• Title/Summary/Keyword: Electic Power

Search Result 10, Processing Time 0.023 seconds

Power Management System Simulator Modeling and Characteristics Analysis for Electric Propulsion Ship (LNGC용 Power Management System 시뮬레이터 모델링 및 특성분석)

  • Kim, Youngmin;Jeon, Kyung-Won;Jung, Sang-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.6
    • /
    • pp.878-884
    • /
    • 2015
  • In this paper, Power Management System(PMS) simulator for Liquid Nature Gas Carrier(LNGC) is developed. Major components of power system for LNGC, such as generator, diesel engine and governor, transformer, circuit breaker, and 3 phase loads models are built based on MATLAB/SIMULINK. With these designed major parts, PMS simulator modeling is carried out. Based on MATLAB/Graphical User Interface, PMS simulator control for LNGC, and Human Machine Interface for monitoring is designed. PMS simulator for LNGC carries out simulation according to sequence of characteristics analysis. By comparing results of predicted simulation for each sequence to that of characteristics analysis, the reliability of PMS simulator for LNGC will be verified.

Electric Field Distribution Simulation of the Cable Joint Materials (케이블 접속재료의 전계분포 시뮬레이션)

  • Kim, Hyung-Joo;Byun, Doo-Gyoon;Shin, Jong-Yeol;Lee, Duk-Jin;Lee, Chung-Ho;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.601-604
    • /
    • 2001
  • The insulation materials of cables used for underground power transmission requires a higher insulating capability. and the most popular method to examine the cable is partial discharge test due to applying variation voltage. In the thesis. air void. silicone oil. of which may possibly exist real cables. are simulated by Electra 2D program. Also the relations between calculated field strength and the void defect type in the cable joint materails. In the modeling. electic field inner to the cable joint material composed by XLPE and EPDM is modeling simulated. We obtained the electric field distribution in void due to two conditions.

  • PDF

An Optimization of Ordering Algorithm for Sparse Vector Method (스파스벡터법을 위한 서열산법의 최적화)

  • Shin, Myong-Chul;Lee, Chun-Mo
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.189-194
    • /
    • 1989
  • The sparse vector method is more efficient than conventional sparse matrix method when solving sparse system. This paper considers the structural relation between factorized L and inverse of L and presents a new ordering algorithm for sparse vector method. The method is useful in enhancing the sparsity of the inverse of L while preserving the aparsity of matrix. The performance of algorithm is compared with conventional algorithms by means of several power system.

  • PDF

Design of control system for for automobile clutch (자동차 클러치에 대한 제어시스템의 설계)

  • 안양기;윤동한
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.487-490
    • /
    • 1998
  • During driving an automobile, drivers push the clutch and transmit gear by their feeling. At the automobile which have the manually operated gear box by using apart designed equipment, for get the semi-auto function, a lot of research to realize the system which have passive transmission and automotive transmission has developed. In this paper, basically using one chip .mu.-comcontrolled the clutch of automobile by means of LPF, F/V converter and TR driver circuit which is designed. In the past, it was controlled the motor by operating relay which is int eh output system to control the clutch. This system some noises is made by on and off the relay, lessen the motor speed and causes many error due to consume the large power on driving the motor. In this paper, to solve these problems the output TR is operated by using one chip .mu.-com decrease the electic power consumption and designed the actuator to control the clutch by measns of vacuum.

  • PDF

DC-DC Converter for Integrated Voltage Control Method (전압 적분 제어법에 의한 DC-DC 컨버터)

  • 이현우;서기영
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.10
    • /
    • pp.1590-1597
    • /
    • 1993
  • Power conversion system generally requires bidirectional converter. A storage energy of reactor is suppressed by regeneration of surplus electic energy in converter to power source. When an electric isolation in the power conversion system is required. the most suitable position for the isolation is the DC-Link part. A transformer in the DC part is minimized because of high repetition frequency. This paper proposes that power conversion system becomes bidirectional DC-DC converter with electric isolation by intergrated voltage control method. It is intergrated voltage control that makes system construciton simple, has control errow little quantity ans gets output response Quick. And the power-switches which should be operated is selected automatically without a detection of the current-direction.

  • PDF

The development of 25kW Battery Charger for Electic Railway Vehicles. (철도차량용 25kW급 배터리 충전기 개발.)

  • Shin, H.K.;Choi, S.H.;Hong, C.H.;Jin, Y.S.;Jho, K.Y.;Kim, H.G.
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.139-140
    • /
    • 2013
  • 본 논문에서는 철도차량용 25kW급 배터리 충전기 개발에 대해 설명한다. 열차 판넬 및 제어용 전원으로 사용되는 배터리 전원을 사용한다. 이를 상시 충전하기 위한 충전기는 기존에 보조전원장치의 3상 380V를 받아 강압 변압기를 사용하여 다이오드 정류 혹은 싸이리스터를 사용하였다. 하지만, 기존방식은 강압 변압기가 60Hz의 낮은 주파수로 인하여 사이즈 및 중량 증대를 유발 한다. 이에 본 논문에서는 가선의 높은 전압을 받아 공진형 컨버터를 사용하여 주파수를 높여 변압기의 사이즈 및 중량을 감소 하였으며, 안정적인 전원을 공급 하는 배터리 충전기를 개발 하였다. 이를 25kW급 시제품에 대한 시뮬레이션을 통해 입증 하였다.

  • PDF

Effect of NaCl Treatment and Gamma Ray Irradiation on the Induction Pink Mutations in Hairs of Tradescantia Stamen (NaCl 처리와 감마선조사가 자주달개비 수술털 세포의 분홍돌연변이 유기에 미치는 영향)

  • Kim, Jin-Kyu;Kim, Won-Rok;Kim, Jae-Sung;Kim, Ki-Nam;Hong, Kwang-Phyo
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.1
    • /
    • pp.41-47
    • /
    • 1999
  • To investigate the combined effect of gamma ray irradiation and NaCl treatment on Tradescantia somatic cell pink mutations, potted plants of Tradescantia 4430 were evenly sprayed with NaCl solution(170mM) 24 hours before irradiation(NaCl+${\gamma}$) and after irradiation(${\gamma}$+NaCl). Irradiation doses were 0.3, 0.5, 1.0 and 2.0 Gy of gamma-ray. The plants irradiated only with gamma radiation were used as control group(CT). Frequency of pink mutation increased linearly with irradiation close and the peak interval of elevated mutation frequencies appeared during 6∼12 days aver irradiation in all the experimental groups. The slope of dose-response curve in CT was 5.99($r^2$=0.99), while it were 4.55($r^2$=0.98) in NaCl+${\gamma}$ and 4.33($r^2$=0.99) in ${\gamma}$+NaCl. It seemed that pre- and post-treatment of NaCl had a protective effect it against radiation-induced cell damages since it decreased the slope value by more than 24%. It is suggested that protective effect on DNA damages can be invoked in irradiated stamen hair cells by NaCl treatment.

  • PDF

The Individual Heat-recovery ventilation system of Residential Buildings (주거용 건물의 개별 환기시스템 필요성에 관한 연구)

  • Shin, U-Cheul;Lee, Wang-Je;Yoon, Jong-Ho;Baek, Nam-Choon
    • KIEAE Journal
    • /
    • v.14 no.6
    • /
    • pp.99-104
    • /
    • 2014
  • Recently supply of low energy house is increasing which can enhance energy efficiency and indoor environment comfort. Low energy house have to secure air tightness as well as thermal performance so house become high airtightness and inevitably need heat recovery ventilator to enhance indoor air quality. However, most of current ventilation systems are one-click, controlling the entire space so it causes increasing of heating load and fan power which makes it hard to save energy. Thus, Individual Control system is required which can achieve both enhancing indoor air quality and decreasing heating load and electric fan power. Thereby, in this study, we analyzed the correlation between ventilation and fan power through mock-up experiment and measured ventilation load under individual control system. As a result, under the condition of $24^{\circ}C$ of indoor temperature for 6 month(November to April) in Daejeon, ventilation load by fan speed was $10.9{\sim}19.6kWh/m^2{\cdot}a$ when operated 24 hours and $7.6{\sim}13.7kWh/m^2{\cdot}a$ when operated 12 hours in night time. In addition, it is possible to reduce at most 60% of ventilation load under the individual control system; measured ventilation load was $7.4kWh/m^2{\cdot}a$ when operated 24 hours, and $5.5kWh/m^2{\cdot}$ when operated 12 hours in night time.

A theoretical study on Determinants of National Competitive Advantage (산업의 국제경쟁력 결정요인에 관한 이론적 관찰)

  • 이학헌;민성규
    • Journal of the Korean Institute of Navigation
    • /
    • v.19 no.1
    • /
    • pp.49-69
    • /
    • 1995
  • What is the national competitive power\ulcorner What are the determinants of national competitive advantage\ulcorner In order to find these problems, this study was initiated theoretically through the international trade theory and international managerial strategic theory. The flow of studies, in connection with these competitive advantage, come into industries competitive advantage from national competitive advantage. It is understood that the flow of studies is based on the change of paradigm about the international industry environment. Today, the international industry environment has been changed into vigorous situation with the new trade system such as globalization, UR negotiation, WTO system instead of GATT. Among these environments, all enterprises in any industries should try to enhance their benefit, income profits and develop their management strategy, because it is essential for them to keep and make a profit in order to be competitive against all other rivaling enterprises. According to researchers and the ages of history, the concept and determinants of competitive advantage have been dissimiliar as followings. 1) Theory of absolute advantage : Absolute Product Cost. 2) Theory of comparative advantage : Comparative Product Cost. 3) Theory of reciprocal demand : the Reciprocal Demand Structure. 4) Theory of Hechsher-Ohlin : Factor Endowment. 5) Paradox of Leontief : the Quality of Factor Endowment. 6) Theory of technological gap : R & D. 7) Technological gap model : The Technological Gap. 8) Theory of the product life cycle : Product Life Cycle. 9) Christensen's study : Firm's character & manager's character. 10) Monopolistic Advantage Theories : Monopolistic Advantage 11) Electic theory : Ownership, location and internalization specific advantages. 12) Theory of value chain : Cost advantage, Differentiation, Focus. However all these theories have the limit of illustration regarding today's competitive situation, the Porter's theory shows well the determinants of competitive advantage with competitive strategy. Therefore, the analysis of the competitive advantage for maritime industry should be studied by the determinants of competitive advantage of nations

  • PDF

Triboelectrostatic Separation of Unburned Carbon from Flyash for Ash Recycling (마찰대전 정전분리기를 이용하여 석탄회에 함유된 미연탄소분 제거에 관한 연구)

  • 이재근;김성찬;손낙원;김두현;오정근
    • Resources Recycling
    • /
    • v.6 no.3
    • /
    • pp.15-21
    • /
    • 1997
  • Flyash from a coal-hed power plan1 is produced approximtcly 3 million tons m 1996 and causes the serious environmentalpmblem due to the disposal in the ash pond. Flyash is an accepted additive in concrete where it adds strength, sulfate ateresistanceand reduced cost, provided acccptablc levcls of unbunrned carbon are mmtmed This papzr describes to investigate thc technicalfeasibility of a dry triboelcctrostatlcp roccss to scparate unburned carbon h m f lyash into economically valuable produck Puliclesof unburned carbon and flyash can be impded positivc and negative surface charzes. rcapeclively. with a copper tniochargcr dueto dirferences in the work function values of thc particles and the tnbacharger. and cm he separated by passing thcm throuph anexternal electic field. A laboratory s d e separation system consists of r sacw feeder for ash supply, a tniocharger, verticalcollecling copper plates, power supplies, a flow meter, and a fan. Separation tests taking into account separahian efficiency and ashrecovery showed that flyash recovery was sh-nngly dependent an thc tnbocharger geomzhy, elect"c ficld strength. flyssh s ~ c a,n dash feeding late. Optimal separation conditions were flyash size less than 125 Fm and electric field shcngrh of 200 kV1m. Ovcr 80%of the flyash with 7% lass on ignition was recovered at wrbon contznts less than 3%bon contznts less than 3%

  • PDF