• Title/Summary/Keyword: Elastic Surrounding Tissue

Search Result 9, Processing Time 0.033 seconds

Histological observations of age-related changes in the epiglottis associated with decreased deglutition function in older adults

  • Masamitsu Serikawa;Kimiharu Ambe;Akinobu Usami
    • Anatomy and Cell Biology
    • /
    • v.56 no.3
    • /
    • pp.374-381
    • /
    • 2023
  • Although the epiglottis plays a vital role in deglutition, histological studies of the epiglottis and surrounding ligaments associated with swallowing dysfunction are limited. Therefore, we performed histological observations to clarify age-related changes in the morphological characteristics of the epiglottis and surrounding structures. Tissue samples comprising the epiglottis and surrounding structures were collected from corpses that were both orally fed and tubefed during their lifetimes. Following hematoxylin and eosin, Elastica Van Gieson, and immunohistochemical staining procedures, the chondrocytes, connective tissue, and glandular tissue were observed under the epiglottis epithelium, and intervening adipose tissue was observed in the surrounding area. Fatty degeneration of acinar cells was also observed in the glandular tissue, possibly because of aging. Bundles of elastic fibers were present around the vascular wall in the peri-epiglottic ligament, but some were reduced. Furthermore, large amounts of collagen fibers ran toward and through the cartilage, whereas the mesh-like elastic fibers stopped in front of the cartilage. Microfibrils considered to be oxytalan fibers, which are thinner and shorter than elastic fibers, were observed around the vascular wall and in the fiber bundles. Age-related changes included connective tissue fibrosis shown by the large amount of collagen fibers, atrophy of salivary glands, and an accompanying increase in adipose tissue. Regarding stretchability and elasticity, the elastic fibers may have an auxiliary function for laryngeal elevation during deglutition. This suggests that disuse atrophy of the laryngeal organs with or without oral intake might reduce the amount of elastic fiber in older adults.

Finite Element Analysis of End-to-End Anastomosis of Coronary Artery with Elastic Surrounding Tissue (탄성경계조직을 가진 관상동맥의 end-to-end 문합에 대한 유한요소해석)

  • Han, Geun-Jo;Kim, Tae-Hyung;Ahn, Sung-Chan;Shim, Jae-Joon
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.442-447
    • /
    • 2001
  • A finite element analysis of end-to-end artery/PTFE anastomosis has been presented in this study to evaluate the distribution of compliance in the vicinity of the anastomosis due to any mismatch in compliance characteristics. But, In these studies it was assumed that the artery and PTFE have the simple cylindrical shape representing the fatty tissue surrounding the coronary artery. And the fatty tissue was considered as the elastic surrounding materials in the finite element analysis. The simulation results were obtained as follows : 1. A fatty tissue was effect to reduce the compliance mismatch in the vicinity of a artery/PTFE anastomosis of different material because a hypercompliant zone become narrorw and a compliance discrepancy decrease between the artery and the PTFE about 70%. And radial direction displacement distribution with respect to distance in the vicinity of a artery/PTFE anastomosis was similiar. 2. The variation of PTFE thckness reduce the compliance mismatch in the vicinity of a artery/PTFE anastomosis about 25%.

  • PDF

The Study on the Mechanical Behavior of the Anastomosis with respect to the Thickness Variation of Elastic Foundation Using Simplified Suturing Model (단순봉합모델을 이용한 문합에서 탄성경계층의 두께 변화에 따른 기계역학적 거동에 관한 연구)

  • 이성욱;한근조;심재준;한동섭;김태형
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.8
    • /
    • pp.188-195
    • /
    • 2004
  • In this paper we analyzed the mechanical behavior with respect to the thickness variation of elastic foundation(fatty tissue) in end-to-end anastomosis. This study considered the preliminary deformed shape induced by suturing in the anastomosis of coronary artery and PTFE with different diameters using simplified suturing model and the fatty tissue surrounding heart and coronary artery for more accurate result using finite element method. Area compliance(CA) was used to analyze the final deformed shape of the anastomotic part with respect to the thickness variation of fatty tissue under mean blood pressure, 100mmHg(13.3㎪). And Equivalent and circumferential stresses in the anastomosis were also analyzed with respect to the change of initial diameter ratio( $R_1$) and fatty tissue thickness( $T_{F}$). The results obtained were as follows : 1 When the elastic foundation, assumed to be incompressive material, surrounded the grafts in anastomosis, the compliance mismatch of artery and PTFE was reduced by 47 -72%. 2. As the initial diameter ratio( $R_1$) became larger, the higher difference of compliance was induced in spite of elastic foundation surrounding grafts. 3. The maximum nondimensional circumferential stress is twice or three times as high as the maximum nondimensional equivalent stress in the anastomotic part.t.

The Study on Compliance Mismatch with respect to the Thickness Variation of Elastic Foundation in Anastomosis Using Simplified Suturing Model (단순봉합모델을 이용한 문합에서 탄성경계층의 두께 변화에 따른 컴플라이언스 부적합에 관한 연구)

  • 이성욱;심재준;한동섭;한근조;김태형
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1302-1305
    • /
    • 2003
  • In this paper we analyzed the effect of compliance mismatch with respect to the thickness variation of elastic foundation(fatty tissue) in end-to-end anastomosis. This study considered the preliminary deformed shape induced by suturing in the anastomosis of coronary artery and PTFE with different diameters using simplified suturing model and the fatty tissue surrounding heart and coronary artery for more accurate result using finite element method. Area compliance(C$\sub$A/) was used to analyze the final deformed shape of the anastomotic part with respect to the thickness variation of fatty tissue under mean blood pressure, 100 mmHg(13.3kPa). The results obtained were as follows : 1. When the elastic foundation, assumed to be incompressive material, surrounded the grafts in anastomosis, the compliance mismatch of artery and PTFE was improved by 47∼72%. 2. As the initial diameter ratio(R$\sub$I/) became larger, the higher difference of compliance was induced in spite of elastic foundation surrounding grafts.

  • PDF

Photoelastic Stress Analysis of the Abutment Surrounding Tissue According to Shape of the Proximal Plate of the RPI Clasp (압축하중시 RPI clasp의 3가지 다른 proximal plate 형태에 따른 지대치 주위조직의 광탄성 응력 분석)

  • Choi, Jung Soo;Kim, Busob
    • Journal of Technologic Dentistry
    • /
    • v.34 no.4
    • /
    • pp.473-482
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the stress distribution of the surrounding tissues according to 3 proximal plate types of the RPI clasp. Methods: The removeable partial denture which mandibular right and left second premolars and mandibular molars were lost was attached to a three dimensional photo elastic epoxy resin model. Then 120N of vertical load was applied. After 3-dimensional photoelastic stress analysis was used to record the isochromatic fringe patterns. Results: Kratochvil type guiding plane exhibited little uniform stress distribution on load center and alveolar ridge, but higher stress concentration on buccal surface of second premolar. Krol type guiding plane exhibited the stress concentration on the front of load center and relatively higher stress concentration on buccal surface of first premolar. However, this type had no effect on canine. Researcher type guiding plane showed the stress concentration on second premolar and molar, but the little stress distribution on first premolar. Conclusion: In all types, excessive stress concentration was appeared and three types were not significant different.

Ultrasonic Phantom Based on Plastic Material for Elastography (초음파 탄성 영상 평가를 위한 플라스틱 기반의 팬텀 개발)

  • Ahn, Dong-Ki;Joung, Mok-Keun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.4
    • /
    • pp.368-373
    • /
    • 2009
  • A human tissue mimicking phantom is constructed to assess the performance of a medical ultrasound elasticity imaging system. In a human body, the tumor or cancer is stiffer than its surrounding normal tissue. A technique fur imaging the elasticity of such a tissue is referred to as elastography. Homogeneous elasticity phantoms with differing Young's moduli are constructed using a plastic hardener and softener to simulate the mechanical characteristics of a diseased human tissue. The Young's modulus of the fabricated homogeneous phantom materials were measured from 11.1 to 79.6 kPa depending on the mixing ratio of the amount of the hardener to that of the softener. An ultrasound lesion mimicking phantom was made of these materials, and ultrasound elasticity imaging was performed on it. It is confirmed in this paper that the fabricated plastic-based elasticity phantom is useful in representing the elastic characteristics of a human tissue.

Analysis of the Mechanism of Thread-Embedding Acupuncture in Korean Medicine Beauty Treatment (한국의 한의 미용에서 매선요법 치료 기전에 대한 분석)

  • Eun-Young Park;Hyung-Sik Seo
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.36 no.4
    • /
    • pp.113-121
    • /
    • 2023
  • Objectives : The purpose of this study is to analyze the treatment mechanism of Thread-embedding acupuncture, which is used in Korean medicine beauty treatment. Methods : After searching papers published up to January 1, 2023 using the keyword "Thread-embedding" through the OASIS site, we selected beauty papers that mentioned the treatment mechanism of Thread-embedding acupuncture. Results : A total of 60 papers were retrieved: 19 papers on the topic of cosmetic diseases, 35 papers on the theme of other diseases, and 6 papers written unrelated to diseases. Among the 19 papers on the topic of cosmetic diseases, one unreadable paper was excluded. Among the 18 papers, we finally selected 6 papers that mentioned treatment mechanisms: 2 on facial wrinkles, 2 on obesity, 1 on breast enlargement, and 1 on transdermal hydration. The treatment mechanism of Thread-embedding acupuncture is that in the case of facial wrinkles, polydioxanone(PDO) is embedded to fill the volume, and as it decomposes, it causes a tissue reaction around the area. In obesity, it promotes fat decomposition by improving circulation, and promotes breast enlargement and elasticity through collagen formation. In transdermal hydration, it induces the production of surrounding fibers to increase skin elasticity and moisture. Conclusions : Thread-embedding acupuncture appears to have a cosmetic effect through a mechanism that promotes the production of collagen and elastic fibers in the subepidermal dermal layer and increases the activity of skin moisturizing factors during the absorption process after the PDO suture is embedded.

EARLY HISTO(PATHO)LOGIC CHANGES AND RECOVERY OF TOOTH AND PERIODONTAL TISSUE IN INTRUSION OF PREMOLAR ON YOUNG ADULT DOGS (유성견의 소구치 압하시 초기 치아 및 치주 조직의 조직학적 변화와 재생에 관한 연구)

  • Ahn, Byeong-Kyo;Cha, Kyung-Suk;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.28 no.2 s.67
    • /
    • pp.297-310
    • /
    • 1998
  • The purpose of this study was to investigate the initial tissue change, to repair on the teeth & surrounding tissue under the intrusive orthodontic forces by use of elastic chain, through the microscopic findings. For this study, three young adult mongrel dogs were used, and were divied into three group : the control group was deliveried only casting crown and the experimental group 1 was equipped with energy chain during 1 week and experimental 2 group was deliveried using energy chain during 1 week and 3 weeks observation. All experimental groups and control groups were sacrificed to make the samples for microscopic findings on premolar teeth. All samples were examed and compared the histologic changes through the microscopic with H-E stain. The obtained results were as follows. 1. In hematoxylin-eosin stain of the control group, the periodontal ligament was constant width from apical third to cervical third of the root, and the periodontal fiber arrangement was horizontal or oblique in cervical third, oblique in middle and apical third of the root. 2. In Masson Trichrome stain of the control group, osteoblast and osteoclast appeared in cervical third of root, and bone resorption and new bone formation was observed in middle and apical third of the root. 3. In experimental 1, osteoclasts were increased highly, and hyperemia of blood vessels and new bone formation and bone resorption by reversal line in apical third of the root were seen. PDL width was increased apprarently from crest to apex of the root and more in apical third. 4. In experimental 2, osteoclasts and hyperemia of blood vessels were more increased than control material in apical third of the root. PDL width was increased more than control group in root apex, and was seen less than experimental 1. PDL arrangement was similar to experimental 1 and was mixed only in root apex. Therefore, in premolar intrusion of the young adult dog, there were increased osteoclast, hyperemia and dilation of blood vessel, resorption of alveolar bone and cementum and different arrangement of PDL in initial tissue change. There was not observed complete repair after remove intrusive force.

  • PDF

The Effects of Porous Resorbable Calcium Carbonate and Porous Replamineform Hydroxyapatite on the regeneration of the alveolar bone in the Periodontally involved extraction sockets in dogs. (Porous Resorbable Calcium Carbonate와 Porous Replamireform Hydroxyapatite가 성견치주질환 이환 발치와내 이식된 치근과 발치와 치조골 재생에 미치는 영향)

  • Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.2
    • /
    • pp.334-349
    • /
    • 1996
  • Regeneration of the periodontal tissue destroyed by periodontal disease is one of the final goals of periodontal therapy. In the past few years, periodontists have used various alloplastic grafting materials in an attempt to regenerate bone lost from periodontal disease. These materials have used widely because they have shown to be nontoxic, biologically compatible with surrounding host tissue and chemically similar to bone. The purpose of this study was to investigate the effect of Porous Resorbable Calcium Carbonate and Porous Replamineform Hydroxyapatite on the regeneration of the alveolar bone and the healing of roots transplanted into the periodontally diseased extraction sockets of dogs. The experimental chronic periodontitis was induced by elastic ligatures on the 2nd and 3rd mandibular premolars of 2 adult dogs for 8weeks after surgically creating periodontal defect. The extracted root were split in half along the long-axis, and the extend of plaque exposure was marked on the root surfaces with burs. The roots were inserted in extraction sockets with Porous Resorbable Calcium Carbonate(PRCC) in left side and with Porous Replaminefrom Hydroxyapatite(PRH) in right side. The flaps were sutured to cover the sockets completely. The animals were sacrificed after 12 weeks of healing, and the specimens were examined histologically. The results were as follows: 1. No inflammatory reactions were observed in either groups. 2. Hoot resorption was observed in both groups while the general outline of the roots were maintained. 3. PRCC was almost completely resorbed and replaced with new bone, while R.H.A. was not resorbed & remained encased in newly-formed C-T and alveolar bone. 4. PRH was encapsulated with alveolar bone which has been deposited from apical & lateral area of the sockets, while the coronal portion of the sockets were filled with C-T. 5. In both groups, the resorbed portions of the roots were replaced with new bone. These results suggest that either PRCC or PRH may not interfere with bone formation or healing in extraction sockets, and in some degree, retard the root resorption. Because the roots maintained in anatomy, we think that graft materials prevent the root resorption.

  • PDF