• 제목/요약/키워드: Electric Compressor

검색결과 140건 처리시간 0.024초

소규모 매립가스 자원화를 위한 마이크로터빈 열병합발전 및 유리온실 $CO_2$ 농도 증가 시스템의 타당성 연구 (Feasibility Study of Microturbine CHP and Greenhouse $CO_2$ Enrichment System as Small Scale LFG Energy Project)

  • 박정극;허광범;임상규;이인화
    • 신재생에너지
    • /
    • 제5권2호
    • /
    • pp.15-24
    • /
    • 2009
  • As new small scale LFG (landfill gas) energy project model which can improve economic feasibility limited due to the economy of scale, LFG-Microturbine combined heat and power system with $CO_2$ fertilization into greenhouses was proposed and investigated including basic design process prior to the system installation at Gwang-ju metro sanitary landfill. The system features $CH_4$ enrichment for stable microturbine operation, reduction of compressor power consumption and low CO emission, and $CO_2$ supplement into greenhouse for enhancement plant growth. From many other researches, high $CO_2$ concentration was found to enhance $CO_2$ assimilation (also known as photosynthesis reaction) which converts $CO_2$ and $H_2O$ to sugar using light energy. For small scale landfills which produce LFG under $3\;m^3$/min, among currently available prime movers, microturbine is the most suitable power generation system and its low electric efficiency can be improved with heat recovery. Besides, since its exhaust gas contains very low level of harmful contaminants to plant growth such as NOx, CO and SOx, microturbine exhaust gas is a suitable and economically advantageous $CO_2$ source for $CO_2$ fertilization in greenhouse. The LFG-Microturbine combined heat and power generation system with $CO_2$ fertilization into greenhouse gas to enhance plant growth is technologically and economically feasible and improves economical feasibility compared to other small scale LFG energy project model.

  • PDF

리니어엔진을 이용한 파워팩의 운전조건에 따른 발전출력에 관한 연구 (A Study for Generating Power on Operating Parameters of Powerpack utilizng Linear Engine)

  • 오용일;김강출;임옥택
    • 한국수소및신에너지학회논문집
    • /
    • 제23권2호
    • /
    • pp.183-190
    • /
    • 2012
  • The research shows the experiment results according to the combustion characteristics and configuration of the linear generator of powerpack for the generating power applying the 2-stroke compact linear engine. The powerpack used in this paper consists of 2-stroke linear engine, linear generator and air compressor parts. For identifying the combustion characteristics and generating power of linear engine, some parameters were varied sucha as electric load, fuel input calorie, spark timing delay and equivalence ratio. Also generating power was confirmed at each operation conditions, when the air gap length of linear generator part was changed as each 1.0 mm and 2.0 mm. During the all operations, intake air was inputted under the wide open throttle. Mass flow rate of air and fuel was changed using mass flow controller, after these were premixed by premixture device, and then premixed gas was supplied directly into each cylinder. As a result, piston frequency and combustion characteristics were different at each conditions according to parameters affecting the combustion such as fuel input calorie, resistive load, spark timing delay and equivalence ratio. Consequently, these had an effect on generating power.

열펌프를 이용한 양액베드 냉난방시스템 개발 (Development of Heating and Cooling System with Heat Pump for Nutrient Solution Bed In Greenhouse)

  • Kang, Geum-Chun;Kim, Yeong-Jung;Yu, Yeong-Seon;Baek, Lee
    • Journal of Biosystems Engineering
    • /
    • 제27권6호
    • /
    • pp.565-572
    • /
    • 2002
  • In order to control the root-zone temperature of greenhouse crops in the hydroponics at hot and cold season, heat pump system for cooling and heating was built and tested in this work. The system was air-to-water type and vapour compression type. The heating and cooling mode was selected by the four way valve. Capacity of the compressor was 3.75㎾ and heat transfer area of the evaporator and the condenser were 3.05㎡ and 0.6㎡, respectively. According to the performance test, it could supply heat of 42,360 to 64,372kJ/h depending on the water circulation rate of 600 to 1,500ℓ/h, respectively, when indoor air temperature was 10∼20$\^{C}$. COP of heat pump system was 3.0 to 4.0 in the heating mode. But, COP of the cooling mode was 1.3 to 2.1 at indoor temperature of 20∼35$\^{C}$. The feasibility test in the greenhouse the developed heating and cooling system was installed, showed that the heating cost of the developed system was only about 13% of that of the conventional heating system. The heating cost of the developed system was 367won/day(electric consumption 9.7㎾h/day), while that of the conventional system was 2,803won/day(oil consumption 7.7ℓ/day) at the same heating mode.

관측 위치를 지령치로 하는 새로운 속도추정 알고리즘을 이용한 BLAC 속도제어 (BLAC speed contol using precision Velocity Estimation through the Rotor Position ObservationR)

  • 이상훈;송현직;박찬규
    • 한국산업융합학회 논문집
    • /
    • 제17권3호
    • /
    • pp.93-102
    • /
    • 2014
  • Recently the interest in permanent magnet alternating motor using for electric compressor become great. Especially the research on Interior Permanent Magnet Motor has been doing actively for its advantages in the energy density and the efficiency. In order to control the output of motor to the desired value, the current control or speed control of motor are required. The accurate detection of rotor position and speed information are necessary for the control of motor. In general, the encoder, hall sensor, and resolver are used to obtain the information of motor position and speed and the speed detection algorithm, M/T method, is applied. However, the M/T method causes the error depending on rotor speed. Therefore, this M/T speed detection method is not perfect. In this paper, it is proposed that the PI control with a 1st transfer function and the integration element between velocity and position are composed in series and this feeds back to the reference value of position angle. The proposed algorithm is a function of the integral elements 2nd term, speed element, is used as an output. Thus, it is possible to detect the correct speed by configuring like the mechanical structure similarly. The proposed algorithm is verified by using PSIM DLL and is applied to the BLAC motor drive. And also it is confirmed that this system estimates the accurate speed regardless of rotor speed changes. As a example, the experimental results and simulations shows that the proposed method is very effective.

복합용도 건물에 적용된 400RT급 수직형 지열시스템의 입주전 성능평가 (A Performance Measurement and Evaluation of a 400RT Vertical type Geothermal System installed in a Complex Building Before Occupancy)

  • 황광일;신동걸;김중헌;신승호;정명관
    • 한국태양에너지학회 논문집
    • /
    • 제28권3호
    • /
    • pp.7-14
    • /
    • 2008
  • 400RT geothermal system which is the biggest capacity among on-operations at present in Korea is measured and evaluated on 23rd${\sim}$26th Jan. 2008 during those days building is not allowed owners and/or tenants to move in. The geothermal system is consist with vertical-typed 112 geothermal heat exchangers which are installed circle-like 1 row with 4m interval, and has 16 units of 25USRT geothermal-source heat pump(GSHP)s. And each 5 units of circulation pump are running for geothermal heat exchangers and hot water supplies. The followings are the results. The temperatures at G.L. -70m of 2 boreholes are varied quite similarly. The average temperature difference between inlet and outlet of geothermal pipes is $4.1^{\circ}C$, and that of hot water supply is $3.2^{\circ}C$, of Zone 3's each 4 GSHPs when being operated. Despite temperature fluctuations by heating loads, the average temperature difference between main pipes of inlet and outlet of geothermal heat exchangers is measured as $4.1^{\circ}C$. This study propose "Geothermal System COP" which includes not only consumed electric power by compressor but also circulation pumps and auxiliary utilities. By comparing the geothermal system COP with GSHP's performance specification, it is clear that the performances of GHSPs of this site are satisfied with the specification.

직결형 초음속 연소기 시험 설비 개발 (Development of a Direct-Connected Supersonic Combustor Test Facility)

  • 양인영;이경재;이양지;김형모
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.290-293
    • /
    • 2017
  • 스크램젯 엔진용 초음속 연소기 연구를 위한 직결형, 연속식 연소 시험 설비를 개발하였다. 비행체 속도 마하 5, 연소기 입구 유속 마하 2를 가정하고, 시험 대상 연소기의 유로 단면은 높이 32 mm, 폭 70 mm로 가정하여 설비 요구 조건을 결정하였다. 이에 따라 설비는 유동 전압력 548 kPaA, 전온도 1,320 K, 유량 0.776 kg/s로 설계하였다. 설비는 터보형 압축기, 전기 가열기 및 연소식 가열기와 그 하류에 유동 가속을 위해 장착한 마하 2의 2차원 노즐로 구성하였다. 노즐 상류에서 산소를 추가 공급하여 연소식 공기 가열에 의한 산소 감소를 보상하도록 하였다. 배기는 별도의 감압은 하지 않았다. 저압, 저유량에서의 시운전을 수행하였으며, 설계점 운전은 향후 계획 중에 있다.

  • PDF

무공해 승용 자동차의 냉방을 위한 전동식 냉방시스템 성능에 관한 연구 (Performance Characteristics of the Electrical Air Conditioning System for the Zero Emission Passenger Vehicle)

  • 이무연;조중원;이호성;원종필
    • 한국산학기술학회논문지
    • /
    • 제12권12호
    • /
    • pp.5430-5437
    • /
    • 2011
  • 본 연구의 목적은 친환경 무공해 승용 차량에 적용되는 전동식 냉방시스템의 성능특성을 실차에서 확인하는 것이다. 이를 위하여 인버터로 구동되는 전동식 스크롤 압축기를 적용한 전동식 냉방시스템을 설계 및 제작하여 수소 연료전지 자동차에 설치하여 다양한 주행도로 조건에서 실험을 진행하였다. 주행조건의 변화는 시험차량에 장착된 전동식 냉방시스템의 성능에 영향을 주었으며, 고속 및 일반도로 주행조건에서 냉방시스템의 성능이 정지조건에서 냉방시스템의 성능보다 우수하게 나타났다. 또한, 외기온도가 $20.0^{\circ}C$에서 $30.0^{\circ}C$로 증가함에 따라 고내 온도는 평균 $5.2^{\circ}C$ 더 적게 감소하였다.

소형 선박용 연료전지 시스템 모델 개발 (Development of a Fuel Cell System Model for a Small Ship)

  • 방은신;김영민;김명환;박상균
    • 해양환경안전학회지
    • /
    • 제26권5호
    • /
    • pp.569-575
    • /
    • 2020
  • 본 연구에서는 선박 전원용 연료전지 시스템 모델을 개발하여 순수한 산소를 공급하여 진행한 실험 결과의 비교를 통하여 연료전지 시스템 모델을 검증하였다. 검증된 모델을 활용하여 공기 압축기를 사용하여 공기를 공급할 경우에 대하여 산소를 공급한 경우와의 연료전지 출력 특성을 비교 검토하였다. 또한, 연료전지 시스템의 열물성치 변화가 스택의 출력에 어떠한 영향을 미치는지에 관하여 검토하였다. 그 결과 본 연구의 실험 범위에서 캐소드 공급 가스로 순수한 산소를 공급한 경우의 모델링을 통한 계산 결과와 실험 결과는 전 부하 영역에서 거의 동일한 전압 및 출력을 얻을 수 있었다. 560 A의 일정한 부하에서 캐소드 공급용 산소를 대신하여 공기를 공급한 경우 각각의 스택 전압은 약 14 V, 스택 출력은 약 8 kW, 스택 효율은 약 3 % 및 전체 시스템 효율은 8 % 정도 낮아짐을 알 수 있었다. 본 연구에서 검토한 열물성치 중에서 스택에 대한 냉각수의 열전달 계수가 스택의 출력에 가장 큰 영향을 미침을 알 수 있었다.

발전용 저압터빈 최종단 블레이드의 정적 유체-구조 연계해석 (Static Fluid-Structure Coupled Analysis of Low-Pressure Final-Stage Turbine Blade)

  • 권순국;이영신;배용채
    • 대한기계학회논문집A
    • /
    • 제34권8호
    • /
    • pp.1067-1074
    • /
    • 2010
  • 본 논문에서는, 운전조건에서의 저압최종단 블레이드에 대하여 약결합 유체-구조 연계해석기법을 이용한 해석이 수행되었다. 저압터빈 최종단에 대한 해석이전에 경계조건에 대한 검증을 위하여 15도 후퇴익과 NASA Rotor 37을 대상으로 예비해석이 수행되었다. 각각의 해석결과들을 기존 문헌들과 비교하였다. 15도 후퇴익에 대한 안정상태와 불안정상태에서 동적 FSI해석이 수행되었다. 해석결과 변위가 일정한 안정상태에 비하여 고속에서는 0.05 초 만에 발산하는 결과를 산출하였다. NASA Rotor 37의 정상상태 해석결과를 바탕으로 정적 동적 FSI 해석을 수행하여 뒷전의 변형크기에 대하여 정적 FSI 결과와 동적 FSI간의 차이가 있음을 확인하였다. 저압 최종단 블레이드의 형상측정 및 동특성시험을 바탕으로 해석모델을 생성하였다. 이를 바탕으로, 운전조건에서 저압최종단 블레이드에 대한 정적 유체-구조 연계해석을 성공적으로 수행하였다.

화열(火熱)이 에폭시수지로 보수·보강된 콘크리트 구조체의 내구성에 미치는 영향에 관한 연구 (A Study on the Effect of Fire Heat on the Durability of Concrete Structures Repaired and Reinforced with Epoxy Resin)

  • 조태관
    • 한국재난정보학회 논문집
    • /
    • 제19권1호
    • /
    • pp.138-145
    • /
    • 2023
  • 연구목적: 건축물의 노후화에 따른 보수, 보강 건축물의 증가에 따라 기 보강된 건축물에 화재가 발생시 화재 후 구조물에 미치는 영향성을 분석하여 보수, 보강대책의 기준을 마련하고자 한다. 연구방법: 콘크리트 배합설계에 의한 공시체를 제작하여 28일 양생 후 압축기를 통해 압축강도 측정 및 파괴를 유도후 에폭시로 보수, 보강하여 3일 양생 후 일부공시체를 재 압축강도시험을 실시하여 강도 복원 정도를 파악하고 보수, 보강한 나머지와 보수, 보강하지 않은 공시체를 실험용 전기로에 넣고 시간, 온도별로 가열한 후 압축강도를 실험하여 화재의 영향성을 추정함. 연구결과: 항복된 공시체를 에폭시로 보강한 후 실험용전기로에 넣어 가열을 시간별로 온도의 차이를 주어 실험한 결과 높은 온도에서 열 영향을 받는 시간이 길면 길수록 강도의 저하가 발생함을 알 수 있었고 보수, 보강되지 않은 공시체보다 더 강도 저하가 있음을 알 수 있었다. 결론: 이를 토대로 볼 때 에폭시 수지로 보수, 보강된 건축물이 화해를 입을 때는 일반 보수되지 않은 건축물보다 더 위험함을 알 수 있었으므로 화재에 대한 안정성을 고려하였을 때 보수보강 표면에 내화피복재 등을 도포하는 등 화재 취약에 대비하여야하겠다.