• 제목/요약/키워드: Electric and magnetic field(EMF)

검색결과 40건 처리시간 0.026초

송전선로 주변의 3차원 자기장 및 인체 유도 와전류 계산 (ELF 3D Magnetic Field and Eddy Current Calculation of Human Body Around Transmission Lines)

  • 명성호;이동일;신구용;한인수;박종근
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권10호
    • /
    • pp.485-491
    • /
    • 2002
  • Since Wertheimer and Leeper reported possible adverse health effects of magnetic field in 1979, worldwide researches on this issue have been conducted. More recently, the U.S. Congress instructed the NIEHS (National Institute of Environmental Health Sciences), NIH (National Institute of Health) and DOE (Department of Energy) to direct and manage EMF RAPID (Electric and Magnetic Fields Research and Public Information Dissemination) program aimed at providing scientific evidence to clarify the potential for health risks from exposure to extremely low frequency electric and magnetic fields(ELF-EMF). Although they concluded that the scientific evidence suggesting adverse health risks of ELF-EMF is weak, the exposure to ELF-EMF cannot be recognized as entirely safe. Therefore, the purpose of this article is to describe magnetic field 3-D calculation and to evluate eddy current of human body compare to international guide line recognized one of the basic problems. In open boundary problem, Magnetic field using FEM is not advantageous in the point of the division of area and the proposition of the fictitious boundary. Therefore, we induced the analytic equation of magnetic field calculations so but the finite line segment based on Biot-Savarts law Also, Eddy currents induced due to ELF-EMF magnetic field are computed. To calculate induced currents, impedance method is used in this paper, An example model of human head with resolution of 1.27cm is used. In this paper, We evaluate the magnetic field and eddy current of human head around 765 kV transmission lines compare to international guide line.

송전선로 부근과 가전제품의 전자계 측정 (Measurements of Electric and Magnetic Fields in the Vicinity of Transmission Lines and Electric Appliances)

  • 김상범;조성배;이동일;신구용;김정부
    • 한국전자파학회논문지
    • /
    • 제9권5호
    • /
    • pp.687-697
    • /
    • 1998
  • 최근 국내 전력설비에서 발생하는 전자계에 대한 관심이 증가하고 있지만 이에 대한 정확한 자료 파악은 극히 미미한 실정이다. 본고에서는 송전선로에서 발생하는 전계와 자계의 수준을 알아보기 위하여 전국 1537H의 송전 선로를 대상으로 전계와 자계를 측정하였다. 측정 지점의 전계와 자계 최대치들의 중간값은 각각 0.47 kV /m, 11.6 mG 최고 값은 각각 3.16 kV /m, 125 mG로 나타났으며, 전세계의 전자계 관련 권고치나 기준치에 비해 낮은 값임을 알 수 있었다. 아울러 몇 가지 경우에 대하여 가전제품에서 발생하는 자계와 일일 자계 노출량올 측정 하였고 이를 송전선로의 자계 크기와 비교하였다.

  • PDF

초고압 송전선로의 자계크기 해석과 실측 비교 (Analysis and Comparision of Measured and Calculated Value on Magnetic Fields Strength under Transmission Lines)

  • 조성배;이은웅
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권7호
    • /
    • pp.832-838
    • /
    • 1999
  • Recently, there are growing concerns about power frequency electric and magnetic fields coming out from the high voltage transmission lines, because of the wide spread perception of their probable harmful effect on human body. In connection with this trend, this paper describes the electric and magnetic fields measurement result around 154 kV and 345 kV transmission lines, a comparison of measured EMF to calculated one and the correlations between transmission lines currents and measured magnetic fields. Daily maximum and minimum magnetic field quantities under the selected 154 kV and 345 kV transmission lines had been measured for 1 year of 1997 and the average value of magnetic field exposure under the lines were calculated and presented based on the measured data.

  • PDF

345/154KV 전력소 구내의 자계 분포 특성 (Characteristic of Magnetic Fields Distribution in 345/154KV outdoor Substation)

  • 사재원;김성명;홍정표;전형태;한성진;주수원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.97-99
    • /
    • 1997
  • For two decades and more, a lot of research work on the biological effects of EMF (Electromagnetic Field) on human health have been reported. Electric facilities in a typical substation are the main source of magnetic field. This paper presents the measurement and analysis of magnetic field in 345/154KV outdoor substation. The magnetic field depends on the currents which distributed by electric facilities. The result of this paper will be able to be used as basic informations to reduce the level of EMF from the electric utility facilities.

  • PDF

과천 송전선로 전자계 측정 (Measurement of Magnetic and Electric Field from Kwachun Power Transmission Lines)

  • 김덕원;유창용
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.353-356
    • /
    • 1996
  • Early this year the construction of new high voltage power lines have been forced to stop due to the demonstration of residents in Kwa-chun. According to mutual agreement between the residents and Korea Electric Power Corporation, electromagnetic field(EMF) from present power lines was measured and EMF after completion of new power lines was estimated. The results show that EMF near power lines Is relatively low, and EMFnear electric substation is quite high due to the short distance between the power lines and ground. For 4 conduction 345kV line, magnetic field decreases to 3mG at the distance of 50m from the power line.

  • PDF

각종 전기기기 및 장소에서의 전자파 측정 (Electromagnetic Forces Measurement of Various Electric Appliances and Places)

  • 김덕원;류창용;김수찬;윤형로
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 춘계학술대회
    • /
    • pp.179-182
    • /
    • 1995
  • Although air, water, and noise pollutions have been widely recognized, electromagnetic forces(EMF) hazard has been rarely recognized as a pollution and very little studies has been done in this country. Thus, in this study electromagnetic forces radiated by various home appliances, once machines, and communication equipments were measured and so were several places radiating strong EMF such as subway stations and electric substations. Among the home appliances microwave oven senates lots of magnetic field and microwaves, and electric mattress does strong magnetic field. In video game room strong magnetic and considerable electric fields were measured. It was observed strong magnetic field inside of electric powered train and very strong magnetic and electric fields on some platforms. Hand-phone and car-phone radiate very hazardous level of microwaves to brain and that they rapidly come into wide use. In this study data base for various electric machines and places radiating strong EMFs were constructed and could be used for future epidemiological studies.

  • PDF

국내 거주환경에서의 전자기장 노출평가를 위한 Wire code의 타당성에 관한 연구 (Application of a Wire code in Domestic Residential EMF Studies)

  • 탁상우;김현;김록호
    • 한국환경보건학회지
    • /
    • 제26권3호
    • /
    • pp.55-60
    • /
    • 2000
  • Wire codes, introduced by Wertheimer and Leeper, are interesting largely because several case-control studies have reported associations between them and certain types of cancers, including childhood leukemia. This paper is concerned with the reliability of wire codes as a surrogate for residential electric and magnetic field, divided into four categories based on the electrical wiring within 40m of homes. To examine the correlation between spot measurements and wire codes, EMF was measured by using HI-3604 and classified by wire codes. The correlation between long-transformed RMS of magnetic field and wire codes was 0.81. But the correlation between log-transformed RMS of electric field and wire codes was 0.27. The results led us to determine a four category from of the Wertheimer and Leeper code that 1) may be useful in domestic epidemiological studies and 2) is not suitable for electric field exposure. Thus, the critical point of exposure assessment in residential magnetic field is to classify a wire code precisely.

  • PDF

On-Line Electric Vehicle의 EMF 저감을 위한 FCCL 차폐효과 분석 (An Analysis of FCCL Shielding Effect for EMF Attenuation to On-Line Electric Vehicle)

  • 심형욱;김종우;조동호
    • 전기학회논문지
    • /
    • 제63권6호
    • /
    • pp.770-775
    • /
    • 2014
  • According to ICNIRP guidelines for limiting exposure to time-varying electric, magnetic and electromagnetic fields up to 300GHz, magnetic flux density which range from 3Hz to 150kHz are regulated to lower than $6.25{\mu}T$. In order to comply with its standard, OLEV(On-Line Electric Vehicle) have been designed considering EMF(Electro-Magnetic Field) reduction. However, if a current flowing in power line would be bigger for increasing power transfer efficiency, the established shield system no longer acts their role properly. In this paper, therefore, FCCL(Flexible Copper Clad Laminate) is applied to power line and pick-up devices to solve the problems. Though, the FCCL is normally utilized to insulator on circuit board, because of its high heat resistance characteristic, flexibility and thin properties, it makes effectiveness in the shielding device as well. 4 types of FCCL shielding structure are introduced to power line and pick-up devices. From the results, the FCCL which are placed in proposed positions shows maximum EMF reduction compared to the established shielding structure. Henceforth, if OLEV is applied FCCL shielding structure in practice, it will not only be more safe but also step forward to commercialization near future.

A New Method to Estimate the Induced Electric Field in the Human Child Exposed to a 100 kHz-10 MHz Magnetic Field Using Body Size Parameters

  • Park, Young-Min;Song, Hye-Jin;Byun, Jin-Kyu
    • Journal of Magnetics
    • /
    • 제19권2호
    • /
    • pp.174-180
    • /
    • 2014
  • In this paper, a new and simple method is proposed to quickly estimate the induced electric field in the human child exposed to a 100 kHz-10 MHz magnetic field, for the sake of electromagnetic field (EMF) safety assessment. The quasi-static finite-difference time-domain (FDTD) method is used to calculate the induced electric fields in high resolution 3D human child models with various body size parameters, in order to derive the correction factor for the estimation equation. The calculations are repeated for various frequencies and incident angles of the magnetic field. Based on these calculation results, a new and simple estimation equation for the 99th percentile value of the body electric field is derived that depends on the body size parameters, and the incident magnetic field. The estimation errors were equal to or less than 5.1%, for all cases considered.

공진형 무선전력전송 대역의 100kHz~10MHz 자기장에 의한 인체유도전류계산과 전자기장 인체보호기준 분석 (Calculation of Induced Current in the Human Body by Magnetic Field in the 100kHz~10MHz Resonant WPT Frequency Range and Analysis of EMF Guideline)

  • 신한수;송혜진;변진규
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.110-119
    • /
    • 2013
  • As the technologies such as middle-range resonant WPT (wireless power transfer) advance that utilizes medium and low-frequency magnetic field, the importance of safety of such magnetic field is growing. The research on the effect of electromagnetic field on the human body has been mainly done on the GHz range of mobile phones, or 50~60Hz range of electric power systems. However, there has been relatively few works on the 100kHz~10MHz range used in the resonant wireless power transfer. Since there is a difference in the limiting value of magnetic field between widely used ICNIRP EMF guideline and IEEE C95.1 standard, there can be possible confusion when establishing EMF (Electromagnetic Field) standard on the wireless power transfer device in the future. In this paper, the induced current in the human body, which is the basic restriction of the EMF guideline, is calculated using Quasi-static FDTD method when 3D high-resolution human model is exposed to the 100kHz~10MHz magnetic field. Using this result, the feasibility of the magnetic field reference level in the ICNIRP guideline is analyzed.