• Title/Summary/Keyword: Electric Energy

Search Result 5,268, Processing Time 0.03 seconds

High Efficiency Switch-Mode LED driver for Visible Light Communication System (가시광 통신 시스템을 위한 고효율 스위치모드 LED 구동회로)

  • Kang, Jung-Min;Cho, Sang-Ho;Hong, Sung-Soo;Han, Sang-Kyoo;SaKong, Suk-Chin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.358-365
    • /
    • 2011
  • Recently, the LED(Light Emitting Diode) replacing incandescent light bulbs and fluorescent light has great attentions as a most promising candidate for the next generation lighting source due to its environment-friendly characteristics, long life and excellent efficiency. Moreover, since it is a semiconductor device which can convert the electric energy to visible light at a very high speed, it can also used as a communication device. Therefore, the VLC(Visible Light Communication) using the LED can perform the near field communication and lighting function at the same time without additional expenses. However, since the switching device of the conventional LED driver for VLC is operated in the linear region, there exist several drawbacks such as a poor power conversion efficiency and serious heat generation. On the other hand, since the proposed driver is operated in the on/off switching region, it features a higher efficiency and more improved heat generation. To verify the validity of the proposed LED driver, experimental results from a prototype of 20W rated LED driver applied to 3MHz bps broadcasting audio system are given.

Analysis of Induced Voltage on the Gas Pipeline at the Fault in a Underground Power Cables (지중전력케이블에서 고장발생시 인근 가스배관에 유도되는 전압 해석)

  • Bae J. H.;Kim D. K.;Kim K. J.
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.3 s.11
    • /
    • pp.26-32
    • /
    • 2000
  • Because of the continuous growth of energy consumption, and also the tendency to site power lines and pipelines along the same routes, the close proximity of high voltage structures and metallic pipelines has become more and more frequent. Moreover, normal steady state and fault currents become higher as electric networks increase in size and power Therefore, there has been and still is a growing concern(safety of people marking contact with pipeline, risk of damage to the pipeline coating, the metal and equipment connected to pipeline, especially cathodic protection system) about possible hazards resulting from the influence of high voltage power system on metallic structures(gas pipeline, oil pipeline and water pipeline etc.). Therefore, we analyze the interference problems when the gas pipeline is buried with power cable in the same submarine tunnel. This paper present the results of the study about interference mechanism, AC corrosion limitation of safety voltage and analysis of induction voltage.

  • PDF

ELF-MT Survey Between Sindangri and Dojonri Area in the Okchon Zone (옥천대내(沃川帶內) 신당(新堂)-도전리(道田里) 지역(地域)에 대한 ELF-MT 탐사(探査) 연구(硏究))

  • Min, Kyung Duck;Jeon, Jeong Soo;Chung, Seung Hwan
    • Economic and Environmental Geology
    • /
    • v.21 no.3
    • /
    • pp.277-285
    • /
    • 1988
  • The ELF-MT survey has been conducted at 9 points along the national road between the Sindangri and Dojonri area to study on the boundary between the Okchon and Choson systems, and subsurface geological structure of these two systems. Natural electromagnetic fields of 7.8, 14, and 20 Hz in the Schumann resonant frequency band were used for ELF-MT measurement. Apparent resistivity values were calculated from the measured magnetic and electric fields at each frequency, and resistivity sections were obtained by means of a trial and error method for one-dimensional analysis and finite element method for two-dimensioal analysis. The results of this study show that the resistivities of the Okchon and Choson systems are 700-3500 ohm-m and 40-5000 ohm-m, respectively. The boundary between these two systems is a fault with the width of 1 km fault zone and resistivity value of 200 ohm-m, and is located around Koburangjae. Another fault is appeared in Sindangri, and its resistivity value is 130 ohm-m. Intrusion of biotite granite is distributed in Jungchijae, and its resistivity value is 750 ohm-m. The area between Susanri and Koburangjae shows the highest resistivity value of 3500 ohm-m because metabasite and amphibolite are distributed in that area. Extremely low resistivity value of 40 ohm-m around Yongamsan is due to the Yongam formation, which is composed of graphitic black slate and overlying Choson Great Limestone group.

  • PDF

THEMIS Pi2 observations near dawn and dusk sectors in the inner magnetosphere

  • Kwon, Hyuck-Jin;Kim, Khan-Hyuk;Lee, Dong-Hun;Takahashi, K.;Park, Young-Deuk;Bonnell, J.W.
    • Bulletin of the Korean Space Science Society
    • /
    • 2010.04a
    • /
    • pp.40.3-40.3
    • /
    • 2010
  • The most frequently suggested source for Pi2 pulsations in the inner magnetosphere (L < 4) is standing fast-mode waves trapped in the plasmasphere (i.e., plasmaspheric resonances). They have been considered as the source of low-latitude Pi2 pulsations. The plasmaspheric resonance model suggests that compressional fast-mode waves can be detected at all local times inside the plasmasphere provided reflection of the wave energy is efficient. Until now, however, there are no reports about compressional Pi2s observed in the dayside inner magnetosphere. That is, there is longitudinal limit of inner magnetosphere. In February 2008, THEMIS probes were near dawn and/or dusk sides, which are the transition regions between the nightside and dayside, in the inner magnetosphere (L = 2-4) when low-altitude Pi2s were identified at Bohyun (L = 1.35) station in Korea. Using the THEMIS electric field data, we examined if Pi2s are excited by longitudinally localized disturbances. We found that compressional Pi2s having high coherence with a low-latitude Pi2 pulsation occur on dawnside. However, any compressional pulsations in the Pi2 frequency band were not detected on duskside. This indicates that compressional Pi2s disappear near the duskside. Our observations are discussed with spatial plasmaspheric structure and possible Pi2 mechanisms.

  • PDF

Eigenvalue Analysis and Detection of Low Frequency Oscillation using PMU Data in KEPCO System (위상동기신호를 이용한 한전계통의 저주파진동 검출과 고유치해석)

  • Shim, Kwan-Shik;Kim, Sang-Tae;Kim, Tae-Kyun;Ahn, Seon-Ju;Choi, Joon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.2
    • /
    • pp.261-284
    • /
    • 2017
  • This paper describes the results of a low-frequency oscillation analysis using data measured in PMU installed in the KEPCO system, and the comparison with eigenvalues computed from the linear model. The dominant oscillation modes are estimated by applying various algorithms. The algorithms are: the extended Prony method; multiple time interval parameter estimation method; subspace system identification method; and spectral analysis. From the measurement data, modes of frequency 0.68[Hz] and 0.92[Hz] were estimated, and modes of frequency 0.63[Hz] and 0.80[Hz] were computed from the eigenvalue calculation. There was a difference between the mode estimated from measurement data and that from the linear model. This is possibly because of an error in the dynamic data of the KEPCO system used in eigenvalue calculation. Because wide area modes exist in the KEPCO system, these modes should be monitored continuously for the reliable operation of the system. In order to prevent total blackouts caused by wide area oscillation, moreover, contingency analysis should be performed in relation to this mode and appropriate measures should be established.

The Electric Characteristics of Asymmetric Hybrid Supercapacitor Modules with Li4Ti5O11 Electrode (Li4Ti5O11 전극을 이용한 비대칭 하이브리드 슈퍼커패시터 전기적 모듈 특성)

  • Maeng, Ju-Cheul;Yoon, Jung-Rag
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.2
    • /
    • pp.357-362
    • /
    • 2017
  • Among the lithium metal oxides for asymmetric hybrid supercapacitor, $Li_4Ti_5O_{12}(LTO)$ is an emerging electrode material as zero-stain material in volume change during the with the charging and discharging processes. The pulverized LTO powder was observed to show the enhanced capacity from 120 mAh/g to 156 mAh/g at C-rate (10, 100 C). Hybrid supercapacitor module(48V, 416F) was fabricated using an asymmetric hybrid capacitor with a capacitance of 7500F. As a result of the measurement of C-rate characteristics, the module shows that the discharge time is drastically reduced at more than 50C, and the ESR and voltage drop characteristics are increased. The energy density and power density were reduced under high C-rate conditions. When designing asymmetric hybrid supercapacitor module, the C-rate and ESR should be considered As a result of measuring the 5 kw UPS, it was discharged at the current of 116A~170A during the discharge in the voltage range of 48V~30V, and the compensation time at discharge was measured to be about 33.2s. Experimental results show that it can be applied to applications related to stabilization of power quality by applying hybrid supercapacitor module.

A Study on Characteristic Analysis of AC to AC Current-Fed Type High Frequency Resonant Inverter with High Power Factor (고역율 AC/AC 전류형 고주파 공진 인버터의 특성해석에 관한 연구)

  • Kim, Jong-Hae;Won, Jae-Sun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.1
    • /
    • pp.16-28
    • /
    • 2014
  • This paper presents a novel high-power-factor circuit topology of AC to AC current-fed type high frequency resonant inverter which includes the function of power factor correction(PFC) in the proposed inverter to operate the AC input block with high power factor. The proposed circuit topology of AC to AC current fed type high resonant inverter removes DC link electrolytic capacitor and has also the one of power factor correction(PFC) in the inverter circuit without an additional PFC circuit since the input current by constituting it in parallel as an unit inverter, which assumes the class-E high frequency resonant inverter of conventional current-fed type, flows in the form of the resultant current flowing through each constant current reactor($L_{d1}$, $L_{d2}$). The circuit analysis of proposed inverter is generally described by adopting the normalized parameters and the evaluation of its operating characteristics are conducted by using the parameters such as the ratio of switching and resonant frequency(${\mu}$), coupling coefficient(k) and so on. An example of procedure for circuit design based on the characteristic values obtained from the theoretical analysis is presented. To confirm the validity of the theoretical analysis, the experimental results are also presented. In the future, the proposed inverter shows it can be practically used as power supply system for induction heating application, DC-DC converter etc.

Comparative Analysis of PBTI Induced Device Degradation in Junctionless and Inversion Mode Multiple-Gate MOSFET (PBTI에 의한 무접합 및 반전모드 다중게이트 MOSFET의 소자 특성 저하 비교 분석)

  • Kim, Jin-Su;Hong, Jin-Woo;Kim, Hye-Mi;Lee, Jae-Ki;Park, Jong-Tae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.1
    • /
    • pp.151-157
    • /
    • 2013
  • In this paper, a comparative analysis of PBTI induced device degradation in nanowire n-channel junctionless and inversion mode Multiple-Gate MOSFET(MuGFETs) has been performed. It has been observed that the threshold voltage is increased after PBTI stress and the threshold voltage variation of junctionless device is less significant than that of inversion mode device. However the degradation rate of junctionless device is less significant than that of inversion mode device. The activation energy of the device degradation is larger in inversion mode device than junctionless device. In order to analyze the more significant PBTI induced device degradation in inversion mode device than junctionless device, 3-dimensional device simulation has been performed. The electron concentration in inversion mode device is equal to the one in junctionless device but the electric field in inversion mode device is larger than junctionless device.

Reduction behavior of Zn, Pb, Cl, Fe, Cu and Cd compounds in EAF dust with carbon (탄소에 의한 전기로 분진 중 Zn, Pb, Cl, Fe, Cu 및 Cd화합물의 환원반응)

  • 이재운;김영진;서성규;이광학;김영홍
    • Resources Recycling
    • /
    • v.9 no.4
    • /
    • pp.3-15
    • /
    • 2000
  • Reduction of Electric Arc Furnace dust with carbon (graphite) was studied at the temperature range of $800^{\circ}C$ to $1100^{\circ}C$ in Ar gas atmosphere. The briquetted dust with graphite powder was heated in a vertical tube furnace for given reaction time and Quenched in Ar gas atmosphere. It was found that initially the reduction of Zn was chemically controlled and the activation energy was about 120 KJ/mole. Because the almost all of Pb was removed with Cl in the form of $PbCl_2$, it is considered that Pb is removed by chloride reduction. Cu was vaporized as a chloride up to 30% of its original content, but the remaining of Cu would be accumulated with the reduced iron. and also, Cd was removed completely within 15 min. at $1000^{\circ}C$.

  • PDF

Modeling of Practical Photovoltaic Generation System using Controllable Current Source based Inverter (제어 가능한 전류원 기반의 인버터를 이용한 실제적 태양광 발전 시스템 모델링)

  • Oh, Yun-Sik;Cho, Kyu-Jung;Kim, Min-Sung;Kim, Ji-Soo;Kang, Sung-Bum;Kim, Chul-Hwan;Lee, You-Jin;Ko, Yun-Tae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.8
    • /
    • pp.1340-1346
    • /
    • 2016
  • Utilization of Distributed Generations (DGs) using Renewable Energy Sources (RESs) has been constantly increasing as they provide a lot of environmental, economic merits. In spite of these merits, some problems with respect to voltage profile, protection and its coordination system due to reverse power flow could happen. In order to analyze and solve the problems, accurate modeling of DG systems should be preceded as a fundamental research task. In this paper, we present a PhotoVoltaic (PV) generation system which consists of practical PV cells with series and parallel resistor and an inverter for interconnection with a main distribution system. The inverter is based on controllable current source which is capable of controlling power factors, active and reactive powers within a certain limit related to amount of PV generation. To verify performance of the model, a distribution system based on actual data is modeled by using ElectroMagnetic Transient Program (EMTP) software. Computer simulations according to various conditions are also performed and it is shown from simulation results that the model presented is very effective to study DG-related researches.