• Title/Summary/Keyword: Efficiency-NTU

검색결과 87건 처리시간 0.02초

폴리염화알루미늄 과량주입에 의한 고(高) pH 원수의 수처리효율 개선 (Improvement of Water Treatment Efficiency by Poly Aluminum Chloride Overdosing in High pH Raw Water)

  • 임재철;김진근
    • 상하수도학회지
    • /
    • 제23권1호
    • /
    • pp.39-46
    • /
    • 2009
  • A method to improve water treatment efficiency by coagulant overdosing for high pH raw water at a drinking water treatment plant (WTP) which had no pH adjusting facilities was investigated. Poly aluminum chloride (PACl) was used for coagulant, and turbidity removal efficiency was evaluated as a function of PACl dosage increases. pH and turbidity of supernatant of jar-tester were 7.10 and 0.50 NTU respectively, when the turbidity, pH, alkalinity, water temperature, conductivity of raw water were 1.75 NTU, 9.38, 46.5 mg/L, $6.4^{\circ}C$, $400{\mu}s/cm$, respectively. Turbidity of settled water was reduced from 2.18 NTU to 0.28 NTU (87% reduction) when PACl dosage was increased from 16 mg/L to 45 mg/L at a full scale WTP. This can be attributed to the recovery of coagulant efficiency by pH reduction with the increase of coagulant dose, however coagulation efficiency was reduced with the formation of Al(OH)4- by PACl addition at higher pH. Coagulant overdosing was proven to be a rapid and effective method for high pH raw water, which can be applied at drinking WTP.

고탁도 원수의 침전효율 증대를 위한 수평류식 핀 경사판 적용에 관한 연구 (Application of Horizontal Flow Fins Inclined Plate for Sedimentation Efficiencies Improvement in River Water with High Turbidity)

  • 최정수;진오석;주현종
    • 대한환경공학회지
    • /
    • 제34권9호
    • /
    • pp.644-650
    • /
    • 2012
  • 본 연구에서는 고탁도 원수의 효율적인 처리를 위해 수평류식 핀 부착 경사판(HFIP)을 설치하여 그에 따른 적용성을 평가하는데 목적을 두었다. 실험결과는 저탁도 원수 유입의 경우 HFIP 적용 후에 0.34 NTU의 방류수질과 90.45%의 제거효율을 나타냈다. 고탁도 원수의 경우에는 0.75 NTU의 방류수질과 97.27%의 제거효율을 나타냈다. 방류수질 안정성 측면에서는 HFIP 적용 후 0.12 NTU(저탁도 원수), 0.75 NTU(고탁도 원수)의 표준편차를 보였으며, 설치 전과 비교하여 방류수질 변동 폭이 상당히 개선된 것으로 나타났다. 이러한 결과는 HFIP 설치로 인해 수류 속도 분포의 안정화와 침강효율이 증가하였기 때문인 것으로 판단된다.

진양호소수의 효과적인 정수처리를 위한 최적응집제 주입량 결정 -콜로이드성 오염물질 처리를 위한 응집제 주입효과- (Determination of Optimun Coagulant Dosage for Effective Water Treatment of Chinyang Lake -The Effect of Coagulant Dosing on Remoaval of Colloidal Pollutants-)

  • 이원규;조주식;이홍재;허종수
    • 한국환경과학회지
    • /
    • 제7권6호
    • /
    • pp.761-772
    • /
    • 1998
  • 상수원수의 효과적인 처리를 위한 최적 응집제 주입량을 결정하기 위하여 상수원수의 콜로이드성 오염물질 처리를 위한 Alum, PAC 및 PACS의 응집제 주입량별 탁도제거 및 원수특성변화를 조사한 결과는 다음과 같다. 최저 잔류탁도를 나타내는 최적 응집제 주입량은 원수의 탁도가 5NTU인 경우 Alum은 35mg/ι, PAC은 30mg/ι 및 PACS는 10mg/ι이었고, 원수의 탁도가 10NTU인 경우 Alum은 30mg/ι, PAC은 25mg/ι 및 PACS는 10mg/ι이었으며, 이때 침전시간 4분 및 8분대의 탁도제거율은 원수탁도 5NTU인 경우 Alum은 10 및 72%, PAC은 44 및 62%, PACS는 25 및 55%였고, 원수탁도 10NTU인 경우에는 Alum은 52 및 70%, PAC는 90 및 95%, PACS은 10 및 28%였다. PAC이 Alum 및 PACS에 비하여 floc형성속도와 침강성이 우수하고 탁도제거율도 높게 나타나 침전지내급수량 변동이 심하고 표면부하율이 과부하일 경우 PAC을 사용하는 것이 유리할 것으로 판단되었다. 원수의 탁도별 응집제 주입량에 따른 pH 및 알칼리도는 응집제 주입량이 증가할수록 감소되었으나 각 응집제 최대 주입량에서 pH는 음용수 수질기준인 pH 5.8이하로는 감소되지 않았으며, 알칼리도도 재탁현상이 일어날 수 있는 10mg/ι 이하로는 감소되지 않았다. 처리수준 잔류 Al은 원수탁도 5 및 10NTU인 경우 Alum과 PAC은 그 주입량이 저농도에서 고농도로 갈수록 잔류탁도가 감소함으로써 잔류 Al도 감소하였으나 PACS는 잔류탁도가 증가하는 주입량에서도 잔류 Al은 감소하였다. 수중 KMnO$_4$ 소비량은 응집제 주입량이 증가할수록 감소되었으며, 최저 잔류 탁도를 나타내는 최적 응집제 주입량에서의 KMnO$_4$ 소비량 감소율은 원수탁도 5NTU일 경우 PAC 39%, Alum 18% 및 PACS 11%였으며, 10NTU일 경우에는 PAC 42%, Alum 27% 및 PACS 36%로서 전반적으로 탁도제거율과 KMnO$_4$소비량간에는 일정한 경향이 없는 것으로 나타났다. 수중 TOC는 응집제 주입량이 증가함에 따라 약간씩 감소되었으나 응집제 주입량 30mg/ι 이후부터는 일정 수준으로 유지되었으며, 감소되는 정도는 PACS >PAC >Alum순이었다. 최저 잔류탁도를 나타내는 최적 응집제 주입량에서의 Zeta potential은 원수탁도가 5NTU일 경우 Alum, PAC 및 PACS 모두 -20mV∼-15mV사이였으며, 원수 탁도가 10NTU인 경우에는 0∼0.5mV 범위에 있는 것으로 나타나 응집제 종류 및 주입량이 상이하더라도 응집효율이 가장 양호한 상태에서의 Zeta potential은 일정한 범위내에 있는 것으로 나타났다.

  • PDF

판형 휜을 갖는 열교환기의 휜효율에 관한 수치해석적 연구 (Numerical study for the fin efficiency of the heat exchanger having plate fins)

  • 강희찬
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.903-911
    • /
    • 1999
  • This study is discussed about the heat transfer coefficient and the fin efficiency of the heat exchanger having plate fins. A new definition for the fin efficiency of the heat exchanger is proposed. More than one hundred cases were tested numerically for the plate fins having uniform and non-uniform heat transfer coefficient. The previous models for the fin efficiency and the pure heat transfer coefficient were applicable to the heat exchanger only when the NTU is very small. It was found that the fin efficiency of the heat exchanger was nearly the same as the normalized fin temperature. The present model could estimate the pure heat transfer coefficient within a few percent in the present test range of 0<NTU<2.5.

  • PDF

세라믹 정밀여과막 공정을 위한 최적 응집조건 (Optimum Coagulation Conditions for Ceramic Microfiltration Membrane Process)

  • 임재림;이경혁;이영주;박종율
    • 멤브레인
    • /
    • 제22권2호
    • /
    • pp.135-141
    • /
    • 2012
  • 본 연구는 Y 정수장의 세라믹 정밀여과막 공정을 위한 최적의 응집 조건을 도출하고자 수행되었다. 쟈테스트 결과 Y댐 원수의 pH를 7로 조정 시 응집효율이 가장 우수하였으며, 원수 탁도가 10 NTU 이하인 평상시 탁도 조건하에서 최적 응집제 주입량은 3 mg/L (as $Al_2O_3$)인 것으로 나타났다. 최적 응집제를 선정하기 위하여 응집제 종류(PAC, PACS (II), PAHCS)별로 미니모듈 실험장치를 이용하여 평가한 결과 PAC를 주입하고 원수 pH를 7로 조정한 경우 비여과유속 감소율이 가장 낮은 것으로 나타났다. 원수 탁도를 10~150 NTU로 변화시키며 미니모듈에서 비여과유속 감소율을 평가한 결과 원수탁도 10~30 NTU 조건에서는 응집제 주입량 증가에 따라 비여과유속 감소율이 크게 감소하였으나 원수탁도가 50 NTU 이상에서는 응집제 주입량을 증가시켜도 비여과유속 감소율에 큰 차이가 없는 것으로 나타났다. 따라서 Y 정수장을 위해서 는 원수탁도 10 NTU 이하에서는 PAC (11% as $Al_2O_3$) 30 mg/L, 10~50 NTU에서는 30~50 mg/L, 50 NTU 이상에서는 50 mg/L이 적절하다.

밀폐형 차량 냉각시스템에 대한 열평형 연구 (A Study on the Heat Balance of Cooling System for Armored Vehicles)

  • 김성광;안석환;남기우
    • 동력기계공학회지
    • /
    • 제11권1호
    • /
    • pp.70-75
    • /
    • 2007
  • Heat transfer coefficient and fin efficiency of a heat exchanger dispersed in the microelement of control volume were predicted with various flow patterns, conditions and material properties. A computational program was developed by using the method of efficiency-NTU(Number of transfer unit). The modelling was applied to heat exchangers, also was integrated in power pack cooling system in an armored vehicle. The compatibility and the generality were proved by comparing the prediction values with the test results. The developed program may be useful for the design of the cooling system in an armored vehicle.

  • PDF

POTABLE WATER TREATMENT BY POLYACRYLAMIDE BASE FLOCCULANTS, COUPLED WITH AN INORGANIC COAGULANT

  • Bae, Young-Han;Kim, Hyung-Jun;Lee, Eun-Joo;Sung, Nak-Chang;Lee, Sung-Sik;Kim, Young-Han
    • Environmental Engineering Research
    • /
    • 제12권1호
    • /
    • pp.21-29
    • /
    • 2007
  • For this study, we polymerized polyacrylamide base flocculants (PAA) and tested their properties and settling efficiency as a treatment for potable water. The most common chemicals for potable water treatment in Korea are alum or PAC. However, due to various reasons (such as rainy season or algae), inorganic flocculants cannot be solely depended on to solve all the problems caused by the poor quality of inflow water. When PAA coupled with coagulants in a potable water purification process is used, the turbidity removal efficiency increases by a factor of three on a single chemical system using PAC (Raw water: 5.21 NTU; Treated PAA+PAC: 0.34 NTU; and, Treated PAC: 1.04 NTU). It is possible to offset the toxic effect of residual monomers in treated water using PAA, because the concentrations of residual acrylamide are less than 400 mg/L in the polymer itself and less than $0.04\;{\mu}g/L$ in the treated water base at a dosage of 0.1 mg/L. Therefore, PAAs may be a workable, and dependable, potable water treatment process for the high pollutant level of resource water.

백연 방지를 위한 NWD냉각탑의 성능해석에 관한 수치해석적 연구 (A Numerical Study on the Performance Analysis of the Plume Abatement NWD Cooling Tower)

  • 최창혁;최영기;소헌영
    • 설비공학논문집
    • /
    • 제13권11호
    • /
    • pp.1049-1058
    • /
    • 2001
  • The performance and design analysis for a NWD cooling tower using a combined wet and dry type fill are numerically investigated and compared with the experimental results. The Stoecker's method is applied to the wet section and LMTD or NTU-Effectiveness method to the wet and dry sections. The efficiency ratio of the NWD cooling tower to a wet type crossflow cooling tower is 59.34%. The predicted result shows a good agreement with the experimental data within 1.4% error. Plume abatement is far better with a NWD cooling tower than a counterflow cooling tower. It costs less than a conventional wet/dry tower because the finned exchanger is eliminated. This method also leaves out complexity in structure and Intricacy in operation.

  • PDF

플럭크기를 이용한 응집공정 진단에 관한 연구 (Study of the Floc Size Distribution for the Efficiency Assessment of Flocculation Process in Water Works)

  • 정진홍;최계운;박재로
    • 한국산학기술학회논문지
    • /
    • 제15권12호
    • /
    • pp.7438-7442
    • /
    • 2014
  • 정수처리공정 중 응집공정의 효율을 평가하기 위하여 Floc Size 분포를 분석하여 응집공정의 효율 평가를 수행하였다. 응집 효율은 탁도를 기준으로 평가하는 방법보다 응집 상태를 직접 평가하는 Floc의 크기 및 개수를 분석하여 정량화하는 기법을 제시하였다. 원수의 탁도 분포에 따른 Floc의 성장 상태를 분석하였다. 응집지에서 원수 탁도가 5.0 NTU 내외로 유입되었을 경우 응집지 각 단의 G값이 각각 50 sec-1,, 30 sec-1, 10 sec-1일 때 효율이 가장 높게 나타났으며, 원수 탁도가 263 NTU로 유입되었을 경우 G값을 각각 65 sec-1, 40 sec-1, 10 sec-1으로 운전한 경우 효율이 가장 높게 나타났으며, 이때 $1200{\mu}m$ 이상의 Floc 개수는 약 14개로 분석되었다. G값에 따라 응집효율을 평가할 수 있는 지표인자로 Floc의 크기 및 개수로 공정 진단 수행이 가능할 것으로 판단된다.

"TiO2 촉매막+UV+H2O2" 고도산화법(AOP)을 이용한 페놀 분해 (Degradation of Phenol by "TiO2 Ceramic Membrane+UV+H2O2" AOP)

  • 정연규;김진욱
    • 대한토목학회논문집
    • /
    • 제14권3호
    • /
    • pp.645-654
    • /
    • 1994
  • 광촉매 산화반응의 기본 운영조건-재순환을 속도 275 mL/min, 산소 공급량 2LPM, $UV+TiO_2+H_2O_2$(500 mg/l)을 새로운 광촉매 산화반응에 의한 유기물질 분해 수처리 공정으로 적용하였다. 탁도와 부유물질의 농도가 증가함에 따라 탁도 10 NTU-부유물질 농도 29 mg/l까지는 페놀분해가 감소하지 않고 약간 증가하는 추세를 보였고, 탁도 50 NTU-부유물질 농도 170 mg/l까지는 어느정도 페놀분해가 감소하고 있으나 탁도와 부유물질이 없는 경우와 비슷한 정도로 페놀 분해가 이루어졌다. 페놀 분해율은 유입페놀 농도가 증가할수록 감소하였다. 본 연구에서 이용한 $UV+TiO_2+H_2O_2$ 광촉매 산화반응은 정수처리공정의 고도산화법, 생물학적 폐-하수 처리의 후처리 공정으로 이용 가능할 것으로 판단된다.

  • PDF