• Title/Summary/Keyword: Electric Power Take-off

Search Result 40, Processing Time 0.03 seconds

High-Frequency Flyback Transformer Linked PWM Power Conditioner with An Active Switched Capacitor Snubber

  • Mun, Sang-Pil;Kim, Soo-Wook;Joo, Seok-Min;Park, Young-Jun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.7
    • /
    • pp.7-15
    • /
    • 2008
  • A single active capacitor snubber-assisted soft-switching sinewave pulse modulation utility-interactive power conditioner with a three-winding flyback high frequency transformer link and a bidirectional active power switch in its secondary side has been proposed. With the aid of the switched-capacitor quasi-resonant snubber cell, the high frequency switching devices in the primary side of the proposed DC-to-AC sinewave power inverter can be turned-off with ZVS commutation. In addition to this, the proposed power conditioner in the DCM can effectively take the advantages of ZCS turn-on commutation. Its output port is connected directly to the utility AC power source grid. At the end, the prototype of the proposed HF-UPC is built and tested in experiment. Its power conversion conditioning and processing circuit with a high frequency flyback transformer link is verified and the output sinewave current is qualified in accordance with the power quality guidelines of the utility AC interactive power systems.

Conceptual design and sensitivity analysis of a tilt + stopped rotor type eVTOL using motor weight estimation formula and iterative design (모터중량 추정식과 반복 설계를 통한 틸트+정지로터형 eVTOL 개념설계 및 민감도 분석)

  • Ju-heon Lee;Taejong Kim;Seo-yoon Jang;Hui-su Jo;Ho-Yon Hwang
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.1
    • /
    • pp.77-95
    • /
    • 2023
  • In this study, the conceptual design of a tilt + stopped rotor type electric vertical take-off and landing (eVTOL) aircraft was performed using design iteration. Based on Hyundai Motor's S-A1, the mission profile was defined using the concept of urban air mobility (UAM), and configuration design and aerodynamic analysis were performed using OpenVSP and XFLR5 software. After estimating the required power for the designed eVTOL, the required performance of the battery and the maximum take-off weight (MTOW) were calculated. . It was iteratively calculated using Microsoft Excel and Visual Basic Application, and a new electric motor weight estimation formula was derived. Also, the sensitivity analyses of each design variables of an eVTOL was performed using the automated program.

A study on design and modeling of a Wave Energy Converter (파력발전기의 에너지 회생을 위한 연구)

  • Yoon, JongIl;Ahn, KyongKwan;Dinh, Quang Truong;Hoang, Huu Tien
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.167.2-167.2
    • /
    • 2011
  • Motions in nature, for example ocean wave, has been playing a significant role for generating electricity production in our modern life. This paper presents an innovative approach for electric power conversion of the vast ocean wave energy. Here, a floating-buoy wave energy converter (WEC) using hydrostatic transmission (HST), which is shortened as HSTWEC, is proposed and designed to enhance the wave energy harvesting task during all wave fluctuations. In this HSTWEC structure, the power take-off system (PTO) is a combination of the designed HST circuit and an electric generator to convert mechanical energy generated by ocean wave into electrical energy. Several design concepts of the HSTWEC have been considered in this study for an adequate investigation. Modeling and simulations using MATLAB/Simulink and AMESim are then carried out to evaluate these design concepts to find out the best solution. In addition, an adaptive controller is designed for improving the HSTWEC performance. The effectiveness of the proposed HSTWEC control system is finally proved by numerical simulations.

  • PDF

An Explicit Column Generation Algorithm for the Profit Based Unit Commitment Problem in Electric Power Industry (전력산업에서의 Profit-Based Unit Commitment Problem 최적화를 위한 명시적 열생성 알고리즘)

  • Lee, Kyung-Sik;Song, Sang-Hwa
    • IE interfaces
    • /
    • v.20 no.2
    • /
    • pp.186-194
    • /
    • 2007
  • Recent deregulation of Korean electricity industry has made each power generation company pay more attention to maximizing its own profit instead of minimizing the overall system operation cost while guaranteeing system security. Electricity power generation problem is typically defined as the problem of determining both the on and off status and the power generation level of each generator under the given fuel constraints, which has been known as Profit-Based Unit Commitment (PBUC) problem. To solve the PBUC problem, the previous research mostly focused on devising Lagrangian Relaxation (LR) based heuristic algorithms due to the complexity of the problem and the nonlinearity of constraints and objectives. However, these heuristic approaches have been reported as less practical in real world applications since the computational run time is usually quite high and it may take a while to implement the devised heuristic algorithms as software applications. Especially when considering long-term planning problem which spans at least one year, the complexity becomes higher. Therefore, this paper proposes an explicit column generation algorithm using power generation patterns and the proposed algorithm is successfully applied to a Korean power generation company. The proposed scheme has a robust structure so that it is expected to extend general PBUC problems.

Latching Control Technology for Improvement of Extracted Power from Wave Energy Converter (파력발전기 추출파워 향상을 위한 래칭 제어기법)

  • Cho, Il Hyoung
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.4
    • /
    • pp.282-290
    • /
    • 2015
  • In this study, a latching control technology, proposed by Sheng et al.(2015), was applied in order to maximize the extraction efficiency of WEC (Wave Energy Converter), which is the heaving buoy coupled with linear electric generator. The latching control is the phase-control technique for improving the wave energy conversion with appropriate latching duration of keeping the buoy fixed. From the time-domain analysis in regular waves, the latching control technology can significantly improve the heave velocity and extracted power, even though the resonance condition is not satisfied. By using the latching control technology, the draft of buoy as well as the required PTO damping force can be significantly reduced along with increased extracted power, which is a big advantage in manufacturing the WEC.

Development of a Multi-Absorbing Wave Energy Converter using Pressure Coupling Principle (압력커플링을 이용한 다수개의 부표를 가진 파력발전기 개발)

  • Do, H.T.;Nguyen, M.T.;Phan, C.B.;Lee, S.Y.;Park, H.G.;Ahn, K.K.
    • Journal of Drive and Control
    • /
    • v.11 no.3
    • /
    • pp.31-40
    • /
    • 2014
  • This paper proposes a multi absorbing wave energy converter design, in which a hydrostatic transmission is used to transfer wave energy to electric energy. The most important feature of this system is its combination of the pressure coupling principle with the use of a hydraulic accumulator to eliminate the effects of wave power fluctuation; this maintains a constant speed of the hydraulic motor. Tilt motion of a floating buoy was employed as the power take-off mechanism. Furthermore, a PID controller was designed to carry out the speed control of the hydraulic motor. The design offers some advantages such as extending the life of the hydraulic components, increasing the amount of energy harvested, and stabilizing the output speed.

Experimental study of wave energy extraction by a dual-buoy heaving system

  • Kim, J.;Koh, H.J.;Cho, I.H.;Kim, M.H.;Kweon, H.M.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.9 no.1
    • /
    • pp.25-34
    • /
    • 2017
  • The concentric dual-buoy Wave Energy Converter (WEC), which consists of external buoy (hallow-cylinder) with toroidal appendage and cylindrical internal buoy within the moon-pool is suggested in this research and its performance in various wave conditions is studied. The Linear Electric Generator (LEG), consisting of a permanent magnet and coils, is used as a direct Power Take-Off (PTO) system. To maximize the electrical energy extracted from the PTO system, the relative heave motions between the dual buoys must be highly amplified by the multiple resonance phenomena of dual-buoy and internal-fluid motions. The high-performance range can be widened by distributing those natural frequencies with respect to the peak frequency of the wave spectrum. The performance of the newly developed dual-buoy WEC was measured throughout the systematic 1:5.95-model test in regular and irregular waves conducted in a wave tank at Seoul National University. The model-test results are also validated by an independently developed numerical method.

Test and Evaluation of the Propeller Developed for a Multi-copter with the Take-off Weight of 25 kg (이륙 중량 25 kg급 멀티콥터용 프로펠러 시험 평가)

  • Kang, Hee Jung;Kim, Taejoo;Wee, Seong-Yong
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.4
    • /
    • pp.26-34
    • /
    • 2018
  • Structural static test and the performance test were conducted to determine whether the propeller developed for a multi-copter with the take-off weight of 25 kg satisfies the design requirement. The result of the structural test revealed that the propeller had a safety margin of 3 or more as the ultimate load and requirement load did not cause the specimen breakage. In the performance test, the propeller generated the hover thrust and maximum thrust of design requirement, and hover efficiency in the operating thrust range was greater than 0.73. Maximum hover efficiency increased by more than 3% compared to the reference propeller and electric power consumption decreased by more than 4% in the operating range. The propeller was found to be successfully developed based on the satisfaction rate of the structural strength requirement and the performance requirement.

Conceptual Design and Aerodynamic Analysis of Double-Seater Tilt-rotor Type PAV (2인승 틸트로터형 PAV 개념설계 및 공력해석)

  • Cho, Yoon-Sung;Kim, Sung-Ji;Baek, Su-Been;Kim, Yeong-Chae;Bae, Geun-Hak;Cho, Eun-Byeol;Yu, Ji-Soo;Hong, Young-Hun
    • Journal of Advanced Navigation Technology
    • /
    • v.26 no.3
    • /
    • pp.144-160
    • /
    • 2022
  • Research on urban air mobility (UAM) is being actively conducted as a method of next-generation transportation. eVTOL, an airplane to be used for urban air mobility, is classified into a complex type, a tilt rotor type, a tilt wing type, a tilt duct fan type, and a multicopter type according to the propulsion method. In this study, conceptual design was performed for the next generation eVTOL of the new tilt rotor type in accordance with the existing design requirements. The aerodynamic analysis programs of OpenVSP and XFLR5 were used to perform aerodynamic analysis. The power required for each flight mission stage was calculated, the battery and motor were selected accordingly, and MTOW (Maximum Take-Off Weight) was predicted by estimating the weight of each component.

Application of Secondary Control Hydrostatic Transmission in A Multi-Point Absorbing Wave Energy Converter (다수의 가동물체형 파력발전기에 있어서의 2차측 제어 정유압변속기 응용)

  • Do, H.T.;Ahn, K.K.
    • Journal of Drive and Control
    • /
    • v.11 no.1
    • /
    • pp.1-7
    • /
    • 2014
  • This paper presents a novel concept of wave energy converter for electric generation from the ocean wave energy. In this paper, a Multi-Point Absorbing Wave Energy Converter, shortened as MPAWEC by using Secondary Control Hydrostatic Transmission (SCHST) was proposed. The power take-off (PTO) system in the proposed MPAWEC includes multi heaving buoys to drive hydraulic pumps placed at different points. The application of SCHST in MPAWEC gives some advantages, such as longevity of hydraulic components; more energy is harvested; the variation of the pressure in the accumulator limited; therefore the accumulator volume is reduced and the output speed is more stable, etc. A PID controller was designed for speed control of the hydraulic motor. The simulation results indicated that the speed of the generator was ensured with the relative error as 0.67%; the efficiency of the proposed system was 71.4%.