• 제목/요약/키워드: Effective ionization Coefficient

검색결과 28건 처리시간 0.027초

플라즈마 방전 시뮬레이션에 의한 $CF_3I$-Xe 혼합 가스에서의 물성 특성 연구 (A Study on Characteristics of The $CF_3I$-Xe Mixtures gases in a Plasma Discharge Simulation)

  • 심응원;도안뚜안;전병훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1582-1583
    • /
    • 2011
  • Recently, it has been found that trifluoroiodomethane ( $CF_3I$) gas can replace $SF_6$ gas as a prospective substitute gas. For quantitative understanding of gas discharge phenomena, we should know electron collision cross sections and electron transport coefficients. Using electron collision cross sections of $CF_3I$ and Xe, we calculated elecron drift velocity, longitudinal coefficient, effective ionization coefficient in $CF_3I$-Xe mixtures using a two-term approximation of the Boltzmann equation. We also compared the electron transport coefficients in pure gas and those of 10%, 20%, 50%, and 70% $CF_3I$-Xe mixture gases. The present data may be showed appropriate ratios of $CF_3I$-Xe mixture gas for replacing the $SF_6$ gas.

  • PDF

Analysis of Insulating Characteristics of Cl2-He Mixture Gases in Gas Discharges

  • Tuan, Do Anh
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1734-1737
    • /
    • 2015
  • Insulating characteristics of Cl2-He mixture gases in gas discharges were analysed to evaluate ability of these gases for using in medium voltage and many industries. These are electron transport coefficients, which are the electron drift velocity, density-normalized longitudinal diffusion coefficient, and density-normalized effective ionization coefficient, in Cl2-He mixtures. A two-term approximation of the Boltzmann equation was used to calculate the electron transport coefficients for the first time over a wide range of E/N (ratio of the electric field E to the neutral number density N). The limiting field strength values of E/N, (E/N)lim, for these binary gas mixtures were also derived and compared with those of the pure SF6 gas.

Theoretical Studies of the Electrical Discharge Characteristics of Sulfur Hexafluoride

  • Radmilovic-Radjenovic, Marija;Radjenovic, Branislav
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.288-294
    • /
    • 2017
  • This paper contains results of the theoretical studies of the electrical breakdown properties in sulfur hexafluoride. Since the strong interaction of high-energy electrons with the polyatomic sulfur hexafluoride molecule causes their rapid deceleration to the lower energy of electron capture and dissociative attachment, the breakdown is only possible at relatively high field strengths. From the breakdown voltage curves, the effective yields that characterize secondary electron productions have been estimated. Values of the effective yields are found to be more consistent if they are derived from the experimentally determined values of the ionization coefficient and the breakdown voltages. In addition, simulations were performed using an one-dimensional Particle-in-cell/Monte Carlo collision code. The obtained simulation results agree well with the available experimental data with an error margin of less than 10% over a wide range of pressures and the gap sizes. The differences between measurements and calculations can be attributed to the differences between simulation and experimental conditions. Simulation results are also compared with the theoretical predictions obtained by using expression that describes linear dependence of the breakdown voltage in sulfur hexafluoride on the pressure and the gap size product.

실리콘 전력 MOSFET의 온도에 따른 항복전압 및 On 저항 (Temperature Dependent Breakdown Voltage and On-resistance of Si Power MOSFETs)

  • 박일용;최연익;정상구
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권4호
    • /
    • pp.246-248
    • /
    • 2000
  • Closed-form expressions for the temperature dependent breakdown voltage and the on-resistance of the Si power MOSFETs were derived by employing effective temperature dependent ionization coefficient for electrons and holes. The breakdown voltage increases by 20% and the on-resistance increases 2 times when the temperature increases from 300 K to 423 K. The analytic results normalized to the values at 300 K show good agreement with the experimental data of Motorola within 3.5% and 7% for the breakdown voltage and the on-resistance, respectively.

  • PDF

A New Analytical Method for Erythromycin in Fish by Liquid Chromatography/Tandem Mass Spectrometry

  • Park, Mi-Jung;Park, Mi-Seon;Lee, Tae-Seek;Shin, Il-Shik
    • Food Science and Biotechnology
    • /
    • 제17권3호
    • /
    • pp.508-513
    • /
    • 2008
  • Erythromycin has been used to treat Streptococosis, Edwardsiel1osis, Vibriosis, Bacterial enteritis in the cultured fish. In this study, a rapid and effective erythromycin analysis method with new sample treatment protocol and liquid chromatography/tandem mass spectrometry (LC/MS/MS) system for fish products was developed. For the erythromycin extraction from fish muscle, the solvent mixture composed of 0.2% meta-phosphoric acid and methanol (6:4) showed good recovery rate, and the optimum extraction solvent volume was 20 mL. Erythromycin detection using LC/MS/MS were carried out under electro spray ionization (ESI) positive condition and erythromycin mass value 576.2 and 157.9. And the detection limit of the established method was 0.005 mg/kg in fish products. The recovery rate of the developed method applied to the fish species were as following, olive flounder, $87.6{\pm}5.0%$; black rockfish, $87.2{\pm}6.4%$; eel, $85.2{\pm}4.8%$; and rainbow trout, $86.0{\pm}6.2%$. In the established method in this study, the correlation of coefficient values ($R^2$) of erythromycin calibration curve (n=11) was 0.9998.

세포탁심의 공장 및 비점막흡수에 미치는 이온쌍의 효과 (Effect of Ion-Pair on Jejunal and Nasal Absorption of Cefotaxime)

  • 박기배;전승;이광표
    • Journal of Pharmaceutical Investigation
    • /
    • 제25권4호
    • /
    • pp.353-363
    • /
    • 1995
  • The purpose of this study was to investigate the intestinal and nasal absorption enhancement of cefotaxime (CTX) by ion-pairing with counterions and to design an effective oral and intranasal drug delivery system for antibiotics. Counterions for absorption promotion were cationic surfactants [cetylpyridinium chloride (CP), cetrimide (CT) and benzalkonium chloride (BA)]. In the presence of counterions, the apparent partition coefficient of cefotaxime was increased depending on the molar concentration of the counterions. Anion interference was observed for ion-pairing of cefotaxime with counterions because of the counterbalance between an anion and counterions. The present study employed the in situ simultaneous nasal and intestinal perfusion technique in rats. The apparent permeabilities $(P_{app})$ of cefotaxime were $1.43{\pm}0.04{\times}10^{-5}\;cm/sec(mean{\pm}S.E)$ in the nasal cavity and 0 in the jejunum, respectively, which indicated that the intrinsic absorptivity of cefotaxime was greater in the nasal cavity than in the jejunum. When ionupairing formers were used, the decreasing order of apparent cefotaxime permeability $(P_{app},\;10^{-5}\;cm/sec)$, corrected for surface area of absorption, was as followings: $BA\;(7.50{\pm}0.36)\;>\;CT\;(4.92{\pm}0.24)\;>\;CP\;(3.01{\pm}0.17)$ in the jejunum and $BA\;(22.31{\pm}1.36)\;>\;CP\;(18.24{\pm}0.81)\;>\;CT \;(16.22{\pm}1.87)$ in the nasal cavity. The increase in permeability of cefotaxime was about 13-fold in the rat nasal cavity and was marked in the rat jejunum for ion-pairing with counterions as compared to those without ion-pairing. The damages of jejunal and nasal mucosal membrane by counterions were observed within approximately 2hrs after removal of ion-pair of cefotaxime with counterions from the nasal cavity and jejunum. These results suggest that CP can be used as an ion-pairing former in the jejunum and CP and CT can be used as ion-pairing formers in the nasal cavity for cefotaxime, as well as for poorly absorbed drugs with a negative charge due to ionization.

  • PDF

A Dilute-and-Shoot LC-MS/MS Method for Screening of 43 Cardiovascular Drugs in Human Urine

  • Pham, Thuy-Vy;Lee, Gunhee;Mai, Xuan-Lan;Le, Thi-Anh-Tuyet;Nguyen, Thi Ngoc Van;Hong, Jongki;Kim, Kyeong Ho
    • Mass Spectrometry Letters
    • /
    • 제12권1호
    • /
    • pp.1-10
    • /
    • 2021
  • A simple, specific, and economical LC-MS/MS method was investigated for the screening of 43 prescribed antihypertensive and related drugs in human urine. The urine samples were simply prepared by diluting and mixing with internal standard before directly introduced to the LC-MS/MS system, which is fast, straightforward, and cost-effective. Fractional factorial, Box-Behnken, and I-optimal design were applied to screen and optimize the mass spectrometric and chromatographic factors. The analysis was carried out on a triple quadrupole mass spectrometer system utilizing multiple reaction monitoring with positive and negative electrospray ionization method. Chromatographic separation was performed on a Thermo Scientific Accucore RP-MS column (50 × 3.0 mm ID., 2.6 ㎛) using two separate gradient elution programs established with the same mobile phases. Chromatographic separation was performed within 12 min. The optimal method was validated based on FDA guideline. The results indicated that the assay was specific, reproducible, and sensitive with the limit of detection from 0.1 to 50.0 ㎍/L. The method was linear for all analytes with coefficient of determination ranging from 0.9870 to 0.9981. The intra-assay precision was from 1.44 to 19.87% and the inter-assay precision was between 2.69 and 18.54% with the recovery rate ranges from 84.54 to 119.78% for all drugs measured. All analytes in urine samples were stable for 24 h at 25℃, and for 2 weeks at -60℃. The developed method improves on currently existing methods by including larger number of cardiovascular medications and better sensitivity of 12 analytes.

QuEChERS법 및 LC-MS/MS를 이용한 농산물 중 Oxytetracycline의 잔류시험법 개발 및 검증 (Development and Validation of the Analytical Method for Oxytetracycline in Agricultural Products using QuEChERS and LC-MS/MS)

  • 조성민;도정아;이한솔;박지수;신혜선;장동은;조명식;정용현;이강봉
    • 한국식품위생안전성학회지
    • /
    • 제34권3호
    • /
    • pp.227-234
    • /
    • 2019
  • 옥시테트라사이클린은 침투이행성 살균제로 배추, 고추 등의 농산물에 무름병, 줄기속마름병에 효과가 있다. 본 연구는 농산물 중 기준신설 예정농약 옥시테트라사이클린이 농산물 대하여 등록되지 않아 이에 대한 공정시험법을 개발하기 위하여 수행되었다. 옥시테트라사이클린의 잔류물의 정의는 미국, 일본의 경우 농산물 대상으로 모화합물로 설정되어 있다. 현재, 국내에서는 농산물 중 옥시테트라사이클린의 잔류물의 정의 및 잔류허용기준이 설정되어있지 않고, 국내 농산물(고추 등)에 대한 잔류허용기준 신설이 최초 요청되었으며 국내 유통 농산물 중 잔류량에 대한 안전관리 확보를 위해 잔류물의 정의를 모화합물로 규정하고 적부판정을 위한 공정시험법을 개발하고자 하였다. 옥시테트라사이클린의 물리 화학적 특성을 고려하여 QuEChERS법을 이용한 추출 및 정제법을 최적화하여 LC-MS/MS에 의한 분석법을 확립하였다. 수용성 유기용매인 메탄올을 추출 용매로 사용하여 pH 조절 및 염화나트륨을 첨가하여 추출법을 최적화하고, d-SPE 흡착제를 이용하여 간섭물질을 효과적으로 제거하여 정제법을 확립하였다. 옥시테트라사이클린의 결정계수($r^2$)는 0.99 이상으로 높은 직선성을 보여주었고, 옥시테트라사이클린의 시험법 정량한계(LOQ)는 0.01 mg/kg이며, 대표 농산물 5종(현미, 감자, 대두, 감귤, 고추)에 대하여 LOQ (0.01 mg/kg), $10{\times}LOQ$ (0.1 mg/kg), $50{\times}LOQ$ (0.5 mg/kg) 수준으로 회수율 실험한 결과 평균 회수율(n=5)은 80.0~108.2%이었으며 상대표준편차는 11.4%이하로 확인되었다. 또한 실험실간 검증 결과 두 실험실간 회수율 결과에 따른 평균값은 83.5~103.2%이며 변이계수는 14.1% 이하로 조사되어, 본 연구는 국제식품규격위원회 가이드라인(Codex Alimentarius Commission, CAC/GL 40)의 잔류농약 분석 기준 및 식품의약품안전평가원의 '식품등 시험법 마련 표준절차에 관한 가이드라인(2016)'에 적합한 수준임을 확인하였다. 따라서 본 연구에서 개발한 시험법은 농산물 중 잔류할 수 있는 옥시테트라사이클린의 안전관리를 위한 공정시험법으로 활용 가능할 것이다.