• Title/Summary/Keyword: Effective tube

Search Result 826, Processing Time 0.035 seconds

Flow-induced instability and nonlinear dynamics of a tube array considering the effect of a clearance gap

  • Lai, Jiang;Sun, Lei;Li, Pengzhou
    • Nuclear Engineering and Technology
    • /
    • v.51 no.6
    • /
    • pp.1650-1657
    • /
    • 2019
  • Fluidelastic instability and nonlinear dynamics of tube bundles is a key issue in a steam generator. Especially, once the post-instability motion of the tube becomes larger than the clearance gap to other tubes, effective contact or impact between the tubes under consideration and the other tube inevitable. There is seldom theoretical analysis to the nonlinear dynamic characteristics of a tube array in two-phase flow. In this paper, experimental and numerical studies were utilized to obtain the critical velocity of the flow-induced instability of a rotated triangular tube array. The calculation results agreed well with the experimental data. To explore the post-instability dynamics of the tube array system, a Runge-Kutta scheme was used to solve the nonlinear governing equations of tube motion. The numerical results indicated that, when the flow pitch velocity is larger than the critical velocity, the tube array system is undergoing a limit cycle motion, and the dynamic characteristics of the tube array are almost similar for different void fractions.

Derivation of the Effective Energy Calculation Formula of the X-ray Beam Generated by the CT Simulator (CT 모의치료장치에서 발생된 X-선 빔의 유효에너지 계산식 유도)

  • Kim, Jong-Eon;Lee, Sang-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.869-875
    • /
    • 2021
  • The purpose of this study is to derive a formula for calculating the effective energy of an X-ray beam generated by a CT simulator. Under 90, 120, and 140 kVp X-ray beams, the CT number calibration insert part of the AAPM CT performance phantom was scanned 5 times with a CT simulator. The CT numbers of polyethylene, polystyrene, water, nylon, polycarbonate, and acrylic were measured for each CT slice image. The average value of CT number measured under a single tube voltage and the linear attenuation coefficients corresponding to each photon energy calculated from the data of the National Institute of Standards and Technology were linearly fitted. Among the obtained correlation coefficients, the photon energy having the maximum value was determined as the effective energy. In this way, the effective energy of the X-ray beam generated at each tube voltage was determined. By linearly fitting the determined effective energies(y) and tube voltages(x), y=0.33026x+30.80263 as an effective energy calculation formula was induced.

Parametric Study on Performance of Inertance Pulse Tube Cryocooler

  • Lee, K.H.;Rhee, J.;Kim, J.S.
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.15 no.2
    • /
    • pp.205-211
    • /
    • 2014
  • The design parameters to affect the cooling capacity of a cryocooler were examined with the application of numerical modeling to optimize an inertance pulse tube cryocooler. This modeling includes the regenerator, pulse tube, inertance tube, gas reservoir, and heat exchangers. One-dimensional modeling on strings of acoustic and thermoacoustic elements was applied to compare the design parameters. The diameter and length of the pulse tube can significantly affect the cooling capacity and efficiency. The aftercooler was optimized by maintaining a certain size. The efficiency also improved as the length of inertance tube and volume of gas reservoir are increased. It was confirmed that effective design parameters are critical to the performance of an inertance pulse tube cryocooler considering the comparison of the dimensions of each part to optimize its cooling power and efficiency.

Analysis and Dynamic Modeling of a High-speed Tube Expander (고속 Tube Expander의 동적 모델링 및 해석)

  • 김재량;정원지;김수태;최욱환
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.401-411
    • /
    • 2003
  • Tube expanding process is for combining a heat-sink plate with hair-pins (Cu-tube) through plastic deformation. The two parts, i. e. , heat-sink plate and hair-pins are they components of a heat-exchanger for an air conditioner. This paper presents the analysis and dynamic modeling of a high-speed tube expander which integrates transfer of parts, fixing of parts, and tube expanding into one process. The 3-dimensional modeling of all the parts for the tube-expander was constructed using CATIA$\circledR$. then the CATIA$\circledR$ models are transferred into visuaINastran$\circledR$ to execute the 3-dimensional animation for checking prescribed cycle-time. The technique presented in this paper has been shown to be effective as a priori tool for verifying the design of a high-speed tube expander.

  • PDF

A Novel Mediastinal Drainage Tube for Mediastinitis

  • Yhang, Jun Ho;Jang, In-Seok;Kim, Sung Hwan;Park, Hyun Oh;Kang, Dong Hoon;Choi, Jun Young
    • Journal of Chest Surgery
    • /
    • v.48 no.5
    • /
    • pp.378-379
    • /
    • 2015
  • Mediastinitis is a life-threatening disease, and effective drainage is needed to treat mediastinitis with abscess formation. We recommend an alternative drainage method using chest tube binding with a Silastic Penrose drainage tube. The use of a Silastic Penrose drainage tube may help to manage mediastinitis with abscess formation. This method facilitates effective draining and prevents tissue adhesion.

Development of magnesium tube manufacturing technology with strip cast and warm rolled AZ31 sheet. (마그네슘 압연판재를 이용한 용접 튜브 제조 기술 개발)

  • Lee, Mok-Young;Han, Soo-Sik;Chang, Woong-Seong;Lee, Heung-Gyu
    • Proceedings of the KWS Conference
    • /
    • 2010.05a
    • /
    • pp.96-96
    • /
    • 2010
  • Magnesium alloy is being used for structural material since it has high specific strength. Tubular shape was effective way for enhanced structural design. To manufacture the tube, it is necessary to weld the butted joint of both tubular formed sides. But the magnesium alloy was hardly welded with conventional welding processes. The laser welding was effective way to joint magnesium alloys because it had high weld strength and productivity compare with other welding processes. In this study, magnesium alloy sheets was formed at elevated temperature to tubular shape and welded with laser. Consequently, the magnesium alloy tube was making successful with warm forming and laser welding and bicycle frame was making with it.

  • PDF

The effect of the number of nozzle holes on the energy separation (보텍스튜브의 노즐홀수가 에너지분리에 미치는 영향)

  • 유갑종;이진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.5
    • /
    • pp.692-699
    • /
    • 1999
  • The vortex tube is a sample device for separating a compressed gaseous fluid stream into two flows of high and low temperature without any chemical reactions. The phenomena of energy separation through the vortex tube were investigated experimentally, to see the effects of the number of nozzle holes on the energy separation. The experiment was carried out with the number of nozzle holes from 1 to 10 by varying inlet pressure and cold mass fraction. The experimental results were indicated that the effective number of nozzle holes for the best cooling performance was found as 4. Also, to find effective use in a given operation conditions, the temperature difference of cold air and the cooling capacity of vortex tube was compared. The result is that cooling capacity was more important than temperature difference of cold air.

  • PDF

Convection Effects on PGSE-NMR Self-Diffusion Measurements at Low Temperature: Investigation into Sources of Induced Convective Flows

  • Chung, Kee-Choo;Yu, Hyo-Yeon;Ahn, Sang-Doo
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.6
    • /
    • pp.1970-1974
    • /
    • 2011
  • The effects of convection on the measurement of the diffusion coefficients of liquids by the pulsed gradient spin echo (PGSE) NMR method at low temperature are discussed. To examine the generation of convective flows, we used four different types of sample tubes in the diffusion measurements with temperature variation; a normal 5 mm NMR tube, a Shigemi tube, an ELISE type tube, and a capillary tube. Below room temperature, the calculated diffusion coefficients of chloroform in 5 mm o.d. type tubes increased with decreasing temperature, while those in the capillary tube decreased linearly. The convective flow was found to be significant even at low temperature and it seemed to be mainly induced by the transverse temperature gradient. It was also found that the capillary tube was most appropriate to measure the diffusion coefficients, since its small diameter is effective in suppressing the convective flows at both high and low temperatures.

Study on Transient Flow in Pipeline with Flexible Tube (탄성관을 삽입한 관로에서의 비정상류에 관한 연구)

  • Kim, Young-Joon;Tsukamoto, Hiroshi
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.825-828
    • /
    • 2005
  • Experimental and numerical study was done to confirm the effect of the flexible tube in pipeline on transient flow oscillation. Experiment was made for a pipeline with and without deformable flexible tube using a single pumping system of main stainless pipe. The wave speeds of main pipe and flexible tube were calculated from the pipe material properties, structures, and boundary conditions. Time dependent pressure fluctuations were calculated for the pipeline using the simple and the Kelvin-Voigt viscoelastic models for the deformation of main pipe and flexible tube. Pressure calculated by the Kelvin-Voigt viscoelastic model showed better agreement with measured one than pressure by the simple model. Experimental and numerical results show that the maximum pressure as well as amplitude of pressure oscillation was decreased by inserting short flexible tube in pipeline. Hence, inserted short flexible tube to pipeline was found to be effective for the suppression of strong pressure oscillation. Moreover, the wave speed in pipe was discussed based on numerical and experimental results.

  • PDF

Manufacturing of High-Performance Double Layered Tube with Corrugated Internal Pattern via the Hydroforming Process (액압 성형을 이용한 내부복합파형 고효율 이중관 제조 기술)

  • Han, S. W.;Kim, D. Y.;Moon, Y. H.
    • Transactions of Materials Processing
    • /
    • v.31 no.3
    • /
    • pp.143-150
    • /
    • 2022
  • The purpose of this study was to investigate an innovative hydroforming process for the cost-effective manufacturing of double layered tube with circumferentially corrugated patterns. Conventional double pipe heat exchanger has relatively poor heat transfer efficiency because of the limited contact area resulting from the concentrically arranged simple cylindrical structure. As a promising alternative to enhance heat transfer efficiency, double layered tube with corrugated internal pattern was considered in this study. To fabricate corrugated inner tube, innovative tube hydroforming system was developed. The customized loading paths were established using the simulated forming pressure and contracting stroke at various bar diameters. Experimentally obtained cross-sectional profiles were analyzed to evaluate the reliability and applicability of the hydroformed tube with various patterns. The results demonstrate that the proposed hydroforming process can be a feasible alternative for manufacturing high-performance double-tube heat exchangers.