은 -15dB 이하였고, 단위 입력 전력당 SAR 평균과 표준 편차는 CDMA 주파수에서 $0.105{\pm}0.019$ W/kg, WCDMA 주파수에서 $0.262{\pm}0.055$ W/kg이었다.