• 제목/요약/키워드: Effluent rate

검색결과 551건 처리시간 0.029초

효율적 질소제거를 위한 단일 혐기성반응조의 개선 (Improvement of Single Anaerobic Reactor for Effective Nitrogen Removal)

  • 한동준;류재근;임연택;임재명
    • 환경위생공학
    • /
    • 제12권3호
    • /
    • pp.9-17
    • /
    • 1997
  • This research aims to remove nitrogen in the piggery wastewater by combined process with upflow anaerobic sludge blanket (UASB) and biofilm process. For the effective denitrification. anaerobic and anoxic reactors were connected to a reactor. The effluent of aerobix reactor was recycled equally with influent in the upper filter of anaerobic reactor for denitrification and outlet of UBF reactor was connected to the settling tank with $1.5{\;}{\ell}$ capacity and the settling sludge was repeatedly recycled to UASB zone. The organic loading rate of total reactor was operated from 0.4 to $3.1kgCOD/m^{3}/d$ and it was observed that the removal rate of TCOD was 80 to 95 percentage. Ammonia nitrogen was removed over 90 percentage in the less volumetric loading rate than $0.1{\;}kgN/m^{3}/d$. But because of non-limitation of organic materials, it was reduced to 70 percentage in the more volumetric loading rate than $0.6{\;}kgN/m^{3}/d$. But denitrification rate was observed 100 percentage in the all of loading rate. This is caused by the maintenance of optimum temperature, sufficient carbon source, and competition of electron acceptors. The results of COD mass balance at the $1.21{\;}kgCOD/m^{3}/d$ was observed with the 71.7% percentage of influent COD. It was revealed that the most part of organic materials was removed in the aerobic and the anaerobic reactor because 38.4 percentage was conversed into $CH_{4}$ gas and 11 percentage was removed in the aerobic reactor with cell synthesis and metabolism. Besides, 5.7% organics was used to denitrification reaction and 3.7% organics related to sulfate reduction.

  • PDF

황 충진 MBR을 이용한 도금폐수의 고효율 생물학적 질소 제거 (High-Rate Biological Nitrogen Removal from Plating Wastewater using Submerged MBR Packed with Granular Sulfur)

  • 김대영;문진영;백진욱;황용우
    • 상하수도학회지
    • /
    • 제19권2호
    • /
    • pp.200-208
    • /
    • 2005
  • In this study, a new submerged membrane bioreactor process packed with granular sulfur (MBR-GS) was operated to identify the biological nitrogen removal behaviors with plating wastewater containing high-strength $NO_3{^-}$ concentration. The continuous denitrification was carried out at $20^{\circ}C$ with various nitrogen loading rates using synthetic wastewater, which composed of $NO_3{^-}$ and $HCO_3{^-}$, but also actual plating wastewater, which was collected from the effluent of the H metal plating company. As a result, high-rate denitrification in the range of $0.8kg\;NO_3{^-}-N/m^3\;day$ was accomplished at nitrogen loading rate of $0.9kg\;NO_3{^-}-N/m^3\;day$ using synthetic wastewater. Also, higher-rate denitrification with actual plating wastewater was achieved up to $0.91kg\;NO_3{^-}-N/m^3\;day$ at the loading rate of $1.11kg\;NO_3{^-}-N/m^3\;day$. Additionally, continuous filtration was possible during up to 30 days without chemical cleaning in the range of 20 cmHg of transmembrane pressure. On the basis of the proposed stoichiometry, ${SO_4}^{2-}$ production could be estimated efficiently, while observed alkalinity consumption was somewhat lower than theoretical value. Consequently, a new process, MBR-GS is capable of high-rate autotrophic denitrification by compulsive flux and expected to be utilized as an alternative of renovation techniques for nitrogen removal from not only plating wastewater but also municipal wastewater with low C/N ratio.

방사선안전관리 실무: (II) 배기중 및 배수중 배출관리기준의 적용 (Practical Radiation Safety Control: (II) Application of Numerical Guidance for the Discharges of Radioactive Gaseous and Liquid Effluents)

  • 김현기
    • Journal of Radiation Protection and Research
    • /
    • 제39권1호
    • /
    • pp.61-64
    • /
    • 2014
  • 방사성동위원소를 포함하는 방사성물질은 전력생산에서부터 연구, 산업, 진단 및 치료 등의 목적으로 다양하게 활용되고 있다. 비밀봉 방사성물질을 이용하는 시설에서 이들 시설로부터 기체, 입자 또는 액체 형태의 방사성물질이 다소간 환경으로 배출되는 것은 피할 수 없으며, 이는 일반인의 방사선피폭을 야기하는 주요한 인공 방사선원이다. 본 논문은 보수적 가정과 간단한 계산에 의거하여 액상의 비밀봉선원을 사용하는 시설에서 배기설비를 통해 배출되는 공기중 방사성물질의 최대농도와 방사성폐액을 저장하는 저류조 배수구에서 배출되는 폐액중 방사성물질의 평균농도를 산출한 후, 관련 고시에서 정하는 각각의 배출관리기준값과 비교함으로써 일반인의 피폭 정도를 평가하는 절차를 제공한다. 이를 위해 방사성핵종의 1일 사용량, 취급형태, 비산율, 방사성폐액 발생량, 배기설비, 배수설비 등을 적절히 가정하였다. 제시된 절차는 비밀봉 방사성물질을 취급하는 시설에서 환경으로의 방사성물질의 계획적 배출에 따른 주변환경 영향평가에 손쉽게 적용할 수 있으므로 일반인의 피폭량 감축에 필요한 시설에서의 방사선안전관리 실무요건 도출에 활용할 수 있다.

pH와 첨가제에 의한 이산화염소의 분해율 및 펄프 표백효과(2)-첨가제가 chlorate 생성량의 감소와 펄프 표백 효과에 미치는 영향 (Pulp Bleaching Effect and Ionization Rate of Chlorine Dioxide by Additive and Various pH Conditions (II))

  • 윤병호;왕립군
    • 펄프종이기술
    • /
    • 제31권4호
    • /
    • pp.49-57
    • /
    • 1999
  • In CLO2 delignification and bleaching process, formation of chlorate corresponds to a loss of 20-36% of the original CKO2 charge. Because chlorate is inactive and harmful to environmental, it will be of benefit to find methods that can reduce the formation of chlorate during chlorine dioxide bleaching. Chlorate is mainly formed by the reaction HCIO +ClO2 $\longrightarrow$H+ + Cl_ +ClO3-2 On the other hand, AOX in chlorine dioxide bleacing is formed also due to the in-situ produced hypochlorous acid. THus both AOX and chlorate could be reduced by addition of hypochlorous acid. Some paper son the reduction of AOX by additives appeared , but systematic data on chlorate reduction as well as pulp and effluent properties are not available. THus this paper of focused on the effects on the reduction of chlorate and chlorine dioxide bleachability. The additives, fulfamic a챵, AMSO, hydrogen peroxide, oxalic acid were found to eliminate chlorine selectively in chlorine and chlorine dioxide mixture.However, when they were added to bleaching process, sulfamic acid and DMSO showed significant reduction of chlorate formation but hydrogen peroxide and oxalic aicd did not, and significant amount ofhydrogen peroxide was found resided in the bleaching effluent , In addition, sulfamic acid and DMSO decreased the bleaching end ph values while hydrogen peroxide and oxalic acid did not, which also indicated that hydrogen peroxide and oxalic acid were ineffective. The difference might be ascribed to the competitives of hypochlorous acid with lignin, chlorite (CKO2) and additives. Sulfamic acid and DMSO showed better pulpbrightness development but less alkaline extraction efficiency than hydrogen peroxide , oxalic acid and control, which means that insitu hypochlorous acid contributes to the formation of new chromophore structures that can be easily eliminated by alkaline extraction. DMSO decreased the delignification ability of chlorine dioxide due to the elimination of hypochlorous acid, but sfulfamic acid did to because the chlroinated sulfamic acid had stable bleachability. In addition, sulfamic acid, and SMSO shwed decreased color and COD of bleaching effluents, hydrogen peroxide decreased effluent color but not COD content, and oxalic acid had no statistically significant effects. No significant decreases of pulp viocosity were found except for hydrogen peroxide. Based on our results , we suggest that the effectiveness of hydrogen peroxide on the reduction of AOX in literature might be explained by other mechanisms not due to the elimination of hypochlorous acid , but to the direct decomposition of AOX by hydrogen peroxide.

  • PDF

양돈분뇨 퇴비화공정에서 발생하는 침출액의 화학적처리 (Chemical Treatment of Leachate from Swine Manure Composting System)

  • 정태영;오인환;김동수
    • 한국축산시설환경학회지
    • /
    • 제8권3호
    • /
    • pp.145-152
    • /
    • 2002
  • Slurry type 고농도 양돈분뇨의 퇴비화과정에서 발생하는 침출수를 응집침전 방법으로 처리시 그 효과를 검증하기 위하여 본 실험을 실시하였다. 이를 위해 퇴비화가 주목적인 완전혼합식 진천시 소재 A양돈장 퇴비단침출수와 정화처리를 위해 침출수 배출이 주목적인 이천시 소재 B양돈장 퇴비단 침출수의 응집침전 실험을 수행하였으며, 그 결과는 다음과 같다. 1. A양돈장 퇴비단 침출수의 응집실험 결과, 적정 농도는 Alum 750mg/l, 양이온 폴리머는 62.5mg/l이었으며 $BOD_5$, T-N, T-P의 농도는 각각 19, 257.5, 0.4mg/l로 축산 폐수처리시설의 방류수 수질기준에 적합한 처리 효율을 보였다. 2. B양돈장 퇴비단 침출수의 응집실험 결과, 적정 농도는 $FeCl_3$, 1,500mg/l와 FO4240 l0mg/l이었으며 $BOD_5$, T-N, T-P의 농도는 각각 15.3, 829.4, 2.8mg/l로 축산폐수처리 시설의 방류수 수질기준에는 T-N 농도가 높아 부적합하였다. 이는 침출수내 암모니아성 질소의 농도가 높았기 때문으로 사료된다. 3. 개별 축산농가의 퇴비단 침출수 처리를 위해서는 침출수 내 암모니아성 질소의 농도가 낮을 경우 응집 침전에 의한 처리만으로도 방류수 수질기준에 도달할 수 있으나, 암모니아성 질소의 농도가 높을 경우에는 후단에 생물학적 처리 시설이 필요할 것으로 판단된다.

  • PDF

실험실 규모 2상 혐기성 소화를 이용한 음식물 쓰레기 탈리액의 처리 (Treatment of Food Waste Leachate using Lab-scale Two-phase Anaerobic Digestion Systems)

  • 허안희;이은영;김희준;배재호
    • 대한환경공학회지
    • /
    • 제30권12호
    • /
    • pp.1231-1238
    • /
    • 2008
  • 본 연구에서는 실험실 규모 2상 혐기성 소화를 이용하여 음식물 쓰레기 탈리액의 처리성을 평가하였다. 이를 위해 산발효조의 적정 유입 pH 및 HRT를 도출하고, 산발효조로의 메탄조 유출수 반송 효과, 메탄발효조에서 고형물 내부반송 및 온도의 영향을 파악하였다. 산발효조에서는 유입 pH 6.0, HRT 2일인 조건에서 메탄조 유출수 반송 후 산생성 및 VS 제거효율은 30% 및 40%에서 안정적으로 유지되었다. 유기물 부하 7 g COD/L/d 이하의 조건에서 고형물 내부반송에 의해 중온 및 고온메탄발효조의 유출수 SCOD는 반송 이전보다 낮거나 같은 수준으로 유지되었고 유기물 부하 증가에 따른 비메탄생성량(specific methane production, SMP)의 감소폭이 줄어들었다. 고형물 내부반송 이후 동일한 유기물 부하에서 COD 제거효율과 SMP는 중온메탄발효조가 고온보다 우수하였으며 이는 중온메탄발효조의 MLVSS 농도가 고온보다 높기 때문인 것으로 판단되었다. 따라서 고온산발효-중온메탄발효로 구성된 시스템이 고온산발효-고온메탄발효보다 COD 제거와 메탄발생면에서 우수한 것으로 나타났다.

분리막이 결합된 무산소·호기 공정을 이용한 축산폐수처리에서 수리학적체류시간 및 내부반송율이 유기물 및 질소제거에 미치는 영향 (Effect of HRT and Internal Recycle Ratio on Removal of Organic and Nitrogen in Swine Wastewater by Anoxic-Oxic Process Combined with Membrane)

  • 황규대;이봉희;이현덕
    • 한국물환경학회지
    • /
    • 제20권6호
    • /
    • pp.603-609
    • /
    • 2004
  • The objective of this study was to determine the optimal operation conditions in an anoxic oxic process to eliminate both organic and nitrogen matters in swine wastewater. For the purpose of this, the removal efficiency was evaluated with various HRTs and internal recycling ratio. During the whole 580 days of experiment, HRTs had been gradually decreased in an order of 20, 14, 12 and l0days, and the internal recycle ratio was kept at 20Q. So as to determine the effect of the internal recycle ratio on the nitrogen removal, the internal recycle ratio had been gradually increased from 20Q to 50Q while HRT was maintained at 12days. As a result, it was shown that the removal efficiency of organic matter was above 95% regardless of changing of HRTs. The average influent concentration of TCODcr and SCODcr were 24,854 mg/L and 18,920 mg/L, respectively. Average removal efficiency of TKN was shown to be nearly 98% when HRT was kept at 12days; however, the $NH_4{^+}-N$ concentration of effluent was shown to be increased when the loading rate of $NH_4{^+}-N$ was increased to $0.602 kgNH_4{^+}-N/m^3$-day by means of decreasing HRT to 10days. It was concluded that nitrogen loading rates should be more considered rather than organic loading rates in case of determining an optimal HRT. When gradually increasing the internal recycle ratio from 20Q to 50Q, the removal efficiency of organic matters and TKN were 96% and 98%, respectively so that no significant changes in removal efficiency was detected. However, when the internal recycle ratio was kept at 50Q, it was revealed that the $NO_3-N$ concentration of effluent seemed to drop and the average $NO_3-N$ concentration of effluent was around 52 mg/L.

경안천과 팔당호에서 총세균수의 분포 및 동태 (Distribution and Dynamics of the Total Bacterial Number in the Kyongan Stream and Paltang Reservoir)

  • 박경미;황순진;조경제;신재기
    • 생태와환경
    • /
    • 제34권2호통권94호
    • /
    • pp.119-125
    • /
    • 2001
  • 경안천과 팔당호 주요 유입부에서 2000년 9월부터 2001년 2월까지 수중 총세균수의 분포 및 변동을 조사하였다. 경안천 본류에서 총세균수는 하수처리장 배출수가 유입될 때 뚜렷이 증가하였다. 경안천 본류에서 유하거리 (km)당 총세균의 소멸량은 0.13${\times}10^{6}$cells/ml로서 하류로 이송되면서 하상에 침강 소멸되는 양이 상당하였다. 총세균수의 변동은 9${\sim}$10월, 11월 및 12${\sim}$2월에 평균값이 각각 1.74${\sim}$3.10${\times}10^{6}$cells/ml, 1.86${\sim}$7.30${\times}10^{6}$cells/ml 및 4.56${\sim}$8.75${\times}10^{6}$cells/ml 범위로서 세균의 생물량은 고수온기에 적었고 저수온기에 오히려 증가하였다. 총세균수는 수온이 >$10^{\circ}C$인 시기(9${\sim}$10월)보다 <$10^{\circ}C$인 저수온기(12${\sim}$2월)에 2.1${\sim}$3.0배 풍부하였다. 총세균수로 평가하였을 때 수질은 부영양상태였고 하수처리장 배출수는 경안천과 팔당호의 미생물 오염에 대한 가장 큰 source로 평가되었다. 경안천 뿐만 아니라 팔당호의 상수원 수질을 보호하기 위해서는 하수처리장 배출수 관리에 대한 대책 마련이 매우 시급한 것으로 판단되었다.

  • PDF

간헐 주입 2단(수직 및 수평 흐름) 모래 갈대 인공습지에 의한 생활하수 처리 (Evaluation of Combined Vertical and Horizontal Flow Sand-Filled Reed Constructed Wetland with Intermittent Feeding for Sewage Treatment)

  • 서정윤
    • 한국습지학회지
    • /
    • 제16권2호
    • /
    • pp.261-268
    • /
    • 2014
  • 본 연구의 목적은 직렬연결 2단 수직 및 수평 모래 갈대 인공습지에 생활하수를 간헐적으로 주입하였을 때 각 수질항목별 처리효율을 평가하는 것이다. 하수는 수리학적 부하량 $314L/m^2{\cdot}day$(수직 흐름 인공습지 기준)를 하루 4(10분 동안 주입후 5시간 50분 동안 중단)회 균등하게 간헐적으로 주입하였다. 평가 결과 pH는 유입수(7.27)보다 수직 흐름 인공습지 유출수(5.81)에서 감소하였다가 수평 흐름 인공습지 유출수(6.40)에서 다시 증가하였다. DO의 농도는 유입수에 비하여 유출수에서 높았으며 겨울로 갈수록 증가하였다. 수직 흐름 인공습지의 산소 전달율 (oxygen transfer rate: OTR)은 $58.72gO_2/m^2{\cdot}day$ 그리고 수평 흐름 인공습지의 OTR은 $7.72gO_2/m^2{\cdot}day$이었다. 각 항목별 평균 처리효율은 SS 94.80%, BOD 90.77%, $COD_{Cr}$ 85.87%, $COD_{Mn}$ 87.72%, T-N 64.74%, $NH_4{^+}$-N 86.44%, T-P 87.70%이었다. 유출수중 T-N의 반 정도는 $NO_3{^-}$-N(7.21 mg/L)이었으며 $NO_2{^-}$-N은 평균 0.64 mg/L이었다.

모델링 기반의 선회와류식 SBR 공법이 적용된 하수처리장 및 마을하수도 동절기 총인 개선방안 연구 (Analysis on Retrofit Method to Improve TP treatment efficiency in Air-vent SBR process installed MWTP and RCSTP during winter based on Modeling)

  • 이현섭;임지열;길경익
    • 한국습지학회지
    • /
    • 제21권4호
    • /
    • pp.251-256
    • /
    • 2019
  • 상수원의 상류 및 인근 지역의 경우, 개발 제한으로 인해 상대적으로 하수도 보급률이 낮은 지역이 많다. 이는 지속적으로 상수원 오염에 영향 미치며 이를 방지하기 위한 방안으로 하수도 보급 및 기존 시설의 개선 등의 방안이 제시되고 있다. 본 연구에서는 안동댐과 임하댐 상류에 위치하고 있으며, 선회와류식 SBR공법이 도입된 A하수처리장 모델링을 통해 동절기 마을하수도 방류수 수질 개선 방안을 마련하기 위한 연구를 실시하였다. 5년(2012년 ~ 2016년)간의 운전자료를 바탕으로 모델 구축·검증을 실시하였다. 모델링 결과, SRT 조절을 통해 동절기 방류수 수질 개선이 가능할 것으로 분석되었으며, 각 방류수 수질 기준 별 개선 효과는 BOD 1.8%, COD 54.5%, SS 4.3%, T-N 0.8%, T-P 7.7%로 나타났다. 본 연구를 통해 도출된 동절기 하수처리장 방류수 수질 개선을 위한 방안은 유사한 공법이 도입된 하수처리장 및 마을하수도의 운영 개선방안으로 활용될 수 있을 것으로 판단된다.