• Title/Summary/Keyword: Effluent rate

Search Result 551, Processing Time 0.026 seconds

Effect of Pollutant Loading and Flow Distance to Wastewater Treatment Efficiency in the Constructed Wetland System (오염부하량 및 유하거리가 인공습지에 의한 폐수처리 효율에 미치는 영향)

  • 김형중;김선주;윤춘경
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.5
    • /
    • pp.97-108
    • /
    • 1997
  • Natural wastewater treatment systems using the constructed wetland system were evaluated for the wastewater from the industrial complex in rural areas. For the treatment of wastewater from the industrial complex in rural area, a pilot plant of the constructed wetland system was installed at Baeksuk agri-industrial complex in ChunahnCity, Chunchungnam-Do. The experiment with this pilot plants was performed for 1996 and 1997. Results of the study were summarized as follows. For the BOD and COD, when the pollutant loading of them was about 1 3.8g/$m^2$. day (the concentration was l24.0mg/${\ell}$) arid 24.4g/$m^2$.day(the concentration was 220.Omg/${\ell}$), the removal rate of them was high, 90.2% and 93.4%, respectively. For the SS, the effluent concentration was consistently lower than the water quality standard even though the influent concentration varied significantly, which showed that SS was removed by the system effectively which consist of soil and plants. For the T-N and T-P, when the influent pollutant loading of them were moderately high, 2.8g/$m^2$.day to 7.4g/$m^2$. day(concentration 25.0mg/${\ell}$ to 49.7mg/${\ell}$) for T-N and 1.0g/$m^2$.day to 2.6g /$m^2$.day(concentration 8.6mg/${\ell}$ to 14.7mg/${\ell}$) for T-P, the removal rate of them were 86.5% and 94.0%, respectively. The removal rate by the flow distance increased rapidly in the first 4m from the inlet zone, and gradually there after. The width of system was 2m. Overall, the result showed that constructed wetland system is a feasible alternative for the treatment of wastewater from industrial complex in rural areas. Compared to existing systems, this system is quite competitive because it requires low capital cost, almost no energy and maintenance, and therefore, very cost effective.

  • PDF

Quantification of Bacterial Attachment-related Parameters in Porous Media

  • Park, Seong-Jik;Lee, Chang-Gu;Kim, Song-Bae
    • Environmental Engineering Research
    • /
    • v.13 no.3
    • /
    • pp.141-146
    • /
    • 2008
  • Transport of Escherichia coli ATCC 11105 through porous media was investigated in this study using two sets of column experiments to quantify the attachment-related parameters (sticking efficiency, attachment rate coefficient and filter factor). The first set of experiments was performed in quartz sand under different ionic strength conditions (1, 20, 100, 200 mM) while the second experiments were carried out in quartz sand mixed with metal oxyhydroxide-coated sand (0, 5, 10, 25%). The breakthrough curves of bacteria were obtained by monitoring effluent, and then bacterial mass recovery and attachment-related parameters were quantified from these curves. The first experiments showed that the mass recoveries were in the range of 13.3 to 64.7%, decreasing with increasing ionic strength. In the second experiments, the mass recoveries were in the range of 15.0 to 43.4%, decreasing with increasing coated sand content. The analysis indicated that the sticking efficiency, attachment rate coefficient and filter factor increased with increasing ionic strength and coated sand content. The value of filter factor in the first experiments ranged from 1.45 e-2 to 6.72 e-2 1/cm while in the second experiments it ranged from 2.78 e-2 to 6.32 e-2 1/cm. Our filter factor values are one order of magnitude lower than those from other studies. This discrepancy can be attributed to the size of sand used in the experiment. The analysis demonstrated that the travel distance of bacteria estimated using the filter factor can be varied greatly depending on the solution chemistry and charge heterogeneity of porous media.

Effect of Hydrophilic- and Hydrophobic-Media on the Fermentative Hydrogen Production in Trickling Bed Biofilter (생물학적 수소생산을 위한 Trickling Bed Biofilter에서의 친수성과 소수성 담체의 영향)

  • Jeon, Byung-Seung;Lee, Sun-Mi;Kim, Yong-Hwan;Chae, Hee-Jeong;Sang, Byoung-In
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.465-469
    • /
    • 2006
  • Two mesophilic trickling bed bioreactors filled with two different types of media, hydrophilic- and hydrophobic-cubes, were designed and tested for hydrogen production via anaerobic fermentation of sucrose. Each reactor consisted of a column packed with polymeric cubes and inoculated with heat-treated sludge obtained from anaerobic digestion tank. A defined medium containing sucrose was fed with changing flow rate into the capped reactor, hydraulic retention time and recycle rate. Hydrogen concentrations in gas-phase were constant, averaging 40% for all conditions tested. Hydrogen production rates increased up to $10.5 L{\cdot};h^{-1}{\cdot}L^{-1}$ of reactor when influent sucrose concentrations and recycle rates were varied. Hydrophobic media provided higher value of hydrogen production rate than hydrophilic media at the same operation conditions. No methane was detected when the reactor was under a normal operation. The major fermentation by-products in the liquid effluent of the both trickling biofilters were acetate and butyrate. The reactor filled with hydrophilic media became clogged with biomass and bio gas, requiring manual cleaning of the system, while no clogging occurred in the reactor with hydrophobic media. In order to make long-term operation of the reactor filled with hydrophilic media feasible, biofilm accumulation inside the media in the reactor with hydrophilic media and biogas produced from the reactor will need to be controlled through some process such as periodical backwashing or gas-purging. These tests using trickling bed biofilter with hydrophobic media demonstrate the feasibility of the process to produce hydrogen gas in a trickle-bed type of reactor. A likely application of this reactor technology could be hydrogen gas recovery from pre-treatment of high carbohydrate-containing wastewaters.

  • PDF

Residue levels of phthalic acid esters (PAEs) and diethylhexyl adipate(DEHA) in various industrial wastewaters (업종별 산업폐수 중 프탈산에스테르와 디에틸헥실아디페이트의 잔류수준)

  • Kim, Hyesung;Park, Sangah;Lee, Hyeri;Lee, Jinseon;Lee, Suyeong;Kim, Jaehoon;Im, Jongkwon;Choi, Jongwoo;Lee, Wonseok
    • Analytical Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.57-64
    • /
    • 2016
  • Many phthalic acid esters (PAEs), including DMP, DEP, DBP, BBP, and DEHP, as well as DEHA are widely used as plasticizers in plastics. An analytical method was developed and used to analyze these compounds at 41 industrial facilities. The coefficient of determination (R2) for each constructed curve was higher than 0.98. The method detection limit (MDL) values were 0.4–0.7 μg/L for PAEs and 0.6 μg/L for DEHA. In addition, the recovery rate was shown to be 77.0–92.3%, while the relative standard deviation was shown to be in the range of 5.8-10.5%. DMP (n = 3), DEP (n = 2), DBP (n = 2), BBP (n = 2), and DEHA (n = 3) were detected in the range of 2.2-11.1% in the influent. DEHP was a predominant compound and was detected at > MDL in both the influent (n = 16, 35.6%) and the effluent (n = 4, 10.0%) at a high removal efficiency (92–100%). The highest levels of residue in industrial wastewater influent were 137.4 μg/L of DEHP at plastic products manufacturing facility, 12.5 μg/L of DEHA at a chemical manufacturing facility, and 14.0 μg/L of DEP at an electronics facility. The highest concentration of effluent was 12.5 μg/L of DEHP at a chemical manufacturing facility, which indicated that the effluent was below the allowable concentration (800 μg/L). Therefore, the levels of PAEs and DEHA that are discharged into nearby streams could not influence the health of the ecosystem.

Simultaneous Nitrification and Denitrification using Submerged MBR packed with Granular Sulfur and Non-woven Fabric (부직포 및 황 충진 MBR을 이용한 포기조내 동시 질산화/탈질에 관한 연구)

  • Moon, Jin-Young;Hwang, Yong-Woo;Park, Ji-Hyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.4
    • /
    • pp.439-446
    • /
    • 2009
  • This study was performed to evaluate SND(simultaneous nitrification and denitrification)efficiency, nitrogen removal efficiency and filtration function of non-woven fabric by using submerging MBR packed with granular sulfur covered with non-woven fabric filter. Synthetic wastewater was used as influent wastewater. Concentration of $NH_4{^+}-N$ in influent was maintained about 40 mg/L and the experiment was performed in four phases according to the flow rate. Nitrogen loading rate divided four phases ranging from $0.04 kg\;NH_4{^+}-N/m^3-day$ to $0.16 kg\;NH_4{^+}-N/m^3-day$. As a result, the maximum $NH_4{^+}-N$ removal rate was accomplished at $0.142 kg\;NH_4{^+}-N/m^3-day$ in nitrogen loading of $0.147 kg\;NH_4{^+}-N/m^3-day$. Nitrification efficiency was higher than 95% in all phases. $NO_3{^-}-N$ loading rate was adjusted ranging from $0.22 kg\;NO_3{^-}-N/m^3-day$ to $0.89 kg\;NO_3{^-}-N/m^3-day$. The maximum $NO_3{^-}-N$ removal rate was accomplished up to $0.71 kg\;NO_3{^-}-N/m^3-day$ in $NO_3{^-}-N$ loading of $0.89 kg\;NO_3{^-}-N/m^3-day$. The maximum $NO_3{^-}-N$ removal efficiency was 95% in $NO_3{^-}-N$ loading of $0.22 kg\;NO_3{^-}-N/m^3-day$. T-N removal rate was 90% and concentration of T-N in effluent was 3.7 mg/L in T-N loading rate of $0.039 kg\;NO_3{^-}-N/m^3-day$. In this study, TMP in reactor with and without non-woven fabric filter were observed to define fouling of hollow-fiber membrane module. Reaching time to standard washing pressure(22 cm Hg) of two reactors were 29 days with non-woven fabric But the reactor without non-woven fabric reached standard washing pressure only after 4 days. Accordingly, non-woven fabric was demonstrated the superiority as a filtration ability. With high nitrogen removal rate and decreasing of fouling of membrane, MBR packed with granular sulfur covered with non-woven fabric filter submerging in activated sludge aeration tank can be used as an advanced treatment process.

Effects of the Recirculation Port Location on Treatment Efficiency of an Anaerobic Hybrid Reactor Consisted of a Fluidized Bed and a Packed Bed (유동상과 충전상이 결합된 혐기성 혼성 반응조에서 순환수의 인출지점이 처리효율에 미치는 영향)

  • Kim, Seong-Yong;Park, Soo-Young;Cho, Kwang-Myeung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.11
    • /
    • pp.1935-1944
    • /
    • 2000
  • This research was performed to investigate the effects of the location of recirculation port on the wastewater treatment efficiency of an anaerobic hybrid reactor consisted of a fluidized bed and a packed bed. The recirculation port was located either at the top of the packed bed (Reactor 2) or above the fluidized bed (Reactor 1). Media for the fluidized bed and the packed bed were granular activated carbon and Pall ring-type plastic media. respectively. At organic loading rates(OLR) up to $6.2kg\;COD/m^3-day$. Reactor 2 showed somewhat better performance than Reactor 1 with COD removal efficiencies of 85.0-95.2%. The COD removal efficiencies of the reactors drastically deteriorated at OLRs above $6.2kg\;COD/m^3-day$, and the tendency was more severe for Reactor 1 than for Reactor 2. Eventhough the two reactors showed similar effluent SS concentrations at OLRs below $3.6kg\;COD/m^3-day$, Reactor 2 showed higher effluent SS concentrations than Reactor 1 at OLRs above $5.3kg\;COD/m^3-day$. Reactor 2 was stabler than Reactor 1 with a methane production rate of $5.5kg\;COD/m^3$-day at the OLR of $13.3kg\;COD/m^3-day$. An abrupt increase in effluent volatile acid concentration was observed at the OLR of $6.2kg\;COD/m^3-day$ for Reactor 1 and $7.1kg\;COD/m^3-day$ for Reactor 2. and the increase was greater in Reactor 1. In conclusion. the range of OLR for adequate treatment in the hybrid reactor was determined according to the location of the internal recirculation port. It is more desirable for higher OLRs to locate the recirculation port at the top of the packed bed in order to utilize the whole volume of the reactor.

  • PDF

Phosphorous Removal in a Free Water Surface Wetland Constructed on the Gwangju Stream Floodplain (광주천 고수부지에 조성한 자유수면인공습지의 인 제거)

  • Yang, Hong-Mo
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.1
    • /
    • pp.100-109
    • /
    • 2012
  • Removal rates of $PO_4-P$ and TP in a free water surface wetland system were investigated. The system was established in 2008 on a floodplain in the middle reach of the Gwangju Stream flowing through Gwangju City. Its dimensions were 46 meters in length and 5 meters in width. Two year old Typha angustifloria L. growing in pots were planted on half of the area and Zizania latifolia Turcz on the other half in 2008. Stream water was funneled into the wetlands by gravity flow, and its effluent was discharged back into the stream. The influent volume was controlled by valves and water depth was adjusted by wires. Volume and water quality of inflow and outflow were analyzed from January to December in 2010. Inflow into the system averaged approximately $710m^3/day$ and hydraulic residence time was about 1.5 hours. Average influent and effluent $PO_4-P$ concentration were 0.144 and 0.103mg/L, respectively, and $PO_4-P$ abatement amounted to 28.6%. Influent and effluent TP concentration averaged 0.333 and 0.262mg/L, respectively, and TP retention reached to 20.7%.$PO_4-P$ removal rate(%) during plant growing season(31.448) was significantly high(p<0.001) when compared with that during plant non-growing season(25.829). TP abatement rate(%) during plant growing season(27.230) was also significantly high(p<0.001) when compared with that of the non-growing season(14.856). Major phosphorous removals in the system resulted from adsorption of phosphorous in the litter-soil layers; sedimentation of particulate phosphorous and Ca, Al, Fe bounded phosphates; and absorption of phosphorous by emergent plants. The adsorption and sedimentation occurred throughout the year, however, the absorption took place during plant growing season. This resulted in higher removals of $PO_4-P$ and TP during plant growing season.

Change of Nutrients and Behaviour of Total Coliforms in the Natural Treatment of Wastewater by Subsurface Flow Wetland System (인공습지를 이용한 자연정화 오수처리시설에서 영양물질의 변화와 대장균군의 행동)

  • Yoon, Chun-Gyeong;Kwun, Soon-Kuk;Kim, Hyung-Joong
    • Korean Journal of Environmental Agriculture
    • /
    • v.16 no.3
    • /
    • pp.249-254
    • /
    • 1997
  • The constructed wetland system which is applicable to rural wastewater treatment was examined by pilot plant experiment. Removal rates of nutrients including nitrogen and phosphorus and total coliform were evaluated. The $NH_4\;^+$ concentration of the influent was in the range of 91.57 to 275.88mg/l and the effluent concentration was about 40% lower than the influent. The decreasing of the $NH_4\;^+$ concentration might be due to volatilization, plant uptake, adsorption onto soil particles, and mainly nitrification. However, generally concentrations of $NO_2\;^-$ and $NO_3\;^-$ were increased in the effluents compared to the influent concentrations, which implies that nitrogen components in the system were nitrified. Overall, the average removal rate of the nitrogen was about 5% which seems inadequate as a wastewater treatment system, and this system needs improvement on nitrogen removal mechamism. The removal rate of the phosphorus was quite high and effluent concentration was very low. Reason for high removal rate of the phosphorus might be mainly strong adsorption characteristic onto soil particles. The average removal rate of the total coliforms was about 83%, and main removal mechanisms are thought to be adsorption onto soil and inability to compete against the established soil microflora. From the results of the study, the constructed wetland system needs to be improved in nitrogen removal mechanism for field application.

  • PDF

Chemical Analysis of Transplanted Aquatic Mosses and Aquatic Environment during a Fish Kill on the Chungnang River, Seoul, Korea

  • Lee, Joohyoung;Green, Perry-Johnson;Lee, Eun-Ju
    • Animal cells and systems
    • /
    • v.6 no.3
    • /
    • pp.215-219
    • /
    • 2002
  • In mid-April, 2000, hundreds of thousands of fish floated dead on the Chungnang River, one of the small branches of the Han River in Seoul. We examined the causes of the accident in detail, through analysis of monitorinq data from the Han River Monitoring Project, which employed the transplanted aquatic moss, Fontinalis antipyretica. This allowed investigation of another possible cause of the fish kill: release of trace metals into the river from industrial sources during the rainfall event. In addition, we aimed to verify the usefulness of aquatic mosses as bioindicators of the event. Water samples collected 48 h after the fish kill exhibited low pH and high Total-N and Total-p, indicating that acidic compounds rich in nitrogen and phosphorus might be a major contaminant. BOD and COD were also very high. On the whole, the conditions of the river water were degraded at that time. Distinct trends were not observed in the chlorophyll phaeophy-tinization quotient and photosynthesis rate of transplanted mosses. How-ever mosses sampled soon after the accident exhibited the lowest values for those variables (P < 0.01), suggesting that stress factors in the river were diluted out over time. Heavy metals with characteristics of industrial effluents (Cr, Pb, Zn, Fe, Cu, and Cd) increased (p < 0.01), indicating that they were unlikely to be major causes of the accident.

Novel Bi2S3/TiO2 Heterogeneous Catalyst: Photocatalytic Mechanism for Decolorization of Texbrite Dye and Evaluation of Oxygen Species

  • Zhu, Lei;Oh, Won-Chun
    • Journal of the Korean Ceramic Society
    • /
    • v.53 no.1
    • /
    • pp.56-62
    • /
    • 2016
  • A heterogeneous $Bi_2S_3/TiO_2$ composite catalyst was synthesized via a green ultrasonic-assisted method and characterized by XRD, SEM, EDX, TEM analysis. The results clearly show that the $TiO_2$ particles were homogenously coated with $Bi_2S_3$ particles, indicating that $Bi_2S_3$ particle agglomeration was effectively inhibited after the introduction of anatase $TiO_2$. The Texbrite BA-L (TBA) degradation rate constant for $Bi_2S_3/TiO_2$ composites reached $8.27{\times}10^{-3}min^{-1}$ under visible light, much higher than the corresponding value of $1.04{\times}10^{-3}min^{-1}$ for $TiO_2$. The quantities of generated hydroxyl radicals can be analyzed by DPCI degradation, which shows that under visible light irradiation, more electron-hole pairs can be generated. Finally, the possible mechanism for the generation of reactive oxygen species under visible-light irradiation was proposed as well. Our result shows the significant potential of $Bi_2S_3$-semiconductor-based $TiO_2$ hybrid materials as catalysts under visible light for the degradation of industry dye effluent substances.