100 Kw급 항공용 보조동력장치(APU) 개발 (Development of 100 Kw Power Class Airborne Auxiliary Power Unit)

  • 양수석;이대성;김승우
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.291-300
    • /
    • 1999
  • Currently under development is an airborne auxiliary power unit with 100 Kw equivalent power, which is composed of a centrifugal compressor, a reverse annular combustor, and a radial turbine. Air-foil bearings are used in this power unit to eliminate the oil supplying system, which can reduce the system complexity and weight. The high speed generator is adopted as an electric power generation and engine starting system, which can also eliminate the reduction gear system. Not only electric power but also pneumatic power is provided by bleeding the compressed air This power unit is aimed for the multi-purpose use such as a primary power unit In the army weapon system, an auxiliary power and environmental control unit in a next-generation tank, and a smoke generating unit.

  • PDF

철도차량의 9 kHz~150 kHz 대역에서의 RFI 노이즈 저감연구 (RFI Noise Reduction of the Electric Train in the Frequency Range of 9 kHz to 150 kHz)

  • 강용삼;이종우
    • 전기학회논문지
    • /
    • 제63권1호
    • /
    • pp.179-183
    • /
    • 2014
  • An electric railway is unique system that electric trains consumed huge electric power are travelled and is much interested with EMC. There were several problems exceeding the standard in the frequency range of 9 kHz to 150 kHz because the radiation noises were moved the higher frequency range according to developing the power electronic technology. It is studied the analytic simulation for reducing noise level in terms of cables of the electric train and is experimentally approved the reduction effectiveness.

배기계의 배기압 감응형 제어 머플러 개발에 관한 실험적 연구 (An Experimental Study on the Development of Muffler with Cotroller Sensing Exhaust-gas Pressure in Exhaust System)

  • 이해철;석동현;이준서;차경옥
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.892-898
    • /
    • 2000
  • This study is on the development of a new muffler composed of a valve system using an elasticity or spring. The valve system using the elasticity of spring is set along the exhaust-gas flow and designed to work itself alone the driving condition of a engine. By that reason the engine capacity is so enlarged that a muffler with controller sensing exhaust-gas pressure is able to be satisfied to noise reduction and- power enlargement more than conventional muffler. The purpose of this study is to develope the new muffler which has more noise reduction and power enlargement than conventional muffler and electric-control muffler.

  • PDF

전기자동차 소음저감을 위한 구동모터 하우징의 동특성 평가 (Identifying Dynamic Characteristics of the Traction Motor Housing For the Noise reduction of the Electric vehicle)

  • 박종찬;박승용;조현규;박윤수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.818-823
    • /
    • 2012
  • Assessment of the dynamics properties, like damping, dynamic stiffness and resonance sharpness is essential for the development of a robust system, specifically for the reduction of a traction motor noise. A practical method for identifying dynamic characteristics of a traction motor hosing for an electric vehicle is proposed. Assembling using interference fit of the components of the motor is attributed to the main cause of strong nonlinearity. It is well known that nonlinearity of a structure makes it difficult to assess damping properties or dynamic characteristics of the system. This research presents a practical damping or dynamic stiffness identifying procedures for a nonlinear system according to the boundary condition between assembled components. Based on the simple idea that impact forces of modal tests are highly affected on the condition of the hammer tip, Auto Power Spectrum of the impact forces are used to assess the assembling condition and dynamic characteristics of the system, especially, damping of the system.

  • PDF

배전자동화시스템 적용을 위한 경제성 평가 (Economic Evaluation far the Application of the Distribution Automation System)

  • 홍순학;하복남;김호용;정경희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.36-38
    • /
    • 1993
  • This study considers the economic aspect of the distribution automation system, which is the decision-making criteria of the electric utilities for the investment. The feeder automation candidate region is divided into two types of the urban and the rural. The total investment cost of the feeder automation for each type is estimated. The annual cost, is also estimated, by finding the fixed charge rate. To compare the annual cost and the economic effect cost, for the investment decision-making, the costs are quantitatively estimated on the following effects : the manpower replacement, the outage cost saving, the main transformer utilization improvement, the feeder utilization improvement, and the line loss reduction.

  • PDF

Priority Rankings of the System Modifications to Reduce Core Damage Frequency of Wolsong NPP Units 2/3/4

  • Kwon, Jong-Jooh;Kim, Myung-Ki;Seo, Mi-Ro;Hong, Sung-Yull
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1998년도 춘계학술발표회논문집(1)
    • /
    • pp.899-905
    • /
    • 1998
  • The analysis priority makings the recommendation to reduce the total core damage frequency (CDF) of Wolsong nuclear Power Plant nits 2/3/4 was Performed in this paper. In order to derive the recommendation, the sensitivity analysis of CDF on which major contributors effect m performed based on the accident quantification results during Level 1 Probabilistic safety assessment (PSA). Priorities were ranked in tile way that compares the CDF reduction rate with efforts required to implement those recommendations using risk matrix

  • PDF

대기전력 저감형 LED 센서 조명시스템의 개발 (Development of a Sensor-Based LED Lighting System with Low Standby Power)

  • 김진근;강문성
    • 전기학회논문지P
    • /
    • 제61권1호
    • /
    • pp.18-22
    • /
    • 2012
  • In this paper, we propose a sensor-based LED lighting system that can significantly reduce standby powers. The proposed LED lighting system has the more advanced power circuit and control mechanism compared to existing one. The whole power circuit consists of two subcircuits. One is designed to apply electric powers to controller, PIR(Pyroelectric Infrared Ray) sensor and CdS, and the other one is designed to apply electric powers to LED module. Such a power circuit configuration makes the standby powers reduction of LED lighting system possible. From the experimental results, we confirmed that the standby powers saving performance of the developed power circuit is superior to that of the conventional one.

소형 전기차량용 구배반응 무단변속기 개발 (The Development of Gradient Response CVT for a Small Size Electric Vehicle)

  • 김규성;권영웅
    • 동력기계공학회지
    • /
    • 제19권6호
    • /
    • pp.33-38
    • /
    • 2015
  • In this study new CVT(Continuously Variable Transmission) system which is adaptable to a small size electric vehicle is proposed available to gradient response CVT. New pulleys consist of springs adapted driving pulley and driven pulley. At the moment a small electric vehicle drive a slope, new system respond to a gradient as overcoming tensional force of springs. We made prototype of gradient response CVT to test parts performance and travelling performance test. As a result of test, belt pitch diameter varied for high torque direction at the gradient. In the flat travelling, acceleration travelling and gradient travelling performance test, the small electric vehicle with gradient response CVT get improved perfomance than the small electric vehicle with reduction gear.

Evaluation of a Prototype SF6 Purification System for Commercialization

  • Seo, Hai-Kyung;Lee, Jeong Eun;Kim, Kwang Sin;Kim, Kyeongsook
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권1호
    • /
    • pp.53-58
    • /
    • 2020
  • Korea Electric Power Corporation (KEPCO) uses large amount of SF6, one of the potent greenhouse gases, in electric equipment for electrical insulation. KEPCO is developing SF6 recovery and purification technology to minimize the release of SF6 into the environment, to secure certified emission reduction, and to save purchase cost of new SF6 by reusing the refined SF6. A prototype SF6 purification system using cryogenic solidification technology has been built in demonstration scale. To evaluate the feasibility of the commercialization, the system has been operated to purify large amount of used SF6 in a long-term operation and the performance has been economically evaluated. The system was stable enough for commercial operation such that it was able to purify 5.4 tons of used SF6 from power transmission equipment in 2-month operation. Over 99% of the SF6 was recovered from the used gas and the purity of the purified gas was over 99.7 vol%. The operation cost, which is the cost of refrigerant (liquid nitrogen), electricity and labor, per kilogram of purified SF6 was 6,526 KRW. Considering the price of new SF6 in Korea is about 15,000 KRW per kilogram this year, about 56% of the purchase cost can be saved.

낙뢰로부터 전력설비 보호를 위한 한전의 절연설계 기준 (Insulation Design Standards for Protection of Power System against Lightning in Korea Electric Power Corporation)

  • 우정욱;문재덕
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권12호
    • /
    • pp.555-560
    • /
    • 2006
  • As it has been reported that more than 60% of transmission line faults occurs due to lightning strokes, lighting is one of concerned issues in electric power utility company. Most of transmission line is double circuit in Korea. Double circuit outages account for 33.7 percent of total lightning faults from 1996 to 2004. Even though transmission fault might be cleared shortly by protective system, it could deteriorate the power quality accompanied with sag or flicker. Moreover, double circuit fault may lead to more aggravated situation, for instance, blackout. To Protect transmission lines from lightning stroke, reduction of tower footing resistance, multiple ground wires and unbalanced insulation in double circuit lines have been adopted. In this paper, we would like to introduce insulation design standards for lightning protection of Korea Electric Power Corporation.