• Title/Summary/Keyword: Electric Generator

Search Result 924, Processing Time 0.036 seconds

Characteristics of Lightning Overvoltages Coming in Low-Voltage Power Distribution Systems

  • Lee, Bok-Hee;Lee, Dong-Moon;Lee, Su-Bong;Jeong, Dong-Cheol;Lee, Jae-Bok;Myung, Sung-Ho
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.3
    • /
    • pp.91-98
    • /
    • 2003
  • The importance of improving the quality of electric power is being strongly raised, owing to an increasing use of sensitive and small-sized electronic devices and systems. The transient over-voltages on low-voltage power distribution systems are induced by direct or indirect lightning return strokes. These can cause damage and/or malfunction of the utility systems for home automation, office automation, factory automation, medical automation, etc. The behaviors of lightning overvoltages transferred through the transformer to the low-voltage distribution systems using a Marx generator were experimentally investigated. Furthermore, the coupling mechanisms of lightning overvoltages transferred to the low-voltage systems were clearly illustrated through a theoretical simulation using a Pspice program. The overvoltages in low-voltage ac power systems are rarely limited by the application of the surge arrester to the primary side of the distribution transformer. A superior surge protection scheme is to install surge protection devices at the service entrance switchboard and/or at the load devices in TN power systems.

Design of Permanent Magnet Type Wind Power Generators for Cogging Torque Reduction with Optimum Pole Arc Pitch Ratio (코깅토크 저감을 위한 최적 극호비를 갖는 영구자석형 풍력발전기의 설계)

  • Jang, Seok-Myeong;Kim, Jin-Soon;Ko, Kyoung-Jin;Choi, Jang-Young;Yoon, Gi-Gab
    • Proceedings of the KIEE Conference
    • /
    • 2009.04b
    • /
    • pp.38-40
    • /
    • 2009
  • In order to achieve a gearless construction of the wind energy conversion system(WECS), a low-speed generator should be used. Of the various candidate machine types, radial-field, multi-pole, permanent magnet, synchronous machines may be used for low-speed applications. So, this paper deals with the design of direct-coupled, multi-pole radial field machines with permanent magnet(PM) excitation for wind power applications for cogging torque reduction through the determination of optimum pole arc/pitch ratio. On the basis of an equivalent magnetic circuit method(EMCM) and a space harmonic method(SHM), an initial design is performed considering restricted conditions. And then, a detailed design is made using a non-linear finite element analyses(FEA). Finally, test results concerning generating characteristics are given to confirm the validation of the design.

  • PDF

Market Power in the Korea Wholesale Electricity Market (우리나라 전력시장에서의 시장지배력 행사)

  • Kim, Hyun-Shil;Ahn, Nam-Sung
    • Korean System Dynamics Review
    • /
    • v.6 no.1
    • /
    • pp.99-123
    • /
    • 2005
  • Although the generation market is competitive, the power market is easily exercised the market power by one generator due to its special futures such as a limited supplier, large investment cost, transmission constraints and loss. Specially, as Korea Electric industry restructuring is similar US competitive wholesale electricity market structure which discovered the several evidences of market power abuse, when restructuring is completed the possibility that market power will be exercised is big. Market power interferes with market competitions and efficiency of system. The goal of this study is to investigate the market price effects of the potential market power and the proposed market power mitigation strategy in Korean market using the forecasting wholesale electricity market model. This modeling is developed based on the system dynamics approach. it can analyze the dynamic behaviors of wholesale prices in Korean market. And then it is expanded to include the effect of market condition changed by 'strategic behavior' and 'real time pricing.' This model can generate the overall insights regarding the dynamic impact of output withholding by old gas fire power plant bon as a marginal plant in Korean market at the macro level. Also it will give the energy planner the opportunity to create different scenarios for the future for deregulated wholesales market in Korea.

  • PDF

An Explicit Column Generation Algorithm for the Profit Based Unit Commitment Problem in Electric Power Industry (전력산업에서의 Profit-Based Unit Commitment Problem 최적화를 위한 명시적 열생성 알고리즘)

  • Lee, Kyung-Sik;Song, Sang-Hwa
    • IE interfaces
    • /
    • v.20 no.2
    • /
    • pp.186-194
    • /
    • 2007
  • Recent deregulation of Korean electricity industry has made each power generation company pay more attention to maximizing its own profit instead of minimizing the overall system operation cost while guaranteeing system security. Electricity power generation problem is typically defined as the problem of determining both the on and off status and the power generation level of each generator under the given fuel constraints, which has been known as Profit-Based Unit Commitment (PBUC) problem. To solve the PBUC problem, the previous research mostly focused on devising Lagrangian Relaxation (LR) based heuristic algorithms due to the complexity of the problem and the nonlinearity of constraints and objectives. However, these heuristic approaches have been reported as less practical in real world applications since the computational run time is usually quite high and it may take a while to implement the devised heuristic algorithms as software applications. Especially when considering long-term planning problem which spans at least one year, the complexity becomes higher. Therefore, this paper proposes an explicit column generation algorithm using power generation patterns and the proposed algorithm is successfully applied to a Korean power generation company. The proposed scheme has a robust structure so that it is expected to extend general PBUC problems.

Virtual Flux and Positive-Sequence Power Based Control of Grid-Interfaced Converters Against Unbalanced and Distorted Grid Conditions

  • Tao, Yukun;Tang, Wenhu
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1265-1274
    • /
    • 2018
  • This paper proposes a virtual flux (VF) and positive-sequence power based control strategy to improve the performance of grid-interfaced three-phase voltage source converters against unbalanced and distorted grid conditions. By using a second-order generalized integrator (SOGI) based VF observer, the proposed strategy achieves an AC voltage sensorless and grid frequency adaptive control. Aiming to realize a balanced sinusoidal line current operation, the fundamental positive-sequence component based instantaneous power is utilized as the control variable. Moreover, the fundamental negative-sequence VF feedforward and the harmonic attenuation ability of a sequence component generator are employed to further enhance the unbalance regulation ability and the harmonic tolerance of line currents, respectively. Finally, the proposed scheme is completed by combining the foregoing two elements with a predictive direct power control (PDPC). In order to verify the feasibility and validity of the proposed SOGI-VFPDPC, the scenarios of unbalanced voltage dip, higher harmonic distortion and grid frequency deviation are investigated in simulation and experimental studies. The corresponding results demonstrate that the proposed strategy ensures a balanced sinusoidal line current operation with excellent steady-state and transient behaviors under general grid conditions.

Lightning Surges Transferred to Low-voltage AC Power Lines through Distribution Transformers (배전용 변압기를 통하여 저압 전원선으로 전파되는 뇌서지)

  • 이복희;이동문;이수봉
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.4
    • /
    • pp.94-99
    • /
    • 2003
  • A strong need to improve the quality of electric power is increased because of increasing use of the sensitive and small-sized electronic devices. The transient overvoltages on low-voltage AC power distribution systems are induced by direct or indirect lightning return strokes, and they can cause damage and/or malfunction of the utility systems for home automation, office automation and factory automation as well as medical equipment. The behaviors of lightning overvoltages transferred through the transformer to the low voltage AC power distribution systems were experimentally investigated using a Marx generator. The surge voltages in low-voltage ac power systems are rarely limited by the application of the surge arrester to the primary side of distribution transformer and a custom service ground.

Performance Evaluation of SHF Sensor for Partial Discharge Signal Detection on DC Rectifier (DC 정류기 부분방전 신호검출을 위한 SHF 센서의 성능평가)

  • Jung, Ho-Sung;Park, Young;Na, Hee-Seung;Jang, Soon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.7
    • /
    • pp.1056-1060
    • /
    • 2012
  • Online monitoring system is becoming an essential element of railway traction system for utilized to condition based malignance management and various techniques currently employed in railway traction system. Among the various techniques, it is efficient to detect partial discharge signals by electromagnetic wave detection in order to detect insulation fault of rectifier. Although VHF (Very High Frequency), UHF (Ultra High Frequency) sensors were adopted to detect partial discharge of power facilities, due to characteristics of urban railway, excessive noise occurs from 500 MHz to 1.5 GHz on UHF bandwidth. In this paper a new measurement system able to monitoring the conditions of power facilities on DC substation in metro was studied and set up. The system uses UHF sensors to measure the partial discharge of the rectifier due to electric faulting and dielectric breakdown. Comparison and estimation for performance of SHF sensor which had devised to detect partial discharge signal of urban railway rectifier has conducted. In order to estimate performance of SHF sensor, we have compared the sensor with existing UHF sensor on sensitivity upon frequency bandwidth generated by pulse generator, and also we have verified performance of the SHF sensor by detection results of partial discharge signal from urban railway rectifier.

The Characteristics on the Hair Growth Using Diathermic Adjustable High-Frequency Generator (심부투열용 가변형 고주파 발생기를 적용한 발모 촉진 특성)

  • Shim, Ji-Young;Hong, Ji-Tae;Kim, Ho-Sung;Kim, Hee-Je
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1896-1897
    • /
    • 2007
  • Medical equipment of high frequency has been presently applied to various parts of human body and novel treatment effects have been shown by it. Recently there are many cases that high frequency apparatus has been used in dermatology as the interest in beauty has been growing. Especially used in skin, blood volume is increased by keeping surface temperature of skin at around $43^{\circ}C$ and domodex folliculorum are treated by applying high electric field. It is the aspect we consider that increasing blood volume and domodex folliculorum treatment take effect on hair loss. In this study, high frequency electrotherapy apparatus was proposed to be applied to hair loss treatment. For that, human body was experimented with varying output voltage and frequency. The adjustable switching signal for treatment was obtained from 100[kHz] to 1000[kHz] by using DSP. Stable output specific was also obtained by feedback control to protect human body. The best hair growth conditions were the output voltage of 1.2[kV], the frequency of near 300[kHz] and the maximum current of 2[mA]. We apply this high frequency electrotherapy apparatus to two bald men, 46-year-old and 45-year-old. After treatment for a month they had thick and strong hair.

  • PDF

A Study of the Cooling Effect for a Water-cooled Heat Structure of the Electric Vehicle Inverter System (수냉식 대용량 인버터의 방열구조에 따른 냉각효과에 대한 연구)

  • Kim, Gyoung-Man;Woo, Byung-Guk;Kang, Chan-Ho;Cho, Sang-Joon;Yun, Young-Deuk;Chun, Tae-Won
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.343-344
    • /
    • 2010
  • 화석연료의 고갈로 인하여 친환경 자동차에 대한 연구와 상용화가 급속도로 진행되면서 점점 대형 차종으로 그 범위가 넓어지고 있다. 대형 차종에 적용되는 전기동력 시스템의 MCU(Motor Control Unit), GCU(Generator Control Unit), DC/DC 컨버터 등과 같은 전장품도 그 용량이 커지면서 상용화를 위해 효율적인 측면도 많이 부각되지만 스위칭 소자, 변압기, 초크, 다이오드 등에서 동작으로 인해 열이 발생하고 제품의 구조상 밀폐된 공간에 장착이 되기 때문에 발열로 인한 동작의 신뢰성과 제품의 내구성에 큰 영향을 미치게 된다. 그중 가장 발열이 심한 IGBT(Insulated Gate Bipolar Transistor) 등과 같은 스위칭 소자에서 발생하는 열을 효과적으로 냉각시키기 위해 수냉구조가 필수적이며 동일한 조건의 수압, 유량에 보다 높은 방열특성을 가지기 위해 냉각구조에 대한 해석이 제품을 개발 전에 선행되어야 한다. 본 논문에서는 유로의 냉각핀 형상과 유로 구조에 따라 방열특성이 어떠한 차이가 있는지 시뮬레이션 프로그램을 통하여 비교하고, 모사발열체를 이용한 방열부의 냉각 성능 시험과 다이나모 환경의 최대 출력 시험을 통하여 방열 특성을 확인하였다.

  • PDF

Utilization of Active Diodes in Self-powered Sensorless Three-phase Boost-rectifiers for Energy Harvesting Applications

  • Tapia-Hernandez, Alejandro;Ponce-Silva, Mario;Olivares-Peregrino, Victor Hugo;Valdez-Resendiz, Jesus Elias;Hernandez-Gonzalez, Leobardo
    • Journal of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.1117-1126
    • /
    • 2017
  • The main contribution of this paper is the use of sensorless active diodes to generate the gate signals for a three-phase boost-rectifier with a self-powered control scheme. The sensorless operation is achieved making use of the gate control signals generated by the active diode schemes on each of the switching devices using a pulse width half-controlled boost rectifier modulation technique (PWM-HCBR). The proposed scheme synchronizes the gate control signals with a three phase voltage supply. Autonomous operation is obtained making use of the output DC bus to feed the control circuitry, the active diodes and the driver circuitry. The three-phase boost-rectifier is supplied by a three-phase permanent magnet electric generator powered by a solar concentrator dish with variable voltage and variable frequency conditions. Experimental results report an efficiency of up to 94.6% for 25 W and an input of 3.6 V peak per phase with 450.