• Title/Summary/Keyword: Electric Appliance

Search Result 143, Processing Time 0.032 seconds

Numerical analysis of electromagnetic fields in Korean High Speed Train by transmission line matrix method (TLM 방법을 이용한 한국형 고속열차내의 전자계 해석)

  • Han, In-Su;Han, Young-Jae;Lee, Tae-Hyung;Park, Choon-Soo;Kim, Ki-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.466-469
    • /
    • 2008
  • As the industry develops, they are interested in the fault of electric machines and the effect on human beings by electromagnetic fields and waves which generate through much use of electric machines and appliances. In foreign country, they confirmed the standard about electromagnetic interference and compatibility(EMI/EMC) of electromagnetic fields and waves generating electricity transmission/distribution equipments and electric appliance. In Korea, such criteria are applied too. Before EMI/EMC standard is applied, it is important to prepare the plan to predict and reduce electromagnetic fields and waves which generate in the inner and the outer part of electric machinery. To solve such a problem, they calculated Maxwell's equations by finite element method(FEM) and finite difference method(FDM) in most papers. However, these methods have the disadvantage that mathematical expansions are complex and need much memory allocations for grid and mesh generations. In this paper, we introduce transmission line matrix(TLM) method that media of which trains consists are regarded as transmission lines for electromagnetic field calculation in Korean High Speed Train, calculate the electric and magnetic field, and analyze the results.

  • PDF

State-of-the-Art of Low Cost Motor Drives (저가형 모터 드라이브 기술동향)

  • Lee B.K.;Kim J.S.;Rim G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.451-454
    • /
    • 2003
  • In this paper, the research trend and the sate-of-the-art of low cost motor drives are introduced with the recently increasing interest In various industrial applications, such as home appliance, hybrid electric vehicles, wind power systems, fuel cell systems, and etc. Based on this presented work, it is highly expected the power electronics technologies, which are accumulated through the last 20 years, can be effectively applied to actual application fields.

  • PDF

Development of supersaving electric power chip for intelligent appliance (정보가전기기 전력저감용 초절전 전원칩 개발)

  • Kim, Chan;Jeon, Eui-Seok;Jo, Kyoung-Sook
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.894-895
    • /
    • 2008
  • 정보가전기기의 전력저감을 위한 기술개발로서 Home-net 기반 지능형 초절전 전원기술 개발을 목표로 하며, 관련 설계기술 및 내부블록을 설계하여 초절전 전원칩을 제작하고, 지능형 SMPS를 위한 digital control IC와 연결하여 동작 특성을 평가한다.

  • PDF

Pulse Density Modulated Zero Voltage Soft-Switching High-Frequency Inverter with Single Switch for Xenon Gas Dielectric Barrier Discharge Lamp Dimming

  • Sugimura, Hisayuki;Suh, Ki-Young;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.391-394
    • /
    • 2006
  • This paper presents soft switching zero voltage switching high frequency inverter for rare gas fluorescent lamp using dielectric-barrier discharge phenomenon. The simple high-frequency inverter can completely achieve stable zero voltage soft switching (ZVS) commutation for wide its output power regulation ranges and load variations under its constant high frequency pulse density modulation (PDM) scheme. Its transient and steady state operating principle is originally described and discussed for a constant high-frequency PDM control strategy under a stable ZVS operation commutation, together with its output effective power regulation characteristics-based on the high frequency PDM strategy. The experimental operating performances of this high frequency Inverter are illustrated as compared with computer simulation results and experimental ones. Its light dimming characteristics due to power regulation scheme are evaluated and discussed on the basis of simulation and experimental results. The feasible effectiveness of this high frequency inverter appliance implemented here is proven from the practical point of view.

  • PDF

A Study on the Establishment of Preventive Measures for Electric Fires Using the 4M Technique (4M 기법을 활용한 전기화재 예방대책 수립 연구)

  • Oh, Teakhum;Park, Chanseok
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.4
    • /
    • pp.23-29
    • /
    • 2021
  • The purpose of this study is to reduce the probability of occurrence of electric fires as a preemptive preventive measure, and to strengthen the capability of preventing electric fires by strengthening the cooperative function between electric fire-related departments and establishing a cooperative system. In this study, the general aspects of electric fires were identified by reviewing the literature such as ignition mechanisms of electric fires. And the major electrical fires that occurred in the last 10 years were classified into ignition factors (short circuit, overload/overcurrent, and earth leakage/ground fault) and ignition sources (wiring/wiring appliances, electrical equipment/household appliances). And the 4M technique was used to analyze the potential causes of ignition at the fire site and to suggest preventive measures. In the case In this study, out of 48 electrical fires in the past 10 years, 16 short-circuit fires, 3 overload/overcurrent fires, 3 short-circuit and earth fault fires, 16 fires in wiring/wiring appliances, and 10 fires in electrical equipment/home appliances classified as cases. And prevention measures were presented in terms of human, machine, media, and management by using the 4M technique. For the preemptive prevention of electric fires, strengthening the compulsory electrical safety inspection and making it mandatory to report when new or expanding electric facilities, charging a fee for electric safety inspection for detached houses and granting benefits subject to inspection completion, improvement of the electric safety voluntary inspection table and safety indications; It was suggested as a policy to organize and operate electrical safety inspection personnel in a two-person team (mixed), establish a close work cooperation system with related organizations, and strengthen electrical safety education and publicity.

Research about environment and change of style influenced upon the black and white TV (흑백TV 시대에 영향을 미친 환경 및 스타일 변화에 관한 연구)

  • Shin, Myung-Chul
    • Archives of design research
    • /
    • v.17 no.4
    • /
    • pp.5-14
    • /
    • 2004
  • Black and white TV design process at early electronics industry can help greatly in strategy of forward product development or production and marketing. Because, there is history about existed all product to precess that progress. Past information make good use that estimate of new design. According to character of product, advertisement and business strategies are available some extension of life cycle or preservation. But, it is need the data accumulated with correct analysis for ability that competitive power of the product. Data of Past information take advantage of well information is essential. Information about past products arranged pamphlet and newspaper advertisement. At this study emphasized on console model TV and portable style TV design change process of technology ability from 1960s to 1980s about product selling point. Creation and extinction about products can get into iteration to other household electric appliance. Design process of past product design has a history with our international location or influence power of household electric appliance. Therefore, such past flowing can important role as basis of forward product design.

  • PDF

A Study on Flow Characteristics of ERF Between Two Parallel-Plate by Using PlV (평형평판 간극사이에서 PIV를 이용한 ER유체의 유동특성에 관한연구)

  • Jung Wan-Bo;Park Young-Seuk
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.1
    • /
    • pp.56-62
    • /
    • 2006
  • An experimental investigation was performed to study the characteristics of ER(Electro-Rheological) fluid flow in a horizontal rectangular tube with or without D.C voltage. To determine some characteristics of the ER flow, 2D PIV(Particle Image Velocimetry) technique is employed for velocity measurement. This research found the mean velocity distribution with 0kV/mm, 1.0kV/mm and 1.5kV/mm for Re = 0, 0.62, 1.29 and 2.26. When the strength of the electric field increased, the cluster of ERF are clearly strong along the test tube and the flow rate decreased. In this study, the rheology of ER fluid stagnating or flowing through a dispersion meter will be investigated by PIV method. And then the ER effect, which appears at the ER valves and their appliance will be visualized.

Design of Cap Inspection Algorithm of Fuse Cap (퓨즈 캡의 검사를 위한 알고리즘 설계)

  • Ban, Gi-Jong;Won, Young-Jin;Lim, Seung-Ha
    • 전자공학회논문지 IE
    • /
    • v.47 no.4
    • /
    • pp.28-33
    • /
    • 2010
  • In this paper, we proposed to the inspection algorithm for cap, Electric fuse is an over current and circuit protection device which is occurred in electric & electronic appliance. Also the fuse are protection the second hazard at arc etc. Fuse are interest regarding a safety increased. Consequently, the fuse came to be very important. Cap inspection algorithm is designed for the cap of fuse. CCD camera is monitering the solder of cap distribution map. The conditioning of fuse cap; suming all searching data with non solder area. the area is bigger reference data then the cap is bad cap.

A Study on Authoritativeness of Electric Fire by Activating of Fire Damaged MCCB (소손된 배선용 차단기 동작상태에 의한 전기화재 규명의 신뢰성에 관한 연구)

  • Lee, Jong-Hwa;Mun, Yong-Soo;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.2
    • /
    • pp.87-94
    • /
    • 2009
  • In the fire there are fusion signs and damage by fire, and insulation aging and carbonization of the electric wiring in the ignition spot because of special characteristic of the appliance in the electricity fire. Because of the physical factor applied in the damage of fire, the decision of ignition spot by eye investigation is insufficient. In this paper, the cause of electricity fire is researched. The focus is on the operation state of operated MCCB(Molded Case Circuit Breaker) at the time of electricity fire. Through grasping the operation principle of MCCB and the experiment, the state of MCCB after fire suppression is discriminated. The distinction possibility on the exist of electricity fire is proposed.