• Title/Summary/Keyword: Electric Fault

Search Result 888, Processing Time 0.039 seconds

Modeling and Simulation Analysis of Grid-Connected Photovoltaic Generation System in terms of Dynamic behavior (계통연계형 태양광발전시스템의 동특성 모델링 및 모의해석)

  • Kim, Eung-Sang;Kim, Seul-Ki
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.127-131
    • /
    • 2005
  • The paper addresses modeling and analysis of a grid-connected photovoltaic generation system (PV system). PSCAD/EMIDC. an industry standard simulation tool for studying the transient behavior of electric power system and apparatus. is used to conduct all aspects of model implementation and to carry out extensive simulation study. An equivalent circuit model of a solar cell has been used for modeling solar array. A PWM voltage source inverter (VSI) and its current control scheme have been implemented. A maximum power point tracking (MPPT) technique is employed for drawing the maximum available energy from the PV array. Comprehensive simulation results are presented to examine PV array behaviors and PV system control performance in response to irradiation changes. In addition, dynamic responses of PV array and system to network fault conditions are simulated and analysed

  • PDF

Researches on The Aging Characteristics in Distribution Facilities (배전용(配電用) 기자재(機資材)의 열화특성(劣化特性) 고찰(考察))

  • Jang, Jeong-Tae;Koh, In-Seok;Hong, Soon-Hak
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.81-85
    • /
    • 1991
  • The distribution facilities fault has been anually shown about 13% all of the total distribution faults. Therefore, to prevent, the distribution facilities we have to manage them properly during their life time and enhance their quality and advance preventible maintenance, that is predictive maintenance or condition based maintenance. This paper presents the aging characteristics and the degenerating factors. Accordingly, improving the enhanced quality of distribution facilites is expected to contribute the electric power operation constantly.

  • PDF

Protection system of new superconducting power system (초전도(신)전력계통 보호시스템에 관한 기본연구)

  • Lee, Seung-Ryul;Yoon, Jae-Young;Yang, Byeong-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.292-293
    • /
    • 2011
  • We proposed a new power system, Superconducting Power System. The SPS consists of superconducting power cables, fault current limiters, and transformers. The basic concept is to replace 154kV conventional cables with 22.9kV superconducting cables and to convert a 154kV substation into a 22.9kV switching station in downtown area. For the application of the SPS to real power system, it is very important to construct the protection system of the SPS. This study presents a protection system for the new Superconducting Power System (SPS).

  • PDF

A Research About Applicable Electric Field Calculation for Resistive Type Superconducting Fault Current Limiter in the System with Line Resistance (라인 저항이 포함된 시스템에서 저항형 한류기 허용 전기장 산출 연구)

  • Lee, Woo-Seung;Jang, Jae-Young;Choi, Suk-Jin;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.971-972
    • /
    • 2011
  • 초전도 저항형 한류기는 계통에서 발생하는 대규모의 사고 전류를 매우 빠른 시간 안에 효과적으로 제한할 수 있어 주목받고 있는 초전도 전력기기이다. 저항형 한류기를 제작할 때 사용되는 초전도 선재의 총 길이는 저항형 한류기의 전체 설계에 있어서 가장 핵심적인 변수중 하나로 기존의 허용전기장을 이용한 방법으로 도출될 수 있다. 하지만 기존의 방법에서는 계통의 라인 저항을 고려하지 않는 가정을 도입 했기 때문에 이를 이용하여 설계할 경우 실제로 시스템에서 요구하는 설계 변수와 큰 차이를 보일 수 있다. 본 논문에서는 라인저항의 영향을 고려한 허용 전기장을 도출하고, 새로 계산된 선재의 길이와 기존의 방법을 이용하여 계산된 선재의 길이를 비교해 봄으로써 보다 정확한 설계의 가능성을 제시한다.

  • PDF

Basic study on developing Power-SemiConductor-Type Fault Current Limiter based on Magnetic Turn-Off principle (자계소호 원리를 이용한 전력전자형 고장전류제한기 구조에 관한 기초연구)

  • Kang, Ji-Seong;Ji, Geun-Yang;Jung, Won-Sik;Moon, Young-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.174-175
    • /
    • 2011
  • 본 논문에서는 자계소호(Magnetic Trun-Off) 원리를 이용한 전류제한기를 제안하였다. 본 한류기는 전력전자 소자를 이용하여 고장시 신속한 제어가 가능하고, 동작시 역전압 및 반발력이 발생하지 않으므로 고도의 동작 신뢰성을 확보할 수 있다는 장점이 있다. 또한 본 한류기는 유도형 초전도 한류기와 원리는 유사하나, 초전도 소자를 이용하지 않으므로 극저온 유지장치를 제거할 수 있고 ��치시 복귀 기술이 별도로 필요하지 않다는 장점이 있다. 따라서 본 한류기를 우리나라 전력계통에 적용한다면 차단기의 재폐로 동작책무를 완벽하게 만족하는 안정적인 계통운영이 가능할 뿐 아니라, 고장전류 증가에 따른 차단기 교체비용 절감이 가능하다.

  • PDF

A Study on the Maximum Capacity Rate of Distributed Generation Considering Power System Transient Stability (분산형전원 투입시 전력계통의 과도안정도 유지 한계용량 산정)

  • Kim, Yong-Ha;Lim, Hyun-Sung;Jung, Hyun-Sung;Back, Bum-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.4
    • /
    • pp.718-724
    • /
    • 2009
  • Recently, Increase of energy consumption is continued accordingly because economy is constant growth. so we need long term of energy supply stability and develop new energy source. The effort of environmental improvement is necessary and our country has to educe conservatory gas in these situation, our energy policy is summarized that minimizes energy consumption and uses kinds of energy source. This paper studied some effort of stability that distributed generation put in electric system through line fault, sudden load change. And then this paper calculated penetrated level of distributed generation in system transient stability.

Electromagnetic Force Analysis for 154kV Underground Cable by Fault Current (고장전류에 의한 154kV 지중케이블의 작용 전자력 해석)

  • Jang, Tae-In;Park, Hung-Sok;Kang, Ji-Won;Yoon, Hyung-Hee;Hong, Dong-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.187-188
    • /
    • 2008
  • 본 논문은 지중송전케이블 사고 시 수반되는 고장전류가 케이블에 미치는 전자력 영향에 대한 내용을 다룬다. 지중송전선로는 도심지 및 인구밀집 지역의 안정적 전력공급에 필수불가결한 송전방식이나 전력구 등의 제한된 설치 공간으로 인하여 최대한 밀집배치 되므로 고장 시 고장전류에 의한 전자력의 상호작용이 가공선로에 비하여 매우 커서 이에 대한 면밀한 검토가 필요하다. 본 문에서는 전력구내 포설 형태와 고장상황에 따른 케이블 상호간 작용 전자력에 대하여 심층적으로 분석하여, 향후 전자력 영향 감소 및 해소를 위한 지지용 금구류 등의 개선 및 개발을 위한 기본 자료로 활용하고자 한다.

  • PDF

Surveillance System For Extra High Voltage Cable (초고압 CABLE 감시시스템 연구)

  • Hahn, K.M.;Lee, K.C.;Jeon, S.I.;Kim, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.789-793
    • /
    • 1992
  • For improving the power supply reliability and minimizing maintenance work of E.H.V. underground transmission line, new surveillance systems are strongly desired for use in the field of electric power transmission. For underground installation, high system reliability is required because E.H.V. cables, if an accident happen, can have a serious impact on social activities and human life. In answer to this requirement, applications of optical fiber transmission system have been widely developed in a variety of field. The main function of this system are cable fault location, oil leak detection, and surveillance of the cable circuit and tunnel condition.

  • PDF

The Development of the Single-Phase Electric Power Information Management Module of the Intelligent Electrical Switchgear Panel with Arc Fault Diagnosis function (아크고장 진단기능을 고려한 지능형 분전반의 단상 전력관리 모듈 설계에 대한 연구)

  • Ko, Yun-Seok;Lee, Seo-Han;Choi, Hyun-Chul;Lee, Han-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2255_2256
    • /
    • 2009
  • 주택용 분전반내의 과부하 차단기(MCCB)나 누전차단기(ELCB)들은 전류 RMS 크기만을 가지고 고장전류를 인식하기 때문에 아크고장전류를 차단하지 못해, 수용가들은 전기화재로 인한 심각한 인명피해나 재산상의 손실을 자주 경험할 수 있다. 따라서 본 연구에서는 이러한 문제를 해소하기 위해 아크진단 기능을 가지는 지능형 분전반을 제안하고자 한다. 특히 여기에서는 아크고장 진단 기능을 고려한 지능형 분전반의 단상 전력관리 모듈 설계연구를 주 목적으로 한다.

  • PDF

A study on the key Issues for implementing the IEC61850 based Gateway (IEC61850 기반의 Gateway 개발을 위한 이슈에 관한 연구)

  • Oh, Moo-Nam;Lee, Suk-Bea;Woo, Chun-Hee;Kim, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.91_92
    • /
    • 2009
  • As the increasing integrity of VLSI, the BIST(Built-In Self Test) is used as an effective method to test chips. Generally the pseudo-random test pattern generation is used for BIST. But it requires too many test patterns when there exist random resistant faults. Therefore we propose a mixed test scheme which applies to the circuit under test, a deterministic test sequence followed by a pseudo-random one. This scheme allows the maximum fault coverage detection to be achieved, furthermore the silicon area overhead of the mixed hardware generator can be reduced.

  • PDF