• 제목/요약/키워드: Elastic Surrounding Tissue

검색결과 9건 처리시간 0.032초

Histological observations of age-related changes in the epiglottis associated with decreased deglutition function in older adults

  • Masamitsu Serikawa;Kimiharu Ambe;Akinobu Usami
    • Anatomy and Cell Biology
    • /
    • 제56권3호
    • /
    • pp.374-381
    • /
    • 2023
  • Although the epiglottis plays a vital role in deglutition, histological studies of the epiglottis and surrounding ligaments associated with swallowing dysfunction are limited. Therefore, we performed histological observations to clarify age-related changes in the morphological characteristics of the epiglottis and surrounding structures. Tissue samples comprising the epiglottis and surrounding structures were collected from corpses that were both orally fed and tubefed during their lifetimes. Following hematoxylin and eosin, Elastica Van Gieson, and immunohistochemical staining procedures, the chondrocytes, connective tissue, and glandular tissue were observed under the epiglottis epithelium, and intervening adipose tissue was observed in the surrounding area. Fatty degeneration of acinar cells was also observed in the glandular tissue, possibly because of aging. Bundles of elastic fibers were present around the vascular wall in the peri-epiglottic ligament, but some were reduced. Furthermore, large amounts of collagen fibers ran toward and through the cartilage, whereas the mesh-like elastic fibers stopped in front of the cartilage. Microfibrils considered to be oxytalan fibers, which are thinner and shorter than elastic fibers, were observed around the vascular wall and in the fiber bundles. Age-related changes included connective tissue fibrosis shown by the large amount of collagen fibers, atrophy of salivary glands, and an accompanying increase in adipose tissue. Regarding stretchability and elasticity, the elastic fibers may have an auxiliary function for laryngeal elevation during deglutition. This suggests that disuse atrophy of the laryngeal organs with or without oral intake might reduce the amount of elastic fiber in older adults.

탄성경계조직을 가진 관상동맥의 end-to-end 문합에 대한 유한요소해석 (Finite Element Analysis of End-to-End Anastomosis of Coronary Artery with Elastic Surrounding Tissue)

  • 한근조;김태형;안성찬;심재준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.442-447
    • /
    • 2001
  • A finite element analysis of end-to-end artery/PTFE anastomosis has been presented in this study to evaluate the distribution of compliance in the vicinity of the anastomosis due to any mismatch in compliance characteristics. But, In these studies it was assumed that the artery and PTFE have the simple cylindrical shape representing the fatty tissue surrounding the coronary artery. And the fatty tissue was considered as the elastic surrounding materials in the finite element analysis. The simulation results were obtained as follows : 1. A fatty tissue was effect to reduce the compliance mismatch in the vicinity of a artery/PTFE anastomosis of different material because a hypercompliant zone become narrorw and a compliance discrepancy decrease between the artery and the PTFE about 70%. And radial direction displacement distribution with respect to distance in the vicinity of a artery/PTFE anastomosis was similiar. 2. The variation of PTFE thckness reduce the compliance mismatch in the vicinity of a artery/PTFE anastomosis about 25%.

  • PDF

단순봉합모델을 이용한 문합에서 탄성경계층의 두께 변화에 따른 기계역학적 거동에 관한 연구 (The Study on the Mechanical Behavior of the Anastomosis with respect to the Thickness Variation of Elastic Foundation Using Simplified Suturing Model)

  • 이성욱;한근조;심재준;한동섭;김태형
    • 한국정밀공학회지
    • /
    • 제21권8호
    • /
    • pp.188-195
    • /
    • 2004
  • In this paper we analyzed the mechanical behavior with respect to the thickness variation of elastic foundation(fatty tissue) in end-to-end anastomosis. This study considered the preliminary deformed shape induced by suturing in the anastomosis of coronary artery and PTFE with different diameters using simplified suturing model and the fatty tissue surrounding heart and coronary artery for more accurate result using finite element method. Area compliance(CA) was used to analyze the final deformed shape of the anastomotic part with respect to the thickness variation of fatty tissue under mean blood pressure, 100mmHg(13.3㎪). And Equivalent and circumferential stresses in the anastomosis were also analyzed with respect to the change of initial diameter ratio( $R_1$) and fatty tissue thickness( $T_{F}$). The results obtained were as follows : 1 When the elastic foundation, assumed to be incompressive material, surrounded the grafts in anastomosis, the compliance mismatch of artery and PTFE was reduced by 47 -72%. 2. As the initial diameter ratio( $R_1$) became larger, the higher difference of compliance was induced in spite of elastic foundation surrounding grafts. 3. The maximum nondimensional circumferential stress is twice or three times as high as the maximum nondimensional equivalent stress in the anastomotic part.t.

단순봉합모델을 이용한 문합에서 탄성경계층의 두께 변화에 따른 컴플라이언스 부적합에 관한 연구 (The Study on Compliance Mismatch with respect to the Thickness Variation of Elastic Foundation in Anastomosis Using Simplified Suturing Model)

  • 이성욱;심재준;한동섭;한근조;김태형
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1302-1305
    • /
    • 2003
  • In this paper we analyzed the effect of compliance mismatch with respect to the thickness variation of elastic foundation(fatty tissue) in end-to-end anastomosis. This study considered the preliminary deformed shape induced by suturing in the anastomosis of coronary artery and PTFE with different diameters using simplified suturing model and the fatty tissue surrounding heart and coronary artery for more accurate result using finite element method. Area compliance(C$\sub$A/) was used to analyze the final deformed shape of the anastomotic part with respect to the thickness variation of fatty tissue under mean blood pressure, 100 mmHg(13.3kPa). The results obtained were as follows : 1. When the elastic foundation, assumed to be incompressive material, surrounded the grafts in anastomosis, the compliance mismatch of artery and PTFE was improved by 47∼72%. 2. As the initial diameter ratio(R$\sub$I/) became larger, the higher difference of compliance was induced in spite of elastic foundation surrounding grafts.

  • PDF

압축하중시 RPI clasp의 3가지 다른 proximal plate 형태에 따른 지대치 주위조직의 광탄성 응력 분석 (Photoelastic Stress Analysis of the Abutment Surrounding Tissue According to Shape of the Proximal Plate of the RPI Clasp)

  • 최정수;김부섭
    • 대한치과기공학회지
    • /
    • 제34권4호
    • /
    • pp.473-482
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the stress distribution of the surrounding tissues according to 3 proximal plate types of the RPI clasp. Methods: The removeable partial denture which mandibular right and left second premolars and mandibular molars were lost was attached to a three dimensional photo elastic epoxy resin model. Then 120N of vertical load was applied. After 3-dimensional photoelastic stress analysis was used to record the isochromatic fringe patterns. Results: Kratochvil type guiding plane exhibited little uniform stress distribution on load center and alveolar ridge, but higher stress concentration on buccal surface of second premolar. Krol type guiding plane exhibited the stress concentration on the front of load center and relatively higher stress concentration on buccal surface of first premolar. However, this type had no effect on canine. Researcher type guiding plane showed the stress concentration on second premolar and molar, but the little stress distribution on first premolar. Conclusion: In all types, excessive stress concentration was appeared and three types were not significant different.

초음파 탄성 영상 평가를 위한 플라스틱 기반의 팬텀 개발 (Ultrasonic Phantom Based on Plastic Material for Elastography)

  • 안동기;정목근
    • 비파괴검사학회지
    • /
    • 제29권4호
    • /
    • pp.368-373
    • /
    • 2009
  • 초음파 의료용 탄성 영상 시스템의 성능을 평가하기 위한 인체 조직 모사 팬텀을 제작하였다. 인체에서 종양이나 암 조직은 주위의 정상조직보다 단단한 특성을 가진다. 이러한 조직의 단단함을 영상화하는 기법이 탄성 영상 기법이다. 인체의 병변 조직의 기계적인 특성을 모사하기 위하여 플라스틱 경화제와 연화제를 이용하여 탄성도가 다른 균일 탄성 팬텀을 제작하였다. 제작된 균일 탄성 팬텀은 시료의 비율에 따라 $11.1{\sim}79.6$ kPa 범위의 탄성계수 값을 얻었다. 이를 바탕으로 외부 매질과 내부 매질의 탄성계수 차이가 5배와 7배 정도인 초음파 병변 모사 팬텀을 제작하여 탄성 영상을 획득하였다. 본 논문에서는 제작된 플라스틱 기반의 탄성 팬텀이 인체의 탄성 특성을 모사하는 탄성 팬텀으로서 유용함을 확인하였다.

한국의 한의 미용에서 매선요법 치료 기전에 대한 분석 (Analysis of the Mechanism of Thread-Embedding Acupuncture in Korean Medicine Beauty Treatment)

  • 박은영;서형식
    • 한방안이비인후피부과학회지
    • /
    • 제36권4호
    • /
    • pp.113-121
    • /
    • 2023
  • Objectives : The purpose of this study is to analyze the treatment mechanism of Thread-embedding acupuncture, which is used in Korean medicine beauty treatment. Methods : After searching papers published up to January 1, 2023 using the keyword "Thread-embedding" through the OASIS site, we selected beauty papers that mentioned the treatment mechanism of Thread-embedding acupuncture. Results : A total of 60 papers were retrieved: 19 papers on the topic of cosmetic diseases, 35 papers on the theme of other diseases, and 6 papers written unrelated to diseases. Among the 19 papers on the topic of cosmetic diseases, one unreadable paper was excluded. Among the 18 papers, we finally selected 6 papers that mentioned treatment mechanisms: 2 on facial wrinkles, 2 on obesity, 1 on breast enlargement, and 1 on transdermal hydration. The treatment mechanism of Thread-embedding acupuncture is that in the case of facial wrinkles, polydioxanone(PDO) is embedded to fill the volume, and as it decomposes, it causes a tissue reaction around the area. In obesity, it promotes fat decomposition by improving circulation, and promotes breast enlargement and elasticity through collagen formation. In transdermal hydration, it induces the production of surrounding fibers to increase skin elasticity and moisture. Conclusions : Thread-embedding acupuncture appears to have a cosmetic effect through a mechanism that promotes the production of collagen and elastic fibers in the subepidermal dermal layer and increases the activity of skin moisturizing factors during the absorption process after the PDO suture is embedded.

유성견의 소구치 압하시 초기 치아 및 치주 조직의 조직학적 변화와 재생에 관한 연구 (EARLY HISTO(PATHO)LOGIC CHANGES AND RECOVERY OF TOOTH AND PERIODONTAL TISSUE IN INTRUSION OF PREMOLAR ON YOUNG ADULT DOGS)

  • 안병교;차경석;이진우
    • 대한치과교정학회지
    • /
    • 제28권2호
    • /
    • pp.297-310
    • /
    • 1998
  • 치아에 압하력을 elastic chain을 이용하여 지속적으로 교정력을 평균 9개월된 유성견의 소구치에 가한 직후 치아와 그 주위조직에서 일어나는 조직학적인 변화와 압하력을 제거한 후 일정기간이 지난 후 변화되었던 조직의 회복양상을 고찰하고, 이를 토대로 교정치료를 위한 생물학적인 근간을 마련하기 위하여 본 연구를 시행하였으며, Hematoxylin & Eosin 및 Masson's Trichrome 염색법을 이용하여 치아와 주위조직의 반응을 치경부, 치근 중앙부, 치근단부로 나누어 광학현미경하에서 관찰하여 다음과 같은 결론을 얻었다. 1. 대조군의 HE 소견에서 치주인대는 치근단부에서 치근경부까지 비교적 균일한 두께를 나타냈고, 치주인대의 주행방향은 치근경부에 수평 또는 약간 경사져 있었으며, 치근 중앙부와 치근단부에서는 사선으로 주행하였다. 2. 대조군의 MT 소견에서 치경부에서는 조골세포 및 파골세포가 나타났으며 치경부, 치근 중앙부 그리고 치근단부에 약한 골흡수와 신생골 침착이 보였다. 3. 실험 1 군에서는 치근단부에서 뚜렷한 파골세포의 증가와 혈관 충혈이 보였으며, 신생골 형성과 불규칙한 반전선들이 나타나 골흡수하는 양상을 보였다. 치주인대는 치경부에서 치근단에 이르기까지 뚜렷한 증가를 보였으며 치근단부에서 더 심하였다. 4. 실험 2군에서는 대조군에 비해 조골세포가 치근단부에서 혈관 충혈과 함께 여전히 관찰되었다. 치주인대 폭경은 치근단부에서 대조군에 비해서는 증가되었고 1 군에 비해서는 감소된 양상을 보였다. 치주인대 주행방향은 1군과 같았고 단지 치근단부에서 혼합된 양상으로 관찰되었다. 이상과 같은 소견으로 보아 유성견 하악 소구치 압하시 초기 조직변화 에서 압박을 받는 치근단부에서 파골세포의 뚜렷한 증가, 출혈상 및 간격 확장, 그리고 골흡수와 백악질 흡수가 현저히 나타났으며, 치주인대 주행 방향도 다양하였다. 또한 압하력을 제거한 후에 변형되었던 치아와 치아 주위조직들이 완전한 회복 양상을 보이지는 않았다.

  • PDF

Porous Resorbable Calcium Carbonate와 Porous Replamireform Hydroxyapatite가 성견치주질환 이환 발치와내 이식된 치근과 발치와 치조골 재생에 미치는 영향 (The Effects of Porous Resorbable Calcium Carbonate and Porous Replamineform Hydroxyapatite on the regeneration of the alveolar bone in the Periodontally involved extraction sockets in dogs.)

  • 김종환;최성호
    • Journal of Periodontal and Implant Science
    • /
    • 제26권2호
    • /
    • pp.334-349
    • /
    • 1996
  • Regeneration of the periodontal tissue destroyed by periodontal disease is one of the final goals of periodontal therapy. In the past few years, periodontists have used various alloplastic grafting materials in an attempt to regenerate bone lost from periodontal disease. These materials have used widely because they have shown to be nontoxic, biologically compatible with surrounding host tissue and chemically similar to bone. The purpose of this study was to investigate the effect of Porous Resorbable Calcium Carbonate and Porous Replamineform Hydroxyapatite on the regeneration of the alveolar bone and the healing of roots transplanted into the periodontally diseased extraction sockets of dogs. The experimental chronic periodontitis was induced by elastic ligatures on the 2nd and 3rd mandibular premolars of 2 adult dogs for 8weeks after surgically creating periodontal defect. The extracted root were split in half along the long-axis, and the extend of plaque exposure was marked on the root surfaces with burs. The roots were inserted in extraction sockets with Porous Resorbable Calcium Carbonate(PRCC) in left side and with Porous Replaminefrom Hydroxyapatite(PRH) in right side. The flaps were sutured to cover the sockets completely. The animals were sacrificed after 12 weeks of healing, and the specimens were examined histologically. The results were as follows: 1. No inflammatory reactions were observed in either groups. 2. Hoot resorption was observed in both groups while the general outline of the roots were maintained. 3. PRCC was almost completely resorbed and replaced with new bone, while R.H.A. was not resorbed & remained encased in newly-formed C-T and alveolar bone. 4. PRH was encapsulated with alveolar bone which has been deposited from apical & lateral area of the sockets, while the coronal portion of the sockets were filled with C-T. 5. In both groups, the resorbed portions of the roots were replaced with new bone. These results suggest that either PRCC or PRH may not interfere with bone formation or healing in extraction sockets, and in some degree, retard the root resorption. Because the roots maintained in anatomy, we think that graft materials prevent the root resorption.

  • PDF