• 제목/요약/키워드: Effective absorption ratio

검색결과 112건 처리시간 0.023초

Energy absorption of reinforced concrete deep beams strengthened with CFRP sheet

  • Panjehpour, Mohammad;Abang Ali, Abang Abdullah;Aznieta, Farah Nora
    • Steel and Composite Structures
    • /
    • 제16권5호
    • /
    • pp.481-489
    • /
    • 2014
  • The function of carbon fibre reinforced polymer (CFRP) reinforcement in increasing the ductility of reinforced concrete (RC) deep beam is important in such shear-sensitive RC member. This paper aims to investigate the effect of CFRP-strengthening on the energy absorption of RC deep beams. Six ordinary RC deep beams and six CFRP-strengthened RC deep beams with shear span to the effective depth ratio of 0.75, 1.00, 1.25, 1.50, 1.75, and 2.00 were tested till failure in this research. An empirical relationship was established to obtain the energy absorption of CFRP-strengthened RC deep beams. The shear span to the effective depth ratio and growth of energy absorption of CFRP-strengthened deep beam were the significant factors to establish this relationship.

등온열량계를 사용한 고흡수성 재료의 유효흡수율 측정: 비표면적의 영향 (Effective Absorption Capacity of Highly Absorptive Materials using Isothermal Calorimetry, Considering the Effect of Specific Surface Area)

  • 이보연
    • 대한건축학회논문집:구조계
    • /
    • 제34권2호
    • /
    • pp.49-56
    • /
    • 2018
  • The use of highly absorptive materials in cement-based materials is increasing for internal curing purpose. However, calculation of correct absorption capacity of such materials is not easy, which leads to change in the effective water-to-cement ratio of cement paste by either absorbing or releasing water. In this study, effective absorption capacity of a highly absorptive material was found using isothermal calorimetry. Moreover, the effect of specific surface area was investigated. It was found that the method was capable of finding effective water absorption capacity of activated carbon fiber. For the activated carbon fiber used in this research, the effect of specific surface area was negligible because the high BET surface area was due to micropores less than 1nm, which does not affect the rate of hydration curve. Thus, the effective absorption capacity of such materials can be found successfully using this method.

진단방사선 영역에서 증감지의 유효이용에 관한 연구 (A Study on the Effective Utilization of Intensifying Screens in the Region of Diagnostic Radiology)

  • 김영근;이경섭
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제22권1호
    • /
    • pp.43-47
    • /
    • 1999
  • In order to obtain effective utilization of intensifying screens[$CaWO_4(W),\;Gd_2O_2S:Tb(Gd)$, BaFCl : Eu(Ba)] over the diagnostic radiology range, we calculated absorption coefficient (${\mu}$), absorption efficiency (${\eta}_{\alpha}$) and absorbed energy ratio(R) and analyzed effects of these properties on X-ray image, finally concluded as below. Regardless of presence of contrast media, absorption coefficient of Gd the highest and decreased with increase of thickness and kVp. Absorption efficiency related with absorbance of fluorescent materials showed the highest value for the Gd, and discontinuous points exhibited at around $80{\sim}90\;kVp$ and $90{\sim}100kVp$ for the Ba and the Gd, respectively. Furthermore, the absorbed energy ratio(R) correspond to contrast of reflection showed the largest value for the W in the absence of contrast media, and for the Gd in the case of the existence of it, and the ratio was decreased with increasing of incident energy. Owing to these properties, we assumed that it was more preferable to use rare earth type intensifying screen for the radiography using in the C.M.(I, Ba), while in the general radiography, $CaWO_4$ intensifying screen was applicable.

  • PDF

이성분 나노유체를 이용한 암모니아/물 기포 흡수기 설계 (Design of an Ammonia/water Bubble Absorber with Binary Nanofluids)

  • 김진경;김성수;강용태
    • 설비공학논문집
    • /
    • 제18권7호
    • /
    • pp.556-562
    • /
    • 2006
  • The objectives of this paper are to analyze simultaneous heat and mass transfer performance for a plate type bubble absorber with binary nanofluids numerically and to investigate the effects of binary nanofluids and surfactants on the size of the bubble absorber. The effective absorption ratio represents the effect of binary nanofluids and surfactants on the absorption performance. The kinds and concentrations of nano-particles and surfactants are considered as the key parameters. The results show that the addition of surfactants can reduce the size of absorber up to 74.4%, the application of binary nanofluids does the size up to 63.6%. Combination of binary nanofluids and surfactants can reduce the size of absorber up to 77.4%.

연속공극을 갖는 기포콘크리트의 흡음특성에 관한 연구 (A Study on Sound Absorption Properties of Foamed Concrete with Continuous Voids)

  • 이승한;박정준;황보광수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.567-570
    • /
    • 2000
  • This study is designed to manufacture the continuous foamed concrete and the sound absorption characteristics investigation due to continuous voids ratio. According to the results of experiment, it was shown that continuous voids of the foamed concrete has the influence of the amount used of foaming agent, the viscosity and flowability of cement paste, and also is shaped by cohesive power of bubbles. Also the sound absorption ratio of the foamed concrete is subject to increase as the density becomes low by raising the continuous voids ratio. The cement paste with low water-cement ratio and high cement fineness are very effective to prevent weak strength of formed concrete caused by the increase of the porosity.

  • PDF

공기 중 메틸에틸케톤 제어를 위한 Pilot-Scale 흡수 시스템의 운영인자 분석 (Analysis of Operation Parameters of Pilot-Scale Packed-Absorption System for Airborne Methyl Ethyl Ketone Control)

  • 조완근;김왕태
    • 한국환경과학회지
    • /
    • 제20권4호
    • /
    • pp.501-509
    • /
    • 2011
  • Unlike many laboratory-scale studies on absorption of organic compounds (VOCs), limited pilot-scale studies have been reported. Accordingly, the present study was carried out to examine operation parameters for the effective control of a hydrophilic VOC (methyl ethyl ketone, MEK) by applying a circular pilot-scale packed-absorption system (inside diameter 37 cm ${\times}$ height 167 cm). The absorption efficiencies of MEK were investigated for three major operation parameters: input concentration, water flow rate, and ratio of gas flow-rate to washing water amount (water-to-gas ratio). The experimental set-up comprised of the flow control system, generation system, recirculation system, packed-absorption system, and outlet system. For three MEK input concentrations (300, 350, and 750 ppm), absorption efficiencies approached near 95% and then, decreased gradually as the operation time increased, thereby suggesting a non-steady state condition. Under these conditions, higher absorption efficiencies were shown for lower input concentration conditions, which were consistent with those of laboratory-scale studies. However, a steady state condition occurred for two input concentration conditions (100 and 200 ppm), and the difference in absorption efficiencies between these two conditions were insignificant. As supported by an established gas-liquid absorption theory, a higher water flow rate exhibited a greater absorption efficiency. Moreover, as same with the laboratory-scale studies, the absorption efficiencies increased as water-to-gas ratios increased. Meanwhile, regardless of water flow rates or water-to-gas ratios, as the operation time of the absorption became longer, the pH of water increased, but the elevation extent was not substantial (maximum pH difference, 1.1).

박판 사각튜브의 에너지 흡수 특성 (The Energy Absorption Characteristics of Thin-walled Rectangular Tubes)

  • 김천욱;한병기;원종진;임채홍
    • 한국자동차공학회논문집
    • /
    • 제4권3호
    • /
    • pp.83-91
    • /
    • 1996
  • This paper investigates the energy absorption characteristics of thin-walled rectangular tubes. In the compact mode, the crushing process of a thin-walled tube is analyzed into 3 parts by the ratio of outward to inward fold length. The mean crush load and the half-wave folding length are determined by using minimum energy principle. The effective crush distance can be determined when half-wave folding length is known, and the number of folds is derived when crush distance is given. Thus when the crush distance is given, energy absorption capacity can be estimated with mean crush load and number of folds. And the theoretical value is proven experimentally.

  • PDF

아세트산 처리 갑오징어갑 칼슘제의 기능적 특성 (Functional Properties of Calcium Powder of Cuttle Bone Treated with Acetic Acid)

  • 김진수;조문래;허민수
    • 한국수산과학회지
    • /
    • 제36권2호
    • /
    • pp.74-79
    • /
    • 2003
  • The functional properties such as a firming maintenance capacity for fermented vegetables, protein coagulation capacity antibacterial activity, calcium and peroxide absorption capacity of calcium powder of cuttle bone treated with acetic acid (ATC) were examined. In the Korean pickled cucumbers (20 days), the calcium content of ethanol insoluble solids was 5,264.9 mg/100 g and this value was higher than that of control (2,036.4 mg/100 g). Protein coagulation capacity of ATC was $0.9\%$ and its calcium absorption capacity was $49.3\%.$ The peroxide absorption capacity of ATC was shown $0-1.1\%$ range. Antibacterial activity was detected above $0.2\%.$ The ATC was effective in a firming maintenance of fermented vegetables (cucumber), coagulation capacities for soybean milk and antibacterial activity. The ATC was not effective in clarifying wastewater. Peroxide absorption capacity toward linoleic acid could not be checked by ATC, but its calcium absorption ratio was high compared to that of commercial calcium powder.

폐활성탄을 혼입한 콘크리트의 물리.역학적 성질 (Physical and Mechanical Properties of Concrete Using Waste Activated Carbon)

  • 강현수;성찬용
    • 한국농공학회논문집
    • /
    • 제51권1호
    • /
    • pp.21-26
    • /
    • 2009
  • This study was performed to evaluate the physical and mechanical properties of concrete using waste activated carbon. Materials used were ordinary portlant cement, crushed coarse aggregate, natural fine aggregate, waste activated carbon, and superplasticizer. The substitution ratios of waste activated carbon were 0,1,2,3,4,5,6,7,8,9 and 10%. The unit weight was decreased and water absorption ratio was increased with increasing the waste activated carbon content, respectively. When the substitution ratio of waste activated carbon was 3%, compressive strength, flexural strength and dynamic modulus of elastisity were more higher than that of the ordinary portland cement (OPC), and it was decreased with increasing the waste activated carbon content, respectively. The most effective contents of waste activated carbon was 2% in performance and 4% in practical use Accordingly, waste activated carbon can be used for concrete material.

응축기 배열회수에 의한 흡수식 냉동기의 고효율화에 관한 연구 (A Study on the COP Improvement of Absorption Chillers by Recovering Heat from the Condenser)

  • 박찬우
    • 설비공학논문집
    • /
    • 제18권9호
    • /
    • pp.738-744
    • /
    • 2006
  • In order to utilize the condensation heat of refrigerants in condenser on the absorption chiller system, the solution cooled condenser (SCC) was proposed using the weak solution of absorber as a cooling medium. The increase of COP with the increase of UA of the solution cooled condenser was approximately 0.009 in maximum with single effect one, and is about maximum 0.008 in occasion of double effect one with series flow compared to that without. In the case of heat exchanger, effectiveness is about 0.85, it's increments are 0.008 and 0.0072, respectively. And solution cooled condenser is more effective device in the single effect absorption system than double effect system for the principle of operation. On the other hand, as the solution split ratio increases when the value of UA is fixed, COP is increased and as the solution split ratio increases when the value of UA is fixed, COP is increased. If the flow rate of cooling water or the value of UA is reduced in order to increases the heat recovery of solution cooled condenser, heat recovery of solution cooled condenser is increased a little but COP is decreased as the system pressure is increased.