• Title/Summary/Keyword: Efficiency Correlation Equation

Search Result 66, Processing Time 0.028 seconds

Rediction of Stage Efficiency Variation of a USC High Pressure Steam Turbine by Computational Fluid Dynamics (유동해석을 이용한 고압증기터빈 단효율 변화 예측)

  • Kang, Soo Young;Jang, Hyuck Jun;Lee, Jeong Jin;Kim, Tong Seop;Park, Seong Jin;Hong, Gi Won
    • The KSFM Journal of Fluid Machinery
    • /
    • v.20 no.2
    • /
    • pp.17-25
    • /
    • 2017
  • Prediction of performance and operating characteristics of a state-of-the-art ultra-supercritical (USC) steam turbine is an important issue in many ways. Theoretical and empirical correlation equations, developed a few decades ago, have been widely used in commercial programs for a prediction of performance. To improve of these correlation equations and apply them to the high pressure turbine of a USC steam turbine, computational fluid dynamic analysis was carried out and correlation equations to calculate efficiency variation of each stage were made. Both fluid dynamic characteristic and thermodynamic performance was analyzed for the development of the correlation equations. In particular, the impact of flow addition through an overload valve (OLV) between stages was examined throughly. The trend of pressure drop due to the flow mixing by the OLV flow addition was analyzed and an efficiency correlation equation considering the OLV flow was also made.

A Study on Internal Loss Analysis of Totem Pole Bridgeless PFC and Efficiency Improvement using Parallel Switch (토템폴 브릿지리스 PFC의 내부 손실 분석과 병렬 스위치를 사용한 효율 개선에 관한 연구)

  • Yoo, Jeong Sang;Gil, Yong Man;Yu, Seung Hyup;Ahn, Tae Young
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.4
    • /
    • pp.22-27
    • /
    • 2020
  • In this paper, a generalized efficiency equation was proposed to estimate the internal loss of the SMPS (switched-mode power supply) with 3 variables. The first variable was an internal loss not related to the load current such as auxiliary power, the second was a loss proportional to the current such as diode loss, and the third was a loss proportional to square of the current such as conduction loss. Especially, theoretical internal losses of the totem pole bridgeless PFC which is widely used for high efficiency SMPS were expressed as output function to compare generalized efficiency equation. In addition, in order to reduce the conduction loss of the switch, when a multiple switch were paralleled, the correlation with the efficiency was analyzed and shown as a graph. In order to confirm the degree of the parallel switch structure on the efficiency improvement, a 2kW class totem pole bridgeless PFC was constructed and the effectiveness of the analysis was confirmed by comparing the generalized efficiency equation and theoretical loss analysis results with experimental data.

Solution of Fuzzy Relation Equations Using Duality of Operators

  • Lai, Edmund;Park, Chan-Gook
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.106.2-106
    • /
    • 2001
  • The two typical composite operations of fuzzy relation are the max-min and the min-max composite operations. It is known that the two operations can be completely dual. This paper pays attention to the nature that these two typical operations are completely dual and investigates the correlation between the max-min composite relation equation and the min-max composite relation equation. An important scheme of correlation is in the characteristic of solution sets derived from these two fuzzy relation equations. The paper explains that one of the composite fuzzy relation equations is solvable using the solution method of the other fuzzy relation equation. The above-mentioned duality plays an important role in this solution procedure. Since it is not necessary to build the solution method separately like before, calculation efficiency can be raised. Moreover, the solution for the relation ...

  • PDF

Heat Transfer Characteristics in a Cylindrical Duct Packed with Solid Spheres

  • Lee, Seung-Hyuk;Kang, Kwan-Gu;Kim, Sung-Chan;Ryou, Hong-Sun;Noh, Dong-Soon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.1
    • /
    • pp.11-21
    • /
    • 2005
  • The present paper investigates the heat transfer characteristics in a cylinder packed with porous medium of solid spheres for various parameters such as mass flow rate, sphere diameter, length of the porous medium, and gas temperatures. Pressures and temperatures at the inlet and outlet regions were measured by using static pressure gages and R-type thermocouples. The modified relationship based on the Ergun equation is suggested for the estimation of pressure drops. In addition, the useful empirical correlation for thermal efficiency is obtained in the current study. Thermal efficiency is expressed in terms of non-dimensional time, sphere diameter, porosity, and pressure drops. It is also found that the pressure drop through the cylinder becomes larger as the gas temperature does higher at the inlet region, whereas it substantially decreases when the inlet flow rate decreases.

A Numerical Study on Plastic Shrinkage Cracking of Concrete Slabs (콘크리트 슬래브의 소성수축균열에 대한 해석적 연구)

  • Kwak-Hyo-Gyoung;Ha, Soo-Jun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.785-788
    • /
    • 2005
  • In this paper, the influence of many factors related to the concrete mixture and the weather condition on plastic shrinkage cracking are analyzed through parametric studies using the numerical models introduced in the companion paper. First of all, through a systematic calculation of bleeding, the relationship between the bleeding constants and concrete mixture is proposed on the basis of the experimental data obtained by many researchers. Moreover, an equation, which can directly determine a critical point at which the evaporation and bleeding is balanced, is introduced, and the efficiency of the introduced equation is verified through the correlation study between the obtained results by the introduced equation and those by the rigorous analyses. The introduced equation can effectively be used to predict and to prevent plastic shrinkage cracking without any rigorous analysis and, in advance, to cope with the sudden changes in the concrete mixture and/or weather condition.

  • PDF

FINITE DIFFERENCE METHOD FOR THE TWO-DIMENSIONAL BLACK-SCHOLES EQUATION WITH A HYBRID BOUNDARY CONDITION

  • HEO, YOUNGJIN;HAN, HYUNSOO;JANG, HANBYEOL;CHOI, YONGHO;KIM, JUNSEOK
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.23 no.1
    • /
    • pp.19-30
    • /
    • 2019
  • In this paper, we develop an accurate explicit finite difference method for the two-dimensional Black-Scholes equation with a hybrid boundary condition. In general, the correlation term in multi-asset options is problematic in numerical treatments partially due to cross derivatives and numerical boundary conditions at the far field domain corners. In the proposed hybrid boundary condition, we use a linear boundary condition at the boundaries where at least one asset is zero. After updating the numerical solution by one time step, we reduce the computational domain so that we do not need boundary conditions. To demonstrate the accuracy and efficiency of the proposed algorithm, we calculate option prices and their Greeks for the two-asset European call and cash-or-nothing options. Computational results show that the proposed method is accurate and is very useful for nonlinear boundary conditions.

An Experimental Study on Air Leakage and Heat Transfer Characteristics of a Rotary-type Heat Recovery Ventilator

  • Han, Hwa-Taik;Kim, Min-Kyu
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.2
    • /
    • pp.83-88
    • /
    • 2005
  • This study investigates the air leakage and heat transfer characteristics of a commercially available rotary-type air-to-air heat exchanger with a fiber polyester matrix. Crossover leakage between the exhaust and supply air is measured using a tracer gas method for various ventilation rates and rotational speeds of the wheel. A correlation equation for the leakage is obtained by summing up pressure leakage and carryover leakage. The pressure leakage is observed to be a function of ventilation rate only, and the carryover leakage is found to be a linear function of wheel speed. The real efficiency of the heat exchanger can be obtained from its apparent efficiency by taking into account the leakage ratio. The heat recovery efficiency decreases, as the ventilation rate increases. As the wheel speed increases, however, the efficiency increases initially but reaches a constant value for the speeds over 10rpm.

An Experimental Study on Heat Transfer Performance of Heating Medium Oil Fluidized Bed Heat Exchanger (열매체유 유동층 열교환기의 전열성능에 대한 실험적 연구)

  • Park, Sang-Il;Ko, Chang-Bok;Lee, Young-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.3
    • /
    • pp.146-151
    • /
    • 2015
  • The heat transfer performance of heating medium oil fluidized bed heat exchanger was measured. The operation variables were air flow rate, air inlet temperature, moisture content, water flow rate and water inlet temperature. The outside heat transfer coefficient was determined from the heat exchanger experiment and its experimental correlation was determined as a function of air velocity and viscosity of heating medium oil. Effect of viscosity was well agreed with the previous studies. Errors of the correlation equation was less than about 10% for outside heat transfer coefficient developed in this study when compared with the measured value. Hot water with the temperature greater than $77^{\circ}C$ could be produced by using the heating medium oil fluidized bed heat exchanger.

Optimum Water Quality Contral of River Basin by Linear Programming (선형계획법에 의한 하천유역의 최적수질관리)

  • 김상근;이순택
    • Water for future
    • /
    • v.16 no.3
    • /
    • pp.159-169
    • /
    • 1983
  • In this paper, a linear programming was used for determining the optimum efficiency required of each wastwater treatment facility and minimum total treatment casts in order to meet any set of stream dissolved oxygen standards within a river basin. The optimum solution of water quality control which was obtained with the inventory equation of Camp-Dobbins' equation incorporated into the constraints of linear programming was compared with that of Streeter-Phelps' equation. It can be concluded that correlation coefficient was 0.997. Then the linear programming incorporating the inventory equation of selected streeter-Phelps equation was used in order to obtain the optimum solution of water quality control based on data form the Nakdong River.

  • PDF

A Study on Removal Efficiency of Cd by using Chitosan Complex isolated from Aspergillus oryzae (Aspergillus oryzae로부터 분리한 chitosan복합체에 의한 카드뮴 제거 효율에 관한 연구)

  • 장재선;이제만;김용희
    • Journal of environmental and Sanitary engineering
    • /
    • v.19 no.1
    • /
    • pp.37-41
    • /
    • 2004
  • The removal efficiency of cadmium by chitosan complex isolated from Aspersillus oryzae was investigated through laboratory experiments. The results of the study are as follows. The adsorption kinetics of cadmium was reached the adsorption equilibrium in approximately 20 minutes and the removal efficiency was showed 95.8%. The effect of temperature on cadmium adsorption by chitosan complex shows that as the temperature increased, the amount of cadmium adsorption per unit weight of chitosan complex increased. The correlation between amount of cadmium adsorption per unit weight of chitosan complex and temperature was obtained through the coefficient of determination($R^2$). $R^2$ values was 0.854(p<0.05). A linearized Freundlich equation was used to fit the acquired experimental data. As a result, Freundlich constant, the adsorption intensity(1/n) was 0.550, and the measure of adsorption(k) was 2.181. So, it was concluded that adsorption of cadmium by chitosan complex is effective.