• Title/Summary/Keyword: Electric Power Service

Search Result 380, Processing Time 0.028 seconds

Improving QoS using Cellular-IP/PRC in Hospital Wireless Network (병원 무선망에서 Cellular-IP/PRC에 의한 QoS 개선)

  • Suk, Kyung Hyu;Kim, Sung-Hong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.3 no.3
    • /
    • pp.188-194
    • /
    • 2008
  • In this paper, we propose for improving QoS in Hospital wireless network using Cellular-IP/PRC(Paging Route Cache) with Paging Cache and Route Cache in Cellular-IP and propose for performance of realtime and non-real time handoff service using Handoff state machine Paging Route Cache. Although the Cellular-IP/PRC technology is devised for mobile internet communication, it has its vulnerability in frequent handoff environment. This handoff state machine using differentiated handoff improves quality of services in Cellular-IP/PRC Suggested algorithm shows better performance than existing technology in wireless mobile internet communication environment. When speech quality is secured considering increment of interference to receive in case of suppose that proposed acceptance method grooves base radio station capacity of transfer node is plenty, and moat of contiguity cell transfer node was accepted at groove base radio station with a blow, groove base radio station new trench lake acceptance method based on transmission of a message electric power estimate of transfer node be. Do it so that may apply composing PC(Paging Cache) and RC(Routing Cache) that was used to manage paging and router in radio Internet network in integral management and all nodes as one PRC(Paging Router Cache), and add hand off state machine in transfer node so that can manage hand off of transfer node and Roaming state efficiently, and studies so that achieve connection function at node. Analyze benevolent person who influence on telephone traffic in system environment and forecasts each link currency rank and imbalance degree, forecast most close and important lake interception probability and lake falling off probability, GoS(Grade of Service), efficiency of cell capacity in QoS because applies algorithm proposing based on algorithm use gun send-receive electric power that judge by looking downward link whether currency book was limited and accepts or intercept lake and handles and displays QoS performance improvement.

  • PDF

Proposal Protection Algorithm of Dendritic Lithium for Battery Second Use ESS (재사용 ESS를 위한 리튬 배터리 덴드라이트 보호 알고리즘 제안)

  • Song, Jung-Yong;Huh, Chang-Su
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.6
    • /
    • pp.422-426
    • /
    • 2018
  • The lithium-ion battery pack of an electric vehicle (EV) deserves to be considered for an alternative use within smart-grid infrastructure. Despite the long automotive service life, EV batteries retain over 70~80% of their initial capacity. These battery packs must be managed for their reliability and safety. Therefore, a battery management system (BMS) should use specific algorithms to measure and estimate the status of the battery. Most importantly, the BMS of a grid-connected energy storage system (ESS) must ensure that the lithium-ion battery does not catch fire or explode due to an internal short from uncontrolled dendrite growth. In other words, the BMS of a lithium-ion battery pack should be capable of detecting the battery's status based on the electrochemical reaction continuously until the end of the battery's lifespan. In this paper, we propose a new protection algorithm for a dendritic lithium battery. The proposed algorithm has applied a parameter from battery pack aging results and has control power managing.

Charging-Discharging Behavior and Performance of AGM Lead Acid Battery/EDLC Module for x-HEV (x-HEV용 AGM 연축전지/EDLC 통합모듈의 성능 및 충방전 거동)

  • Kim, Sung Joon;Seo, Sung Won;An, Sin Young;Kim, Bong-Gu;Son, Jeong Hun;Jung, Yeon Gil
    • Korean Journal of Materials Research
    • /
    • v.31 no.2
    • /
    • pp.84-91
    • /
    • 2021
  • To cope with automobile exhaust gas regulations, ISG and charging control systems are applied to HEV vehicles for the purpose of improving fuel economy. These systems require quick charge-discharge performance of high current. Therefore, a Module of the AGM battery with high energy density and EDLC(Electric Double Layer Capacitor) with high power density are constructed to study the charging and discharging behavior. In CCA, which evaluates the starting performance at -18 ℃ & 30 ℃ with high current, EDLC contributed for about 8 sec at the beginning. At 0 ℃ CA (Charge Acceptance), the initial Charging current of the AGM/EDLC Module, is twice that of the AGM lead acid battery. To play the role of EDLC during high-current rapid charging and discharging, the condition of the AGM lead-acid battery is optimally maintained. As a result of a Standard of Battery Association of Japan (SBA) S0101 test, the service life of the Module of the AGM Lead Acid Battery/EDLC is found to improve by 2 times compared to that of the AGM Lead Acid Battery.

A Study of the Sustainable Operation Technologies in the Power Plant Facilities (발전 설비 지속 가능 운영 기술 연구)

  • Lee, Chang Yeol;Park, Gil Joo;Kim, Twehwan;Gu, Yeong Hyeon;Lee, Sung-iI
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.4
    • /
    • pp.842-848
    • /
    • 2020
  • Purpose: It is important to operate safely and economically in obsolescent power plant facilities. Economical operation is related in the balance of the supply and demand. Safety operation predicts the possible risks in the facilities and then, takes measures to the facilities. For the monitoring of the power plant facilities, we needs several kinds of the sensing system. From the sensors data, we can predict the possible risk. Method: We installed the acoustic, vibration, electric and smoke sensors in the power plant facilities. Using the data, we developed 3 kinds of prediction models, such as, demand prediction, plant engine abnormal prediction model, and risk prediction model. Results: Accuracy of the demand prediction model is over 90%. The other models make a stable operation of the system. Conclusion: For the sustainable operation of the obsolescent power plant, we developed 3 kinds of AI prediction models. The model apply to JB company's power plant facilities.

Seismic response evaluation of 154 kV transformer porcelain bushing by shaking table tests

  • Chun, Nakhyun;Jeon, Bubgyu;Kim, Sungwan;Chang, Sungjin;Son, Suwon
    • Structural Engineering and Mechanics
    • /
    • v.84 no.2
    • /
    • pp.155-165
    • /
    • 2022
  • The use of electricity and communication between electronic devices is increasing daily, which makes the stability of electrical power supply vital. Since the 1990s, large earthquakes have occurred frequently causing considerable direct damage to electrical power facilities as well as secondary damage, such as difficulty in restoring functions due to the interruption of electric power supply. Therefore, it is very important to establish measures to protect electrical power facilities, such as transformers and switchboards, from earthquakes. In this study, a 154 kV transformer whose service life had expired was installed on the base fabricated by simulating the field conditions and conducting the shaking table tests. The dynamic characteristics and seismic behavior of the 154 kV transformer were analyzed through the resonance frequency search test and seismic simulation test that considers the front, rear, left, and right directions. Since the purpose of this study is to analyze the acceleration amplification in the bushing due to the acceleration amplification, the experimental results were analyzed focusing on the acceleration response and the converted acceleration amplification ratio rather than the failure due to the displacement response of the transformer. The seismic force amplification at the transformer bushing was evaluated by simulating the characteristics of electrical power facilities in South Korea, and compared with the IEC TS 61463 acceleration amplification factor. Finally, the amplification factor at zero period acceleration (ZPA) modified for each return period was summarized. The results of this study can be used as data to define the amplification factor at ZPA of the transformer bushing, simulating the characteristics of electrical power facilities in Korea.

Development of Algorithm and Program for the Ground Fault Detection in Ungrounded Distribution Power System (비접지 배전계통 지락고장 검출 알고리즘 및 프로그램 개발)

  • Park, So-Young;Shin, Chang-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.10
    • /
    • pp.2619-2627
    • /
    • 2009
  • The ground fault is occupying 70% among the total number of faults in ungrounded distribution power system. When the ground fault occurs in ungrounded system, the fault current is so small that it is hard to detect. But fault handling is very important because to continue power supply during fault conditions may cause the fault spreading and the distribution device in trouble. This paper presents the fault line detection method by using GPT signal detecting zero sequence voltage, and the fault section detection method by detecting whether GPT signal is disappeared or not during shifting normally open switch, which is connecting switch between distribution lines with open state in order to restore the outage area under emergency situation, and during isolating each section one by one which belongs to the fault line. This method is efficient because there is no whole power interruption during the fault section detection, and it is possible to perform both the fault section detection and the service restoration for the outage area at the same time, and it can apply to various distribution system configuration. Program for the fault restoration was developed applying proposed method, and it has been validated by applying to the pilot project of distribution automation system in Vietnam which has the ungrounded distribution system.

Analysis of Harmonic Effects on Substation Power System and its Countermeasure (지하철 전력계통의 고조파 영향 분석 및 그 대책에 관한 연구)

  • Song, Jin-Ho;Hwang, Yu-Mo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.4
    • /
    • pp.210-220
    • /
    • 2002
  • We analysised the effect of harmonics on electric machines of substation power system barred on quantitatively measured harmonics and proposed the methods for prevention of harmonics through checking on transformer, rectifier and cable's capacities against harmonics with reference to KEPCO's electricity service standard. In order to analysis harmoninics of silicon rectifier that is power source in DC substation, computer simulations for a substation with TR of high voltage distribution switchboard are performed. Simulation results show that the total harmonic distortion factor becomes smaller for TR primary and receiving points in order rather than silicon rectifier which is harmonic generation source so that the harmonics generated frets each rectifier are outflowed to power supply and high voltage distribution switchboard The result of higher distortion factors of voltage and current for rectifier with 100% load than those with 50 % and 30% indicates that the waveform of voltage and current for the real substation power system at the office-going and the closing hours with heavy loads might be more distorted. As proposed methods for harmonic reduction, the conventional 6 pulse-type for substation is required to be replaced by 12 pulse-type for reduction of 5th and 7th harmonics. The active filter rather than the passive filter is more effective due to severe variance of rectifier loads, but the high cost is price to be paid. In view of installation area and costs, the use of 12 pulse-type transformer is desirable and then the parallel transformer and the rectifier within the substation must be replaced at the same time. Other substations with parallel feeder can use 6 pulse-type transformer.

Outage Rate Calculating Method of Energy Storage System for the Application on Power System Operation (전력계통 운영적용을 위한 전기저장장치 고장률 산정방안)

  • Song, Seung-Heon;Choi, Woo-Yeong;Kook, Kyung-Soo
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.188-192
    • /
    • 2019
  • As the contribution of the Energy Storage System (ESS) on the power system operations has increased, it is required to secure the reliability on the capacity of ESS and this needs to consider the outage rate in calculating the available capacity of ESS. However, the existing method of calculating the outage rate does not consider the configuration of ESS and this does not accurately calculate the available capacity of ESS. For this, this paper analyzes the structural characteristics of ESS in Korean power system and proposes a method to calculate the outage rate of ESS. Through the study cases adopting the Korea Electric Power Corporation (KEPCO) ESS for providing the frequency response service, the effectiveness of the proposed method verified.

Design of Minimal Postal Transportation Path using Steiner Tree (Steiner Tree 이론을 이용한 최적 우편물 운송망 구축)

  • Lyu, Woong-Gyu;Lee, Sang-Joong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.183-186
    • /
    • 2007
  • Faster, safer and cheaper mailing of the postal matter is essential for surviving in the competitive market of home-delivery service. The Steiner tree connects points minimally in geometrical way and has been used in the distribution system optimization and optimal routing of the transmission lines of the electric power system. This paper proposes a method to select the optimal location of mail distribution center that minimally connect the local mail center of some major cities using the Steiner tree theorem.

  • PDF

Building IEC 61850 SCADA system based on TETRA (TETRA 기반 IEC 61850 SCADA 시스템 구축)

  • Song, Byung-Kwen;Jeong, Tae-Ui
    • Journal of IKEEE
    • /
    • v.13 no.3
    • /
    • pp.87-94
    • /
    • 2009
  • TETRA(TErrestrial Trunked RAdio) is the wireless communication system generally adopted to public network and backbone network, as the technology of Trunked Radio System specified by ETSI(European Telecommunications Standards Institute) and currently adopted to the Electric Power IT Backbone Network in Korea. IEC 61850 is the protocol proposed for SAS(Substation Automation System) of SCADA(Supervisory Control And Data Acquisition) system. In this paper, IEC 61850 Server and Client simulator are used based on Linux operating system. The multi-functional gateway, which transforms the communication based on TCP/IP between IEC 61850 Server Simulator and Client Simulator to the one based on TETRA Packet Data Service, is developed such that IEC 61850 SCADA system is constructed based on TETRA.

  • PDF