• Title/Summary/Keyword: Electric Charge

Search Result 1,133, Processing Time 0.035 seconds

Effect of $Al^{3+}$ Dopant on the Electrochemical Characteristics Of Spinel-type $Li_{4}Ti_{5}O_{12}$ (스피넬형 $Li_{4}Ti_{5}O_{12}$ 음극물질의 $Al^{3+}$ 첨가에 의한 전기화학적 성능 변화)

  • Jeong, Choong-Hoon;Lee, Eui-Kyung;Bang, Jong-Min;Lee, Bong-Hee;Cho, Byung-Won;Na, Byung-Ki
    • Clean Technology
    • /
    • v.14 no.3
    • /
    • pp.171-175
    • /
    • 2008
  • The effect of the addition of $Al^{3+}$ dopant on the electrochemical characteristics of $Li_{4}Ti_{5}O_{12}$ was investigated. $Li_{4}Ti_{5}O_{12}$ is known as a 2ero-strain material, and $Li_{3.95}Al_{0.15}Ti_{4.9}O_{12}$ has been manufactured by solid-state reaction with high energy ball milling (HEBM). The samples were heated at 800, 900 and $1000^{\circ}C$ in electric furnace. The structural and surface structures were measured by XRD (X-ray diffraction) and SEM (scanning electron microscopy). Cut-off voltage of charge/discharge cycles was $1.0{\sim}3.0 V$ to investigate reversible capacity, cycle stability and plateau voltage. The reversible capacity of $Li_{3.95}Al_{0.15}Ti_{4.9}O_{12}$ was 138 mAh/g.

  • PDF

Studies on the Optical and the Electrical Characterization of Organic Electroluminescence Devices of Europium Complex Fabricated with PVD(Physical Vopor Deposition) Technique (진공 증착법에 의하여 제작한 Europium complex 유기 박막 전기발광소자의 광학적.전기적 특성에 관한 연구.)

  • Lee, Myeong-Ho;Lee, Han-Seong;Kim, Yeong-Gwan;Kim, Jeong-Su
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.5
    • /
    • pp.285-295
    • /
    • 1999
  • Electroluminescent(EL) devices based on organic materials have been of great interest due to their possible applications for large-area flat-panel displays. They are attractive because of their capability of multi-color emission, and low operation voltage. An approach to realize such device characteristics is to use active layers of lanthanide complexes with their inherent extremely sharp emission bands in stead of commonly known organic dyes. In general, organic molecular compounds show emission due to their $\pi$-$\pi*$ transitions resulting in luminescence bandwidths of about 80 to 100nm. Spin statistic estimations lead to an internal quantum efficiency of dye-based EL devices limited to 25%. On the contrary, the fluorescence of lanthanide complexes is based on an intramolecular energy transfer from the triplet of the organic ligand to the 4f energy states of the ion. Therefore, theoretical internal quantum efficiency is principally not limited. In this study, Powders of TPD, $Eu(TTA)_3(phen) and AlQ_3$ in a boat were subsequently heated to their sublimation temperatures to obtain the growth rates of 0.2~0.3nm/s. Organic electrolumnescent devices(OELD) with a structure of $glass substrate/ITO/Eu(TTA)_3(phen)/AI, glass substrate/ITO/TPD/Eu(TTA)_3(phen)/AI and glass substrate/ITO/TPD/Eu(TTA)_3(phen)/AIQ_3AI$ structures were fabricated by vacuum evaporation method, where aromatic diamine(TPD) was used as a hole transporting material, $Eu(TTA)_3(phen)$ as an emitting material, and Tris(8-hydroxyquinoline)Aluminum$(AlQ_3)$ as an electron transporting layer. Electroluminescent(EL) and current density-voltage(J-V) characteristics of these OELDs with various thickness of $Eu(TTA)_3(phen)$ layer were investigated. The triple-layer structure devices show the red EL spectrum at the wavelength of 613nm, which is almost the same as the photoluminescent(PL) spectrum of $Eu(TTA)_3(phen)$.It was found from the J-V characteristics of these devices that the current density is not dependent on the applied field, but on the electric field.

  • PDF

Amperometric Determination of Anthracycline Antibiotics with the Mercury Film Thin Layer Flow Cell (수은피막 박막흐름전지를 이용한 Anthracycline계 항생제의 전류법 정량)

  • Kim, Kyung Eun;Hahn, Younghee
    • Analytical Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.470-475
    • /
    • 2004
  • The mercury film thin layer flow cell (MFTLFC) which yielded the highest sensitivity for the electrochemical reduction of doxorubicin was constructed by coating the glassy carbon working electrode (GCE; $A=0.208cm^2$) with $5{\mu}L$ of HgO coating solution (0.5% HgO + 0.25% polystyrene/cyclohexanone) and subsequently followed by applying a potential of -0.40 V for 300 sec in the flow stream of an acetate buffer of pH 4.5. The voltammogram of doxorubicin reached the diffusion current plateau at -0.53 V vs. a Ag/AgCl (3 M NaCl) in the MFTLFC. The diffusion current (Id) of doxorubicin at the MFTLFC was 1.7 times greater than the Id obtained at the TLFC employing a bare glassy carbon working electrode. When the peak areas (electric charge) were plotted vs. concentrations of standard anthracyclines, the calibration factors of doxorubicin and daunorubicin were $1.12{\times}10^8{\mu}C/M$ (coefficient of determination; $R^2$: 0.969) and $0.98{\times}10^8{\mu}C/M$> ($R^2$: 0.999), respectively in the concentration range between $1.0{\times}10^{-8}M$ and $1.0{\times}10^{-6}M$.

Effects of Immobilized Bipolar Interface Formed by Multivalent and Large Molecular Ions on Electrodialytic Water Splitting at Cation-Exchange Membrane Surface (양이온교환막 표면의 전기투석 물분해에서 다가의 큰 이온성분자에 의해 형성된 고정층 바이폴라 계면의 영향)

  • Seung-Hyeon Moon;Moon-Sung Kang;Yong-Jin Choi
    • Membrane Journal
    • /
    • v.13 no.3
    • /
    • pp.143-153
    • /
    • 2003
  • The effects of bipolar interface formed on the surface of cation-exchange membrane on water splitting phenomena were investigated. Results showed that the formation of immobilized bipolar interface resulted in significant water splitting during electrodialysis. In particular, the immobilized bipolar interface was easily created on the cation-exchange membrane surface in the electrodialytic systems where multivalent cations served as an electrolyte. Multivalent cations with low solubility product resulted in violent water splitting because they were easily precipitated on the membrane surface in hydroxide form. Therefore, the bipolar interface consisting of H- and OH-affinity groups were formed on the membrane-solution interface. Apparently, water splitting was largely activated with the help of strong electric fields generated between the metal hydroxide layer and fixed charge groups on the membrane surface. Likewise, the accumulation of large molecular counter ions on the membrane surface led to the formation of a fixed bipolar structure that could cause significant water splitting in the over-limiting current region. Therefore, the prevention of the immobilization of bipolar interface on the membrane surface is very essential in improving the process efficiency in a high-current operation.

Comparative Evaluation of Radioactive Isotope in Concrete by Heavy Ion Particle using Monte Carlo Simulation (몬테카를로 시뮬레이션을 통한 중하전입자의 콘크리트 방사화 비교평가)

  • Bae, Sang-Il;Cho, Yong-In;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.359-365
    • /
    • 2021
  • A heavy particle accelerator is a device that accelerates particles using high energy and is used in various fields such as medical and industrial fields as well as research. However, secondary neutrons and particle fragments are generated by the high-energy particle beam, and among them, the neutrons do not have an electric charge and directly interact with the nucleus to cause radiation of the material. Quantitative evaluation of the radioactive material produced in this way is necessary, but there are many difficulties in actual measurement during or after operation. Therefore, this study compared and evaluated the generated radioactive material in the concrete shield for protons and carbon ions of specific energy by using the simulation code FLUKA. For the evaluation of each energy of proton beam and carbon ion, the reliability of the source term was secured within 2% of the relative error with the data of the NASA Space Radiation Laboratory(NSRL), which is an internationally standardized data. In the evaluation, carbon ions exhibited higher neutron flux than protons. Afterwards, in the evaluation of radioactive materials under actual operating conditions for disposal, a large amount of short-lived beta-decay nuclides occurred immediately after the operation was terminated, and in the case of protons with a high beam speed, more radioactive products were generated than carbon ions. At this time, radionuclides of 44Sc, 3H and 22Na were observed at a high rate. In addition, as the cooling time elapsed, the ratio of long-lived nuclides increased. For nonparticulate radionuclides, 3H, 22Na, and for particulate radionuclides, 44Ti, 55Fe, 60Co, 152Eu, and 154Eu nuclides showed a high ratio. In this study, it is judged that it is possible to use the particle accelerator as basic data for facility maintenance, repair and dismantling through the prediction of radioactive materials in concrete according to the cooling time after operation and termination of operation.

The Power Converter Circuit Characteristics for 3 kW Wireless Power Transmission (3 kW 무선 전력전송을 위한 전력 변환기 회로 특성)

  • Hwang, Lark-Hoon;Na, Seung-kwon;Kim, Jin Sun;Kang, Jin-hee
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.6
    • /
    • pp.566-572
    • /
    • 2020
  • In a wireless power transmitter, the characteristics and effects of wireless power transmission between two induction coils are investigated, and a power converter circuit and a battery charger/discharger circuit using wireless power transmission technology are proposed. The advantage of wireless power transmitters and wireless chargers is that, instead of the existing plug-in-mounted wired charger (OBC; on-board charger), the user can wirelessly charge the battery without connecting the power source when charging power to the battery. There is. In addition, the advantage of wireless charging can bring about an energy efficiency improvement effect by using the secondary side rectifier circuit and the receiving coil, but the large-capacity long-distance wireless charging method has a limitation on the transmission distance, so many studies are currently being conducted. The purpose of the study is to study the transmitter circuit and receiver circuit of a wireless power transmission device using a primary coil, a secondary coil, and a half bridge series resonance converter, which can transmit power of a non-contact type power transmitter. As a result, a new topology was applied to improve the power transmission distance of the wireless charging system, and through an experiment according to each distance, the maximum efficiency (95.8%) was confirmed at an output of 3 kW at an 8 cm transmission distance.

The Study on Control Algorithm of Elevator EDLC Emergency Power Converter (승강기 EDLC 비상전원 전력변환장치 제어 알고리즘 연구)

  • Lee, Sang-min;Kim, IL-Song;Kim, Nam
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.6
    • /
    • pp.709-718
    • /
    • 2017
  • The installation of the elevator ARD(Automatic Rescue Device) system has been forced into law in these days in order to safely rescue passengers during power failure. The configuration of the ARD system consists of energy storage device, power converter and control systems. The EDLC(Electric Double Layer Capacitor) are used as energy storage device for rapid charge/discharge purposes. The power conditioning system (PCS) consists of bi-directional converter, 3-phase converter and control system. The dead-beat control system is adopted for most systems however it requires complex mathematical calculations, the high performance microprocessors are mandatory and thus it can be a cause of high manufacturing cost. In this paper the new control method for average current mode control is presented for simple structure. The control algorithm is applied to the single phase system and then expands to three phase system to meet the sysem requirements. The mathematical modeling using average modeling method is presented and analysed by PSIM computer simulation to verifie the validity of the proposed control methods.

Monovalent Ion Selective Anion-Exchange Membranes for Reverse Electrodialysis Application (역전기투석 응용을 위한 1가 이온 선택성 음이온교환막)

  • Ji-Hyeon Lee;Moon-Sung Kang
    • Membrane Journal
    • /
    • v.34 no.1
    • /
    • pp.58-69
    • /
    • 2024
  • Reverse electrodialysis (RED) is an electro-membrane process employing ion-exchange membranes (IEMs) that can harvest electric energy from the concentration difference between seawater and river water. Multivalent ions contained in seawater and river water bind strongly to the fixed charge groups of the IEM, causing high resistance and reducing open-circuit voltage and power density through uphill transport. In this study, a pore-filled anion-exchange membrane (PFAEM) with excellent monovalent ion selectivity and electrochemical properties was fabricated and characterized for RED application. The monovalent ion selectivity of the prepared membrane was 3.65, which was superior to a commercial membrane (ASE, Astom Corp.) with a selectivity of 1.27 under the same conditions. Additionally, the prepared membrane showed excellent electrochemical properties, including low electrical resistance compared to ASE. As a result of evaluating RED performance under seawater of 0.459 M NaCl/0.0510 M Na2SO4 and river water of 0.0153 M NaCl/0.0017 M Na2SO4, the maximum power density of 1.80 W/m2 was obtained by applying the prepared membrane, which is a 40.6% improved output performance compared to the ASE membrane.

Efficiency Estimation for Desalination System of Seawater Using Reverse Osmosis Membrane (역삼투압막 해수담수화 장치의 미네럴 분리 성능평가)

  • Moon, Deok-Soo;Jung, Dong-Ho;Kim, Hyeon-Ju;Shin, Phil-Kwon
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.8 no.2
    • /
    • pp.60-66
    • /
    • 2005
  • When external pressure higher than osmosis pressure is reversely derived into solution, its solvent is moved into the solution having lower concentration, which is called 'reverse osmosis'. We investigated the desalination application of deep ocean water using reverse osmosis pressure of $40-70\;kgf/cm^2$ We observed how to operational factor j like flow rate, water temperature and pressure have effect on efficiency of reverse osmosis membrane and salts rejection. Fluxes of reverse osmosis membrane are directly proportional to water temperature and pressure. However, salts rejection rates are positively correlated with pressure and inversely proportional to water temperature. Separation efficiencies of osmosis membrane for major elements such as $Mg^{2+},\;Ca^{+2},\;Na^+\;and\;K^+$ are as follows in a strong electrolysis solution like seawater; $Ca^{2+},\;Mg^{2+}>K^+>Na^+$. Rejection rates of $Mg^{2+}\;and\;Ca^{2+}$ that have high electric charges are over 99% and show positively correlation with water temperature. Rejection rates of $Na^+$ having low electric charge is observed to be 98%-99%, which rates is much lower than those of $2^+$ charged ions like $Ca^{2+}\;and\;Mg^{2+}$. Ion rejection rates of boron, B, are much low because boron is present il free state or gas phase in seawater. Boron concentration in desalination water is over criteria of Korean drinking water, 0.3 mg/L. However, we could satisfied with the criteria of drinking water under the operation condition like temperature $5^{\circ}C$ and pressure $70kgf/cm^2$, using the relationship that rejection rates of boron is proportional to pressure and is inversely proportional to water temperature

  • PDF

Study on Safety Management Activity of Blood Test Room of Nuclear Medicine Department (핵의학과 혈액검사실의 안전 관리 활동에 대한 고찰)

  • Sim, Seong-Jae;Shin, Young-Kyun;Moon, Hyeong-Ho;Yoo, Seon-Hee;Jo, Shi-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.104-110
    • /
    • 2011
  • Purpose: The object evaluation method about medical institutes of these days increases credibility of consumers about medical services by conducting a certification system about medical institutes. In addition, as nuclear medicine test rooms and diagnosis test medicine room adopt many kinds of international certification systems, the matters regarding safety management of test rooms are being regarded as important. Since the blood test rooms of nuclear medicine are exposed to many harmful factors such as infection from clinical specimen and radioactive isotope reagent, there is a need to pay lots of attention to the safety management of staff and patients. Therefore, this study discusses safety management activities of staff and patients, which are conducted in the blood test rooms of the nuclear medicine department in Asan Medical Center. Materials and Methods: In the blood test rooms of the nuclear medicine department in Asan Medical Center, the matters regarding comprehensive safety management by the person in charge of safety management are offered and all staff members of the test rooms apply them into work. Safety management education is regularly conducted according to established regulations, and infection is prevented through implementation of wearing personal protectors and hand sanitation during test work. In addition, technical safety guides and accident guides for interruption of electric power are provided against emergencies. Through infection management guides, infection prevention and preparation methods for infection are learned and radioactive isotope management, safety management about reagent use and safety guides about harmful chemical substances are being applied to work. Results: The blood test rooms of the nuclear medicine department apply safety management regulations to work. Under the situation where hand sanitation should be conducted, hands are washed to prevent infection between staff and patients, and for preventing infection from clinical specimen, personal protectors are worn. The reagent, which is classified as harmful substance, is separately stored to be easily recognized, radioactive wastes and general medical wastes are also safely managed. Through these lots of safety management activities, safety management awareness of staff members is enhanced, and patients are protected from many dangers. Conclusion: Staff members of the blood test rooms of the nuclear medicine department should be fully aware of safety management regulations and apply them to work. When better safety management suggestions are made, they need to be examined and applied for increasing quality of safety management for staff and patients.

  • PDF