• 제목/요약/키워드: Effective temperature

검색결과 5,777건 처리시간 0.038초

소규모 사무실의 조명 색 변화에 따른 시각적 감지 및 무드 변화 분석 (Analysis on Visual Perception and Mood for Color of Light in a Small Office)

  • 강민혜;김수영
    • 설비공학논문집
    • /
    • 제23권4호
    • /
    • pp.287-296
    • /
    • 2011
  • This study examines the influences of correlated color temperature and illuminance on visual perception and temporary mood sensation in a small office. Field measurements and surveys were conducted in a full-scale mock-up model. Twenty subjects participated in the survey under six lighting conditions formed by three color temperature and two illuminance levels. Results indicate that 4000 K color temperature was effective to mitigate glare sensation from light source. Lamps with low color temperature such as 2700 K was not recommended for office lighting since they are likely to caused glare and visual discomfort. Preferred color temperature was 4000 K and 6500 K for 750 lx and 500 lx target illuminance respectively. The increase of illuminance was not an effective contributor to improve mood perception. The illuminance should be lower than 500 lx to achieve good mood, but the illuminance level in office space should be considered with visual performance simultaneously. This study suggests that fluorescent lighting fixtures with 4000 K lamps would be usefully used for office lighting since they formed friendly conditions for better visual performance.

발반사 마사지가 재가 여성노인의 수면, 우울 및 피부온도에 미치는 효과 (The Effects of Foot Reflexology on Sleep, Depression and Skin Temperature of the Female Elderly at Home)

  • 김정순;홍세화;김세령;김여진
    • 지역사회간호학회지
    • /
    • 제22권4호
    • /
    • pp.409-419
    • /
    • 2011
  • Purpose: The purpose of this study was to examine the effects of foot reflexology on sleep, depression and skin temperature of the female elderly at home. Methods: This research used the non-equivalent control group pretest-posttest design. The participants were 45 elders residing at home: 23 in the experimental group and 22 in the control group. The experimental group received 30-minute foot reflexology 8 times for 2 weeks. The results were analyzed using ${\chi}^2$ test, t-test with the SPSS/WIN 12.0 program. Results: The results showed that foot reflexology was significantly effective in improving the quality of sleep, reducing depression, and raising the temperature of both feet. However, the temperature of both palms was not statistically significantly different between the two groups. Conclusion: The results of this study indicated that foot reflexology is an effective nursing intervention in improving the quality of sleep, reducing depression, and raising the temperature of both feet. Therefore, it is recommended to use foot reflexology as a complementary nursing intervention for elderly women at home in community.

토지이용 및 토지피복과 국지온도 간 관계 분석: 미시공간에서의 통합모델 구축을 중심으로 (Analyzing Relationship between the Local Temperature, Land Usage and Land Coverage: Focused on the Integrated Model in the Microspace)

  • 박유나;이건원;정윤남;김세용
    • KIEAE Journal
    • /
    • 제14권5호
    • /
    • pp.123-130
    • /
    • 2014
  • In order for effective heat island reduction policies to be proposed, this research made use of the land usage and land coverage and Temperature of cities, Coordinate axis data within 500 meters of nationwide automatic weather stations (478 points) in order to analyze the correlation of summertime temperatures through multiple regression analysis. This research also developed a model and empirically analyzed the urban heat island reduction effect of factors that affect regional temperatures. Heat islands cause environment deterioration and therefore can harm citizens' health, and also affects the city's metabolism process. Thus in order to restrain regional temperature rises the conclusion was drawn that consideration to increase forest areas on part of land usage planning is needed. Appropriate policy measures to regulate traffic related factors are also needed to restrain regional temperature rises. In order for future heat island reduction this research proposes a way to set up more effective policies and urban sustainability improvement strategies, and is significant in that it makes use of detailed data such as land usage and land coverage, Temperature of cities, Coordinate axis in analyses.

Effect of Counter Anions on Solid Electrolyte Interphase Formation on Graphite Electrodes in Propylene Carbonate-based Electrolyte Solutions

  • Song, Hee-Youb;Kim, Seong In;Nogales, Paul Maldonado;Jeong, Soon-Ki
    • Journal of Electrochemical Science and Technology
    • /
    • 제10권1호
    • /
    • pp.55-60
    • /
    • 2019
  • Herein, the effect of counter anions on the formation of a solid electrolyte interphase (SEI) in a propylene carbonate (PC)-based electrolyte solution was investigated. Although the reversible capacities were different, reversible intercalation and de-intercalation of lithium ions occurred in the graphite negative electrode in the PC-based electrolyte solutions containing 1 M $LiClO_4$, $LiPF_6$, $LiBF_4$, and $LiCF_3SO_3$ at low temperature ($-15^{\circ}C$). This indicated that the surface films acted as an effective SEI to suppress further co-intercalation and decomposition reactions at low temperature. However, the SEIs formed at the low temperature were unstable in 1 M $LiPF_6$ and $LiBF_4/PC$ at room temperature ($25^{\circ}C$). On the other hand, increasing reversible capacity was confirmed in the case of $LiCF_3SO_3/PC$ at room temperature, because the SEI formed at the low temperature was still maintained. These results suggest that counter anions are an important factor to consider for the formation of effective SEIs in PC-based electrolyte solutions.

Analyzing the Influence of Spatial Sampling Rate on Three-dimensional Temperature-field Reconstruction

  • Shenxiang Feng;Xiaojian Hao;Tong Wei;Xiaodong Huang;Pan Pei;Chenyang Xu
    • Current Optics and Photonics
    • /
    • 제8권3호
    • /
    • pp.246-258
    • /
    • 2024
  • In aerospace and energy engineering, the reconstruction of three-dimensional (3D) temperature distributions is crucial. Traditional methods like algebraic iterative reconstruction and filtered back-projection depend on voxel division for resolution. Our algorithm, blending deep learning with computer graphics rendering, converts 2D projections into light rays for uniform sampling, using a fully connected neural network to depict the 3D temperature field. Although effective in capturing internal details, it demands multiple cameras for varied angle projections, increasing cost and computational needs. We assess the impact of camera number on reconstruction accuracy and efficiency, conducting butane-flame simulations with different camera setups (6 to 18 cameras). The results show improved accuracy with more cameras, with 12 cameras achieving optimal computational efficiency (1.263) and low error rates. Verification experiments with 9, 12, and 15 cameras, using thermocouples, confirm that the 12-camera setup as the best, balancing efficiency and accuracy. This offers a feasible, cost-effective solution for real-world applications like engine testing and environmental monitoring, improving accuracy and resource management in temperature measurement.

서열 환경에서 농작업 모자 착용에 따른 체온 조절 및 주관적 반응 (Thermal and subjective responses by sun hats for farmer in a hot climatic chamber)

  • 김명주;최정화
    • 한국의류학회지
    • /
    • 제28권5호
    • /
    • pp.713-722
    • /
    • 2004
  • This study examined the effects of two kinds of functional sun hats through a head-manikin test and a climatic chamber trial for farm workers in summer. Experiment was composed of four conditions. The first condition was the condition without any hat (Control). The second was the condition with a sun hat on the market (Hat A). The third was the condition with a functional sun hat made of reflective fabric (Hat B). The last was the condition with a functional sun hat having a ventilating structure as well as reflective fabric (Hat C). For the subjects in the climatic chamber trials, 12 healthy males volunteered. Air temperature, relative humidity and globe temperature in the chamber was maintained at $33{\pm}0.5^{\circ}C,\;65{\pm}5%RH\;and\;39{\pm}1^{\circ}C\;(WBGT\;33^{\circ}C)$. Subjects did a simulated red pepper-work (50-min work and 10-min rest, twice repetition) for 120 min. As the result of head-manikin test, the surface temperature on middle of back-neck was the lowest in Hat B of four conditions and the surface temperature on top of head was the lowest in Hat C. As the result of climatic chamber trials, there were apparent differences between with (Hat A, Hat B, Hat C) and without a sun hat (Control). In rectal temperature ($T_{re}$), mean skin temperature ($\={T}_{sk}$), heart rate (HR), total sweat rate (TSR), The physiological heat strain was less in the condition with hats than in the condition without a sun hat. As the increasing rate in Tre, Hat B is the most effective hat for alleviation heat strain. As the subjective responses, Hat B was the most effective hat for thermal comfort even though the difference was not significant. Hat C was less effective than Hat B and the reason might be the increase of weight due to inserting the ventilating structure.

고기능성 세라믹 주형 및 중자 제작을 위한 3원계 무기 바인더 시스템 개발 (Development of Ternary Inorganic Binder System for Manufacturing High-Functional Ceramic Molds and Core)

  • 박혜영;조근호;최현희;김봉구;김은희;양승철;정연길
    • 한국재료학회지
    • /
    • 제32권12호
    • /
    • pp.538-544
    • /
    • 2022
  • In existing ceramic mold manufacturing processes, inorganic binder systems (Si-Na, two-component system) are applied to ensure the effective firing strength of the ceramic mold and core. These inorganic binder systems makes it possible to manufacture a ceramic mold and core with high dimensional stability and effective strength. However, as in general sand casting processes, when molten metal is injected at room temperature, there is a limit to the production of thin or complex castings due to reduced fluidity caused by the rapid cooling of the molten metal. In addition, because sodium silicate generated through the vitrification reaction of the inorganic binder is converted into a liquid phase at a temperature of 1,000 ℃. or higher, it is somewhat difficult to manufacture parts through high-temperature casting. Therefore, in this study, a high-strength ceramic mold and core test piece with effective strength at high temperature was produced by applying a Si-Na-Ti three-component inorganic binder. The starting particles were coated with binary and ternary inorganic binders and mixed with an organic binder to prepare a molded body, and then heat-treated at 1,000/1,350/1,500 ℃ to prepare a fired body. In the sample where the two-component inorganic binder was applied, the glass was liquefied at a temperature of 1,000 ℃ or higher, and the strength decreased. However, the firing strength of the ceramic mold sample containing the three-component inorganic binder was improved, and it was confirmed that it was possible to manufacture a ceramic mold and core via high temperature casting.

파밤나방 유충의 발율 및 성충의 수명과 산란에 미치는 온도의 영향 (Effects of Some Temperatures on Larval Development, Adult Longevity and Oviposition of the Beet Armyworm, Spodoptera exigua Hubner)

  • 최주수;박영도
    • 생명과학회지
    • /
    • 제10권1호
    • /
    • pp.1-6
    • /
    • 2000
  • Larval development, adult longevity and oviposition of the beet armyworm, Spodoptera exigua H bner was studied at 16, 20, 25 and 3$0^{\circ}C$ with a 16L: 8D photoperiod. Egg hatchability of S. exigua was the highest at 3$0^{\circ}C$ and reduced with decreasing temperature. Egg period was the shortest at 3$0^{\circ}C$ and prolonged with decreasing temperature. Percent pupation was became higher at higher temperature form 23.2% to 94.0%. Developmental period of larva was the shortest at 3$0^{\circ}C$, but extended with decreasing temperature. Adult emergence ratio was the highest at 3$0^{\circ}C$ and reduced with decreasing temperature. The mean pupal period was 35.2, 14.4, 7.8 and 5.0 days at 16, 20, 25 and 3$0^{\circ}C$, respectively. Relationships between constant temperature and the developmental velocity of egg, larva and pupa were linear. Developmental threshold temperature seems to be 13.3 8$^{\circ}C$ for egg, 14.02$^{\circ}C$ for larva, 14.09$^{\circ}C$ for pupa, and 13.84$^{\circ}C$ for egg the adult. Estimated value of the total effective temperature for completing each stage was 36.89 day-degree for egg, 155.72 day-degree for larva, 79.20 day-degree for pupa, and 273.41 day-degree for egg to adult. Female longevity varied to temperature from 11.4 days at 16$^{\circ}C$ to 5.8 days at 3$0^{\circ}C$, and male longevity was longer than that of female. Preoviposition period was the shortest at 3$0^{\circ}C$, but prolonged with decreasing temperature. It was about 2.7 times longer at 16$^{\circ}C$ than that at 3$0^{\circ}C$. Number of eggs per female was the highest at $25^{\circ}C$, followed by 20, 30 and 16$^{\circ}C$.

  • PDF

온도 측정을 통한 상용 쑥뜸의 자극효과에 대한 실험적 연구 - 승온속도 및 유효자극기를 중심으로 - (Experimental Study on the Stimulating Effect of Commercial Moxa Combustion through the Measurement of Temperature - Focused on ascending temperature gradient and effective stimulating period -)

  • 이건목;이건휘;이승훈;양명복;고기덕;서은미;장종덕;황병찬
    • Journal of Acupuncture Research
    • /
    • 제19권3호
    • /
    • pp.64-76
    • /
    • 2002
  • Objective : The purpose of this study is to investigate the mechanism and effect of moxibustion objectively and to be used as the quantitative data for developing the new thermal stimulating treatment by observing the combustion characteristics of commercial moxaes. Methods : We have selected two types(large-size moxa A(LMA), large-size moxa B(LMB)) among large moxaes used widely in the clinic. We examined combustion times, temperatures, temperature gradients in each period during a combustion of moxa. Results : 1. The ascending temperature gradient measured in the central point of non-contacted surface was fastest, the average ascending temperature gradient of both moxaes was $0.0384^{\circ}C/sec$, $0.0123^{\circ}C/sec$ respectively, 3.1 times faster in LMA. The maximum ascending temperature gradient was also about 2.9 times faster in LMA. The time required for the maximum ascending temperature gradient from ignition was 254sec, 411sec respectively. 2. The minimum descending temperature gradient in the retaining period was $-0.0250^{\circ}C/sec$, $-0.0090^{\circ}C/sec$ respectively and the average descending temperature gradient was $-0.0160^{\circ}C/sec$, $-0.0037^{\circ}C/sec$ respectively on the non-contact surface. 3. On the basis of the non-contact surface($A_I$), the time at which the effective stimulus period began to occur was about 264sec, 796sec respectively after an ignition, the time at which the maximum temperature began to occur was about 373sec, 1323sec respectively after an ignition, and the maximum temperature was $0.9^{\circ}C$ higher in LMA. The maximum ascending temperature gradient was also about 4.2 times faster in LMA. Conclusion : It was thought that not only the figure of moxicombustion device, but also the form and size of moxa had influence on the combustion characteristics deciding the performance of stimulus seriously.

  • PDF

암석시험편 유효공극률 측정의 반복성과 재현성 (Repeatability and Reproducibility in Effective Porosity Measurements of Rock Samples)

  • 이태종;이상규
    • 지구물리와물리탐사
    • /
    • 제15권4호
    • /
    • pp.209-218
    • /
    • 2012
  • 다양한 직경과 길이, 암종, 그리고 유효공극률을 가지는 8종의 암석시험편에 대하여 반복적으로 고체밀도와 유효공극률을 산출하고 그에 따른 반복성 및 재현성을 검토하였다. 또한 대기의 기온변화가 유효공극률의 산출에 미치는 영향에 대해 고찰하였다. 8종의 암석시험편에 대하여, 진공압력은 사용한 시스템의 최대진공인 1 torr로, 진공시간은 ISRM 표준시험법의 규약을 만족하는 80분으로 하여 유효공극률을 7번씩 산출하였다. 즉, 참조를 위해 각각의 시험편에 대해 1회, 반복성 검토를 위하여 모든 실험 조건을 같이한 상태에서 각 3회씩, 그리고 재현성의 검토를 위하여 동시에 수침진공하는 시험편의 숫자를 2, 4, 8개로 달리하여 3회 등 총 7번씩의 유효공극률을 산출하고 비교 검토하였다. 고체밀도의 경우 8개 암석시험편의 평균편차가 0.00 $g/cm^3$으로 나타나서 완벽한 반복성과 재현성을 보였다. 유효공극률의 경우는 모든 실험 조건을 동일하게 한 반복성 실험에서는 평균편차가 0.07% 이하, 실험 조건 중에 수침진공 하는 시험편의 숫자를 달리한 재현성 실험에서는 0.05% 이하로 모두 양호한 값을 나타내었다. 재현성 실험에 의해 측정된 유효공극률이 대부분 반복성 실험에서 측정되는 편차범위 내에서 측정되어 양호한 재현성을 보였다. 따라서, 암석시험편의 개수를 2, 4, 8개로 달리하며 수침진공 한 재현성 실험에서는 표준시험법에 따라서 1 torr 정도의 고진공을 사용하는 경우에는 여러 개의 시료를 동시에 수침진공하여도 산출되는 유효공극률에는 영향을 미치지는 않는다. 온도, 습도, 현지기압 등 기상자료와 시험편의 물속무게를 비교하고 대기 온도가 물의 온도, 밀도 및 부력에 영향을 주어 결국 시험편의 물속무게를 잘못 평가할 수 있음을 보였다. 따라서 시험편의 유효공극률을 정교하게 산출하기 위해서는 시험편의 물속무게를 측정할 때 물의 온도를 실험조건에 포함시키거나 다른 물리량과 함께 측정하여 물의 밀도 변화에 따른 물속무게 변화를 보정하여야 더 정밀한 유효공극률을 산출이 가능할 것이다.