• Title/Summary/Keyword: Effluent rate

Search Result 551, Processing Time 0.023 seconds

Theoretical Approach to Calculating rms-Velocity Gradient in Flocculators (응집지 속도경사(G) 계산에 대한 이론적인 고찰)

  • Kim, Ja-Kyum
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.3
    • /
    • pp.351-356
    • /
    • 2004
  • Selecting appropriate G values in flocculator operation is important to produce high quality filter effluent in water treatment plants. However, misunderstanding and misleading of G calculation for the case of having power sources more than one or many paddles with one power source in a flocculation basin sometimes have led to low performance in flocculation. Theoretical analysis confirmed that the total G value in one flocculation unit having power sources more than one or with many paddles is the root-square of the sum of square of individual G value. This analysis also can give a simple calculation method of G value for designers and operators in fields.

Electrokinetic Remediation of Cobalt Contaminated Soil (코발트 오염토양 동전기적 제염)

  • 김계남;오원진
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.290-293
    • /
    • 2000
  • After kaolin clay was compulsorily contaminated with Co$^{2+}$ion, the remediation characteristics by electrokinetic method were analyzed. Ethanoic buffer was injected in the soil column and $CH_3$COOH was continuously inputted in cathode reservoir to restrain the pH elevation. Since pH of the cathode side of the soil column was 4.0 at initial and was restrained by 6.5 at 43.6 hours, Precipitation, Co(OH)$_2$, was not formed in the column. Effluent rate increased with time passage and remediation in the column in initial time was mainly controlled by ion migration. 13.1% of total in the soil column was remediated in 10 hours, and the 6.8% of total in 20.8 hours, and the 71.7% of total in 43.6 hours, and the 94.6% of total in 43.6 hours. Meanwhile, the residual concentrations in the column calculated by the developed model were similar to those by experiment.t.

  • PDF

Determination of Letrozole in formulation by a Validated RP-HPLC method

  • Ganesh, Mani;Bhagiyalakshm, Margandan;Vinoba, Mari;Jang, Hyun-Tae
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05b
    • /
    • pp.1230-1232
    • /
    • 2010
  • A simple, rapid and validated reverse d phase liquid chromatographic method has been developed for the determination of Letrozole (LZ) in pharmaceutical dosage. LZ was separated on ODS analytical column with a mixture of acetonitrile, water in the ratio 50:50 (v/v) as mobile phase at a flow rate of 1.0 mL /min. The effluent was monitored by UV detection at 265nm. Calibration plot was linear in the range of 160 to $240{\mu}g$/mL with the linear regression (r) = 0.999. The method was validated for recovery, precision, specificity.

  • PDF

Low Temperature Dyeing Process by Intercellular diffusion through Cell Membrane Complex Modification of Wool. - Technology based on CSIRO and ICI (양모의 저온 염색 소개 - Sirolan LTD Process from ICI)

  • 윤일남
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2001.11a
    • /
    • pp.3-11
    • /
    • 2001
  • Fundamental studies at the CSIRO division of Wool technology and ICI on the diffusion of dyes into wool〔1,2〕have let to development of a new approach to wool dyeing. In this method, the cell membrane complex of wool is modified before dyeing by treatment under mildly alkaline conditions with a special chemicals. Wool pretreated with ethoxylated quaternary ammonium salt has an increased rate of dyebath exhaustion and dye penetration early in the dyeing cycle. This enables the treated material to be dyed below the boil for a similar time to the conventional cycle. This technique can be used on untreated and shrinkresist-treated wool and wool/nylon blends. In addition to good macro-levelness and excellent coverage of tippiness, the low temperature dyeing process give higher exhaustion levels of dyestuffs and insect-resist agent and hence cleaner effluent liquors, compared with conventional dyeing process. Low Temperature Dyeing process cause significantly less fiber damage than conventional way. The reduction in damage is reflected in improved processing performance of the dyed wool.

  • PDF

Degradation of MS(Linear Alkylbenzene Sulfonate) by Plasmid (LAS(Linear Alkybenzene Sulfonate)의 Plasmid에 의한 분해)

  • 차전옥;유진삼;백형석
    • Microbiology and Biotechnology Letters
    • /
    • v.22 no.2
    • /
    • pp.158-163
    • /
    • 1994
  • Microorganisms capale of utilizing linear alkylbenzene sulfonates(LAS) as sole carbon source were isolated from industrial effluent by using LAS agar plates. The isolated strains were identified as Salmonella sp(BC-2) and Escherichia sp.(BC-3) from the results of morphological, cultural and biochemical tests. The optimal condition for the growth and biodegradation of LAS was the initial pH 7.0 and LAS concentration 0.1%. The isolated BC-2 and BC-3 strains harbored plasmid and LAS-degrading activity was lost when the plasmids were cured by mitomycin C. The plasmids were transformed into E. coli and transformants have the LAS-degrading activity. Isolated strains were examined for primary biodegradation rate of LAS in the medium by methylene blueactive substance(MBAS) method. Of these isolates, BC-2 and BC-3 strains degradated LAS upto 60% and high resistant to CdCl$_{2}$ and HgCl$_{2}$. Isolated strains were sensitive to chloramphenicol, kanamycin, rifampicin, streptomycin and tetracycline but resistant to ampicillin and lincomycin.] Its minimal inhibitory concentration(MIC) for ampicillin was more than 1500 $\mu $g/ml.

  • PDF

Estimation of Transport and the Mass Balance of a Molecular Marker (DSBP) in Tokyo Bay Using an Ecological Model (생태계 모델을 이용한 동경만 Molecular Marker(DSBP)의 거동 에측 및 물질수지 선정)

  • Kim, Dong-Myung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.44 no.2
    • /
    • pp.167-172
    • /
    • 2011
  • A three-dimensional ecological model (EMT-3D) was applied to Tokyo Bay to simulate 4,4'-bis (2-sulfostyryl)biphenyl (DSBP). The simulated results were in good agreement with the observed values, with a correlation coefficient of R=0.8431 and a coefficient of determination of $R^2$=0.7108. The sensitivity analysis indicated that the photolysis rate is the most important factor. Therefore, the parameters must be considered carefully in modeling. The mass balance results showed that the standing stock of DSBP in water and in particulate organic carbon was 621.2 and 19.5 kg, respectively, and the effluent flux to the open sea was 2.63 and 0.055 kg/day, respectively.

Inactivation of Microorganisms in Sewage Using a Pilot Plasma Reactor (Pilot 플라즈마 반응기를 이용한 하수 중 미생물의 불활성화)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.3
    • /
    • pp.289-299
    • /
    • 2013
  • Objectives: For the field application of the dielectric barrier discharge plasma reactor, scale-up of the plasma reactor is needed. This study investigated the possibility of inactivation of microorganisms in sewage using pilot multi-plasma reactor. We also considered the possibility of degradation of total organic carbon (TOC) and nonbiodegradable matter ($UV_{254}$) in sewage. Methods: The pilot plasma reactor consists of plasma reactor with three plasma modules (discharge electrode and quartz dielectric tube), liquid-gas mixer, high voltage transformers, gas supply equipment and a liquid circulation system. In order to determine the operating conditions of the pilot plasma reactor, we performed experiments on the operation parameters such as gas and liquid flow rate and electric discharge voltage. Results: The experimental results showed that optimum operation conditions for the pilot plasma reactor in batch experiments were 1 L/min air flow rate), 4 L/min liquid circulation rate, and 13 kV electric discharge voltage, respectively. The main operation factor of the pilot plasma process was the high voltage. In continuous operation of the air plasma process, residual microorganisms, $UV_{254}$ absorbance and TOC removal rate at optimal condition of 13 kV were $10^{2.24}$ CFU/mL, 56.5% and 8.6%, respectively, while in oxygen plasma process at 10 kV, residual microorganisms, $UV_{254}$ absorbance and TOC removal rate at optimal conditions were $10^{1.0}$ CFU/mL, 73.3% and 24.4%, respectively. Electric power was increased exponentially with the increase in high voltage ($R^2$ = 0.9964). Electric power = $0.0492{\times}\exp^{(0.6027{\times}lectric\;discharge\;voltage)}$ Conclusions: Inactivation of microorganisms in sewage effluent using the pilot plasma process was done. The performance of oxygen plasma process was superior to air plasma process. The power consumption of oxygen plasma process was less than that of air plasma process. However, it was considered that the final evaluation of air and oxygen plasma must be evaluated by considering low power consumption, high process performance, operating costs and facility expenses of an oxygen generator.

Assessment of Degradation Rate Coefficient and Temperature Correction Factor by Seasonal Variation of Concentration and Temperature in Livestock Wastewater Treatment in Field Scale (현장수준의 축산폐수처리에 있어서 계절별 농도 및 온도변화에 따른 분해반응계수 및 온도보정계수의 산정)

  • 박석환
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.2
    • /
    • pp.90-95
    • /
    • 1996
  • This study was performed to calculate the degration rate coefficient, operating parameters to meet the effluent standards, and the temperature adjustment coefficients to each parameter of pollution by seasonal variation of concentration and temperature of influent in livestock wastewater treatment by sequencing batch reactor process in field scale. The followings are the conclusions that were derived from this study. 1. In the field, temperature of livestock wastewater in reactor was 20.3$\circ$C in summer and 6.0$\circ$C in winter. The ratio of BOD:TKN: T-P in influent was 100:80:7. BOD loadings in winter and spring were 0.26 and 0.43 kg $BOD/m^3$ day, respectively. Those in summer and fall were 0.25 and 0.13 kg $BOD/m^3$ day, respectively. 2. The degradation rate coefficient for TKN was larger in summer and fall in which temperature was high than that in which temperature was high than that in winter and spring in which concentration was high. On the contrary, the phosphorus uptake rate was larger in winter and spring than that in summer and fall. 3. The hydraulic retention time in winter and spring was longer than that in summer and fall. Especially, in order to meet the standard for TKN of 120 mg/l in winter in which temperature of wastewater was 6.0$\circ$C, as the MLSS concentration was increased from 4, 000 to 7, 000 mg/l, the hydraulic retention time was increased from 212 to 121 hours. But, in order to shorten that less than 121 hours for the economical wastewater treatment, countermeasure to increase temperature of wastewater in the reactor should be considered. 4. the temperature adjustment coefficients for BOD, $COD_{Mn}$, TKN and T-P were 1.0241, 1.0225, 1.0541 and 1.0495, respectively. Namely, the treatment of TKN was most sensitively affected by temperature. For the purpose of the effective removal of nitrogen and phosphorus which are sensitive to temperature, it is necessary to keep the temperature of livestock wastewater more than 20$\circ$C which is the temperature of it in summer.

  • PDF

Separation Performance of a Low-pressure Hydrocyclone for Suspended Solids in a Recirculating Aquaculture System

  • Lee, Jin-Hwan
    • Fisheries and Aquatic Sciences
    • /
    • v.13 no.2
    • /
    • pp.150-156
    • /
    • 2010
  • The separation performance of a low-pressure hydrocyclone (LPH) was evaluated for suspended-solids removal in a recirculating aquaculture system (RAS). The dimensions of the LPH were 335 mm cylinder diameter, 575 mm cylinder height, 60 mm overflow diameter, 50 mm underflow diameter, and $68^{\circ}$ cone angle. The inflow rate varied (400, 600, 800, and 1,000 mL $s^{-1}$) with 25%, 25%, 20%, and 10% of bypass ($R_f$), respectively. The maximum total separation efficiency (Et) and reduced separation efficiency (E't) for suspended solids from the effluent of the second settlement tank (before biofiltration) were 58.9% and 45.2%, respectively, at an inflow rate of 600 mL $s^{-1}$ and 25% of $R_f$. The maximum Et and E't for suspended solids from the water supply channel (after biofiltration) were 24.4% and 16%, respectively, at an inflow rate of 1,000 mL $s^{-1}$ and 10% of $R_f$. The maximum grade efficiency (Ei) was 51.6% for a 300 ${\mu}m$ particle size at an inflow rate of 600 mL $s^{-1}$ with 23% of $R_f$. The maximum reduced grade efficiency (E'i) was 37.6% for a 300 ${\mu}m$ particle size at an inflow rate of 1,000 mL $s^{-1}$ with 11% of $R_f$. The results indicate that the separation performance of the LPH for suspended solids removal was size selective and that maximum removal occurred at particle sizes ranging from 300 to 500 ${\mu}m$.

Comparison of Overall Oxygen Transfer Coefficient in the Membrane Coupled High Performance Reactor for a High Organic Loading Wastewater Treatment (고부하 유기성 폐수처리를 위한 분리막 결합형 순산소 고효율 포기장치의 총괄 산소전달효율 평가)

  • Kang, Bum-Hee;Lim, Kyeong-Ho;Lee, Sang-Min
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.1
    • /
    • pp.81-88
    • /
    • 2010
  • This study was conducted to find the capability of comparison of overall oxygen transfer coefficient in the membrane coupled high performance reactor (MPHCR) in treating high organic loading wastewater. Effluent quality had been analyzed while the influent organic loading rate was changed from 2 to $7kg\;COD/m^3{\cdot}day$. The oxygen transfer coefficients had been investigated using two-phase nozzle for operating variables which were internal circulation flowrate (5~8 L/min), air flow rate (0.0125~0.2 L/min), liquid temperature ($10{\sim}20^{\circ}C$), and pure-oxygen flow rate (0.0125~0.2 L/min). The overall oxygen transfer coefficient was increased with flowrate of internal circulation and air and high temperature. Especially, internal circulation flow rate showed distinct effect on overall oxygen transfer coefficient due to an increase of gas holdup and air-liquid contract area by two-phase nozzle. In the high range of organic loading rate from 4 to $7kg\;COD/m^3{\cdot}day$, the removable efficiency of COD was 91%. Conventional activated sludge process usually treat organic loading from 0.32 to $0.64kg\;COD/m^3{\cdot}day$ however, the MPHCR can treat 10 to 20 times higher if it would be compared to the conventional activated sludge process. Foaming problem often happened and caused biomass wash out of the reactor, therefore, the foaming should be controlled for the enhanced operation.